PANASONIC WHUD24BE51, WHUD30BE51, WHSD30BE51, WHSD24BE51 User Manual [da, en, no, fi, sv]

WATER OUTLET
OUTDOOR
HEAT
C
C
SETTING STATUS
C
WATER INLET
PUMPDW
ERROR
OFF
Operating Instructions
Air-to-Water Heatpump
0.2
0.1
0.3
0
0.4
MPa
Model No. Indoor Unit
Outdoor Unit
WH-SD24BE5-1 WH-UD24BE5-1 WH-SD30BE5-1 WH-UD30BE5-1
ENGLISH ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and precisely following the installation instructions given.
SVENSKA SVENSKA
Innan du använder enheten, läs noga igenom denna bruksanvisning och spara den för framtida bruk.Innan du använder enheten, läs noga igenom denna bruksanvisning och spara den för framtida bruk.
Innan du använder enheten, se till att installationen har utförts noggrant och korrekt av auktoriserad återförsäljare som följt de givna installationsinstruktionerna.
NORSK NORSK
Les bruksanvisningen nøye før du bruker denne enheten, og oppbevar den for fremtidig bruk.Les bruksanvisningen nøye før du bruker denne enheten, og oppbevar den for fremtidig bruk.
Før du bruker enheten, må du forsikre deg om at autorisert forhandler har utført korrekt og presis installasjon og har fulgt installasjonsinstruksjonene som er gitt.
SUOMI SUOMI
Lue nämä käyttöohjeet huolellisesti ennen yksikön käyttämistä ja säilytä ne tulevaisuutta varten.Lue nämä käyttöohjeet huolellisesti ennen yksikön käyttämistä ja säilytä ne tulevaisuutta varten. Varmista ennen laitteen käyttöä, että asennuksen on suorittanut valtuutettu jälleenmyyjä ja että se on tehty oikein ja Varmista ennen laitteen käyttöä, että asennuksen on suorittanut valtuutettu jälleenmyyjä ja että se on tehty oikein ja tarkasti annettuja asennusohjeita noudattaen.tarkasti annettuja asennusohjeita noudattaen.
DANSKDANSK
Læs brugsanvisningen grundigt igennem før du benytter anlægget og gem den til fremtidig brug.Læs brugsanvisningen grundigt igennem før du benytter anlægget og gem den til fremtidig brug.
Sørg for, at anlægget er installeret korrekt af en autoriseret forhandler i overensstemmelse med de følgende instruktioner, før anlægget tages i brug.
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010. Unauthorized copying and distribution is a violation of law.
2 ~ 92 ~ 9
10 ~ 1710 ~ 17
18 ~ 2518 ~ 25
26 ~ 3326 ~ 33
34 ~ 4134 ~ 41
F567459
Thank you for purchasing Panasonic Product
TABLE OF CONTENTSTABLE OF CONTENTS
SAFETY PRECAUTIONS
PRODUCT OVERVIEW
BASIC OPERATION
ADVANCE OPERATION
CARE & CLEANING
TROUBLESHOOTING
INFORMATION
NOTE :
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
OPERATION CONDITIONOPERATION CONDITION
Water outlet
Temperature (°C)
HEATING
Ambient
Temperature (°C)
HEATING
NOTICE :
2
When the outdoor temperature is out of the above temperature range, the heating capacity will drop signifi cantly and outdoor unit might stop for protection control.
Indoor
Max. 55
Min. 25
Outdoor
Max. 35
Min. -20
2~3
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
• Panasonic Air-to-Water Heatpump is a split system consisting
only of an indoor unit and an outdoor unit. This system designed for combination with Panasonic Tank Unit. In case of non-Panasonic
Tank Unit is being used with Panasonic Air-to-Water Heatpump
System, Panasonic cannot guarantee neither good operation nor reliability of the system.
• This manual describes how to operate the Heatpump system between indoor and outdoor units only.
• Other operation such as water tank, radiator and underfl oor system,
4
5
6
7
8
9
please refer to respective manufacturer operation manuals.
To prevent personal injury, injury to others, or property damage, please comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
WARNINGWARNING
CAUTIONCAUTION
The instructions to be followed are classifi ed by the following symbols:
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not attempt to repair the unit by yourself. Otherwise, it may cause injury if it is mishandling.
Do not install the indoor unit at outdoor. This is designed for indoor installation only.
This sign warns of death or serious injury.
This sign warns of injury or damage to property.
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is COMPULSORY.
WARNINGWARNING
WARNINGWARNING
/
/
POWER SUPPLY
Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
Do not share the same power outlet with other equipment to prevent overheating and fi re.
Do not operate with wet hands to prevent electric shock.
