Pelco DX8100-512RAM User Manual

DX8100-512RAM

Installation Manual

DX8100
Digital Video Recorder
C2634M (5/07)
Introduction
The following instructions serve as a guide for the installation of the DX8100-512RAM memory expansion module.
Qty Description
1 512 MB double data rate (DDR) dual in-line memory module (DIMM)
1 Adhesive-backed upgrade part label

TOOLS NEEDED

1 Phillips-head screwdriver #1 (nonmagnetic)
1 Properly grounded ESD wrist strap and mat
4 Small containers for storing screws (optional)
Figure 1. 512 MB DIMM Module
C2634M (5/07) 3
Getting Ready
1. Familiarize yourself with the instructions throughout this manual.
2. Check that you have all the necessary parts and tools. Refer to the Parts List and Tools Needed sections.
3. Shut down the DX8100 Series DVR unit. Refer to DX8100 Installation Manual or Operations and Programming Manual for instructions on shutting down your unit.
4. Unplug the power cord from the wall socket and then from the rear of the DVR.
WARNING: For safety reasons, you must remove the power cord because current continues to flow through the DX8100 even when the unit is off. Remove the power cord from the wall socket first and then from the rear of the DVR. It is critical that the unit be unplugged for your safety.
Figure 2. Removing Power Cord from Wall
4 C2634M (5/07)
Figure 3. Removing Power Cord from Unit
5. Ensure that the DX8100 Series DVR and all of its components are protected against electrostatic discharge (ESD). Before handling any electronic components, you should take steps to ground yourself properly so that any built-up static electric charges are dissipated away from the unit. The most effective method for combating ESD is to use a properly grounded wrist strap.
NOTE: If you do not have access to a grounded wrist strap, you can discharge any built-up static by periodically touching an unpainted section of the chassis.
Figure 4. ESD Protection
C2634M (5/07) 5
Prepare Unit for RAM Installation

OPEN THE UNIT CHASSIS

WARNING: The chassis assembly includes parts with sharp edges. To avoid injury, use caution when
working in and around the DX8100’s chassis and components.
1. If the DX8100 is mounted in a rack, remove it and transport it to an area that will provide full access to the unit chassis:
a. Disconnect any cables or connections that might restrict access to or the removal of the unit.
b. Unscrew the fasteners that are securing the unit in the rack.
c. Carefully lift the unit out of the rack.
NOTE: Removing the DX8100 from a rack may require more than one person. Refer to the DX8100 Installation Manual for rack mounting information.
2. Place the DX8100 on a flat surface with ample workspace.
6 C2634M (5/07)
Loading...
+ 14 hidden pages