The board operation is controlled through the bank of DIP Switches labeled SW1 located
on the component side of the board in the lower left corner. These switches must be set
for the cooler to operate properly. The switches numbered 1, 2, and 3 of the DIP switch
set the function of the board.
SW 1 SW2 SW3
Single Channel Cooler with communications OFF OFF OFF
Single Channel Cooler 2nd board ON OFF OFF
1st Frozen channel OFF OFF ON
nd
Frozen channel ON OFF ON
2
Dual Channel Cooler OFF ON OFF
NJ TC Display ON ON OFF
Display
Single Channel Cooler
Basic Display Description
3 digit plus sign temperature display
Temperature is displayed in tenths of °C
Green LED to display ‘Ready’ status
Green LED to display ‘Water Slip’ status
Red LED to display ‘TC Fail’ status
Detailed Display Description
The digital display shows both temperature and status of the cooler.
The display will display temperature constantly when the impinger
temperature is below the user set ‘Ready’ temperature and no other faults
are present. One fault is the ‘Water Slip’, the sensing of liquid water
downstream of the sensor, though the use of a water slip sensor. The other
fault would be a ‘TC Failure’ indicating an open thermocouple sensor.
The display will blink the temperature when impinger temperature is
above the user set ‘Ready’ temperature and no other faults are present.
The display switches every second between blank and the temperature, in
this condition.
If a ‘Water Slip’ failure is detected the display will switch between
showing the measured temperature and a symbolic “SLP”. The display
switches every second between “WS” and the temperature.
If a ‘TC Failure’ is detected the display will switch between showing
blank and the letters “tcF”.
If both a ‘TC Failure’ and a ‘Water Slip’ failure are detected the display
will switch between showing the letters “tcF” and a symbolic “SLP”.
The display switches every second between “tcF” and “SLP”.
Detailed LED Description
The LED indicators show the status of the cooler.
The top LED, which is green, will turn on when impinger temperature is
below the user set ‘Ready’ temperature.
The top LED will turn off when impinger temperature is above the user set
‘Ready’ temperature.
The middle LED, which is green, will turn on there is not a ‘Water Slip’
failure showing the system is working correctly.
The middle LED will turn off when water is detected.
The bottom LED, which is red, will turn off there is not a ‘TC Failure’
showing the system is working correctly.
The bottom LED will turn on when an open condition is detected on the
thermocouple.
The operation of the ‘Ready’ and Water Slip’ indicators changes if the
user selects the relay latching option. Once the ‘Ready’ temperature is
reached for the first time the latching option goes into effect. If an alarm
occurs after the first ‘Ready’ indication the relays will remain off until the
user supplies a contact closure to the board to reset the alarm. The LED
indicators will blink when the alarm condition has been removed but the
relay has not yet been reset.
1St Frozen
Basic Display Description
3 digit plus sign temperature display
Temperature is displayed in tenths of °C
Green LED to display ‘Ready’ status
Green LED to display ‘Valve’ status
Red LED to display ‘TC Fail’ status
Detailed Display Description
The digital display shows both temperature and status of the cooler.
The display will display temperature constantly when impinger
temperature is below the user set ‘Ready’ temperature and no other faults
are present. The fault would be a ‘TC Failure’ indicating an open
thermocouple sensor.
The display will blink the temperature when impinger temperature is
above the user set ‘Ready’ temperature and no other faults are present.
The display switches every second between blank and the temperature, in
this condition.
If a ‘TC Failure’ is detected the display will switch between showing
blank and the letters “tcF”.
Detailed LED Description
The LED indicators show the status of the cooler.
The top LED, which is green, will turn on when active impinger
temperature is below the user set ‘Ready’ temperature. Since this is a
switching system the ‘Ready’ indication is tied to the active impinger.
The top LED will turn off when the active impinger temperature is above
the user set ‘Ready’ temperature.
The middle LED, which is green, will turn on the flow control valve is on.
The valve is used to switch the flow stream between the cycling
impingers. The valve is on when the stream is flowing through the 2nd
impinger.
The bottom LED, which is red, will turn off there is not a ‘TC Failure’ for
the 1st frozen impinger only
The bottom LED will turn on when an open condition is detected on the
thermocouple.
nd
Frozen
2
Basic Display Description
3 digit plus sign temperature display
Temperature is displayed in tenths of °C
Detailed Display Description
The digital display shows both temperature and status of the cooler.
