Pelco EWM, EPM, ECM101, EPP2 installation manual

INSTALLATION
EspritĀ® Enhanced Mounts
EWM, EPM, ECM101, EPP2
Wall, Pole, Corner, and Pedestal
C1356M-A (9/18)
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Use only installation methods and materials capable of supporting four times the maximum specified load.
3. Use stainless steel hardware to fasten the mount to outdoor surfaces.
4. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between the mount and mounting surface.

Description

This manual contains the installation instructions for the following EspritĀ® Enhanced mounts:
NOTE: Esprit Enhanced mounts do not ship with conduit fittings or mounting hardware, unless noted otherwise.
EWM Wall Mount: Use to mount an Esprit Enhanced system directly to a vertical load bearing surface.
Qty Description
1Wall mount 1 Conduit plate 1 Gasket 3 10-32 x 3/4-inch Philips flat head screws 2 Sealing glands
EPM Pole Mount: Use with EWM to mount an Esprit Enhanced system to a pole.
Qty Description
1 Pole mount 3 Stainless steel straps 4 3/8-inch flat washers 4 5/16-18 nuts 4 5/16-inch lock washers
ECM101 Corner Mount: Use with EWM to mount an Esprit Enhanced system to a building corner.
Qty Description
1 Corner mount 1 Corner mount with 5/16-18 x 1.25-inch studs 4 3/8-inch flat washers 4 5/16-18 nuts 4 5/16-inch lock washers
EPP2 Pedestal Adapter: Use to mount an Esprit Enhanced system directly to a pedestal mount; includes pedestal adapter only.
Qty Description
3 10-32 x 1/2-inch Phillips flathead screws
2 C1356M-A (9/18)

Installation

SEALING GLAND
KNOCKOUT
NOTE: Before installing any mount or Esprit Enhanced system, refer to Video and Power Cable Wiring Distances on page 5.

EWM ESPRIT WALL MOUNT

1. Remove one or both knockouts from the conduit plate.
2. Using the plate as a template, mark the conduit and fastener positions on the mounting surface.
3. Prepare the mounting surface.
Figure 1. Conduit Plate Knockouts and Sealing Glands
4. Install conduit fittings (not supplied) or sealing glands (supplied) in the conduit plate (refer to Figure 1).
5. Attach the gasket (supplied) to the end of the EWM mount.
Figure 2. Attaching the Gasket to the EWM
6. Thread the wiring/cabling through the conduit plate/sealing glands and the EWM mount.
7. Use mounting hardware (not supplied) to secure the EWM to the mounting surface.
8. Refer to the manual supplied with the Esprit system to complete the installation.
C1356M-A (9/18) 3