2.2 Features ............................................................................................................................................. 2-14
2.3 Physical Description of the Camera .................................................................................................. 2-15
2.5 Sarix TI Web GUI ............................................................................................................................. 2-17
2.6 Technical Data and Specifications .................................................................................................... 2-18
2.6.1 System Specifications .............................................................................................................. 2-18
4.2 Camera Installation ............................................................................................................................. 4-2
4.2.1 Installation Guidelines and Preparation .................................................................................... 4-2
5.1 First Time Credentials Setup ............................................................................................................... 5-2
Page 5
Chapter 1: Important Notices Sarix TI Series Camera User Manual
5.2 Logging Into Sarix TI Camera Web GUI ........................................................................................... 5-3
5.3 Changing Your Password ................................................................................................................... 5-5
5.4 Main Window Overview .................................................................................................................... 5-6
5.5 Live View Window ............................................................................................................................ 5-7
5.6 Status Window .................................................................................................................................... 5-8
5.6.1 System Tab ................................................................................................................................ 5-9
5.11 System Window ................................................................................................................................ 5-51
8. Index ................................................................................................................................................. 8-65
Page 7
Chapter 1: Important Notices Sarix TI Series Camera User Manual
List of Figures
Figure 2-1: Sarix TI Camera General View .......................................................................................... 2-14
Figure 2-2: Physical Description of the Camera ................................................................................... 2-15
Figure 2-3: Sarix TI Label ..................................................................................................................... 2-16
Figure 2-4: Sarix TI Web GUI .............................................................................................................. 2-17
Figure 4-1: Sarix TI Camera Package General View .............................................................................. 4-1
Figure 4-2: Mechanical Interface Preparation - Camera Dimensions ..................................................... 4-3
Figure 4-3: Camera Installation - Wall Mount Configuration ................................................................ 4-4
Figure 4-4: Camera Installation - Pole Mount Configuration ................................................................. 4-5
Figure 4-5: Electrical ICD IP PoE Cable ................................................................................................ 4-6
Figure 5-1: Sarix TI Web GUI – First Time Setup ................................................................................. 5-2
Figure 5-2: Sarix TI Web GUI - Status Window (before Login) ............................................................ 5-3
Sarix TI Series Camera User Manual Chapter 1: Important Notices
1. Important Notices
1.1 Regulatory Notices [FCC Class A]
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
1.1.1 Radio and Television Interference
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can
void your authority to operate this equipment under Federal Communications Commission’s rules.
To maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation
with non-approved equipment or unshielded cables is likely to result in interference to radio and television
reception.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
1.2 Legal Notice [Audio Notice]
SOME PELCO EQUIPMENT CONTAINS, AND THE SOFTWARE ENABLES, AUDIO/VISUAL AND
RECORDING CAPABILITIES, THE IMPROPER USE OF WHICH MAY SUBJECT YOU TO CIVIL
AND CRIMINAL PENALTIES. APPLICABLE LAWS REGARDING THE USE OF SUCH
CAPABILITIES VARY BETWEEN JURISDICTIONS AND MAY REQUIRE, AMONG OTHER
THINGS, EXPRESS WRITTEN CONSENT FROM RECORDED SUBJECTS. YOU ARE SOLELY
RESPONSIBLE FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR STRICT
ADHERENCE TO ANY/ALL RIGHTS OF PRIVACY AND PERSONALTY. USE OF THIS
EQUIPMENT AND/OR SOFTWARE FOR ILLEGAL SURVEILLANCE OR MONITORING SHALL
BE DEEMED UNAUTHORIZED USE IN VIOLATION OF THE END USER SOFTWARE
Page 11
Chapter 1: Important Notices Sarix TI Series Camera User Manual
AGREEMENT AND RESULT IN THE IMMEDIATE TERMINATION OF YOUR LICENSE RIGHTS
THEREUNDER.
1.3 Video Quality Caution
1.3.1 Frame Rate Notice Regarding User Selected Options
Pelco systems are capable of providing high quality video for both live viewing and playback. However,
the systems can be used in lower quality modes, which can degrade picture quality, to allow for a slower
rate of data transfer and to reduce the amount of video data stored. The picture quality can be degraded by
either lowering the resolution, reducing the picture rate, or both. A picture degraded by having a reduced
resolution may result in an image that is less clear or even indiscernible. A picture degraded by reducing
the picture rate has fewer frames per second, which can result in images that appear to jump or move more
quickly than normal during playback. Lower frame rates may result in a key event not being recorded by
the system.
Judgment as to the suitability of the products for users' purposes is solely the users' responsibility. Users
shall determine the suitability of the products for their own intended application, picture rate and picture
quality. In the event users intend to use the video for evidentiary purposes in a judicial proceeding or
otherwise, users should consult with their attorney regarding any particular requirements for such use.
1.4 Open Source Software
This product includes certain open source or other software originated from third parties that is subject to
the GNU General Public License (GPL), GNU Library/Lesser General Public License (LGPL) and
different and/or additional copyright licenses, disclaimers, and notices.
The exact terms of GPL, LGPL, and some other licenses are provided to you with this product. Please refer
to the exact terms of the GPL and LGPL at http://www.fsf.org (Free Software Foundation) or
http://www.opensource.org (Open Source Initiative) regarding your rights under said license. You may
obtain a complete corresponding machine-readable copy of the source code of such software under the GPL
or LGPL by sending your request to digitalsupport@pelco.com; the subject line should read Source Code
Request. You will then receive an email with a link for you to download the source code.
This offer is valid for a period of three (3) years from the date of the distribution of this product by Pelco.
1.5 CCC Power Cord Statement
Models shipped to China do not include power cords.
1-9
Page 12
A CCC approved power cord must be used to power the equipment
WARNING: This product is sensitive to Electrostatic Discharge (ESD). To avoid ESD
Electrostatic Discharge Association (www.esda.org).
when used in China
1.5.1 2.4 GHZ Radio Device
1.6 ESD Warning
damage to this product, use ESD safe practices during installation. Before touching,
adjusting or handling this product, correctly attach an ESD wrist strap to your wrist and
appropriately discharge your body and tools. For more information about ESD control and
safe handling practices of electronics, please refer to ANSI/ESD S20.20-1999 or contact the
Sarix TI Series Camera User Manual Chapter 1: Important Notices
NOTE
1.7 Warranty
For information about Pleco's product warranty and thereto related information, refer to
www.pelco.com/warranty.