The display will display temperature constantly when impinger
temperature is below the user set ‘Ready’ temperature and no other faults
are present. The fault would be a ‘TC Failure’ indicating an open
thermocouple sensor.
The display will blink the temperature when impinger temperature is
above the user set ‘Ready’ temperature and no other faults are present.
The display switches every second between blank and the temperature, in
this condition.
If a ‘TC Failure’ is detected the display will switch between showing
blank and the letters “tcF”.
Detailed LED Description
The 2nd frozen impinger does not have any LED indication
Dual Channel Cooler
Basic Display Description
3 digit plus sign temperature display
Temperature is displayed in tenths of °C
Green LED indicate 1 channel displayed
Green LED indicate 2 channel displayed
Detailed Display Description
The digital display shows both temperature and status of the cooler.
The display can be set to constantly switch between the two channels or to
work with an external dry contact to select channel to be displayed.
The display functions the same for both channels.
The display will display temperature constantly when impinger
temperature is below the user set ‘Ready’ temperature and no other faults
are present. One fault is the ‘Water Slip’, the sensing of liquid water
downstream of the sensor, though the use of a water slip sensor. The other
fault would be a ‘TC Failure’ indicating an open thermocouple sensor.
The display will blink the temperature when impinger temperature is
above the user set ‘Ready’ temperature and no other faults are present.
The display switches every second between blank and the temperature, in
this condition.
If a ‘Water Slip’ failure is detected the display will switch between
showing the measured temperature and a symbolic “SLP”. The display
switches every second between “SLP” and the temperature.
If a ‘TC Failure’ is detected the display will switch between showing
blank and the letters “tcF”.
If both a ‘TC Failure’ and a ‘Water Slip’ failure are detected the display
will switch between showing the letters “tcF” and a symbolic “SLP”.
The display switches every second between “tcF” and “SLP”.
The single ‘Water Slip’ alarm will be displayed on both channels.
A single channel, channel 1, can be constantly displayed be selecting the
switch option in set up and omitting the switch.
Detailed LED Description
The LED indicators show the current channel being displayed.
The top LED, which is green, will turn on when channel 1 is displayed.
The lower LED, which is green, will turn on when channel 2 is displayed.
NJ Thermocouple Display
Basic Display Description
3 digit plus sign temperature display
Temperature is displayed in tenths of °C
Green LED indicate 1 channel displayed
Green LED indicate 2 channel displayed
Detailed Display Description
The digital display shows both temperature and status of the cooler.
The display can be set to constantly switch between the two channels or to
work with an external dry contact to select channel to be displayed.
The display functions the same for both channels.
The display will display temperature constantly when impinger
temperature is below the user set ‘Ready’ temperature and no other faults
are present. One fault is the ‘Water Slip’, the sensing of liquid water
downstream of the sensor, though the use of a water slip sensor. The other
fault would be a ‘TC Failure’ indicating an open thermocouple sensor.
The display will blink the temperature when impinger temperature is
above the user set ‘Ready’ temperature and no other faults are present.
The display switches every second between blank and the temperature, in
this condition.
If a ‘Water Slip’ failure is detected the display will switch between
showing the measured temperature and a symbolic “SLP”. The display
switches every second between “SLP” and the temperature.
If a ‘TC Failure’ is detected the display will switch between showing
blank and the letters “tcF”.
If both a ‘TC Failure’ and a ‘Water Slip’ failure are detected the display
will switch between showing the letters “tcF” and a symbolic “SLP”.
The display switches every second between “tcF” and “SLP”.
The single ‘Water Slip’ alarm will be displayed on both channels.
A single channel, channel 1, can be constantly displayed be selecting the
switch option in set up and omitting the switch.
Detailed LED Description
The LED indicators show the current channel being displayed.
The top LED, which is green, will turn on when channel 1 is displayed.
The lower LED, which is green, will turn on when channel 2 is displayed.
Outputs
Single Channel Cooler
The impinger temperature is available as a voltage output equal to 0.1 V / °C.
Analog out 1 is controlled by the temperature measured from thermocouple #1.
Each control board has two field replaceable relays.
Relay 1 is activated when the impinger temperature is below the user set ‘Ready’
temperature. The relay does not deactivate until the impinger temperature rises to
0.5 °C above the ‘Ready’ temperature. This hysteresis is set to avoid relay chatter
when the impinger is near the set temperature.
