Sarix TI Series Camera
User Manual
C6622M
September 2019
Pelco Troubleshooting Contact Information
If the instructions provided fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international) for assistance. Be sure to have the serial number available when calling.
Do not try to repair the unit yourself. Leave maintenance and repairs to qualified technical personnel only.
Chapter 1: Important Notices Sarix TI Series Camera User Manual
List of Revisions
No. |
Date |
|
Description |
Page Number |
|
|
|
|
|
1.0 |
|
New Release |
|
All |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1-1
Chapter 1: Important Notices Sarix TI Series Camera User Manual
Table of Contents
1. |
Important Notices ............................................................................................................................. |
1-8 |
|
1.1 |
Regulatory Notices [FCC Class A]..................................................................................................... |
1-8 |
|
|
1.1.1 Radio and Television Interference............................................................................................. |
1-8 |
|
1.2 |
Legal Notice [Audio Notice]............................................................................................................... |
1-8 |
|
1.3 |
Video Quality Caution ........................................................................................................................ |
1-9 |
|
|
1.3.1 Frame Rate Notice Regarding User Selected Options............................................................... |
1-9 |
|
1.4 |
Open Source Software ........................................................................................................................ |
1-9 |
|
1.5 |
CCC Power Cord Statement ............................................................................................................... |
1-9 |
|
|
1.5.1 2.4 GHZ Radio Device ............................................................................................................ |
1-10 |
|
1.6 |
ESD Warning .................................................................................................................................... |
1-10 |
|
1.7 |
Warranty............................................................................................................................................ |
1-10 |
|
1.8 |
Network Topology Statement ........................................................................................................... |
1-10 |
|
2. |
Overview .......................................................................................................................................... |
2-13 |
|
2.1 |
Overview........................................................................................................................................... |
2-14 |
|
2.2 |
Features ............................................................................................................................................. |
2-14 |
|
2.3 |
Physical Description of the Camera.................................................................................................. |
2-15 |
|
2.4 |
Marking............................................................................................................................................. |
2-16 |
|
2.5 |
Sarix TI Web GUI............................................................................................................................. |
2-17 |
|
2.6 |
Technical Data and Specifications.................................................................................................... |
2-18 |
|
|
2.6.1 |
System Specifications.............................................................................................................. |
2-18 |
|
2.6.2 |
Configurations ......................................................................................................................... |
2-19 |
|
2.6.3 |
Thermal Camera ...................................................................................................................... |
2-20 |
|
2.6.4 |
CMOS Camera ........................................................................................................................ |
2-20 |
3. |
Safety.................................................................................................................................................. |
3-1 |
|
3.1 |
Safety Conventions ............................................................................................................................. |
3-1 |
|
3.2 |
Safety During Installation ................................................................................................................... |
3-2 |
|
3.3 |
Safety During Maintenance ................................................................................................................ |
3-2 |
|
4. |
Installation ......................................................................................................................................... |
4-1 |
|
4.1 |
Unpacking ........................................................................................................................................... |
4-1 |
|
4.2 |
Camera Installation ............................................................................................................................. |
4-2 |
|
|
4.2.1 |
Installation Guidelines and Preparation.................................................................................... |
4-2 |
|
4.2.2 |
Mechanical Interface Preparation.............................................................................................. |
4-3 |
|
4.2.3 |
Wall Mount Configuration ........................................................................................................ |
4-4 |
|
4.2.4 |
Pole Mount Configuration ......................................................................................................... |
4-5 |
|
4.2.5 Electrical ICD IP PoE Cable ..................................................................................................... |
4-6 |
|
5. |
Operation ........................................................................................................................................... |
5-1 |
|
5.1 |
First Time Credentials Setup............................................................................................................... |
5-2 |
Chapter 1: Important Notices |
Sarix TI Series Camera User Manual |
||
5.2 |
Logging Into Sarix TI Camera Web GUI........................................................................................... |
5-3 |
|
5.3 |
Changing Your Password ................................................................................................................... |
5-5 |
|
5.4 |
Main Window Overview .................................................................................................................... |