1.8 Network Topology Statement
IMPORTANT NOTE. PLEASE READ. The network implementation is shown as a general
representation only and is not intended to show a detailed network topology. Your actual network will
differ, requiring changes or perhaps additional network equipment to accommodate the system as
illustrated. Please contact your local Pelco representative to discuss your specific requirements.
Page 13
Chapter 1: Important Notices Sarix TI Series Camera User Manual
List of Acronyms and Abbreviations
AWG: American Wire Gauge NUC: Non-Uniformity Correction
CBR:Constant Bit RateNV: Night Vision
Histogram:
CE: Comminute European
CMOS:
DC: Direct Current QVGA+: Quarter Video Graphics Array (384 ×288)
DFPA:
DHCP:
Dynamic Host Configuration Protocol ROI: Region Of Interest
DNS:
Federal Communications Commission
FCC:
I-frame: Infra-coded frame RTSP:
FM:
FOV: Field Of View
FPS:
Ground SSL: Secure Sockets Layer
GND:
Accurate representation of the
distribution of numerical data.
ONVIF:Open Network Video Interface Forum
P/N:Part Number
Complementary Metal-Oxide
Semiconductor
Digital Focal Plan Array RH: Relative Humidity
Domain Name System RTN: Return
Power Over Ethernet
PoE:
RTP:
Real Time Protocol
Real-Time Streaming Protocol
Firmware
Frames Per Second VMS: Video Management System
S/N:
SDK:
Serial Number
Software Development Kit
GOP:Group of PicturesSW:Software
Graphical User InterfaceTCP:Transmission Control Protocol
GUI:
HD:
HTTP: Hypertexts Transfer Protocol TLS:
HTTPS: HyperText Transfer Protocol Secure URI:
IEEE:
IP: Internet Protocol
IR: Infrared VDC:
JPEG: Joint Photographic Expert Group
LAN: Local Area Network VGA:
MAC:
mK:
milli-Kelvin WWW:World Wide Web
NETD: Noise Equivalent Temperature
High Definition
Institute of Electrical and Electronics
Engineers
Media Access Control
Difference
TINT:
Transport Layer Security
V bus
VBR: Variable Bit Rate
Volts, Direct Current
VDDA:
Video Graphics Array (640 × 480)
VGSK:
Pipeline: data processing elements, connected in
Time Integration
Uniform Resource Indicator
CTIA reference voltage
Analog supply fixed
Compensation microbolometer - transistor
gate voltage
series, where the output of one element
is the input of the next one.
1-11
Page 14
Scope of This Manual
This manual provides the necessary information for introducing, installing, operating and
maintaining the Sarix TI Series Camera.
The manual in intended for use by technicians and operators and consists of the following
chapters:
Chapter2: Overview:
Introduces the Sarix TI Series Camera and its web GUI features.
Chapter 3: Safety:
Provides safety instructions that technicians should be aware of during the installation,
operation and maintenance of the Sarix TI Series Camera.
Chapter 4: Installation:
Provides instructions for installing the Sarix TI Series Camera.
Chapter 5: Operation:
Provides operating instructions for the Sarix TI Series Camera web GUI.
Chapter 6: Maintenance:
Provides the Sarix TI Series Camera preventive maintenance instructions.
Chapter 7: Ordering Information:
Provides information for purchasing the Sarix TI Series Camera and accessories.
Index:
Provides a list, arranged in alphabetical order, of keywords found throughout this manual.
Sarix TI Series Camera User Manual Chapter 1: Important Notices
Page 15
Chapter 2: Overview Sarix TI Series Camera User Manual
2. Overview
This chapter introduces the Sarix TI Series Camera and its web GUI features.
The chapter consists of the following sections:
Section 2.1: Overview
Section 2.2: Features
Section 2.3: Physical Description of the Camera
Section 2.5: Sarix TI Web GUI
Section 2.6: Technical Data and Specifications
2-13
Page 16
2.1 Overview
Sarix TI Camera is a state of the art observation system, boasting an incredibly easy installation
with thermal and visual capabilities. The Sarix TI line of cameras is a broad portfolio of high
performance outdoor rated cameras for 24/7 perimeter surveillance, observation, and monitoring
of critical infrastructure and sensitive sites.
Equipped with thermal and visible-light channels, the Sarix TI meets global Open Network
Video Interface Forum (ONVIF) standards to ensure interoperability of hardware and software
products for easy integration to both existing and new infrastructures, regardless of
manufacturer.
The Sarix TI is ruggedly designed to withstand the harshest weather and environmental
conditions, including rain, direct sunlight, high humidity, dust, heat, and cold.
The Sarix TI uses new and innovative open uncooled 17μ 640 x 480 or 384 x 288 resolution
thermal core and video enhancement algorithm.
Sarix TI Series Camera User Manual Chapter 2: Overview
Figure 2-1: Sarix TI Camera General View
2.2 Features
Both visible and Video Graphics Array (VGA) thermal channels
ONVIF Profile S compliant
Easy installation
Advanced optics
Low cost of ownership
Best support for analytics
Rugged design
Enhanced image processing
Page 17
Chapter 2: Overview Sarix TI Series Camera User Manual
1
5
2
3 (x4)
4
Bottom View
2.3 Physical Description of the Camera
The Sarix TI Camera outer components include (see Figure 2-2):
1. Infrared (IR) Camera Lens
2. Main Connector (Power and Ethernet)
3. Camera-to-Pole Mount Adapter fastening screws (x4)
4. Tripod mount fastening screw
5. Complementary Metal-Oxide Semiconductor (CMOS) Camera Lens (module depended).
Figure 2-2: Physical Description of the Camera
2-15
Page 18
2.4 Marking
The camera us marked with a label as shown below:
Sarix TI Series Camera User Manual Chapter 2: Overview
Figure 2-3: Sarix TI Label
NOTE: For reference only
Page 19
Chapter 2: Overview Sarix TI Series Camera User Manual
2.5 Sarix TI Web GUI
The operation of the Sarix TI Camera is performed via Web Graphical User Interface (GUI).
With the GUI you can:
Setup the camera operation.
Optimize the camera video.
Communicate with Video Management Systems (VMS).
Figure 2-4: Sarix TI Web GUI
2-17
Page 20
2.6 Technical Data and Specifications
2.6.1 System Specifications
Applicable to models :Sarix TI 14.2mm, 35mm, and 50mm.
