Philips E3 User Manual

E3 Series
GENERAL DUTY THERMOPLASTIC EMERGENCY LIGHTING
Page 1 of 2
E3112WS92SD2
E3112WPT86W2
11.87 "
(30.15 cm)
13.01"
(33.05 cm)
14.53"
(36.91 cm)
5.0"
(12.7 cm)
6.84"
(17.37 cm)
Features
is accomplished with up to
three lamp heads mounted
on the top of the unit. Most
often specified is Lightolier’s
“S” series rectangular lamp
heads. The “S” series lamp
heads incorporate a high
performance parabolic
reflector with a wedge base
tungsten lamp allowing
maximum spacing between
units along a path of egress.
A complete offering of Par 36
sealed beam tungsten, halogen
or MR16 LED lamp heads are
also available.
Housing: Constructed of
impact-resistant, UL 94 V-0,
5 VA thermoplastic. Mounting
is accomplished by means of
the universal j-box mounting
pattern or the keyhole
knockouts provided on the
rear of the housing. The cover
assembly closes and remains
secure via a snap-fit design
and offers tool-free access to
the housing interior. White or
black housing and lamp head
colors are available.
Operating Temperature
Range: Standard Location:
65°F (19°C) to 85°F (30°C)
Damp Location: 32°F (0°C) to
104°F (40°C)
Non-Diagnostic
Electronics: Standard
electronics systems include
a 120/277 VAC dual tap
input transformer. Standard
electronic performance
features include AC line latch,
brownout detection, and
low-voltage battery disconnect
circuitry to maximize battery
service life.
Self-Diagnostics
Electronics: Charging system
is microprocessor driven with
software embedded diagnostic
routine and temperature
compensation. 120/277 VAC
input, surge protection,
brownout , AC lockout, and
low voltage disconnect features
are standard.
Job Information Type:
Job Name:
Cat. No.:
Self-Testing Diagnostics
(optional): The diagnostic/
charging platform with self-
testing mode automatically
runs a one-minute self-test
every 30 days and a 30-minute
test on the sixth and twelfth
month. A one-minute or
90-minute test may be initiated
via the push to test switch on
the unit or by activating the
appropriate test command on
the optional IR test device.
Code Compliance
UL 924 listed. NFPA 101,
NEC, BOCA, OSHA and
IBC illumination standards.
Optional UL damp location
listing available (SD2 models
only) 0°C to 40°C.
Warranty
Three year full electronics
warranty. One year full plus
four year prorated lead calcium
battery warranty. Five year full
plus five year prorated nickel
cadmium battery warranty.
Notes:
E3 Series
GENERAL DUTY THERMOPLASTIC EMERGENCY LIGHTING
Ordering Information
Page 2 of 2
Lamp Heads
6 V Tungsten
S6 = 5.4 W S7 = 7.2 W S9 = 9 W
12 V Tungsten
S9 = 9 W S12 = 12.5 W S18 = 18 W
MR16 LED Lamp Heads* 12 V LED M7F** = 7 Watt , 35°
# of Heads
Blank = No Lamp Heads
1 = One Lamp Head 2 = Two Lamp Heads 3 = Three Lamp Heads
Model Designator
Blank = Standard, Non-Diagnostic Unit SD2 = Diagnostic Electronics
Factory Installed Options
A = Ammeter BD = Battery Disconnect Switch DL = Damp Location Listed EX = Special Input Transformer (specify voltage &
frequency)
F1 = 120 VAC Input Fuse F2 = 277 VAC Input Fuse P1 = 120 VAC Power Switch P2 = 277 VAC Power Switch T = Self-Testing Diagnostics TA = Audible Self-Testing Diagnostics TD = Time Delay, 15 Minutes V = Voltmeter
3
4
3
2
Housing Color
W = White B = Black
Series
6 V Lead Calcium
E3112 = 12 W E3125 = 25 W E3136 = 36 W E3150 = 50 W
6 V Nickel Calcium
E31N25 = 25 W E31N50 = 50 W
Accessories (order as a separate item) SDREMOTE = Infrared Remote Test Device PCS1 = Polycarbonate Vandal Shield WG5 = Wire Guard
Note 1) Not available with DL option. 2) Only available with non-diagnostic models. 3) Only available with diagnostic electronic models. 4) Some option combinations
may impact UL listing, consult factor y for specifics.
* Lamp included per UL acceptance. ** UL testing restricts using any substitutes for this lamp option.
12 V Lead Calcium
2
E3225 = 25 W E3236 = 36 W
1
E3250 = 50 W
12 V Nickel Calcium
E32N25 = 25 W E32N50 = 50 W
3
3
3
3
3
3
3
3
3
3
Electrical Specifications
Non-Diagnostic Models (60 Hz)
6 V Lead Calcium: 0.115 A (120 VAC), 0.050 A (277 VAC)
6 V NiCad: 0.160 A (120 VAC), 0.071 A (277 VAC)
12 V Lead Calcium: 0.126 A (120 VAC), 0.055 A (277 VAC)
12 V NiCad: 0.116 A (120 VAC), 0.051 A (277 VAC)
Self-Diagnostics Models (60 Hz)
6 V Lead Calcium: 0.113 A (120 VAC), 0.055 A (277 VAC)
6 V NiCad: 0.157 A (120 VAC), 0.065 A (277 VAC)
12 V Lead Calcium: 0.331 A (120 VAC), 0.146 A (277 VAC)
12 V NiCad: 0.200 A (120 VAC), 0.094 A (277 VAC)
Optics Wall mounted 7.5' AFF, ‘S9’ 6 V 9 W Tungsten Lamps Represented
7.5 ft.
0.3
0.4
1.1
0.7
1.2
2.3
0.6
2.4
1.8
0.4
2.3
1.0
0.4
1.6
0.6
0.5
0.9
0.6
0.4
0.7
0.6
0.4
0.9
0.8
0.5
1.4
1.5
0.8
2.3
2.4
2.6
1.7
0.9
25 ft.
0.3
0.2
Average initial footcandles at floor = 1.08
Maximum initial footcandles at floor = 3.0
Minimum initial footcandles at floor = 0.3
Maximum to minimum ratio = 10.00
* The optics layout shown is intended to be used as reference only. Standard reflectances used were 8 0/50/20. Lightolier is not responsible for site specific conditions that may alter the results.
Philips Lightolier e: lol.webmaster@philips.com t: (508) 679-8131 w: www.lightolier.com
E3 Series August 9, 2012
Specifications are subject to change without notice. © Koninklijke Philips Electronics N.V., 2012. All rights reserved.
1.6
0.5
0.3
1 FC Average
.5
0.7
2.0
0.4
0.7
0.6
1.9
0.7
2.2
0.4
2.6
2.0
1.3
0.4
Job Information Type:
0.7
0.4
1.2
0.6
0.4
0.8
0.6
0.4
0.7
0.6
0.4
1.1
1.1
0.6
1.8
2.0
0.7
2.5
2.2
0.4
2.2
0.9
0.2
0.8
0.2
0.3
6 ft.