Relay 2 is activated when the ‘Water Slip’ sensor is dry and the system is working
properly. The relay is off when water is detected at the sensor.
Both relays have two sets of contacts. The standard factory wiring uses one set to
operate a sample pump. The second set of contacts is available for field wiring by
the user.
The relays can be selected to operate either in automatic reset or latching by the
user.
1St Frozen
The impinger temperature is available as a voltage output equal to 0.1 V / °C.
Analog out 1 is controlled by the temperature measured from thermocouple #1.
Each control board has two field replaceable relays.
Relay 1 is activated when the active impinger temperature is below the user set
‘Ready’ temperature. The relay does not deactivate until the impinger temperature
rises to 0.5 °C above the ‘Ready’ temperature. This hysteresis is set to avoid relay
chatter when the impinger is near the set temperature. The source for the ‘Ready’
st
relay will change depending on which of the impingers, 1
or 2nd frozen, is active.
Relay 2 controls the valve used to control the sample flow to the frozen
impingers. The relay is activated when the 2
nd
frozen impinger is active.
Both relays have two sets of contacts. The standard factory wiring uses one set of
contacts. The second set of contacts is available for field wiring by the user.
2nd Frozen
The impinger temperature is available as a voltage output equal to 0.1 V / °C.
Analog out 1 is controlled by the temperature measured from thermocouple #1.
Each control board has two field replaceable relays.
Relay 1 is activated when the 2nd frozen impinger temperature is below the user
set ‘Ready’ temperature. The relay does not deactivate until the impinger
temperature rises to 0.5 °C above the ‘Ready’ temperature. This hysteresis is set
to avoid relay chatter when the impinger is near the set temperature.
Relay 2 is not used
Neither relay is factory wired.
Dual Channel Cooler
The impinger temperatures are available as a voltage output equal to 0.1 V / °C.
Analog out 1 is controlled by the temperature measured from thermocouple #1.
Analog out 2 is controlled by the temperature measured from thermocouple #2.
Each control board has two field replaceable relays.
Relay 1 is activated when the impinger temperature channel 1 is below the user
set ‘Ready’ temperature. The relay does not deactivate until the impinger
temperature rises to 0.5 °C above the ‘Ready’ temperature. This hysteresis is set
to avoid relay chatter when the impinger is near the set temperature.
Relay 2 is activated when the impinger temperature channel 2 is below the user
set ‘Ready’ temperature. The relay does not deactivate until the impinger
temperature rises to 0.5 °C above the ‘Ready’ temperature. This hysteresis is set
to avoid relay chatter when the impinger is near the set temperature.
The unit can be set to have the ‘Water Slip’ input to control the relays in several
ways. The ‘Water Slip’ can;
Control Relay1 in conjunction with ‘Ready’ on channel 1
Control Relay2 in conjunction with ‘Ready’ on channel 2
Control Relay2 alone
Both relays have two sets of contacts. The standard factory wiring uses one set to
operate a sample pump. The second set of contacts is available for field wiring by
the user.
NJ Thermocouple Display
The impinger temperatures are available as a voltage output equal to 0.1 V / °C.
Analog out 1 is controlled by the temperature measured from thermocouple #1.
Analog out 2 is controlled by the temperature measured from thermocouple #2.
Each control board has two field replaceable relays.
Relay 1 is activated when the impinger temperature channel 1 is below the user
set ‘Ready’ temperature. The relay does not deactivate until the impinger
temperature rises to 0.5 °C above the ‘Ready’ temperature. This hysteresis is set
to avoid relay chatter when the impinger is near the set temperature.
Relay 2 is activated when the impinger temperature channel 2 is below the user
set ‘Ready’ temperature. The relay does not deactivate until the impinger
temperature rises to 0.5 °C above the ‘Ready’ temperature. This hysteresis is set
to avoid relay chatter when the impinger is near the set temperature.
The unit can be set to have the ‘Water Slip’ input to control the relays in several
ways. The ‘Water Slip’ can;
Control Relay1 in conjunction with ‘Ready’ on channel 1
Control Relay2 in conjunction with ‘Ready’ on channel 2
Control Relay2 alone
Both relays have two sets of contacts. The standard factory wiring uses one set to
operate a sample pump. The second set of contacts is available for field wiring by
the user.