Table 2-1: Technical Data and Specifications - System Specifications
Thermal Camera: Imager Type: Uncooled ASi Microbolometer
Spectral Band: 7.5 - 14µ
Pixel Size: 17µ
Resolution: 640 x 480 (VGA) or 384 x 288 (QVGA)
NETD: VGA: < 40° mk, QVGA+: < 70° mk
Day Camera: Imager Type: ¼" CMOS
Resolutions: 640 x 480, 1024 x 768, or 1280 x 768
Field of View: 54° (H) x 42° (V) @ 1024 x 768
Sarix TI Series Camera User Manual Chapter 2: Overview
Environmental: Storage Temp: -40°C to +71°C (-40° F to +160° F)
Mechanical
Parameters:
Power Input: 12 - 32VDC or Power over Ethernet (IEEE
802.3af/802.3at)
Consumption: 7W typical, 20W max. (based on DC voltage)
Operating Temp: -40°C to +55°C (-40° F to +131° F)
Humidity: +40°C, 95% RH
Rating: IP66 (NEMA 4X equivalent)
Dimensions: - 135mm (w), 202mm (d), 169mm (h)
- 5.32" (w), 7.95" (d), 6.65" (h)
System
Integration:
Weight: - 14 and 35mm: 2.2kg,
- 50mm: 2.4kg,
Interfaces: ONVIF Profile S, Web GUI
Page 21
Chapter 2: Overview Sarix TI Series Camera User Manual
EN 55032:12;
Network: Default IP: 192.168.0.20
RTSP Port: 8554
Protocols: IPv4, HTTP, HTTPS, SSL/TLS, RTSP, DHCP
Certifications: - CE
- FCC
- IP66
- UL and cUL
2.6.2 Configurations
EN 55024:2010+A1:2015;
EN 50130-4:11+A1:14;
EN 61000-3-2:14;
EN 61000-3-3:13;
EN 60950-1:06+A11:09+A1:10+A12:11+A2:13
UL 60950-1 2nd edition;
CAN/CSA-C22.2 No. 60950-1:07+Amend 1:2011
IEC 60950-1:05+A1:09+A2:13;
IEC 60950-22:16
Table 2-2: Technical Data and Specifications - Configurations
Day/Night Day
Configuration Type Thermal Camera & Lens Camera & Lens
VGA 17μ 640 x 480 Athermalized
Uncooled Thermal
QVGA+ 17μ 384 x 288 Athermalized
Uncooled Thermal
¼" Colour HD CMOS 1280 x 720
Autofocus
2-19
Page 22
2.6.3 Thermal Camera
Table 2-3: Technical Data and Specifications - Thermal Camera
Configuration TI2X14 TI2X35 TI2X50
Thermal Type Uncooled
Thermal Core 17µ 640 x 480 (VGA) or
Lens Type Athermalized, Fixed Focus
Focal Length 14.2mm 35mm 50mm
Lens F # f/1.2 f/1.2 f/1.2
Horizontal FOV - VGA 42.1° 17.6° 12.4°
Horizontal FOV - QVGA+ 25.7° 10.6° 7.5°
Video Type H.264, Motion JPEG (25Hz
Sarix TI Series Camera User Manual Chapter 2: Overview
17µ 384 x 288 (QVGA+)
or 9Hz)
Spectral Band Spectral Band 7.5 - 14µ
NETD < 40° mk (VGA), < 70° mk
(QVGA+)
Digital Zoom 1x, 2x, 4x
Control Operation Polarity, NUC, Image Flip,
Image Rotation & Digital
Zoom
2.6.4 CMOS Camera
Table 2-4: Technical Data and Specifications - CMOS Camera
Imager Type: 1/4" Colour HD CMOS
Effective Pixels / Resolutions: 640 x 480 or 1024 x 768 or 1280 x 720
Lens Type: Autofocus
Imager FOV (H x V): 54° x 42°
S/N Ratio: 36dB
Additional Features: Configurable Resolutions, Digital Zoom
Page 23
Chapter 3: Safety Sarix TI Series Camera User Manual
3. Safety
This chapter provides safety instructions that technicians should be aware of during the
installation, operation and maintenance of the Sarix TI Series Camera.
The chapter consists of the following sections:
Section 3.1: Safety Conventions
Section 3.2: Safety During Installation
Section 3.3: Safety During Maintenance
3.1 Safety Conventions
In this manual, safety information is presented as warnings, cautions, and notes.
WARNING
An operating procedure, practice, and so forth, which if not correctly
followed, could result in personal injury or loss of life.
CAUTION
An operating procedure, practice, and so forth, which if not strictly
observed, could result in damage to, or destruction of equipment.
NOTE
An operating procedure, practice, and so forth that is essential
to highlight.
All procedures in this manual must be performed in accordance with
the applicable local regulations.
All local safety regulations apply. If the instructions in any section of
this manual contradict those of the applicable local regulations, the
instructions of the applicable local regulations will prevail.
3-1
Page 24
3.2 Safety During Installation
To avoid injuries, follow standard safety regulations if mounting the Sarix TI Camera on an
elevated location.
3.3 Safety During Maintenance
Warranty void if opening the Sarix TI camera.
Do not touch the Sarix TI Camera optics with bare hands.
Do not use any chemicals for cleaning the Sarix TI Camera. Use only wipes approved for
optical equipment. Failure to comply could result in damage to the Sarix TI Camera opticallens and/or its surfaces.
Sarix TI Series Camera User Manual Chapter 3: Safety
3-2
Page 25
Chapter 4: Installation Sarix TI Series Camera User Manual
4. Installation
This chapter provides instructions for installing the Sarix TI Series Camera.
The chapter consists of the following sections:
Section4.1: Unpacking
Section4.2: Camera Installation
4.1 Unpacking
A standard package contains the following:
Sarix TI Camera
18-pin round female cable-connector
Ferrite
Washer Lock
Screw 6-32NCX1/4" SOC HD SS
Terminal lug ring 16AWG stub size 6
Package
Figure 4-1: Sarix TI Camera Package General View
4-1
Page 26
4.2 Camera Installation
NOTE
Opening the Sarix TI Camera enclosure will void the product
warranty.
CAUTION
Avoid pointing the Sarix TI Camera at the sun.
4.2.1 Installation Guidelines and Preparation
Prepare your self-made IP PoE cable (cables are available for purchase, see
Table 7-3 for information).
4.2.1.1Cable wires between camera and DC/PoE power supply should be 20-22AWG.