5-6 |
|
5.5 |
Live View Window ............................................................................................................................ |
5-7 |
|
5.6 |
Status Window.................................................................................................................................... |
5-8 |
|
|
5.6.1 |
System Tab................................................................................................................................ |
5-9 |
|
5.6.2 |
Thermal Tab ............................................................................................................................ |
5-10 |
|
5.6.3 |
Day Tab................................................................................................................................... |
5-12 |
|
5.6.4 |
Disabling / Enabling a Camera ............................................................................................... |
5-13 |
5.7 |
Network Window ............................................................................................................................. |
5-15 |
|
|
5.7.1 |
Setting of IP Address .............................................................................................................. |
5-16 |
|
5.7.2 |
Setting an Auto IP Address (DHCP)....................................................................................... |
5-16 |
|
5.7.3 |
Setting a Manual DNS Server Address................................................................................... |
5-17 |
|
5.7.4 |
Settings of HTTPS Connection............................................................................................... |
5-17 |
|
5.7.5 |
Setting the Network Interface ................................................................................................. |
5-17 |
|
5.7.6 |
Resetting Network Settings..................................................................................................... |
5-18 |
|
5.7.7 |
Restarting ONVIF Service ...................................................................................................... |
5-18 |
|
5.7.8 |
Certificates .............................................................................................................................. |
5-19 |
5.8 |
Streaming Window ........................................................................................................................... |
5-21 |
|
|
5.8.1 |
Thermal Tab ............................................................................................................................ |
5-21 |
|
5.8.2 |
Day Tab................................................................................................................................... |
5-25 |
|
5.8.3 |
General Configuration Tab ..................................................................................................... |
5-28 |
5.9 |
Image Processing Window ............................................................................................................... |
5-29 |
|
|
5.9.1 |
Thermal Tab ............................................................................................................................ |
5-29 |
|
5.9.2 |
Day Tab................................................................................................................................... |
5-37 |
5.10 |
Analytics Window ............................................................................................................................ |
5-41 |
|
|
5.10.1 Regions Tab ............................................................................................................................ |
5-42 |
|
|
5.10.2 |
Ignore Regions Tab ................................................................................................................. |
5-46 |
|
5.10.3 |
Learning Tab ........................................................................................................................... |
5-48 |
|
5.10.4 |
Analytics Settings.................................................................................................................... |
5-49 |
5.11 |
System Window................................................................................................................................ |
5-51 |
|
|
5.11.1 Admin Tab .............................................................................................................................. |
5-51 |
|
|
5.11.2 Logs Tab.................................................................................................................................. |
5-57 |
|
|
5.11.3 Date and Time Tab.................................................................................................................. |
5-58 |
|
|
5.11.4 |
File Upload Tab....................................................................................................................... |
5-60 |
|
5.11.5 User Management Tab ............................................................................................................ |
5-60 |
|
5.12 |
Logging Out from the Web GUI ...................................................................................................... |
5-62 |
|
6. |
Maintenance .................................................................................................................................... |
6-63 |
|
6.1 |
Visual Inspection .............................................................................................................................. |
6-63 |
|
6.2 |
Cleaning............................................................................................................................................ |
6-63 |
|
7. |
Ordering Information .................................................................................................................... |
7-64 |
|
|
|
|
|
1-3 |
|
|
|
Chapter 1: Important Notices |
Sarix TI Series Camera User Manual |
|
7.1 |
Ordering Information ........................................................................................................................ |
7-64 |
7.2 |
Ordering Accessories ........................................................................................................................ |
7-64 |
8. |
Index................................................................................................................................................. |
8-65 |
Chapter 1: Important Notices Sarix TI Series Camera User Manual
List of Figures
Figure 2-1: |
Sarix TI Camera General View .......................................................................................... |
2-14 |
Figure 2-2: |
Physical Description of the Camera ................................................................................... |
2-15 |
Figure 2-3: |
Sarix TI Label..................................................................................................................... |