Switch Inputs
Single Channel Cooler
There are two dry contact inputs for each board labeled External Switches.
External Switch 1 will force the relays off even when there is no water present
and the impinger temperature is below ‘Ready’. This can be used to keep the
sample pump from turning on as soon as the cooler is ready to allow for other
portions of the system to become ready for sampling.
External Switch 2 will reset the latched alarms. This switch is only active when
the Relay = Latch option is selected in set up.
St
Frozen
1
There are two dry contact inputs for each board labeled External Switches.
External Switch 1 will force the changeover of active impingers in the frozen
system. The switch is not active during the changeover period when both
impingers are cooling.
External Switch 2 has no associated function.
nd
2
Frozen
External Switches have no associated functions.
Dual Channel Cooler
There are two dry contact inputs for each board labeled External Switches.
External Switch 1 will select the channel to be displayed. This switch is only
active when the Display = Switch option is selected in set up. An open connection
between the terminals displays channel 1; a contact closure displays channel 2.
External Switch 2 has no associated function.
NJ Thermocouple Display
There are two dry contact inputs for each board labeled External Switches.
External Switch 1 will select the channel to be displayed. This switch is only
active when the Display = Switch option is selected in set up. An open connection
between the terminals displays channel 1; a contact closure displays channel 2.
External Switch 2 has no associated function.
Calibration
Overview
Each board must be calibrated before use. The calibration consist of several steps
including setting the Cold Junction temperature, calibrating the thermocouple
input for channel 1 and 2, and calibrating the voltage output 1 and 2.
A volt meter and a thermocouple calibrator are required for the operations.
The cold junction temperature should be set first prior to the thermocouple
calibration.
Cold Junction Temperature
Turn both #5 and #6 switches to the ‘ON’ position of the DIP Switch labeled
SW1. The display will toggle between a label of ‘ cJt’ and the value of the board
temperature. The label ‘ cJt’ will be displayed for 1 second followed by the value
of the board temperature for 3 seconds.
Measure the temperature of the board near the thermocouple connectors. Adjust
the displayed temperature using the ‘UP’ or ‘DOWN’ buttons. When the
temperature displayed matches the measured value; move switches #5 and #6 to
the ‘OFF’ position to record the value.
Analog Calibration (Voltage output calibration)
Move switch #6 to the ‘ON’ position of the DIP Switch labeled SW1 to begin
calibration. The front digital display will go blank. The back indicator LED lights
will be lit and display the calibration stage.
Voltage Output Calibration
Voltage 1
Connect negative probe of the volt meter to ‘Analog Output’ connector CN11 to
pin 1 ‘COMM’.
Connect positive probe of the volt meter to ‘Analog Output’ connector CN11 to
pin 3 ‘AN1(+)’.
Set the voltmeter range to +/- 2.000 VDC, 1 mV resolution.
Voltage 1 Zero is the first step; The top light is on solid and the next three lights
will blink.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
BLINK
BLINK
BLINK
The volt meter will display the voltage associated with 0.0 °C. Adjust the output
voltage using the ‘UP’ and ‘DOWN’ buttons. Press the ‘NEXT’ button when the
voltage output measures 0.000 +/- 0.005 VDC.
Voltage 1 Span is the second step; The top light is on solid and the next two lights
will blink and the bottom light is on solid.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
BLINK
BLINK
SOLID
The volt meter will display the voltage associated with 20.0 °C. Adjust the output
voltage using the ‘UP’ and ‘DOWN’ buttons. Press the ‘NEXT’ button when the
voltage output measures 1.000 +/-0.005 VDC.
Move the positive probe of the volt meter to ‘Analog Output’ connector CN11 to
pin 2 ‘AN2(+)’.
Voltage 2 Zero is the third step; the top and second lights are on solid and the
lower two lights will blink.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
SOLID
BLINK
BLINK
The volt meter will display the voltage associated with 0.0 °C. Adjust the output
voltage using the ‘UP’ and ‘DOWN’ buttons. Press the ‘NEXT’ button when the
voltage output measures 0.000 +/-0.005 VDC.