If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
This unit is equipped with Residue Current Circuit Breaker (RCCB). It is strongly recommended to check the operation of the RCCB after installation and periodically after servicing or maintenance by authorized dealer to ensure it is in good working order. Otherwise, it may cause electrical shock or re in case of malfunction.
It is strongly recommended to install Residual Current Device (RCD) on-site to prevent electric shock or fi re.
It is recommended to wear gloves during servicing or maintenance in order to avoid hazard.
This equipment must be earthed to prevent electrical shock or fi re.
Prevent electric shock by switching off the power supply when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity. This appliance is for multiple uses. All power
supply circuits must be turn off before access to any of the terminals in the indoor unit, to avoid electrical shock, burn or fatal injury.
Stop using the product when any abnormality/ failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock)
Examples of abnormality/ failure
• The RCCB switches off by itself.
• Burning smell, abnormal noise or vibration sound is observed when the unit is in use.
• Hot water keeps on coming off the unit.
Contact immediately your local dealer for maintenance/repair.
CAUTIONCAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene, thinner or scouring powder.
Do not install the unit close to any combustible equipment or at bathroom. Otherwise, it may cause electric shock or fi re.
Do not touch the water discharge pipe at the indoor unit during operation.
Do not place anything on top or beneath of the unit.
Do not sit or step on the unit, you may fall down accidentally.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
Ensure drainage pipe is connected properly. Otherwise, leakage may occur.
Check the installation rack periodically to make sure that it is not damaged. After long periods of use, the strength of the installation rack may have deteriorated.
CONTROL PANEL
Do not let the control panel get wet. Otherwise, it may cause electric shock or fi re.
Do not press the buttons on the control panel with hard, pointed objects. Otherwise, it may damage the unit.
Do not wash the control panel with water, benzene, thinner or scouring powder.
not inspect or service the control panel by not inspect or service the control panel by
Do
yourself. Please consult authorized dealer.yourself. Please consult authorized dealer.
Otherwise, it may cause injury if mishandling.
Indoor Unit
Shower
Power Supply
ENGLISH
Panel
Outdoor Unit
Control Panel
Water Tank Unit
Floor Heating
3
PRODUCT OVERVIEW PRODUCT OVERVIEW
Air-to-Water Heatpump Air-to-Water Heatpump Indoor UnitIndoor Unit
Water Pressure Gauge Water Pressure Gauge
Control PanelControl Panel
Open the cover to use the buttons
ER OUTLET
WAT
T
C
HEA
C
ET
ER INL
ON
/
WAT
OFF
WATER OUTLET OUTDOOR
HEAT
CC
SETTING STATUS
C
PUMPDW
WATER INLET ERROR
/ ON
OFF
0.2
0.30.1
0.40
MPa
0.2
0.30.1
0.40
MPa
• Do not press or hit the glass cover with hard, pointed objects. This may damage the unit.
• Ensure that the water pressure is between 0.05 to
0.2 MPa (0.1 MPa = 1 bar).
• In case the water pressure is out of the above range, please consult authorized dealer.
12 13
WATER OUTLET OUTDOOR
11
OOR
OUTD
ING
C
SETT
TUS
STA PUMPDW
OR
ERR
1
2
HEAT
WATER INLET ERROR
SETTING
3
OFF
SET
SELECT
CANCEL
14
10
CC
SETTING
CHECK
STATUS
STATUS PUMPDW
SEARCH
PUMPDW
C
/
ON
ERROR RESET
9 8
7
5
6
4
OFF/ON Button
1
Operation LED
2
System Setting Mode Buttons
3
Error Reset Button
4
System Status Check Mode Buttons
5
System Pumpdown Mode Button
6
System Error Display
7
4
System Pumpdown Mode Indicator
8
System Status Check Mode Indicator
9
System Setting Mode Indicator
10
Heating Operation Indicator
11
Water Outlet Temperature Display
12
Water Inlet Temperature Display
13
Outdoor Ambient Temperature Display
14
BASIC OPERATION BASIC OPERATION
Operation Start / StopOperation Start / Stop
/
ON
WATER INLET ERROR
OFF
SETTING
/
ON
STAT US
• When unit is ON, operation LED is lit and the actual temperature for water outlet, water inlet and outdoor ambient are shown on the control panel display.
/
ON
OFF
• Press
Operation details (Default setting)Operation details (Default setting)
• Operation takes place under default settings as follows:
--When Outdoor ambient temperature (Out Lo) is less than 0°C, water outlet set temperature (H2O Lo) is 50°C. When Outdoor ambient temperature (Out Hi) is more than 15°C, water outlet set temperature (H2O Hi) is 32°C.