2-16 |
Figure 2-4: |
Sarix TI Web GUI .............................................................................................................. |
2-17 |
Figure 4-1: |
Sarix TI Camera Package General View.............................................................................. |
4-1 |
Figure 4-2: |
Mechanical Interface Preparation - Camera Dimensions..................................................... |
4-3 |
Figure 4-3: |
Camera Installation - Wall Mount Configuration ................................................................ |
4-4 |
Figure 4-4: |
Camera Installation - Pole Mount Configuration ................................................................. |
4-5 |
Figure 4-5: |
Electrical ICD IP PoE Cable ................................................................................................ |
4-6 |
Figure 5-1: |
Sarix TI Web GUI – First Time Setup ................................................................................. |
5-2 |
Figure 5-2: |
Sarix TI Web GUI - Status Window (before Login)............................................................ |
5-3 |
Figure 5-3: |
Login Window...................................................................................................................... |
5-3 |
Figure 5-4: |
Login Window – Entering Username and Password............................................................ |
5-4 |
Figure 5-5: |
Sarix TI Web GUI - Status Window (after Login)............................................................... |
5-4 |
Figure 5-6: |
Changing Your Password - Drop Down Menu .................................................................... |
5-5 |
Figure 5-7: |
Sarix TI Web GUI - Changing Your Password.................................................................... |
5-5 |
Figure 5-8: |
Main Window Overview - Main Areas................................................................................ |
5-6 |
Figure 5-9: |
Live View Window (example) ............................................................................................. |
5-7 |
Figure 5-10: |
Status Window (all collapsed).............................................................................................. |
5-8 |
Figure 5-11: |
Status Window - System Tab ............................................................................................... |
5-9 |
Figure 5-12: |
Status Window - Thermal Tab ........................................................................................... |
5-10 |
Figure 5-13: |
Status Window - Day Tab .................................................................................................. |
5-12 |
Figure 5-14: |
Disabling / Enabling a Camera - System Reboot ............................................................... |
5-13 |
Figure 5-15: |
Disabling / Enabling a Camera - System Reboot Approval ............................................... |
5-14 |
Figure 5-16: |
Network Window - Basic Settings Tab.............................................................................. |
5-15 |
Figure 5-17: |
Network Window - Changing an Address.......................................................................... |
5-16 |
Figure 5-18: |
Network Window - Setting Network Interface .................................................................. |
5-17 |
Figure 5-19: |
Network Window - Resetting IP Address Approval .......................................................... |
5-18 |
Figure 5-20: |
Network Window - ONVIF Reload ................................................................................... |
5-18 |
Figure 5-21: |
Certificates - Creating a Certificate Request ...................................................................... |
5-19 |
Figure 5-22: |
Certificates - Generating a Self-Signed Certificate ............................................................ |
5-19 |
Figure 5-23: |
Certificates - Uploading a Certificate................................................................................. |
5-20 |
Figure 5-24: |
Streaming Window - Thermal Tab..................................................................................... |
5-21 |
Figure 5-25: |
Streaming Window - Thermal Tab - Main Stream............................................................. |
5-22 |
Figure 5-26: |
Streaming Window - Thermal Tab - Secondary Stream .................................................... |
5-24 |
Figure 5-27: |
Streaming Window - Day Tab - Main Stream.................................................................... |
5-25 |
Figure 5-28: |
Streaming Window - Day Tab - Secondary Stream ........................................................... |
5-27 |
Figure 5-29: |
Streaming Window - General Configuration Tab .............................................................. |
5-28 |
Figure 5-30: |
Image Processing Window - Thermal Tab......................................................................... |
5-29 |
Figure 5-31: |
Image Processing Window - Thermal Tab - Basic Settings............................................... |
5-30 |
Figure 5-32: |
Image Processing Window - Thermal Tab - Signal Processing Settings ........................... |
5-31 |
|
|
|
1-5 |
|
|
Chapter 1: Important Notices |
Sarix TI Series Camera User Manual |
|
Figure 5-33: Image Processing Window - Thermal Tab - Gain Control Settings ................................... |
5-32 |
|
Figure 5-34: Image Processing Window - Thermal Tab - Advanced Settings........................................ |
5-33 |
|
Figure 5-35: Image Processing Window - Thermal Tab - Color Processing Settings............................. |
5-34 |
|
Figure 5-36: Image Processing Window - Histogram Calculation ROI (1 of 3)..................................... |
5-34 |
|
Figure 5-37: Image Processing Window - Histogram Calculation ROI (2 of 3)..................................... |
5-35 |
|
Figure 5-38: Image Processing Window - Histogram Calculation ROI (3 of 3)..................................... |
5-36 |
|
Figure 5-39: Image Processing Window - Day Tab ................................................................................ |
|
5-37 |
Figure 5-40: Image Processing Window - Day Tab - Geometry Settings............................................... |
5-38 |
|
Figure 5-41: Image Processing Window - Day Tab - Misc Properties Settings...................................... |
5-39 |
|
Figure 5-42: Analytics Window (all collapsed)....................................................................................... |
|
5-41 |
Figure 5-43: Analytics Window - Regions Tab....................................................................................... |
|
5-42 |
Figure 5-44: Analytics Window - Regions Tab - Region Options .......................................................... |
|
5-43 |
Figure 5-45: Analytics Window - Regions Tab - Area ROI.................................................................... |
|
5-45 |