Sarix TI Series Camera User Manual Chapter 4: Installation
4.2.1.2Both the camera ant the end-equipment connected to it should be permanently
connected to protective earth, using screw and washers. Wires should be made
of cupper. Minimal grounding cable is 14AWG.
4.2.1.3In case of using DC power supply:
(1) The cables should be protected by fuse with maximal current of 3A
(2) The output current shall not exceed 3A after 60s
(3) The maximal output current of the power supply shall not exceed 7.5A
4.2.1.4Power supply (either POE injector or DC power supply) should be safety
approved for local regulations.
4.2.1.5Install the Ferrite on the operational cable as close as possible , max 5cm, from
the system.
4-2
Page 27
Chapter 4: Installation Sarix TI Series Camera User Manual
4.2.2 Mechanical Interface Preparation
NOTE
It is recommended to check the functioning of the Sarix TI Camera
prior to the actual installation.
Figure 4-2 depicts the camera dimensions and mechanical interfaces.
Figure 4-2: Mechanical Interface Preparation - Camera Dimensions
4-3
Page 28
4.2.3 Wall Mount Configuration
An arm for wall-mount is available for purchase (see Table 7-3 for information).
The dimensions of the arm are given in Figure 4-3:
Figure 4-3: Camera Installation - Wall Mount Configuration
Sarix TI Series Camera User Manual Chapter 4: Installation
4-4
Page 29
Chapter 4: Installation Sarix TI Series Camera User Manual
4.2.4 Pole Mount Configuration
An adapter for pole-mount is available for purchase (see Table 7-3 for information).
The dimensions of the device are given in Figure 4-4 (note that the arm for wall-mount is
required, as well):
Figure 4-4: Camera Installation - Pole Mount Configuration
4-5
Page 30
4.2.5 Electrical ICD IP PoE Cable
Connector Pin #
Connector Pin #
Signal Name
Ethernet\POE
2 1 ETH RX+
6 2 ETH RX-
11 3 ETH TX+
15 6 ETH TX-
12
5,4
POE +
14
7,8
POE -
DC Power Input
8
P.S (-)
12-32vDC RTN
9
P.S (+)
12-32vDC
Shield
Camera body
GND Stud
Shield
The cable is available for purchase (see Table 7-3 for information).
Cable Pinout (see Figure 4-5):
Table 4-1: Electrical ICD IP PoE Cable - Pinout
Sarix TI Series Camera User Manual Chapter 4: Installation
P1
P2 (RJ45)
Figure 4-5: Electrical ICD IP PoE Cable
4-6
Page 31
Chapter 5: Operation Sarix TI Series Camera User Manual
5. Operation
This chapter provides operating instructions for the Sarix TI Series Camera web GUI.
The chapter consists of the following sections:
Section 5.1: First Time Credentials Setup
Section 5.2: Logging Into Sarix TI Camera Web GUI
Section 5.3: Changing Your Password
Section 5.4: Main Window Overview
Section 5.5: Live View Window
Section 5.6: Status Window
Section 5.7: Network Window
Section 5.8: Streaming Window
Section 5.9: Image Processing Window
Section 5.10: Analytics Window
Section 5.11: System Window
Section 5.12: Logging Out from the Web GUI
5-1
Page 32
5.1 First Time Credentials Setup
1. Open your web browser.
2. Type the Sarix TI Camera default IP address (192.168.0.20) in the address bar and click
Enter. The First Time Setup window opens (example):
Figure 5-1: Sarix TI Web GUI – First Time Setup
Sarix TI Series Camera User Manual Chapter 5: Operation
NOTE
The First Time Setup window appears the first time a user accesses
the camera’s IP address.
3. Define the administrator username in the Admin Login section.
4. Define the administrator password in the Admin Password section.
5. Retype the same password in the Admin Password (confirm) section.
6. Click ADD. The administrator credentials are defined.
NOTE
After defining the administrator credentials, the Status window
opens (see Section 5.2).
5-2
Page 33
Chapter 5: Operation Sarix TI Series Camera User Manual
5.2 Logging Into Sarix TI Camera Web GUI
1. Open your web browser.
2. Type the Sarix TI Camera default IP address (192.168.0.20) in the address bar and click
Enter. The Status window opens (example):
Figure 5-2: Sarix TI Web GUI - Status Window (before Login)
3. You may now view some default settings of your Sarix TI Camera by expanding the
System, Thermal or Day tabs.
4. Click . The Login window opens:
Figure 5-3: Login Window
NOTE
A user is able to login only after they set up their credentials for the
first time (see Section 5.1).
5-3
Page 34
Sarix TI Series Camera User Manual Chapter 5: Operation
5. Enter your Username and Password:
Figure 5-4: Login Window – Entering Username and Password
6. Click . The following message is displayed on the lower-left corner of the screen
for three seconds, stating that you have successfully logged in. In addition, the Status
window opens:
Figure 5-5: Sarix TI Web GUI - Status Window (after Login)
You can now use the Sarix TI Web GUI.
5-4
Page 35
Chapter 5: Operation Sarix TI Series Camera User Manual
5.3 Changing Your Password
1. From the upper-right drop-down menu select Change Password:
Figure 5-6: Changing Your Password - Drop Down Menu
The following opens:
Figure 5-7: Sarix TI Web GUI - Changing Your Password
5-5
2. Enter your Current Password.
3. Enter the New Password and re-enter in the New Password (Confirm) field.
4. Click . The system automatically logs out and the Login window reopen
(see Figure 5-3).
5. Log in using the new password. The Status window re-opens (see Figure 5-5).
Page 36
5.4 Main Window Overview
The main areas in every window consist of the following:
Figure 5-8: Main Window Overview - Main Areas
Sarix TI Series Camera User Manual Chapter 5: Operation
Legend
:
1. Menu: maneuvering between the GUI main features/tabs.
2. The name of the currently opened feature/tab.
3. Available only after logging in; a drop-down menu, enables to change your password or log
out from the program.
4. The area where you can view and/or set the feature parameters.
5-6
Page 37
Chapter 5: Operation Sarix TI Series Camera User Manual
5.5 Live View Window
The Live View window allows viewing the Sarix TI Camera live video.
1. Click Live View. The Live View window opens, containing a live video display of both
thermal and visual cameras (example):
Figure 5-9: Live View Window (example)
2. To freeze the live-view video click . Click to resume the live-view video.
3. To view the video in full screen click . Click the keyboard Esc key to resume.
4. To take a snapshot of the video and save elsewhere:
a. Click . A *.jpg file is created and downloaded into your PC. The file is saved in
your \Downloads folder.
