Instructions
Ceiling Mount Bracket
Model No. WV-Q169
ENGLISH
FRANÇAIS
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
CONTENTS |
|
Preface ....................................................................................................................................... |
2 |
Precautions ................................................................................................................................ |
2 |
Major Operating Controls and Their Functions .......................................................................... |
4 |
Installations ................................................................................................................................ |
4 |
Specifications ............................................................................................................................. |
9 |
Standard Accessories ................................................................................................................ |
10 |
Preface |
|
The WV-Q169 is a ceiling embedded bracket that is exclusively designed to mount the color CCTV camera: WV-CW504F, WV-CW504S, and Network camera: WV-NW484S, WV-NW502S, on a ceiling. This bracket can be used for an area with weak pull-out strength such as plasterboard in a double ceiling, and the embedded type makes the visible part of the camera smaller.
Precautions
All work related to the installation of this product should be made by qualified service personal or system installer.
Use this apparatus for indoor use only.
Installation area
•Consult the dealer about the installation area to select a strong ceiling area. Make sure that the installation area is strong enough to hold the total weight of the camera assembly before installation.
Refer to the following about the weight of the camera assembly in accordance with the model:
•WV-NW484S: approx. 2.2 kg {4.85 lbs}
•WV-NW502S: approx. 2.15 kg {4.75 lbs}
•WV-CW504S: approx. 2.05 kg {4.53 lbs}
•WV-CW504F: approx. 2.05 kg {4.53 lbs}
•The installation area shall have 210 mm {8-1/4"} or more space behind the ceiling.
•The thickness of the ceiling board for installation can range from 9 to 40 mm {3/8" to 1- 9/16"}.
210 mm {8-1/4"} or more
Ceiling board: from 9 to 40 mm {3/8" to 1-9/16"}
2
Avoid installing in the following locations.
•Locations where it may get wet from rain or water splash
•Locations where a chemical agent is used such as a swimming pool (not only outdoor)
•Locations subject to steam and oil smoke such as a kitchen
•Locations where radiation or x-ray emissions are produced
•Locations where it may be damaged by briny air such as seashores
•Locations where the temperature is not within –30 °C to +50°C {–22 °F to 122 °F}.
•Locations subject to vibrations (This product is not designed for on-vehicle use.)
•Locations where the temperature may rapidly change such as the peripheral areas of the air outlets of air conditioners or doors facing outside. (In case of installing the camera in such locations, the dome cover may become foggy or condensation may be caused on the cover.)
Tightening the screws and bolts
•The screws and bolts must be tightened with an appropriate tightening torque according to the material and strength of the installation area. After tightening the screws or bolts, perform visual check to ensure tightening is enough and there is no backlash.
•Required pull-out capacity of a single screw/bolt is 196 N {44.1 lbf} or more.
Do not rub the edges of metal parts with your hand.
Failure to observe this may cause injury.
Be sure to remove this apparatus if it is not in use.
Be sure to install the safety wire.
Use the specified camera only.
Failure to observe this may cause a fall of an inappropriate camera resulting in injury or accidents. Mount WV-CW504F, WV-CW504S, WV-NW484S, WV-NW502S on this bracket exclusively.
Periodic inspections shall be conducted.
Rust on the metal parts or screws may cause a fall of the product resulting in injury. Consult the dealer for the inspections.
ENGLISH
3
Major Operating Controls and Their Functions
Roof space
Safety wire angle (Accessory)
Safety wire (Accessory)
Roof space
WV-CW504F, WV-CW504S,
WV-NW484S, WV-NW502S
*Read the manual of the camera as well.
Installations
Be sure to read "Precautions" on the page 2 before installation. The manual of the camera, WV- CW504F,WV-CW504S, WV-NW484S, WV-NW502S shall be read as well.
1. Put Template A (accessory) against the ceiling and make a hole.
q Make 4 holes of 12 mm {1/2"} in diameter.
wRemove the center part from the template.
eMake a hole of 180 mm {7-1/16"} in diameter.
The ceiling holes are shown in the drawing at right. →
Ceiling face |
ø12 mm {1/2"} |
|
(4 positions) |
||
|
ø180 mm {7-1/16"}
Template A
4
2. Install two anchor bolts (locally procured: M10 recommended) into the concrete ceil-
ing.
q Install an anchor bolt in the center of the hole made in the step 1.
wDetermine the anchor bolt length by use of Template B (accessory).
eUse Template B (accessory) to decide the nut position, and fix it.
(Mount the nut so that the distance between the bottom surfaces of the nut and ceiling is adjusted to 134 mm {5-1/4"}.)
2nd Anchor bolt (locally procured)
Anchor bolt
Template B
Ceiling board
1st Anchor bolt (locally procured)
Nut (locally procured)
Determine the anchor bolt length
134 mm {5-1/4"}
Install the anchor bolt in the center of the hole
Note: If there is already an anchor bolt installed, the anchor bolt can be used as a 2nd anchor bolt. Make sure that the distance between the 1st and 2nd anchor bolts is 1 000 mm {3.28'} or less before use.
3. Mount the safety wire angle (accessory) on the 2nd anchor bolt and connect the safe-
ty wire (accessory) to the angle.
qDisconnect the safety wire from the safety wire angle.
wEngage the face marked q with the anchor bolt.
e Bend the face marked w.
rConnect the safety wire to the safety wire angle again.
Anchor bolt
w Insert
q Disconnect
Safety wire
Mark q
Upper side
Mark w
e Bend
Lower side
Safety wire angle
r Connect
Note: To use the anchor bolt that was already installed, the use of 2 spacer nuts (locally procured) is helpful.
|
|
|
|
|
Spacer nuts |
|
|
|
|
|
|
|
|
Spacer nuts |
|
|
|
|
|
|
|
|
|
|
|
|
|
(locally procured) |
|
|
|
|
|
|
|
|
|
|
Safety wire angle |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Safety wire |
||||
|
||||||
|
|
|
|
|
|
|
|
|
|
|
Existing anchor bolt |
||
|
|
|
||||
|
|
|
|
|
|
|
5
4.Connect this mount bracket to the tip of the safety wire.
Roof space
Important: When securing this bracket on the ceiling, make sure that the four ceiling board fixing brackets are open as shown in the following figure.
1st anchor bolt
Safety wire (Accessory) |
Insert the mount |
|
bracket into the hole |
Double nuts (locally procured)
Mount bracket |
|
|
Ceiling board |
5. Insert the 1st anchor bolt into the |
fixing bracket |
Ceiling board |
|
mounting hole of the mount bracket. |
|
Ceiling board fixing screw
Mounting hole
Turn clockwise
6.Secure the mount bracket to the ceiling board with the ceiling board fixing screws (4 positions).
Turning the ceiling board fixing screws clockwise provides ceiling board tightening between the bottom of the mount bracket and ceiling board fixing bracket resulting in mount bracket securing.
(Recommended tightening torque: 0.78 N·m {0.58 lbf·ft})
7.Use double nuts (locally procured) to secure the mount bracket after inserting the 1st anchor bolt.
8.Follow the procedure according to the model of the camera to be installed.
<Installing WV-NW484S>
qUse the driver bit supplied with the camera to remove the screws that secure the camera enclosure and remove the enclosure from the camera main body.
Important: Refer to the Operating instructions of the camera as well.
w Perform camera wiring.
eAlign the screw holes of the mount bracket with the 4 mounting screws of the camera main body and tighten them. (Recommended tightening torque:
0.78N·m)
6