Figure 5-46: Analytics Window - Regions Tab - Fence ROI.................................................................. |
|
5-45 |
Figure 5-47: Analytics Window - Ignore Regions Tab ........................................................................... |
|
5-46 |
Figure 5-48: Analytics Window - Ignore Regions Tab – Ignore Regions ROI (1 of 2).......................... |
5-47 |
|
Figure 5-49: Analytics Window - Ignore Regions Tab – Ignore Regions ROI (2 of 2).......................... |
5-47 |
|
Figure 5-50: Analytics Window - Learning Tab ..................................................................................... |
|
5-48 |
Figure 5-51: Analytics Window - Analytics Settings.............................................................................. |
|
5-49 |
Figure 5-52: System Window - Admin Tab ............................................................................................ |
|
5-51 |
Figure 5-53: System Window - Admin Tab - Restart Aproval ............................................................... |
|
5-51 |
Figure 5-54: System Window - Admin Tab - Restart.............................................................................. |
|
5-52 |
Figure 5-55: System Window - Admin Tab - Archive System Files ...................................................... |
|
5-52 |
Figure 5-56: System Window - Admin Tab - Save As Site Approval .................................................... |
|
5-53 |
Figure 5-57: System Window - Admin Tab - Save As Site .................................................................... |
|
5-53 |
Figure 5-58: System Window - Admin Tab - Export Site Approval....................................................... |
|
5-54 |
Figure 5-59: System Window - Admin Tab - Site Defaults Approval .................................................... |
|
5-54 |
Figure 5-60: System Window - Admin Tab - Site Defaults .................................................................... |
|
5-55 |
Figure 5-61: System Window - Admin Tab - Factory Defaults Approval .............................................. |
5-55 |
|
Figure 5-62: System Window - Admin Tab - Factory Defaults .............................................................. |
|
5-56 |
Figure 5-63: System Window - Logs Tab ............................................................................................... |
|
5-57 |
Figure 5-64: System Window - Date and Time Tab................................................................................ |
|
5-58 |
Figure 5-65: System Window - Date and Time Tab - Synchronizing with Browser Time..................... |
5-59 |
|
Figure 5-66: System Window - Date and Time Tab - Synchronizing with NTP .................................... |
5-59 |
|
Figure 5-67: System Window - File Upload Tab .................................................................................... |
|
5-60 |
Figure 5-68: System Window - User Management Tab.......................................................................... |
|
5-60 |
Figure 5-69: System Window - User Management Tab - Adding a User ............................................... |
5-61 |
|
Figure 5-70: System Window - User Management Tab - Editing User Details...................................... |
5-62 |
|
Figure 5-71: Logging Out from the Web GUI - Drop Down Menu........................................................ |
|
5-62 |
Chapter 1: Important Notices Sarix TI Series Camera User Manual
List of Tables
Table 2-1: |
Technical Data and Specifications - System Specifications............................................... |
2-18 |
Table 2-2: |
Technical Data and Specifications - Configurations.......................................................... |
2-19 |
Table 2-3: |
Technical Data and Specifications - Thermal Camera ....................................................... |
2-20 |
Table 2-4: |
Technical Data and Specifications - CMOS Camera ......................................................... |
2-20 |
Table 4-1: |
Electrical ICD IP PoE Cable - Pinout................................................................................... |
4-6 |
Table 7-1: |
Ordering Information for 30Hz Camera............................................................................. |
7-64 |
Table 7-2: |
Ordering Information for 9Hz Camera............................................................................... |
7-64 |
Table 7-3: |
Ordering Accessories.......................................................................................................... |
7-64 |
1-7
Chapter 1: Important Notices |
Sarix TI Series Camera User Manual |
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
To maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
SOME PELCO EQUIPMENT CONTAINS, AND THE SOFTWARE ENABLES, AUDIO/VISUAL AND RECORDING CAPABILITIES, THE IMPROPER USE OF WHICH MAY SUBJECT YOU TO CIVIL AND CRIMINAL PENALTIES. APPLICABLE LAWS REGARDING THE USE OF SUCH CAPABILITIES VARY BETWEEN JURISDICTIONS AND MAY REQUIRE, AMONG OTHER THINGS, EXPRESS WRITTEN CONSENT FROM RECORDED SUBJECTS. YOU ARE SOLELY RESPONSIBLE FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR STRICT ADHERENCE TO ANY/ALL RIGHTS OF PRIVACY AND PERSONALTY. USE OF THIS EQUIPMENT AND/OR SOFTWARE FOR ILLEGAL SURVEILLANCE OR MONITORING SHALL BE DEEMED UNAUTHORIZED USE IN VIOLATION OF THE END USER SOFTWARE
Chapter 1: Important Notices |
Sarix TI Series Camera User Manual |
AGREEMENT AND RESULT IN THE IMMEDIATE TERMINATION OF YOUR LICENSE RIGHTS THEREUNDER.
Pelco systems are capable of providing high quality video for both live viewing and playback. However, the systems can be used in lower quality modes, which can degrade picture quality, to allow for a slower rate of data transfer and to reduce the amount of video data stored. The picture quality can be degraded by either lowering the resolution, reducing the picture rate, or both. A picture degraded by having a reduced resolution may result in an image that is less clear or even indiscernible. A picture degraded by reducing the picture rate has fewer frames per second, which can result in images that appear to jump or move more quickly than normal during playback. Lower frame rates may result in a key event not being recorded by the system.
Judgment as to the suitability of the products for users' purposes is solely the users' responsibility. Users shall determine the suitability of the products for their own intended application, picture rate and picture quality. In the event users intend to use the video for evidentiary purposes in a judicial proceeding or otherwise, users should consult with their attorney regarding any particular requirements for such use.
This product includes certain open source or other software originated from third parties that is subject to the GNU General Public License (GPL), GNU Library/Lesser General Public License (LGPL) and different and/or additional copyright licenses, disclaimers, and notices.