Voltage 2 Span is the fourth step; the top and second lights are on solid the next
light will blink and the bottom light is on solid.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
SOLID
BLINK
SOLID
The volt meter will display the voltage associated with 20.0 °C. Adjust the output
voltage using the ‘UP’ and ‘DOWN’ buttons. Press the ‘NEXT’ button when the
voltage output measures 1.000 +/-0.005 VDC.
Thermocouple Inputs
Thermocouple1 -20°C is the fifth step; the top and third lights are on solid and the
second and bottom lights are blinking.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
BLINK
SOLID
BLINK
The volt meter will display the maximum voltage output, approximately 3.6 VDC.
The volt meter can be disconnected.
Disconnect the thermocouple(s) from the control board. The thermocouples
should be labeled on any unit with multiple sensors to insure correct reassembly
after calibration.
Connect the thermocouple calibrator to ‘TC1’ connector CN9. Set calibrator to
-20.0°C; K thermocouple. Allow 30 seconds, 15 LED blinks, for calibrator output
and control board input to stabilize.
Press the ‘UP / TAKE’ button to record the input value. The board will
automatically move to the next step.
Thermocouple1 20°C is the sixth step; the top, third and bottom lights are on solid
and the second light is blinking.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
BLINK
SOLID
SOLID
Set calibrator to 20.0°C; K thermocouple. Allow 30 seconds, 15 LED blinks, for
calibrator output and control board input to stabilize.
Press the ‘UP / TAKE’ button to record the input value. The board will
automatically move to the next step.
Thermocouple2 -20°C is the seventh step; the top, second and third lights are on
solid and the bottom light is blinking.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
SOLID
SOLID
BLINK
Connect the thermocouple calibrator to ‘TC2’ connector CN10. Set calibrator to
-20.0°C; K thermocouple. Allow 30 seconds, 15 LED blinks, for calibrator output
and control board input to stabilize.
Press the ‘UP / TAKE’ button to record the input value. The board will
automatically move to the next step.
Thermocouple1 20°C is the eighth step; all four lights are on solid.
LED indicators in order top to bottom
CAL : CHANNEL : IN / OUT : HIGH / LOW
SOLID
SOLID
SOLID
SOLID
Set calibrator to 20.0°C; K thermocouple. Allow 30 seconds for calibrator output
and control board input to stabilize.
Press the ‘UP / TAKE’ button to record the input value.
The board will automatically move to the first step, Voltage 1 zero.
Move switch #6 to the ‘OFF’ position of the DIP Switch labeled SW1 to exit
calibration and return to operation. The front digital display will return to being
active and the back indicator LED lights not be lit. The updates are automatically
saved.
Board Configuration (Parameter Set Up)
Overview
Move switch #5 to the ‘ON’ position of the DIP Switch labeled SW1 to begin
board configuration.
The display will toggle between the label for each menu item and the value for
that specific item. The label will be displayed for 1 second followed by the value
which is displayed for 3 seconds.
Press the “Next” button to navigate through the menu items. The button will only
move to the next item. The items are displayed in a cyclical fashion so you will be
able to come back around to any item as needed.
The “UP” and “DOWN” buttons are used to adjust the value of the menu item.
The values have maximum and minimum ranges. Pressing the “UP” button when
the maximum value is displayed will change the value to the minimum value.
Conversely pressing the “DOWN” button when the minimum value is displayed
will change the value to the maximum value.
Move switch #5 to the ‘OFF’ position of the DIP Switch labeled SW1 to exit
board configuration and return to operation. The updates are automatically saved.
Single Channel Cooler with communications
DIP Switch 1, 2 and 3 are OFF, OFF and OFF.
Menu Item Display Range
Set Point 1 SP1 -10 to 25 °C
Ready 1 rd1 -10 to 25 °C
Relay Control rLY Reset or Latch
Modbus ID I d 1 to 255
Set Point 1 is the temperature the cooler will try to maintain the impinger at
during operation.
Ready 1 is the temperature that impinger must be below to turn on the relay and
external equipment (i.e. sample pump)
Relay Control determines if the control relays reset automatically or latch on
alarm. Choose “Reset”, displayed as “rSt”, to have the relays reset automatically.
Choose “Latch”, displayed as “LAt”, to have the relays latch on alarm. An
external switch is required to reset the alarms.
Modbus ID is the address used in serial communication to the unit.
Single Channel Cooler 2nd channel
DIP Switch 1, 2 and 3 are ON, OFF and OFF.
