Fan Heater
HD 3274
HD 3275
Philips Domestic Appliances and Personal Care
PRODUCT INFORMATION
Functions, features and operational aspects :
|
|
|
HD 3274 |
HD 3275 |
Switch : 4 positions : |
off |
|
x |
x |
|
cool air |
x |
x |
|
● |
1000 |
Watt |
x |
x |
● ● |
2000 |
Watt |
x |
x |
Thermostat |
|
|
x |
x |
Frost guard |
|
|
x |
x |
On/off power light |
|
|
x |
x |
Overheating protection |
|
|
x |
x |
Drip waterproof |
|
|
- |
x |
Stand/wall mounting bracket |
|
|
- |
x |
Voltage/frequency |
: 230 |
V / 50 Hz |
|
|
Power consumption |
: 1000 - 2000 Watt |
|
||
Safety |
: Insulation class |
|
|
Product meets the requirements regarding interference suppression on radio and television.
MSH coding 8823 274 00000 8823 275 00000
Published by Philips Domestic Appliances and Personal Care |
Printed in the Netherlands |
© Copyright reserved |
Subject to modification |
4822 729 22048 98/09
PCS 99 588
DISASSEMBLY ADVICE |
|
PARTS LIST HD 3274 / HD 3275 |
||||
CAPS OPERATION |
STAND 102 |
POS. |
DESCRIPTION |
|
|
SERVICE CODE |
KNOBS 1 |
|
1 |
CAP OPERATION KNOBS |
4822 462 10812 |
||
|
|
|||||
SWITCH KNOB 2 |
|
2 |
SWITCH KNOB |
|
|
4822 410 10791 |
|
3 |
THERMOSTAT KNOB |
|
4822 410 10792 |
||
THERMOSTAT KNOB 3 |
|
|
||||
|
4 |
SWITCH |
|
|
4822 273 10319 |
|
|
|
|
|
|||
SWITCH 4 |
|
5 |
THERMOSTAT |
|
|
4822 282 10299 |
THERMOSTAT 5 |
|
6 |
HEATING ELEMENT |
|
4822 259 10212 |
|
|
7 |
MOTOR |
|
|
4822 361 10521 |
|
PILOT LIGHT 9 |
|
|
|
|||
|
8 |
FAN BLADE |
|
|
4822 515 20148 |
|
|
|
|
|
|||
remove SCREW A (4x) |
|
9 |
PILOT LAMP |
|
|
4822 134 10056 |
remove FRONT PART 101 |
|
|
|
|
|
|
remove CAPS OPERATION |
|
NOTE: |
|
|
|
|
KNOBS 2 |
|
For standardisation reasons, only the red-coloured operation |
||||
|
|
|||||
|
|
knobs have been incorporated into this manual. |
||||
|
|
The dark blue coloured knobs have to be replaced by the |
||||
|
|
red-coloured ones. |
|
|
|
|
|
|
When a cordset has to be replaced, always use a cordset with |
||||
|
|
core wires with a diameter of 1.0 mm2. |
||||
|
|
Parts, with numbers from 100 upwards, cannot be ordered |
||||
|
|
separatly. |
|
|
|
|
MOTOR 7 |
|
|
|
|
|
|
HEATING ELEMENT 6 |
|
|
|
|
|
|
|
|
|
|
|
4 |
|
remove SCREW A 4x |
|
|
|
|
|
1000 W |
remove FRONT PLATE 101 |
|
|
|
|
3 |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
remove SCREW B 2x |
|
L |
|
|
2 |
|
|
|
|
|
|
|
|
FAN BLADE 8 |
|
|
|
|
1 |
1000 W |
|
|
|
|
|
M |
|
|
|
|
|
|
|
|
remove SCREW A 4x |
|
|
|
S |
|
|
|
|
|
|
|
|
|
remove FRONT PLATE 101 |
|
|
|
|
|
P. L. |
|
|
|
|
|
|
|
|
|
N |
|
|
|
|
|
|
|
T |
C. O. |
|
|
|
|
L |
= LINE |
|
P. L. = PILOT LIGHT (Not included in HD3271) |
|
|
|
N |
= NEUTRE |
|
S |
= SWITCH |
|
|
T = THERMOSTAT (Not included in HD3271) |
M |
= MOTOR |
||
|
|
C. O. = CUT OUT |
|
|
DAP0244 |
NOTE: AFTER THE PRODUCT HAS BEEN REPAIRED, IT
SHOULD FUNCTION PROPERLY AND HAS TO
MEET THE SAFETY REQUIREMENTS AND
LEGAL REGULATIONS AS LAID DOWN AND
OFFICIALLY ESTABLISHED AT THIS MOMENT.
Possible complaints
The heater doesn’t function :
1)When set to the cool air setting
action: Set the thermostat knob to the highest position.
2)The overheating safety device has been activated action: To reset the overheating device, remove the
mains plug from the wall socket and let the heater cool down for 30 minutes.