The exact terms of GPL, LGPL, and some other licenses are provided to you with this product. Please refer to the exact terms of the GPL and LGPL at http://www.fsf.org (Free Software Foundation) or http://www.opensource.org (Open Source Initiative) regarding your rights under said license. You may obtain a complete corresponding machine-readable copy of the source code of such software under the GPL or LGPL by sending your request to digitalsupport@pelco.com; the subject line should read Source Code Request. You will then receive an email with a link for you to download the source code.
This offer is valid for a period of three (3) years from the date of the distribution of this product by Pelco.
Models shipped to China do not include power cords.
1-9
Chapter 1: Important Notices |
Sarix TI Series Camera User Manual |
NOTE
A CCC approved power cord must be used to power the equipment when used in China
WARNING: This product is sensitive to Electrostatic Discharge (ESD). To avoid ESD damage to this product, use ESD safe practices during installation. Before touching, adjusting or handling this product, correctly attach an ESD wrist strap to your wrist and appropriately discharge your body and tools. For more information about ESD control and safe handling practices of electronics, please refer to ANSI/ESD S20.20-1999 or contact the Electrostatic Discharge Association (www.esda.org).
For information about Pleco's product warranty and thereto related information, refer to www.pelco.com/warranty.
IMPORTANT NOTE. PLEASE READ. The network implementation is shown as a general representation only and is not intended to show a detailed network topology. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the system as illustrated. Please contact your local Pelco representative to discuss your specific requirements.
Chapter 1: Important Notices Sarix TI Series Camera User Manual
List of Acronyms and Abbreviations
AWG: |
American Wire Gauge |
NUC: |
Non-Uniformity Correction |
CBR: |
Constant Bit Rate |
NV: |
Night Vision |
Histogram: |
Accurate representation of the |
ONVIF: |
Open Network Video Interface Forum |
|
distribution of numerical data. |
|
|
CE: |
Comminute European |
P/N: |
Part Number |
CMOS: |
Complementary Metal-Oxide |
PoE: |
Power Over Ethernet |
|
Semiconductor |
|
|
DC: |
Direct Current |
QVGA+: |
Quarter Video Graphics Array (384 ×288) |
DFPA: |
Digital Focal Plan Array |
RH: |
Relative Humidity |
DHCP: |
Dynamic Host Configuration Protocol |
ROI: |
Region Of Interest |
DNS: |
Domain Name System |
RTN: |
Return |
FCC: |
Federal Communications Commission |
RTP: |
Real Time Protocol |
I-frame: |
Infra-coded frame |
RTSP: |
Real-Time Streaming Protocol |
FM: |
Firmware |
S/N: |
Serial Number |
FOV: |
Field Of View |
SDK: |
Software Development Kit |
FPS: |
Frames Per Second |
VMS: |
Video Management System |
GND: |
Ground |
SSL: |
Secure Sockets Layer |
GOP: |
Group of Pictures |
SW: |
Software |
GUI: |
Graphical User Interface |
TCP: |
Transmission Control Protocol |
HD: |
High Definition |
TINT: |
Time Integration |
HTTP: |
Hypertexts Transfer Protocol |
TLS: |
Transport Layer Security |
HTTPS: |
HyperText Transfer Protocol Secure |
URI: |
Uniform Resource Indicator |
IEEE: |
Institute of Electrical and Electronics |
V bus |
CTIA reference voltage |
|
Engineers |
|
|
IP: |
Internet Protocol |
VBR: |
Variable Bit Rate |
IR: |
Infrared |
VDC: |
Volts, Direct Current |
JPEG: |
Joint Photographic Expert Group |
VDDA: |
Analog supply fixed |
LAN: |
Local Area Network |
VGA: |
Video Graphics Array (640 × 480) |
MAC: |
Media Access Control |
VGSK: |
Compensation microbolometer - transistor |
|
|
|
gate voltage |
mK: |
milli-Kelvin |
WWW: |
World Wide Web |
NETD: |
Noise Equivalent Temperature |
Pipeline: |
data processing elements, connected in |
|
Difference |
|
series, where the output of one element |
|
|
|
is the input of the next one. |
|
|
|
|
1-11 |
|
|
|
Chapter 1: Important Notices |
Sarix TI Series Camera User Manual |
Scope of This Manual
This manual provides the necessary information for introducing, installing, operating and maintaining the Sarix TI Series Camera.
The manual in intended for use by technicians and operators and consists of the following chapters:
Chapter 2: Overview:
Introduces the Sarix TI Series Camera and its web GUI features.
Chapter 3: Safety:
Provides safety instructions that technicians should be aware of during the installation, operation and maintenance of the Sarix TI Series Camera.
Chapter 4: Installation:
Provides instructions for installing the Sarix TI Series Camera.
Chapter 5: Operation:
Provides operating instructions for the Sarix TI Series Camera web GUI.
Chapter 6: Maintenance:
Provides the Sarix TI Series Camera preventive maintenance instructions.
Chapter 7: Ordering Information:
Provides information for purchasing the Sarix TI Series Camera and accessories.
