Paradox MAGELLAN K10V/H, Magellan K10V, Magellan K10H User Quick Reference Manual

K10V/H - User’s Quick Reference Guide
KEYPAD OVERVIEW
= Press once + [MASTER
CODE
] for Quick Menu
Programming
Zone Display:
Keys [1] to [0(10)] correspond to zones 1 to 10 respectively. Key Lit: Open or entry delay Key Flash: In alarm
Partition 1 Status
Partition 2 Status
On = StayD Mode Enabled
Arm (red), Sleep (yel), Stay (grn): On = Partition armed
Off = Partition disarmed Flash = Exit Delay
Fast Flash* = Exit Delay (final 10
sec.)
Fast Flash* = Partition in alarm
* Audible Indicators: Continuous beep = Alarm Variable beep = Fire alarm Intermittent beep = Beginning of
exit delay Fast beep = Final 10 sec. of exit
delay
AC Light
On = Power on Off = Power off
[TBL] Trouble display On = Trouble(s) occurring
[
MEM] Alarm memory display
On = Alarm(s) occurred
[
BYP] Bypass programming
On = Zone(s) bypassed
To Regular Arm:
1. Close all zones in the desired partition.
2. Press [
ARM].
3. Enter your [
ACCESS CODE]*.
To Stay Arm:
1. Press the [
STAY] key.
2. Enter your [
ACCESS CODE]*.
To Sleep Arm:
1. Press the [
SLEEP] key.
2. Enter your [
ACCESS CODE]*.
* If needed, press button(s) corresponding to desired partition(s). For two partitions, press the other key after the confirmation beep.
ARMING AND DISARMING
TO ARM
WHEN LEAVING...
TO ARM
WHEN STAYING...
To Disarm:
[
OFF] + [ACCESS CODE]*
Bypassed zones remained unarmed when the partition is armed.
1. Press the [
BYP] key.
2. Enter your [
ACCESS CODE]*.
3. The corresponding key of all open zones will illuminate. Select the zone(s) you want to bypass by entering the one-digit zone number. The zone key will flash.
4. Press the [
ENTER] key to save
and exit.
A Chime Enabled zone will advise you every time it is opened by causing your keypad to beep.
1. Press & hold the corresponding zone key for 3 seconds (Accept beep = Chime enabled, Fail beep = Chime disabled).
BYPASS PROGRAMMING
CHIME PROGRAMMING
© Paradox Security Systems Ltd., 2005-2015. Magellan is a trademark or registered trademark of Paradox Security Systems (Bahamas) Ltd. and its affiliates in Canada, the United States and/or other countries. All rights reserved.
PARADOX.COM
Printed in Canada 11/2015 K10VH-EQ04
To send a silent or audible alarm to your Security Company, press and hold one of the button combinations listed for 3 seconds.
When a trouble condition occurs, the
[
TBL] key will illuminate.
1. Press the [
TBL] key. The key will
flash and number(s) correspond­ing to the trouble(s) will illumi­nate.
2. Read the corresponding explanation from the trouble list in the MG5000 User Guide.
3. Press the [
CLEAR] key to exit.
To view the alarms that occurred during the last armed period:
1. Disarm the system.
2. Press the [
MEM] key.
3. The corresponding zone numbers that were in alarm the last time the system was armed will illuminate.
4. Press the [
CLEAR] key to exit.
To mute the keypad:
Press and hold the [
CLEAR] key
for 6 seconds to enable or disable Keypad Muting.
To modify the backlight:
1. Press and hold the [
MEM] key for
3 seconds.
2. The [
MEM] key will illuminate.
3. Press the [
MEM] key to set the
desired backlight level.
4. Press [
CLEAR] or [ENTER] to exit.
PANIC ALARMS
Panic Alarm Type Button
Combinations
Police Medical Fire
Press [1] & [3] Press [4] & [6] Press [7] & [9]
TROUBLE DISPLAY
ALARM MEMORY DISPLAY
KEYPAD SETTINGS
Loading...