• In between the specifi ed outdoor ambient temperature range (Out Lo and Out Hi), the system will automatically adjust the water outlet temperature between specifi ed range (H2O Lo and H2O Hi).
• Lower outdoor ambient temperature will result in higher water outlet temperature and vice versa.
• The unit starts by pressing
OFF
.
again to stop the operation.
ENGLISH
Optional SettingsOptional Settings
ERROR RESET
PUMPDW
Error code reset
• Not usable during normal operation.
System Pump Down
• Not usable during normal operation.
• If accidentally pressed the
PUMPDW
, press
OFF
/
ON
to stop the pump down operation.
5
CANCEL
ADVANCE OPERATION ADVANCE OPERATION
RecommendationRecommendation
• It is strongly recommended to have the authorized dealer to change the water temperature range. The temperature range for water outlet temperature and outdoor ambient temperature could be set by control panel.
Perform the steps below to set preferred temperature range.
SETTING
SET
CHECK
STATUS
1,5
2,4
STEP 1: Press
STEP 2: Press
STEP 3:
STEP 4: Press
STEP 5: Press
• Repeat steps 2 to 5 to set other parameters.
SET
for 5 seconds to enter SETTING mode. “SETTING” indicator is ON.
or to choose a parameter.
H2O Lo: Water outlet set temperature at low outdoor ambient set temperature
H2O Hi: Water outlet set temperature at high outdoor ambient set temperature
Out Lo: Low outdoor ambient set temperature
Out Hi: High outdoor ambient set temperature
Note: Please make sure High outdoor ambient set temperature (Out Hi) is always higher than Low outdoor ambient set temperature (Out Lo).
After selecting the desired parameter, press parameter is selected.
or to set the desired temperature.
SET
again to confi rm the setting.
HEAT
HEAT
HEAT
HEAT
SELECT
CANCEL
SEARCH
ERROR
RESET
PUMPDW
3
C
SETTING STATUS PUMPDW
C
SETTING STATUS PUMPDW
C
SETTING STATUS PUMPDW
C
SETTING STATUS PUMPDW
SELECT
to enter the parameter. “ ” indicator will blink when a
Selection range: 25°C ~ 55°C
Selection range: 25°C ~ 55°C
Selection range:
-15°C ~ 15°C
Selection range:
-15°C ~ 15°C
• Press
or wait 30 seconds to exit SETTING mode.
• The setting temperature will be stored in the system once confi rm.
• “SETTING” mode cannot be activated when the “PUMPDW” and “STATUS” indicator is ON.
6
CARE & CLEANING CARE & CLEANING
CANCEL
• Switch off the power supply before cleaning.
CAUTION
Indoor Unit & Control PanelIndoor Unit & Control Panel
• Do not splash water directly.
• Wipe the unit gently with a soft, dry cloth.
External FilterExternal Filter
• Please clean the external fi lter at least once a year. Fail to do so might cause fi lter clogged, consequent system breakdown. Please consult authorized dealer.
Outdoor UnitOutdoor Unit
• Do not obstruct the air inlet and air outlet vents, it may cause low performance or breakdown. Please remove obstacles to assure the ventilation.
• During winter, please clean and remove the snow near outdoor unit so that the snow does no cover the air inlet and air outlet vents.
Inspection Inspection
• In order to ensure optimal performance of the unit, seasonal inspections on the unit, external fi lter and fi eld wiring have to be carried out at regular intervals. This maintenance should be carried out by authorized dealer.
• Clear any obstruction at the air inlet and air outlet vents of outdoor unit.
For Extended Non-Use For Extended Non-Use
• Turn off the power supply.
Perform the steps below to check system statusPerform the steps below to check system status
ENGLISH
CHECK
STATUS
SEARCH
PUMPDW
STEP 1: Press STEP 2:
Press or to check the Water Inlet Temperature, Tank Temperature, Compressor Running
SETTING
SET
SELECT
CANCEL
CHECK
for 5 seconds to enter STATUS mode.
ERROR
RESET
Frequency or Error History.
• Press
or wait 30 seconds to exit STATUS mode.
• Once STATUS mode is entered, “STATUS” indicator is ON.
• STATUS mode cannot be activated when the “SETTING” indicator is ON.
1
2
7
TROUBLESHOOTING TROUBLESHOOTING
The following symptoms do not indicate malfunction. The following symptoms do not indicate malfunction.
SymptomSymptom CauseCause
Water fl owing sound during operation. • Refrigerant fl ow inside the unit. Operation is delayed a few minutes after
restart. Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes. Outdoor unit emits steam during heating
mode. Outdoor unit does not operate. • When the outdoor temperature is out of the operation condition range,
Air-to-Water Heatpump system operation will turn off.