Index:
Provides a list, arranged in alphabetical order, of keywords found throughout this manual.
Chapter 2: Overview |
Sarix TI Series Camera User Manual |
This chapter introduces the Sarix TI Series Camera and its web GUI features.
The chapter consists of the following sections:
Section 2.1: Overview
Section 2.2: Features
Section 2.3: Physical Description of the Camera
Section 2.5: Sarix TI Web GUI
Section 2.6: Technical Data and Specifications
2-13
Chapter 2: Overview |
Sarix TI Series Camera User Manual |
Sarix TI Camera is a state of the art observation system, boasting an incredibly easy installation with thermal and visual capabilities. The Sarix TI line of cameras is a broad portfolio of high performance outdoor rated cameras for 24/7 perimeter surveillance, observation, and monitoring of critical infrastructure and sensitive sites.
Equipped with thermal and visible-light channels, the Sarix TI meets global Open Network Video Interface Forum (ONVIF) standards to ensure interoperability of hardware and software products for easy integration to both existing and new infrastructures, regardless of manufacturer.
The Sarix TI is ruggedly designed to withstand the harshest weather and environmental conditions, including rain, direct sunlight, high humidity, dust, heat, and cold.
The Sarix TI uses new and innovative open uncooled 17μ 640 x 480 or 384 x 288 resolution thermal core and video enhancement algorithm.
Figure 2-1: Sarix TI Camera General View
Both visible and Video Graphics Array (VGA) thermal channels
ONVIF Profile S compliant
Easy installation
Advanced optics
Low cost of ownership
Best support for analytics
Rugged design
Enhanced image processing
Chapter 2: Overview |
Sarix TI Series Camera User Manual |
The Sarix TI Camera outer components include (see Figure 2-2):
1.Infrared (IR) Camera Lens
2.Main Connector (Power and Ethernet)
3.Camera-to-Pole Mount Adapter fastening screws (x4)
4.Tripod mount fastening screw
5.Complementary Metal-Oxide Semiconductor (CMOS) Camera Lens (module depended).
Figure 2-2: Physical Description of the Camera
1
2 3 (x4)
Bottom View
5 |
4 |
2-15
Chapter 2: Overview |
Sarix TI Series Camera User Manual |
The camera us marked with a label as shown below:
Figure 2-3: Sarix TI Label
NOTE: For reference only
Chapter 2: Overview |
Sarix TI Series Camera User Manual |
The operation of the Sarix TI Camera is performed via Web Graphical User Interface (GUI). With the GUI you can:
Setup the camera operation.
Optimize the camera video.
Communicate with Video Management Systems (VMS).
Figure 2-4: Sarix TI Web GUI
2-17
Chapter 2: Overview |
Sarix TI Series Camera User Manual |
Applicable to models :Sarix TI 14.2mm, 35mm, and 50mm.
Table 2-1: |
Technical Data and Specifications - System Specifications |
||
Thermal Camera: |
Imager Type: |
Uncooled ASi Microbolometer |
|
|
|
|
|
|
Spectral Band: |
7.5 - 14µ |
|
|
|
|
|
|
Pixel Size: |
17µ |
|
|
|
|
|
|
Resolution: |
640 x 480 (VGA) or 384 x 288 (QVGA) |
|
|
|
|
|
|
NETD: |
VGA: < 40° mk, QVGA+: < 70° mk |
|
|
|
|
|
Day Camera: |
Imager Type: |
¼" CMOS |
|
|
|
|
|
|
Resolutions: |
640 x 480, 1024 x 768, or 1280 x 768 |
|
|
|
|
|
|
Field of View: |
54° (H) x 42° (V) @ 1024 x 768 |
|
|
|
|
|
|
S/N Ratio: |
36dB |
|
|
|
|
|
Video: |
Dual Channel: |
2 channels IP video |
|
|
|
|
|
|
Compression: |
H.264, Motion JPEG |
|
|
|
|
|
|
Frame Rate: |
8.3Hz or 25Hz |
|
|
|
|
|
|
Streaming: |
RTSP, Unicast, Multicast |
|
|
|
|
|
|
Image Settings: |
Brightness, Sharpness, Contrast, Rotation: 0°, 90°, |
|
|
|
|
180°, 270° Horizontal and Vertical Flip |
Power |
Power Input: |
