Partlow 1160+, 1800+, 1400+ Temperature & Process Controllers
Jumperless Configuration Auto Detected Hardware Process & Loop Alarms Modbus & ASCII Comms Auto or Manual Tuning Heat/Cool Operation Ramping Setpoint Remote/Dual Setpoint Options Available in 1/16, 1/8 & 1/4 DIN Formats
With their improved interface, technical functionality and field flexibility, the Partlow 1160+, 1800+ and 1400+ give
you the best in comprehensive control for most temperature and process control loops.
Specification
Features
Control Types Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat only or heat & cool Auto/Manual
Output Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process value or
Alarm 1 & 2 Types Process high, process low, SP deviation, band, logical OR / AND. Also 1 loop alarm for process control
Human Interface 4 button operation, dual 4 digit 10mm & 8mm high (6100+, 8100+) and 13mm & 10mm high (4100+)
PC Configuration Off-line configuration from PC serial port to dedicated config socket (comms option not required).
Input
Thermocouple J, K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%. RTD 3 Wire PT100, 50 per lead maximum (balanced) DC Linear 0 to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V.
Impedance >10M for Thermocouple and mV ranges, 47K for V ranges and 5 for mA ranges Accuracy ±0.1% of input range ±1 LSD (T/C CJC better than 1°C) Sampling 4 per second, 14 bit resolution approximately Sensor Break Detection <2 seconds (except zero based DC ranges), control O/P’s turn off, high alarms activate for T/C and mV
Outputs & Operations
Control & Alarm Relays Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations Control SSR Driver Outputs Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz DC Linear Outputs 0 to 20mA, 4 to 20mA into 500 max, 0 to 10V, 2 to 10V, 0 to 5V into 500 min.
Transmitter Power Supply Output 24VDC (nominal) into 910 minimum to power external devices Communications 2 Wire RS485, 1200 to 19200 Baud, Modbus and ASCII protocol (selectable)
setpoint
security. Process alarms have adjustable hysteresis.
LED displays, optional choice of colours (Red/Red, Red/Green, Green/Red or Green/Green), plus 5 LED indicators
Configuration Software for Windows 98 or higher. West Part Number: PS1-CON
Scaleable -1999 to 9999, with adjustable decimal point
ranges, low alarms activate for RTD, mA or V ranges
Drive capability >10V DC in 500 minimum
Control outputs have 2% over/under drive applied. Accuracy ±0.25% at 250 (degrades linearly to 0.5% for increasing burden to specified limits)
Ref DS-Px100-1209-1-EN
© West Control Solutions 2009
Page 2
(app
Digital Input Selects between 2 setpoints or Auto/Manual control. Volt free or TTL input
45
Remote Setpoint Input 0 to 20mA, 4 to 20mA, 0 to 5V, 1 to 5V, 0 to 10V or 2 to 10V. Scaleable -1999 to 9999. Local/Remote
Operating & Environmental
Temperature & RH
Power Supply
Front Panel Protection
Standards
Dimensions 1160+
setpoint selected from front panel
0 to 55°C (-20 to 80°C storage), 20% to 95% RH non-condensing
100 to 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts)
IEC IP66 (Behind panel protection is IP20)
CE, UL & ULC recognised
10mm (approx.)