- the file name of the thermal camera snapshot: proxycam-ir-Snapshot.
- the file name of the visual camera snapshot: proxycam-vis-Snapshot.
b. You can now move the file elsewhere.
5-7
Page 38
5.6 Status Window
The Status window allows viewing some of the Sarix TI Camera parameters and settings.
1. Click Status. The Status window opens (all collapsed):
Sarix TI Series Camera User Manual Chapter 5: Operation
Figure 5-10: Status Window (all collapsed)
The Status window is comprised of three tabs:
System Tab: allows viewing general parameters related to the camera settings and its
software/firmware (see Section 5.6.1).
Thermal Tab: allows viewing parameters related to the thermal camera settings and its
software/firmware (see Section 5.6.2).
Day Tab: allows viewing parameters related to the visual camera settings and its
software/firmware (see Section 5.6.3).
Disabling / Enabling a Camera:allows disabling the thermal camera and/or the visual
camera and enable them (see Section 5.6.4).
5-8
Page 39
Chapter 5: Operation Sarix TI Series Camera User Manual
5.6.1 System Tab
The System tab allows viewing general parameters related to the camera settings and its
software/firmware.
Expand the System tab. The following opens:
Figure 5-11: Status Window - System Tab
The System tab consists of the following parameters:
System temperature: the "System On Chip" temperature.
System up time: the operating time since the last camera startup.
System load: a coded indication on how the system is busy.
ONVIF service URI: the Uniform Resource Indicator (URI), e.g., the ONVIF device web
service address.
IP address: the camera IP address.
Product: the camera name.
Serial number: the system Serial Number (S/N).
Firmware version: the version of the installed Firmware (FM).
Build date: the date of the FM creation.
MAC address: the camera unique Media Access Control (MAC) address.
5-9
Page 40
5.6.2 Thermal Tab
The Thermal tab allows viewing parameters related to the thermal camera settings and its
software/firmware.
Expand the Thermal tab. The following opens:
Sarix TI Series Camera User Manual Chapter 5: Operation
Figure 5-12: Status Window - Thermal Tab
5-10
Page 41
Chapter 5: Operation Sarix TI Series Camera User Manual
The Thermal tab consists of the following parameters:
Pipeline ID: the current name of the pipeline (data processing elements, connected in series,
where the output of one element is the input of the next one).
Pipeline Running: is the pipeline running?
Pending Updates: does the pipeline requires initialization?
Actual FPS: the current frame-rate where the pipeline is running.
DFPA: indication from the thermal camera.
Firmware version: indication from the thermal camera.
Gain: indication from the thermal camera.
Frame rate [Hz]: indication from the thermal camera.
Serial number: indication from the thermal camera.
Software version: indication from the thermal camera.
TINT: indication from the thermal camera.
Sensor temp [°C]: indication from the thermal camera.
V bus: indication from the thermal camera.
VDDA: indication from the thermal camera.
VGFID: indication from the thermal camera.
VGSK: indication from the thermal camera.
VT bias: indication from the thermal camera.
VTOFS1: indication from the thermal camera.
VTOFS2: indication from the thermal camera.
5-11
Page 42
5.6.3 Day Tab
The Day tab allows viewing parameters related to the thermal camera settings and its
software/firmware.
Expand the Day tab. The following opens:
Sarix TI Series Camera User Manual Chapter 5: Operation
Figure 5-13: Status Window - Day Tab
The Day tab consists of the following parameters:
Pipeline ID: the current name of the pipeline.
Pipeline Running: is the pipeline running?
Pending Updates: does the pipeline requires initialization?
Actual FPS: the current frame-rate where the pipeline is running.
5-12
Page 43
Chapter 5: Operation Sarix TI Series Camera User Manual
5.6.4 Disabling / Enabling a Camera
This option allows to disable the thermal camera and/or the CMOS camera and re-enable them.
5.6.4.1 Disabling the Camera
1. Expand the Thermal / Day tab and click . The following opens:
2. Click OK to approve. The following opens while the system re-boots:
Figure 5-14: Disabling / Enabling a Camera - System Reboot
5-13
Page 44
Sarix TI Series Camera User Manual Chapter 5: Operation
On completion, the following opens stating that the corresponding camera is disabled:
Figure 5-15: Disabling / Enabling a Camera - System Reboot Approval
The camera view does not appear anymore on the Live View window.
5.6.4.2 Enabling the Camera
1. Expand the Thermal / Day tab and click . The following opens:
2. Click OK to approve. The system re-boots (see Figure 5-14).
On completion, a message is displayed stating that the system has restarted
(see Figure 5-15).
The camera view is now available on the Live View window.
5-14
Page 45
Chapter 5: Operation Sarix TI Series Camera User Manual
5.7 Network Window
The Network window allows configuring the HOST-to-Camera Ethernet communication
method.
The secondary stream option consists of the following parameters:
VBR quality factor: 1 is the lowest level.
GOP I-frame spacing: Group Of Pictures; how many frames will include an Intra-Frame.
Video encoding: selection of the video coding (mjpeg requires a system restart).
5-24
Page 55
Chapter 5: Operation Sarix TI Series Camera User Manual
5.8.2 Day Tab
Under each option in the Day Tab you can:
• Click to restart the video streaming.
• Click to stop the video streaming.
• Click to re-start the video streaming.
5.8.2.1 Main Stream
Expand the Main Stream option. The following opens (click for the changes to take
effect; click to revert your changes):
Figure 5-27: Streaming Window - Day Tab - Main Stream
5-25
The main stream option consists of the following parameters:
• CBR: the video flow-rate (Kb/Sec).
• IntraQp: an auto calculation of the I-level quality-level (default: -1).
• VBR quality factor: 1 is the lowest level (applies only for VBR).
• Rate Control: CBR or VBR.
• GOP: Group Of Pictures; how many frames will include an Intra-Frame.
Page 56
Sarix TI Series Camera User Manual Chapter 5: Operation
• Unit Type: selection of the installed camera/lens type and the installation method.
• Video Scale: the video resolution; "NO CHANGE": 1280 x 720 (HD).
• Video Encoding: selection of the video coding (mjpeg requires a system restart).
• Image Size/Rate: selection of the video that will be taken from the camera.