12 - 32VDC or Power over Ethernet (IEEE |
|
Requirements: |
|
|
802.3af/802.3at) |
|
Consumption: |
7W typical, 20W max. (based on DC voltage) |
|
|
|
|
|
Environmental: |
Storage Temp: |
-40°C to +71°C (-40° F to +160° F) |
|
|
|
|
|
|
Operating Temp: |
-40°C to +55°C (-40° F to +131° F) |
|
|
|
|
|
|
Humidity: |
+40°C, 95% RH |
|
|
|
|
|
|
Rating: |
IP66 (NEMA 4X equivalent) |
|
|
|
|
|
Mechanical |
Dimensions: |
- 135mm (w), 202mm (d), 169mm (h) |
|
Parameters: |
|
|
- 5.32" (w), 7.95" (d), 6.65" (h) |
|
|
|
|
|
Weight: |
- 14 and 35mm: 2.2kg, |
|
|
|
|
- 50mm: 2.4kg, |
|
|
|
|
System |
Interfaces: |
ONVIF Profile S, Web GUI |
|
Integration: |
|
|
|
Chapter 2: Overview |
|
|
|
Sarix TI Series Camera User Manual |
||||
|
|
|
|
|
|
|
|
|
|
Network: |
|
Default IP: |
192.168.0.20 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
RTSP Port: |
8554 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Protocols: |
IPv4, HTTP, HTTPS, SSL/TLS, RTSP, DHCP |
|
||
|
|
|
|
|
|
|
|
|
|
Certifications: |
|
- CE |
|
EN 55032:12; |
|
|
|
|
|
|
|
- FCC |
EN 55024:2010+A1:2015; |
|
||
|
|
|
|
EN 50130-4:11+A1:14; |
|
|||
|
|
|
|
- IP66 |
|
|||
|
|
|
|
EN 61000-3-2:14; |
|
|
||
|
|
|
|
- UL and cUL |
EN 61000-3-3:13; |
|
|
|
|
|
|
|
EN 60950-1:06+A11:09+A1:10+A12:11+A2:13 |
|
|||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
UL 60950-1 2nd edition; |
|
|
|
|
|
|
|
|
CAN/CSA-C22.2 No. 60950-1:07+Amend 1:2011 |
|
|
|
|
|
|
|
|
IEC 60950-1:05+A1:09+A2:13; |
|
|
|
|
|
|
|
|
IEC 60950-22:16 |
|
|
|
|
|
|
|
|
|
|
|
2.6.2 |
Configurations |
|
|
|
|
|||
|
|
Table 2-2: |
Technical Data and Specifications - Configurations |
|||||
|
|
|
|
|
Day/Night |
|
Day |
|
|
|
|
|
|
|
|||
|
Configuration Type |
|
Thermal Camera & Lens |
Camera & Lens |
|
|||
|
|
|
|
|
|
|
|
|
|
VGA |
|
|
|
17μ 640 x 480 Athermalized |
¼" Colour HD CMOS 1280 x 720 |
|
|
|
|
|
|
|
Uncooled Thermal |
Autofocus |
|
|
|
QVGA+ |
|
17μ 384 x 288 Athermalized |
|
|
|||
|
|
|
|
|
Uncooled Thermal |
|
|
2-19
Chapter 2: Overview |
Sarix TI Series Camera User Manual |
Table 2-3: Technical Data and Specifications - Thermal Camera |
|||||
|
Configuration |
TI2X14 |
TI2X35 |
TI2X50 |
|
|
|
|
|
|
|
|
Thermal Type |
|
Uncooled |
|
|
|
|
|
|
||
|
Thermal Core |
17µ 640 x 480 (VGA) or |
|
||
|
|
17µ 384 x 288 (QVGA+) |
|
||
|
Lens Type |
Athermalized, Fixed Focus |
|
||
|
|
|
|
|
|
|
Focal Length |
14.2mm |
35mm |
50mm |
|
|
|
|
|
|
|
|
Lens F # |
f/1.2 |
f/1.2 |
f/1.2 |
|
|
|
|
|
|
|
|
Horizontal FOV - VGA |
42.1° |
17.6° |
12.4° |
|
|
|
|
|
|
|
|
Horizontal FOV - QVGA+ |
25.7° |
10.6° |
7.5° |
|
|
|
|
|
|
|
|
Video Type |
H.264, Motion JPEG (25Hz |
|
||
|
|
|
or 9Hz) |
|
|
|
Spectral Band |
Spectral Band 7.5 - 14µ |
|
||
|
|
|
|
||
|
NETD |
< 40° mk (VGA), < 70° mk |
|
||
|
|
|
(QVGA+) |
|
|
|
Digital Zoom |
|
1x, 2x, 4x |
|
|
|
|
|
|
||
|
Control Operation |
Polarity, NUC, Image Flip, |
|
||
|
|
Image Rotation & Digital |
|
||
|
|
|
Zoom |
|
|
2.6.4 |
CMOS Camera |
|
|
|
|
|
Table 2-4: |
Technical Data and Specifications - CMOS Camera |
|
|
Imager Type: |
|
1/4" Colour HD CMOS |
|
|
|
|
||
|
Effective Pixels / Resolutions: |
640 x 480 or 1024 x 768 or 1280 x 720 |
||
|
|
|
|
|
|
Lens Type: |
|
Autofocus |
|
|
|
|
|
|
|
Imager FOV (H x V): |
|
54° x 42° |
|
|
|
|
|
|
|
S/N Ratio: |
|
36dB |
|
|
|
|
|
|
|
Additional Features: |
|
Configurable Resolutions, Digital Zoom |
|
|
|
|
|
|
Chapter 3: Safety |
Sarix TI Series Camera User Manual |
This chapter provides safety instructions that technicians should be aware of during the installation, operation and maintenance of the Sarix TI Series Camera.