110mm 48mm
x 45mm
+0.5 –0.0
48mm
1800+
48mm
100mm
10mm
rox)
96mm
1400+
96mm
100mm
Cut out
92mm +0.5
96mm
10mm Approx
92mm +0.5
Ref DS-Px100-1209-1-EN
© West Control Solutions 2009
Page 3
Wiring Connections
1160+
1800+/1400+
Field Reconfiguration
Input
Jumper-free configuration for any type
(no extra parts required)
Option Slot 1
Relay Output ........................... PO1-C10
Linear mA/V DC Output .......... PO1-C21
SSR Driver Output .................. PO1-C50
Triac Output ............................ PO1-C80
Option Slot 2 Part Number
Relay Output ........................... PO2-C10
Linear mA/V DC Output .......... PO2-C21
SSR Driver Output .................. PO2-C50
Triac Output ............................ PO2-C80
Option Slot 3 Part Number
Relay Output ........................... PO2-C10
Linear mA/V DC Output .......... PO2-C21
SSR Driver Output .................. PO2-C50
24VDC Transmitter PSU ........ PO2-W08
Option Slot A Part Number
Digital Input ............................ PA1-W03
Remote Setpoint Input ........... PA1-W04
RS485 Comms ...................... PA1-W06
Field Reconfiguration
Input
Jumper-free configuration for any type
(no extra parts required)
Option Slot 1
Relay Output ........................... PO1-C10
Linear mA/V DC Output .......... PO1-C21
SSR Driver Output .................. PO1-C50
Triac Output ............................ PO1-C80
Option Slot 2 Part Number
Relay Output ........................... PO2-C10
Linear mA/V DC Output .......... PO2-C21
SSR Driver Output .................. PO2-C50
Triac Output ............................ PO2-C80
Option Slot 3 Part Number
Relay Output ........................... PO2-C10
Linear mA/V DC Output .......... PO2-C21
SSR Driver Output .................. PO2-C50
24VDC Transmitter PSU ....... PO2-W08
Option Slot A Part Number
Digital Input ............................. PA1-W03
Remote Setpoint Input ............ PA1-W04
RS485 Comms ....................... PA1-W06
Option Slot bB Part Number
Full Remote Setpoint input .... PB1-W0R
Ref DS-Px100-1209-1-EN
© West Control Solutions 2009
Page 4
Order Code
MODEL
1/16 DIN Controller 1/8 Din Controller ¼ DIN Controller OPTION SLOT 1 No Output 0 Relay 1 SSR Driver 2 Linear DC 3 Triac 8 OPTION SLOT 2 No Output 0 Relay 1 SSR Driver 2 Linear DC 3 Triac 8 OPTION SLOT 3 No Output 0 Relay 1 SSR Driver 2 Linear DC 3 Transmitter power Supply 4 OPTION SLOT A / DISPLAY COLOR No Option A Red Upper/Red Lower 0 RS485 Serial Comms Red Upper/Red Lower 1 No option A Green Upper/Red Lower 2 RS485 Comms Green Upper/Red Lower 3 No Option A Red Upper/Green Lower 4 RS485 Comms Red Upper/Green Lower 5 No Option A Green Upper/Green Lower 6 RS485 Comms Green Upper/Green Lower 7 Digital input Red Upper/Red Lower 8 Digital input Green Upper/Red Lower 9 Digital input Red Upper/Green Lower A Digital input Green Upper/Green Lower B Basic Remote Setpoint Red Upper/Red Lower C Basic Remote Setpoint Green Upper/Red Lower D Basic Remote Setpoint Red Upper/Green Lower E Basic Remote Setpoint Green Upper/Green Lower F VOLTAGE 100-240 VAC 0 0 24-48V AC/DC 0 2 Options below are for 1/8 and ¼ DIN controllers only Remote Setpoint (full with digital input) R R 24-48V AC/DC & Remote Setpoint (full with digital input) R 2
P
1 1 6 0 1 8 0 0 1 4 0 0
Austria T:+43 (0)2236 691 121 AT@West-CS.com
China T:+86 22 8398 8098 CN@West-CS.com
France T:+33 (1) 77 80 90 42 FR@West-CS.com
Germany T:+49 (0)561 505 1307 DE@West-CD.com
United Kingdom T:+44 (0)1273 606271 UK@West-CS.com
USA T:+1 800 866-6659 NA@West-CS.com
Email Enquiries@West-CD.com
Website www.West-CS.com
For more details on the complete product range from West Control Solutions please contact your local distributor or visit www.West-CS.com
Ref DS-Px100-1209-1-EN
© West Control Solutions 2009
Loading...