5-26
Page 57
Chapter 5: Operation Sarix TI Series Camera User Manual
5.8.2.2 Secondary Stream
Expand the Secondary Stream option. The following opens (click for the changes to
take effect; click to revert your changes):
Figure 5-28: Streaming Window - Day Tab - Secondary Stream
The secondary stream option consists of the following parameters:
VBR quality factor: 1 is the lowest level.
GOP I-frame spacing: Group Of Pictures; how many frames will include an Intra-Frame.
Video encoding: selection of the video coding (mjpeg requires a system restart).
5-27
Page 58
5.8.3 General Configuration Tab
Select the General Configuration tab. The following opens (click for the changes to
take effect; click to revert your changes):
Figure 5-29: Streaming Window - General Configuration Tab
Sarix TI Series Camera User Manual Chapter 5: Operation
The General Configuration tab consists of the following parameters:
Enable Authentication: user/password enabled.
RTSP Port: the RTSP port.
RTSP Over HTTP Enabled
RTSP Over HTTP Port
5-28
Page 59
Chapter 5: Operation Sarix TI Series Camera User Manual
EYE-Q™
5.9 Image Processing Window
The Image Processing window allows changing the video display method, orientation and
quality.
Click Image Processing. The Image Processing - Thermal tab opens.
5.9.1 Thermal Tab
1. You can:
•From the Active Pipeline drop-down list select the pipeline name that is currently
2. Set the Noise filter level: filtering noises. It is recommended to remain with
the default value (high-value filtering will result in movement smudge).
5-31
Page 62
Sarix TI Series Camera User Manual Chapter 5: Operation
5.9.1.3 Gain Control Settings
Expand the Gain Control option. The following opens (click for the changes to take
effect; click to revert your changes):
Figure 5-33: Image Processing Window - Thermal Tab - Gain Control Settings
The Gain Control option consists of the following parameters:
Bad picture pacifier: noise-level deductions. It is recommended to remain with the default
value.
Gray Levels: the quantity of the gray-levels (up to 200).
5-32
Page 63
Chapter 5: Operation Sarix TI Series Camera User Manual
5.9.1.4 Advanced Settings
Expand the Advanced Settings option. The following opens (click for the changes to
take effect; click to revert your changes):
Chapter 5: Operation Sarix TI Series Camera User Manual
5.10 Analytics Window
The Analytics Window enables detecting and tracking movement within predefined ROIs, as
well as for teaching the system where movement typically occurs.
1. Click Analytics. The Analytics window opens (all collapsed):
Figure 5-42: Analytics Window (all collapsed)
The Analytics window is comprised of three tabs:
Regions Tab: enables marking of regios to detect movement (see Section 5.10.1).
Ignore Regions Tab: enables marking of regions in which movement is ignored (see Section
5.10.2).
Learning Tab: enables the system to learn the viewed scene and where movement typically
occurs (see Section 5.10.3).
NOTE
When entering the Analytics window, either of the following
messages is displayed on the lower-left corner of the screen,
depending on whether VMD is active or disabled. Click OK to close
these messages.
5-41
Page 72
To enable/disable viewing analytics, click in the top-left
corner of the screen to toggle between enable and disable. Click
changes).
5.10.1 Regions Tab
The Regions tab enables marking regions to detect movement.
1. Expand the Regions tab. The following opens:
Sarix TI Series Camera User Manual Chapter 5: Operation
NOTE
for the changes to take effect (click to revert your
Figure 5-43: Analytics Window - Regions Tab
5-42
Page 73
Chapter 5: Operation Sarix TI Series Camera User Manual
2. Click the + sign. The following opens (example):
Figure 5-44: Analytics Window - Regions Tab - Region Options
3. Click in the Name field and enter a region name.
4. Select region type from the following options:
Area – detection is done within a close frame.
Fence – detection is done for objects moving towards a predefined line.
NOTE
Some region options change depending on the type of region
selected.
5-43
Page 74
Sarix TI Series Camera User Manual Chapter 5: Operation
5. Select the following parameters:
•Minimum Detection Size: determines the size and characters of the object to be
detected.
• ONVIF Alert: enabling receiving alerts which conform to ONVIF protocol.
• Maximum Speed: fastest speed that will be detected, in m/sec (default: 1 m/sec)
• Area Direction: determines the type of object movement (in relation to the region) that
will be detected (this option is available when Area type region is selected)
•Fence direction: determines the type of object movement (in relation to the fence line)
that will be detected (this option is available when Fence type region is selected)
5-44
Page 75
Chapter 5: Operation Sarix TI Series Camera User Manual
6. Click the live image to mark the region frame points.
7. Double click the region starting point to end the region marking.
Figure 5-45: Analytics Window - Regions Tab - Area ROI
Figure 5-46: Analytics Window - Regions Tab - Fence ROI
5-45
NOTE
The color next to the region name corresponds with the color of the
region marked on the image.
Page 76
8. To delete a region definition: select the region (Region-1 or Region-2 in the
example) and click the - sign.
9. Click for the changes to take effect (click to revert your
changes).
5.10.2 Ignore Regions Tab
The Ignore Regions tab enables marking regions in which movement is ignored.
Expand the IgnoreRegions tab. The following opens:
Figure 5-47: Analytics Window - Ignore Regions Tab
Sarix TI Series Camera User Manual Chapter 5: Operation
5-46
Page 77
Chapter 5: Operation Sarix TI Series Camera User Manual
1. Click the + sign. The following opens (example):
Figure 5-48: Analytics Window - Ignore Regions Tab – Ignore Regions ROI (1 of 2)
2. Click the live image to mark the Ignore Region frame points.
3. Double click the region starting point to end the Ignore Region marking.
Figure 5-49: Analytics Window - Ignore Regions Tab – Ignore Regions ROI (2 of 2)
5-47
Page 78
4. To delete an Ignore Region definition: select the ignore region
(IgnoreRegion-1 or IgnoreRegion-2 in the example) and click the - sign.
5. Click for the changes to take effect (click to revert your
changes).
5.10.3 Learning Tab
The Learning tab enables the system to learn the scene and where movement typically occurs.
Expand the Learning tab. The following opens:
Sarix TI Series Camera User Manual Chapter 5: Operation
Figure 5-50: Analytics Window - Learning Tab
1. Click either of the following buttons:
• Click to start the learning session.
• Click to resume the learning session after the Stop button was activated.
• Click to stop the learning session (if, for example, unusual activity is
occurring).
