TI57 Thermal Insulation
for EH5700 Series Enclosures
Installation/Operation
Manual C1433M (6/95)
1.0 WARNINGS
Prior to installation and use of this product, the following
WARNINGS should be observed.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be
installed where exposed to rain and moisture.
3. Only use replacement parts recommended by
PELCO.
4. After replacement/repair of this unit’s electrical
components, conduct a resistance measurement
between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
2.0 SCOPE
The information contained in this manual covers the
TI57 Thermal Insulation Kit Installation.
2.1 DESCRIPTION
The TI57 Thermal Insulation Kit provides an improved
resistance to heat loss through the body of the enclosure
by adding a 1/4-inch thick polyurethane insulation to
the majority of the internal surfaces.
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827
3.0 TI57 THERMAL INSULATION
NOTE: The camera mounting sled must be
removed for proper installation of the thermal
insulation, therefore, it should be done prior to
the enclosure installation. (- 1, -2, -3; heater/
blower/wiper kits must be removed prior to thermal insulation installation.)
4. Remove the adhesive backing, and carefully lay the
insulation in the body of the enclosure, pressing
firmly, taking care not to crease the insulation.
5. The insulation is very soft and will conform as needed
during the installation of the camera and lens.
3.2 LID INSULATION INSTALLATION
The TI57 thermal insulation sheets are designed to be
used with both 23-inch and 29-inch EH5700 and
EH5700L Series enclosures. If insulation is required
for an 23-inch enclosure, the excess insulation must be
removed along the factory-marked perforation. For 29inch installations, no trimming is necessary. To install
the thermal insulation, perform the following steps:
3.1 BODY INSULATION INSTALLATION
1. Remove the necessary punch-out cable-feed pieces
from the insulation pad depending on the type of enclosure (EH5700 or EH5700L series) being used. Remove the vent area pieces for (-1, -2, -3) ventilation
through the enclosure. (See Figures 1 and 2.)
2. To adjust the length of the insulation pad, tear the
insulation along the perforations from the end of the
pad to fit either the 23-inch standard or Legacy® version of the enclosure.
3. Position the pad around the press nuts in the center
of the body by folding the pad along its length. Position the insulation punch-out(s) to closely match the
position of the press nuts.
1. Unlatch the enclosure lid and raise.
2. Pop the gas spring off of the lid at the ball-joint connection. Make sure the lid is supported and not allowed to lay completely open - doing so will damage the lid hinge.
3. Remove the punch-out pieces from the insulation pad
that accommodate the sun shroud screws and the lid
arm on the inside of the enclosure lid.
4. Adjust the necessary length of the pad according to
the length of the enclosure.
5. Remove the adhesive backing, and carefully lay the
insulation in the lid of the enclosure, pressing firmly,
taking care not to crease the insulation.
6. Position the insulation around the sun shroud fasteners on the inside of the lid. It may help to hold the
insulation in a folded manner while positioning.
7. Snap the gas spring ball joint to the lid, close the
enclosure.
29-inch
23-inch
23-inch
29-inch
Figure 1. Lid and Body Insulation Sheets
2 PELCO Manual C1433M (6/95)