The chapter consists of the following sections:
Section 3.1: Safety Conventions
Section 3.2: Safety During Installation
Section 3.3: Safety During Maintenance
In this manual, safety information is presented as warnings, cautions, and notes.
WARNING
An operating procedure, practice, and so forth, which if not correctly followed, could result in personal injury or loss of life.
CAUTION
An operating procedure, practice, and so forth, which if not strictly observed, could result in damage to, or destruction of equipment.
NOTE
An operating procedure, practice, and so forth that is essential to highlight.
All procedures in this manual must be performed in accordance with the applicable local regulations.
All local safety regulations apply. If the instructions in any section of this manual contradict those of the applicable local regulations, the instructions of the applicable local regulations will prevail.
3-1
Chapter 3: Safety |
Sarix TI Series Camera User Manual |
To avoid injuries, follow standard safety regulations if mounting the Sarix TI Camera on an elevated location.
Warranty void if opening the Sarix TI camera.
Do not touch the Sarix TI Camera optics with bare hands.
Do not use any chemicals for cleaning the Sarix TI Camera. Use only wipes approved for optical equipment. Failure to comply could result in damage to the Sarix TI Camera opticallens and/or its surfaces.
3-2
Chapter 4: Installation |
Sarix TI Series Camera User Manual |
This chapter provides instructions for installing the Sarix TI Series Camera.
The chapter consists of the following sections:
Section 4.1: Unpacking
Section 4.2: Camera Installation
A standard package contains the following:
Sarix TI Camera
18-pin round female cable-connector
Ferrite
Washer Lock
Screw 6-32NCX1/4" SOC HD SS
Terminal lug ring 16AWG stub size 6
Package
Figure 4-1: Sarix TI Camera Package General View
4-1
Chapter 4: Installation |
Sarix TI Series Camera User Manual |
NOTE
Opening the Sarix TI Camera enclosure will void the product warranty.
CAUTION
Avoid pointing the Sarix TI Camera at the sun.
Prepare your self-made IP PoE cable (cables are available for purchase, see Table 7-3 for information).
4.2.1.1Cable wires between camera and DC/PoE power supply should be 20-22AWG.
4.2.1.2Both the camera ant the end-equipment connected to it should be permanently connected to protective earth, using screw and washers. Wires should be made of cupper. Minimal grounding cable is 14AWG.
(1)The cables should be protected by fuse with maximal current of 3A
(2)The output current shall not exceed 3A after 60s
(3)The maximal output current of the power supply shall not exceed 7.5A
4-2
Chapter 4: Installation |
Sarix TI Series Camera User Manual |
NOTE
It is recommended to check the functioning of the Sarix TI Camera prior to the actual installation.
Figure 4-2 depicts the camera dimensions and mechanical interfaces.
Figure 4-2: Mechanical Interface Preparation - Camera Dimensions
4-3
Chapter 4: Installation |
Sarix TI Series Camera User Manual |
An arm for wall-mount is available for purchase (see Table 7-3 for information). The dimensions of the arm are given in Figure 4-3:
Figure 4-3: Camera Installation - Wall Mount Configuration
4-4
Chapter 4: Installation |
Sarix TI Series Camera User Manual |
An adapter for pole-mount is available for purchase (see Table 7-3 for information).
The dimensions of the device are given in Figure 4-4 (note that the arm for wall-mount is required, as well):
Figure 4-4: Camera Installation - Pole Mount Configuration
4-5
Chapter 4: Installation |
Sarix TI Series Camera User Manual |
4.2.5Electrical ICD IP PoE Cable
The cable is available for purchase (see Table 7-3 for information).
Cable Pinout (see Figure 4-5):
Table 4-1: Electrical ICD IP PoE Cable - Pinout
|
Connector Pin # |
Connector Pin # |
Signal Name |
|
|
P1 |
|
P2 (RJ45) |
|
Ethernet\POE |
2 |
|
1 |
ETH RX+ |
|
6 |
|
2 |
ETH RX- |
|
11 |
|
3 |
ETH TX+ |
|
15 |
|
6 |
ETH TX- |
|
12 |
|
5,4 |
POE + |
|
14 |
|
7,8 |
POE - |
DC Power Input |
8 |
|
P.S (-) |
12-32vDC RTN |
9 |
|
P.S (+) |
12-32vDC |
|
|
|
|||
Shield |
Camera body |
|
GND Stud |
Shield |
|
Figure 4-5: |
Electrical ICD IP PoE Cable |
4-6