•Click to delete the learning session in progress.
NOTE
VMD must be active (i.e., the toggle button in the top-left corner of
the screen must appear like this: ) to start the learning
session.
5-48
Page 79
Chapter 5: Operation Sarix TI Series Camera User Manual
NOTE
When the Start button is pressed, the following message is displayed
on the lower-left corner of the screen. Click OK to close this
message.
5.10.4 Analytics Settings
Click in the upper-right corner of the screen. The following opens:
Sarix TI Series Camera User Manual Chapter 5: Operation
The Analytics Settings window consists of the following parameters:
ActiveBlockPercent: Percentage of the block area that should be active in order to detect
movement (default: 70%)
BlockSize: minimum block size (default: 8)
Draw Region: enabling drawing of region
Draw Target Box: enabling frame overlay around the moving target
Draw Target Trail: enabling trail showing the path the moving target has taken. The
maximum trail length is determined by “MaxTargetTrailLength”
Initial Noise Level: higher level reduces the effect of noise in a scene, but also reduces
detection sensitivity (default: 6)
LearningTime: length of time, in seconds, the learning session will run (default: 30 seconds)
MaxTargetTrailLength: trail length, in FPS (default: 120 FPS). Will not display if “Draw
Target Trail” is not enabled
Scene History: minimum number of frames that are used for movement detection (default:
2)
TTL: length of time, in seconds, a target will continue to be considered a target after it
hasn’t been seen (default: 2 seconds)
Track All Frame: enabling tracking of target in entire image frame, not just in the ROI the
object was detected in
Warning Time: elapsed time, in seconds, until the system defines the identified object as a
target (default: 0.4 seconds)
NOTE
To close the Analytics Settings screen, click in the upper-right
corner of the screen. Any changes that were made are retained.
5-50
Page 81
Chapter 5: Operation Sarix TI Series Camera User Manual
5.11 System Window
The System Window consists of five tabs:
Admin Tab (see Section 5.11.1)
Logs Tab (see Section 5.11.2)
Date and Time Tab (see Section 5.11.3)
File Upload Tab (see Section 5.11.4)
User Management Tab (see Section 5.11.5)
5.11.1 Admin Tab
Click ADMIN. The following opens:
Figure 5-52: System Window - Admin Tab
5.11.1.1 Restart
To completely restart the entire system:
1. Click . The following opens:
Figure 5-53: System Window - Admin Tab - Restart Aproval
5-51
Page 82
Sarix TI Series Camera User Manual Chapter 5: Operation
2. Click OK to approve the system restart. The following opens, stating that the
restart process could take a few minutes:
Figure 5-54: System Window - Admin Tab - Restart
On completion, the following opens prompting that the restart is completed:
5.11.1.2 Archive System Files
To archive the entire system files:
1. Click . The following opens, prompting that the archiving is in process:
Figure 5-55: System Window - Admin Tab - Archive System Files
5-52
Page 83
Chapter 5: Operation Sarix TI Series Camera User Manual
On completion, the following opens prompting to approve the download of the archived file:
2. Click Yes to download the file. The file is downloaded and saved in your
\Downloads folder. File name: System-files.tgzx.
5.11.1.3 Save As Site
To save the current settings of the camera and the GUI as site defaults:
1. Click . The following opens:
Figure 5-56: System Window - Admin Tab - Save As Site Approval
2. Click OK to proceed. The following opens, prompting that site defaults save
is in process:
Figure 5-57: System Window - Admin Tab - Save As Site
5-53
Page 84
Sarix TI Series Camera User Manual Chapter 5: Operation
On completion, the following opens prompting that the site defaults are saved:
5.11.1.4 Export Site
To download an archived file that contain the site defaults:
1. Click . The following opens prompting to approve the site defaults download:
Figure 5-58: System Window - Admin Tab - Export Site Approval
2. Click Yes to download the file with DHCP, OR:
Click No to download the file with a constant IP address.
The file is downloaded and saved in your \Downloads folder. File name:
site-defaults.tgzx.
5.11.1.5 Site Defaults
To revert system settings back to the site defaults settings:
1. Click . The following opens prompting to approve the revert process:
Figure 5-59: System Window - Admin Tab - Site Defaults Approval
5-54
Page 85
Chapter 5: Operation Sarix TI Series Camera User Manual
2. Click OK. The following opens, prompting that the site defaults restoration
is in process:
Figure 5-60: System Window - Admin Tab - Site Defaults
On completion, the following opens prompting that the site defaults are saved:
5.11.1.6 Factory Defaults
To revert settings to factory defaults:
1. Click . The following opens prompting to approve the revert process:
If Preserve IP is unchecked, the system will restart with the default
IP.
5-55
If Preserve Users is unchecked, all users will be deleted upon
system restart.
Page 86
Sarix TI Series Camera User Manual Chapter 5: Operation
2. Click OK. The following opens, prompting that the factory defaults restoration is in process:
Figure 5-62: System Window - Admin Tab - Factory Defaults
On completion, the following opens prompting that the factory defaults are saved:
5-56
Page 87
Chapter 5: Operation Sarix TI Series Camera User Manual
5.11.2 Logs Tab
The Status tab allows downloading data files from the Sarix TI Camera. This is mainly useful
when troubleshooting possible Sarix TI Camera malfunctions by Pelco’s technical support team.
1. Click System and select Log Files. The Status tab displays a list of logs (example):
Figure 5-63: System Window - Logs Tab
2. To refresh the list click .
5-57
Page 88
5.11.3 Date and Time Tab
Time synchronization is extremely important for the ONVIF
handshake. If the time is not correctly synchronized, the camera may
not connect over ONVIF.
The Date and Time tab allows synchronizing of the Sarix TI Camera time and date according to
several methods:
Click System and select the DATE & TIME tab. The Date & Time tab opens:
Figure 5-64: System Window - Date and Time Tab
Sarix TI Series Camera User Manual Chapter 5: Operation
CAUTION
5-58
Page 89
Chapter 5: Operation Sarix TI Series Camera User Manual
5.11.3.1 Synchronizing with Browser Time
Select the Synchronize with browser time option. The following opens:
Figure 5-65: System Window - Date and Time Tab - Synchronizing with Browser Time
5.11.3.2 Synchronizing with NTP
Select the Synchronize with NTP option. The following opens:
Figure 5-66: System Window - Date and Time Tab - Synchronizing with NTP
5-59
Page 90
5.11.4 File Upload Tab
The File Upload tab allows updating your Sarix TI Camera with FM/SW.
