INSTALLATION
TW3004AR Active Receiver
Four Channels for UTP Transmission
C1667M (6/06)
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
WARNING:
15. or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
19. A CCC-approved power cord must be used to power this equipment when used in China.
To reduce the risk of fire or electric shock, do not expose this apparatus to rain
C1667M (6/06) 3

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
4 C1667M (6/06)

Description

The TW3004AR is a four-channel active receiver that can receive live video over unshielded twisted pair (UTP) cable.
The adaptive technology in the TW3004AR automatically adjusts the low, medium, and high frequency components of the video signal, allowing for the best possible video transmission. The adaptive technology eliminates the need for manual adjustment by automatically adjusting to provide the most favorable video transmission depending on cable length needed. The unit has been optimized for use with Cat5e and Cat6 cable, although Cat3 and Cat5 cable can be used for shorter distances.
The bottom of the TW3004AR has four DIP switches, one for each channel. Each DIP switch has fi ve small switches, four of which can be used to override the adaptive technology by manually selecting the cable distance. Switches 2, 3, 4, and 5 can be set to 1,000 feet (305 meters), 2,000 feet (610 meters), 3,000 feet (914 meters), and 4,000 feet (1,219 meters), respectively . Switch 1 can be set to high mode and low mode.
The four LEDs on the front of the unit indicate the status of each channel. When an LED lights red there is no UTP video being received. A green light means there is UTP video being received. A flashing amber light means that there are Coaxitron transmitted. The blue Pelco badge indicates there is power, whether you are using the 4-pin rack power connector or the 2-pin power connector.
The following features are found on the TW3004AR:
Full motion color/black and white video up to 4,000 feet (1,219 meters) with Cat5e or Cat6
Supports Coaxitron control (PTZ control signals) up to 750 feet (229 meters)
Compatible with all Pelco twisted-pair-equipped cameras, enclosures, and domes
Built-in surge suppression
Easy termination with removable UTP connector
Supports NTSC, PAL, and SECAM
Can be mounted into a Pelco fiber rack, wall mount base kit, or wall clip
®
pan/tilt/zoom (PTZ) control commands being
C1667M (6/06) 5

PARTS OF THE RECEIVER

v
FRONT BACK
BOTTOM
Figure 1.
Rubber Feet (4):
Status LEDs (4):
is UTP video being received. Flash amber when Coaxitron pan/tilt/zoom (PTZ) control commands are being received.
Pelco Badge:
or the 2-pin power connector.
Rack Power Connector:
Power Connector (3.5 mm):
UTP Connector:
BNC Connectors (4):
DIP Switches (4):
distance (1,000-4,000 feet or 305-1,219 meters). Switch 1 on each DIP switch is used for selecting high mode or low mode.
6 C1667M (6/06)
For placing unit on a flat surface, such as a desk or shelf.
Light red when there is no UTP video being received. Light green when there
Lights blue to indicate power when using either the 4-pin rack power connector
4-pin, power from RK5000PS-3U.
8-pin connector with removable mating connector.
Coaxial output.
Override the adaptive technology with the manual selection of cable
TW3004AR Parts
2-pin; stand-alone power, 12 VDC or 24 VAC.