INSTALLATION
TW3008AR-4
Active Receiver
Eight Channels for UTP Transmission
C1668M (8/06)
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
13. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases shall be placed on the apparatus.
14. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
15. Installation should be done only by qualified personnel and conform to all local codes.
16. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
17. Use only installation methods and materials capable of supporting four times the maximum
specified load.
18. A CCC-approved power cord must be used to power this equipment when used in China.
C1668M (8/06) 3
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this
equipment can void your authority to operate this equipment under Federal Communications
Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
4 C1668M (8/06)
Description
The TW3008AR-4 is an eight-channel active receiver that can receive live video over unshielded
twisted pair (UTP) cable.
The adaptive technology in the TW3008AR-4 automatically adjusts the low, medium and high
frequency components of the video signal allowing for the best possible video transmission. The
adaptive technology eliminates the need for manual adjustment by automatically adjusting to provide
the most favorable video transmission depending on cable length needed. The unit has been
optimized for use with Cat5e and Cat6 cable, although Cat3 and Cat5 cable can be used for shorter
distances.
The front of the receiver has dials and LEDs for each of the eight channels. The dials are used for
selecting the cable distance. You can leave the dial on auto (default adaptive technology) or manually
select 1,000 feet (305 meters), 2,000 feet (610 meters), 3,000 feet (914 meters), or 4,000 feet
(1,219 meters). The LEDs light green when UTP video is being received and red when no UTP video is
being received. A flashing amber LED means that there are Coaxitron
commands being transmitted.
The back of the receiver has four BNC connectors for each channel and one UTP connector for each
channel. Only BNC A of each channel can be used for Coaxitron control. The other BNC connectors are
for connecting to other equipment, such as monitors and DVRs. The back of the unit also has a 5 mm
barrel power connector and a 6-pin Molex
and the 6-pin Molex connector can be used in a multi-unit installation with the optional
EPS5000-120TW rack-mountable external power supply.
Customers in the United States, United Kingdom, Europe, and Australia will receive one of the
following power cords: US-320-C13, UK-320-C13, EU-320-C13, and AU-320-C13.
The following features are found on the TW3008AR-4:
• Full motion color/black-white video up to 4,000 feet (1,219 meters) with Cat5e or Cat6
• Supports Coaxitron control (PTZ control signals) up to 750 feet (229 meters)
• Compatible with all Pelco twisted pair equipped cameras, enclosures, and domes
• Built-in surge suppression
• Each channel has four BNC connectors for video output
• Easy termination with a removable UTP connector for each channel
• Supports NTSC, PAL, and SECAM
• Power supply with an IEC 320-C13 socket for interchangeable AC power cords (either US, UK,
EU, AU)
• Can be mounted into a standard EIA 19-inch rack
®
power connector. The barrel connector is for desktop use
®
pan/tilt/zoom (PTZ) control
MODELS
TW3008AR-4-US Eight-channel active receiver with power cord for use in the United States
TW3008AR-4-UK Same as TW3008AR-4-US except with power cord for use in the United
TW3008AR-4-AU Same as TW3008AR-4-US except with power cord for use in Australia and New
TW3008AR-4-EU Same as TW3008AR-4-US except with power cord for use in most of
C1668M (8/06) 5
Kingdom, Ireland, and Hong Kong
Zealand
continental Europe