1. Click System and select the FILE UPLOAD tab. The File Upload tab opens:
Figure 5-67: System Window - File Upload Tab
2. Click to browse and select the required FM/SW file (*.tgzx file
format).
Sarix TI Series Camera User Manual Chapter 5: Operation
3. Click UPLOAD FILE. The uploading process is started. On completion, the
RESTART button is valid.
4. Click to validate the Sarix TI Camera with the FM/SW uploading
process.
5.11.5 User Management Tab
The User Management tab is used to manage user’s login permissions.
Click System and select the User Management tab. The User Management tab opens:
Figure 5-68: System Window - User Management Tab
5-60
Page 91
Chapter 5: Operation Sarix TI Series Camera User Manual
5.11.5.1 Adding a User
To add a new user:
1. Click . The following opens:
Figure 5-69: System Window - User Management Tab - Adding a User
2. Enter the User Name.
3. From the User Role drop-down list select the usage-level of the user:
4. Click to validate the changes.
5-61
Page 92
5.11.5.2 Editing User Details
1. Select a user and click .
Figure 5-70: System Window - User Management Tab - Editing User Details
Sarix TI Series Camera User Manual Chapter 5: Operation
2. Change the user details.
3. Click to validate the changes.
5.12 Logging Out from the Web GUI
4. Stop any action, currently in process.
5. From the upper-right drop-down menu select Logout:
Figure 5-71: Logging Out from the Web GUI - Drop Down Menu
The user is logged out from the program and the Status window re-opens (see Figure 5-2).
5-62
Page 93
Chapter 6: Maintenance Sarix TI Series Camera User Manual
6. Maintenance
This chapter provides the Sarix TI Series Camera preventive maintenance instructions.
Chapter 8: Index Sarix TI Series Camera User Manual
8. Index
This chapter provides a list, arranged in alphabetical order, of keywords found throughout this
manual.
Streaming Window · 5-21
A
Abbreviations · 1-11
System Window · 5-51
GUI · 2-17
C
Certificates
Request · 5-19
Self-Signed Request · 5-19
Uploading a Certificate · 5-20
Cleaning · 6-63
D
Day Tab · 5-12, 5-25
Main Stream · 5-25
Secondary Stream · 5-27
Disable Camera · 5-13
E
Enable Camera · 5-14
F
Features · 2-14
I
Image Processing Window · 5-29
Day Tab · 5-37
Day Tab Geometry Settings · 5-38
Day Tab Misc Properties Settings · 5-39
Thermal Tab · 5-29
Thermal Tab Advanced Settings · 5-33
Thermal Tab Basic Settings · 5-30
Thermal Tab Color Processing Settings · 5-34
Thermal Tab Gain Control Settings · 5-32
Thermal Tab Signal Processing Settings · 5-31
Installation · 4-1
Camera Installation · 4-2
Unpacking · 4-1
Installing Camera · 4-2
IP PoE Cable · 4-6
Mechanical Interface Preparation · 4-2, 4-3
Pole Mount Configuration · 4-5
G
General Configuration Tab · 5-28
Getting Started
Changing Password · 5-5
Image Processing Window · 5-29
Live View Window · 5-7
Logging Into GUI · 5-3
Logging Out · 5-62
Main Window · 5-6
Network Window · 5-15
Status Window · 5-8
8-65
Wall Mount Configuration · 4-4
L
Live View Window · 5-7
LOF ·
Logging Out · 5-62
Login · 5-3
LOT · 1-7
1-7
M
Main Window Overview · 5-6
Page 96
Sarix TI Series Camera User Manual Chapter 8: Index
Maintenance · 6-63
Cleaning · 6-63
Visual Inspection · 6-63
N
Network Window · 5-15
Certificates · 5-19
HTTPS Connection · 5-17
IP Address · 5-16
IP Address - Auto · 5-16
Manual DNS Server Address · 5-17
ONVIF Service · 5-18
Resetting Network Settings · 5-18
O
Operation · 5-1
Ordering Info · 7-64
Overview · 2-13, 2-14
Features · 2-14
GUI · 2-17
Physical Description · 2-15
Specifications · 2-18
Maintenance · 3-2
Scope · 1-12
Specifications · 2-18
CMOS Camera · 2-20
Configurations · 2-19
System Specifications · 2-18
Thermal Camera · 2-20
Status Window · 5-8
Status Window Overview
Day Tab · 5-12
Disable Camera · 5-13
Enable Camera · 5-14
System Tab · 5-9
Thermal Tab · 5-10
Streaming Window · 5-21
Day Tab · 5-25
General Configuration Tab · 5-28
Thermal Tab · 5-21
System Tab · 5-9
System Window · 5-51
Admin Tab · 5-51
Admin Tab - Archive System Files · 5-52
P
Password Change · 5-5
Physical Description · 2-15
R
Revisions · 1-1
S
Safety · 3-1
Safety Conventions · 3-1
Safety During Installation · 3-2
Safety During Maintenance · 3-2
Safety Instructions
Conventions · 3-1
Installation · 3-2
8-66
Admin Tab - Export Site · 5-54
Admin Tab - Factory Defaults · 5-55
Admin Tab - Restart · 5-51
Admin Tab - Save As Site · 5-53
Admin Tab - Site Defaults · 5-54
Date & Time Tab · 5-58
Date & Time Tab - Sync with Browser · 5-59
Date & Time Tab - Sync with NTP · 5-59
File Upload Tab · 5-60
Logs Tab · 5-57
User Management Tab · 5-60
User Management Tab - Adding a User · 5-61
User Management Tab - Editing a User · 5-62
T
Thermal Tab · 5-10, 5-21
Page 97
Chapter 8: Index Sarix TI Series Camera User Manual
Main Stream · 5-22
Secondary Stream · 5-24
TOC · 1-2
U
Unpacking · 4-1
V
Visual Inspection · 6-63
8-67
Page 98
Sarix TI Series Camera User Manual Chapter 8: Index
Pelco, Inc.
625 W. Alluvial Ave.
Fresno, CA 93711
Tel. +1 559-292-1981
www.pelco.com
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication
are trademarks of Pelco, Inc. or its affiliates. ONVIF and the ONVIF logo are trademarks of ONVIF Inc.
All other product names and services are the property of their respective companies.
Product specifications and availability are subject to change without notice.