Ceiling Mount Bracket
Model No. WV-Q169
FRANÇAIS ENGLISH
All work related to the installation of this product should be made by qualified service personal or system installer.
Installation area
• Consult the dealer about the installation area to select a strong ceiling area. Make sure that the installation area is strong enough to hold the total weight of the camera assembly before installation. Refer to the following about the weight of the camera assembly in accordance with the model:
• WV-NW484S: approx. 2.2 kg {4.85 lbs}
• WV-NW502S: approx. 2.15 kg {4.75 lbs}
• WV-CW504S: approx. 2.05 kg {4.53 lbs}
• WV-CW504F: approx. 2.05 kg {4.53 lbs}
• The installation area shall have 210 mm {8-1/4"} or more space behind the ceiling.
• The thickness of the ceiling board for installation can range from 9 to 40 mm {3/8" to 1­9/16"}.
210 mm {8-1/4"} or more
Ceiling board: from 9 to 40 mm {3/8" to 1-9/16"}
2
CONTENTS
Preface ....................................................................................................................................... 2
Precautions ................................................................................................................................ 2
Major Operating Controls and Their Functions .......................................................................... 4
Installations ................................................................................................................................ 4
Specifications ............................................................................................................................. 9
Standard Accessories ................................................................................................................ 10
Precautions
Preface
The WV-Q169 is a ceiling embedded bracket that is exclusively designed to mount the color CCTV camera: WV-CW504F, WV-CW504S, and Network camera: WV-NW484S, WV-NW502S, on a ceiling. This bracket can be used for an area with weak pull-out strength such as plaster­board in a double ceiling, and the embedded type makes the visible part of the camera small­er.
3
Avoid installing in the following locations.
• Locations where it may get wet from rain or water splash
• Locations where a chemical agent is used such as a swimming pool (not only outdoor)
• Locations subject to steam and oil smoke such as a kitchen
• Locations where radiation or x-ray emissions are produced
• Locations where it may be damaged by briny air such as seashores
• Locations where the temperature is not within –30 °C to +50°C {–22 °F to 122 °F}.
• Locations subject to vibrations (This product is not designed for on-vehicle use.)
• Locations where the temperature may rapidly change such as the peripheral areas of the air outlets of air conditioners or doors facing outside. (In case of installing the camera in such locations, the dome cover may become foggy or condensation may be caused on the cover.)
Tightening the screws and bolts
• The screws and bolts must be tightened with an appropriate tightening torque according to the material and strength of the installation area. After tightening the screws or bolts, per­form visual check to ensure tightening is enough and there is no backlash.
• Required pull-out capacity of a single screw/bolt is 196 N {44.1 lbf} or more.
Do not rub the edges of metal parts with your hand.
Failure to observe this may cause injury.
Be sure to remove this apparatus if it is not in use.
Be sure to install the safety wire.
Use the specified camera only.
Failure to observe this may cause a fall of an inappropriate camera resulting in injury or acci­dents. Mount WV-CW504F, WV-CW504S, WV-NW484S, WV-NW502S on this bracket exclusive­ly.
Periodic inspections shall be conducted.
Rust on the metal parts or screws may cause a fall of the product resulting in injury. Consult the dealer for the inspections.
ENGLISH
4
Major Operating Controls and Their Functions
Roof space
Safety wire angle (Accessory)
Safety wire (Accessory)
* Read the manual of the camera as
well.
Installations
Be sure to read "Precautions" on the page 2 before installation. The manual of the camera, WV­CW504F,WV-CW504S, WV-NW484S, WV-NW502S shall be read as well.
1. Put Template A (accessory) against the ceiling and make a hole.
q Make 4 holes of 12 mm {1/2"} in diameter. w Remove the center part from the tem-
plate.
e Make a hole of 180 mm {7-1/16"} in diam-
eter. The ceiling holes are shown in the drawing at right.
Ceiling face
ø12 mm {1/2"} (4 positions)
ø180 mm
{7-1/16"}
Template A
Roof space
WV-CW504F, WV-CW504S, WV-NW484S, WV-NW502S
2. Install two anchor bolts (locally procured: M10 recommended) into the concrete ceil­ing.
q Install an anchor bolt in the
center of the hole made in the step 1.
w Determine the anchor bolt
length by use of Template B (accessory).
e Use Template B (accessory) to
decide the nut position, and fix it. (Mount the nut so that the dis­tance between the bottom sur­faces of the nut and ceiling is adjusted to 134 mm {5-1/4"}.)
Note: If there is already an anchor bolt installed, the anchor bolt can be used as a 2nd anchor
bolt. Make sure that the distance between the 1st and 2nd anchor bolts is 1 000 mm {3.28'} or less before use.
3. Mount the safety wire angle (accessory) on the 2nd anchor bolt and connect the safe­ty wire (accessory) to the angle.
q Disconnect the safety wire from the safe-
ty wire angle.
w Engage the face marked q with the
anchor bolt.
e Bend the face marked w. r Connect the safety wire to the safety wire
angle again.
Note: To use the anchor bolt that was already installed, the use of 2 spacer nuts (locally pro-
cured) is helpful.
5
Anchor bolt
Nut (locally procured)
Template B
Determine the anchor bolt length
Ceiling board
Install the anchor bolt in the center of the hole
134 mm
{5-1/4"}
Upper side
Lower side
Safety wire
w Insert
q Disconnect
e Bend
Mark w
Mark q
r Connect
Safety wire angle
Anchor bolt
Spacer nuts (locally procured)
Safety wire
Spacer nuts
Safety wire angle
Existing anchor bolt
2nd Anchor bolt (locally procured)
1st Anchor bolt (locally procured)
6
Important: When securing this bracket
on the ceiling, make sure that the four ceiling board fixing brackets are open as shown in the following fig­ure.
7. Use double nuts (locally procured) to secure the mount bracket after insert­ing the 1st anchor bolt.
8. Follow the procedure according to the model of the camera to be installed.
<Installing WV-NW484S>
q Use the driver bit supplied with the cam-
era to remove the screws that secure the camera enclosure and remove the enclo­sure from the camera main body.
Important: Refer to the Operating inst-
ructions of the camera as well.
w Perform camera wiring.
e Align the screw holes of the mount
bracket with the 4 mounting screws of the camera main body and tighten them. (Recommended tightening torque:
0.78 N·m)
4. Connect this mount bracket to the tip of the safety wire.
5. Insert the 1st anchor bolt into the mounting hole of the mount bracket.
6. Secure the mount bracket to the ceil­ing board with the ceiling board fixing screws (4 positions).
Turning the ceiling board fixing screws clockwise provides ceiling board tighten­ing between the bottom of the mount bracket and ceiling board fixing bracket resulting in mount bracket securing. (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft})
Safety wire (Accessory)
Roof space
Insert the mount bracket into the hole
Mount bracket
1st anchor bolt
Ceiling board fixing screw
Ceiling board fixing bracket
Turn clockwise
Double nuts (locally procured)
Ceiling board
Mounting hole