Pelco TI57 User Manual

®
TI57 Thermal Insulation
for EH5700 Series Enclosures
Installation/Operation
Manual C1433M (6/95)
1.0 WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by PELCO.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
2.0 SCOPE
The information contained in this manual covers the TI57 Thermal Insulation Kit Installation.
2.1 DESCRIPTION
The TI57 Thermal Insulation Kit provides an improved resistance to heat loss through the body of the enclosure by adding a 1/4-inch thick polyurethane insulation to the majority of the internal surfaces.
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827
3.0 TI57 THERMAL INSULATION
NOTE: The camera mounting sled must be
removed for proper installation of the thermal insulation, therefore, it should be done prior to the enclosure installation. (- 1, -2, -3; heater/ blower/wiper kits must be removed prior to ther­mal insulation installation.)
4. Remove the adhesive backing, and carefully lay the insulation in the body of the enclosure, pressing firmly, taking care not to crease the insulation.
5. The insulation is very soft and will conform as needed during the installation of the camera and lens.
3.2 LID INSULATION INSTALLATION
The TI57 thermal insulation sheets are designed to be used with both 23-inch and 29-inch EH5700 and EH5700L Series enclosures. If insulation is required for an 23-inch enclosure, the excess insulation must be removed along the factory-marked perforation. For 29­inch installations, no trimming is necessary. To install the thermal insulation, perform the following steps:
3.1 BODY INSULATION INSTALLATION
1. Remove the necessary punch-out cable-feed pieces from the insulation pad depending on the type of en­closure (EH5700 or EH5700L series) being used. Re­move the vent area pieces for (-1, -2, -3) ventilation through the enclosure. (See Figures 1 and 2.)
2. To adjust the length of the insulation pad, tear the insulation along the perforations from the end of the pad to fit either the 23-inch standard or Legacy® ver­sion of the enclosure.
3. Position the pad around the press nuts in the center of the body by folding the pad along its length. Posi­tion the insulation punch-out(s) to closely match the position of the press nuts.
1. Unlatch the enclosure lid and raise.
2. Pop the gas spring off of the lid at the ball-joint con­nection. Make sure the lid is supported and not al­lowed to lay completely open - doing so will dam­age the lid hinge.
3. Remove the punch-out pieces from the insulation pad that accommodate the sun shroud screws and the lid arm on the inside of the enclosure lid.
4. Adjust the necessary length of the pad according to the length of the enclosure.
5. Remove the adhesive backing, and carefully lay the insulation in the lid of the enclosure, pressing firmly, taking care not to crease the insulation.
6. Position the insulation around the sun shroud fas­teners on the inside of the lid. It may help to hold the insulation in a folded manner while positioning.
7. Snap the gas spring ball joint to the lid, close the enclosure.
29-inch
23-inch
23-inch
29-inch
Figure 1. Lid and Body Insulation Sheets
2 PELCO Manual C1433M (6/95)
Loading...