Menu Item Display Range
Set Point 1 SP1 -10 to 25 °C
Ready 1 rd1 -10 to 25 °C
Relay Control rLY Reset or Latch
Set Point 1 is the temperature the cooler will try to maintain the impinger at
during operation.
Ready 1 is the temperature that impinger must be below to turn on the relay and
external equipment (i.e. sample pump)
Relay Control determines if the control relays reset automatically or latch on
alarm. Choose “Reset”, displayed as “rSt”, to have the relays reset automatically.
Choose “Latch”, displayed as “LAt”, to have the relays latch on alarm. An
external switch is required to reset the alarms.
1St Frozen
DIP Switch 1, 2 and 3 are OFF, OFF and ON.
Menu Item Display Range
Set Point 1 SP1 -10 to 25 °C
Ready 1 rd1 -10 to 25 °C
Cycle Time CYC 1 to 18 Hours
Crossover Time Cot 15 to 45 minutes
Set Point 1 is the temperature the cooler will try to maintain the impinger at
during operation.
Ready 1 is the temperature that impinger must be below to turn on the relay and
external equipment (i.e. sample pump)
Cycle Time is the length of the frozen period for each impinger.
Crossover Time is the period of time that both impingers are active to allow the
thawed impinger to cool to freeze prior to switch over.
2nd Frozen
DIP Switch 1, 2 and 3 are OFF, OFF and ON.
Menu Item Display Range
Set Point 1 SP1 -10 to 25 °C
Ready 1 rd1 -10 to 25 °C
Set Point 1 is the temperature the cooler will try to maintain the impinger at
during operation.
Ready 1 is the temperature that impinger must be below to turn on the relay and
external equipment (i.e. sample pump)
st
Note all timing is controlled by the 1
frozen control board.
Dual Channel Cooler
DIP Switch 1, 2 and 3 are OFF, ON and OFF.
Menu Item Display Range
Set Point 1 SP1 -10 to 25 °C
Ready 1 rd1 -10 to 25 °C
Set Point 2 SP2 -10 to 25 °C
Ready 2 rd2 -10 to 25 °C
Display dSP Toggle or Switch
Water Slip UJS 1, 2 or 3
Modbus ID I d 1 to 255
Set Point 1 is the temperature the cooler will try to maintain impinger #1 at during
operation.
Ready 1 is the temperature that impinger #1 must be below to turn on the relay #1
and external equipment (i.e. sample pump)
Set Point 2 is the temperature the cooler will try to maintain impinger #1 at during
operation.
Ready 2 is the temperature that impinger #2 must be below to turn on the relay #2
and external equipment (i.e. sample pump)
Display set the method to control the channel display of data. Toggle, shown as
“toG”, will display each channel for 10 seconds constantly switch between the
two. Switch, shown as “SUJ”, will allow the user to select the channel displayed
through an external switch.
Water Slip set the relay used to alarm for water present at the Water Slip sensor.
Setting of 1 will have the water slip sensor control relay #1 with ready for channel
#1. Setting of 2 will have the water slip sensor control relay #2 with ready for
channel #2. Setting of 3 will have the water slip sensor control relay #2 alone; the
channel 2 ready alarm is ignored.
Modbus ID is the address used in serial communication to the unit.
NJ Thermocouple Display
DIP Switch 1, 2 and 3 are ON, ON and OFF.
Menu Item Display Range
Ready 1 rd1 -10 to 25 °C
Ready 2 rd2 -10 to 25 °C
Display dSP Toggle or Switch
Water Slip UJS 1, 2 or 3
Ready 1 is the temperature that impinger #1 must be below to turn on the relay #1
and external equipment (i.e. sample pump)
Ready 2 is the temperature that impinger #2 must be below to turn on the relay #2
and external equipment (i.e. sample pump)
Display set the method to control the channel display of data. Toggle, shown as
“toG”, will display each channel for 10 seconds constantly switch between the
two. Switch, shown as “SUJ”, will allow the user to select the channel displayed
through an external switch.
Water Slip set the relay used to alarm for water present at the Water Slip sensor.
Setting of 1 will have the water slip sensor control relay #1 with ready for channel
#1. Setting of 2 will have the water slip sensor control relay #2 with ready for
channel #2. Setting of 3 will have the water slip sensor control relay #2 alone; the
channel 2 ready alarm is ignored.