System diffi cult to heat-up. • When heating is operated by indoor unit together with fl oor heating or
System cannot get warm instantly. • Due to the nature of the heatpump system, it may take some time to
Operation starts after power resumes. • Auto restart is in function and operates under.
• The delay is a protection to the unit’s compressor.
• This is due to defrost operation happens at the heat exchanger.
the heatpump system enter protection control.
• If indoor unit water inlet temperature is lower than 20°C. Please set the heater of tank more than 20°C.
panel heater simultaneously, there may be case where warm water temperature is getting lower and cause fl oor heating or panel heater heat-up is weaken.
• When outdoor air temperature is low, it may be diffi cult to get warm.
• Is the snow pile blocking the discharge outlet or intake inlet of outdoor unit.
• When water outlet set temperature is low, it may be diffi cult to get warm.
heat-up the water if the unit is operated from cold-start.
Check the following before calling for servicing. Check the following before calling for servicing.
SymptomSymptom CheckCheck
Heating operation is not working effi ciently. • Set the temperature correctly.
Noisy during operation. • Check if the unit has been installed at an incline or the cover is not
The unit does not work. • Check if the circuit breaker is tripped. Operation LED is no lit or control panel display
is blank.
The operation LED blinks and error code appear on control panel display.The operation LED blinks and error code appear on control panel display.
• Turn the unit off and reveal the error code to authorized dealer.
8
• Is the panel heater valve closed.
• Clear any obstruction at the air inlet and air outlet vents of outdoor unit.
closed properly.
• Is the power supply off or power failure.
WATER INLET ERROR
INFORMATION INFORMATION
NON SERVICEABLE CRITERIASNON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the control panel.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
Information for Users on Collection and Disposal of Old Equipment
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
ENGLISH
9
Tack för ditt inköp av Panasonic -produkt
INNEHÅLLSFÖRTECKNINGINNEHÅLLSFÖRTECKNING
SÄKERHETSFÖRESKRIFTER
10~11
PRODUKTÖVERSIKT
GRUNDLÄGGANDE ANVÄNDNING
AVANCERAD ANVÄNDNING
UNDERHÅLL & RENGÖRING
PROBLEMLÖSNING
INFORMATION
SÄKERHETSFÖRESKRIFTERSÄKERHETSFÖRESKRIFTER
• Panasonics Luft-till-Vatten-Värmepump är ett split-system som består av endast en inomhusenhet och en utomhusenhet. Det här systemet är tillverkat för att användas med Panasonics ackumulatortank. Om du använder Panasonics Luft-till-Vatten-Värmepump med en ackumulatortank från en annan tillverkare än Panasonic, kan Panasonic varken garantera god prestanda eller tillförlitlig drift.
• I denna manual beskrivs hur du använder värmepumpsystemet mellan inomhus- och utomhusenheterna enbart.
• För annan användning av t.ex. vattentank, värmeelement och
12
13
14
15
16
17
golvvärmesystem, se bruksanvisningen från respektive tillverkare.
För att undvika skada på dig själv, skada på andra, eller skada på egendom, var god iaktta följande. Felaktig användning orsakad av att skötselanvisningen inte följts kan leda till skador, nedan klassas deras allvar:
VARNINGVARNING
FÖRSIKTIGHETFÖRSIKTIGHET
Denna symbol varnar för dödsfara eller allvarliga skador.
Denna symbol varnar för personskada eller skada på egendom.
Instruktioner klassifi ceras med följande symboler:
Denna symbol betecknar en handling som är FÖRBJUDEN.
OBS :
Bilderna i denna skötselanvisning är endast illustrativa och kan därför skilja sig från den faktiska modellen. Förändringar kan göras utan föregående meddelande angående framtida förbättringar.
TILLÅTNA TILLÅTNA DRIFTSFÖRHÅLLANDENDRIFTSFÖRHÅLLANDEN
Vattenutloppstemperatur
(°C)
VÄRME
Omgivningstemperatur
(°C)
VÄRME
MÄRK : Då utomhustemperaturen är
utanför temperaturområdet ovan, sjunker uppvärmningskapaciteten avsevärt och utomhusenheten kan stoppa för skyddskontroll.
10
Inomhus
Max. 55 Min. 25
Utomhus
Max. 35 Min. -20
Denna symbol betecknar ett handhavande som MÅSTE UTFÖRAS.
INOMHUS- OCH UTOMHUSENHETINOMHUS- OCH UTOMHUSENHET
Denna apparat är inte avsedd att användas av personer (inklusive barn) med reducerad fysiska, sensoriska eller mentala färdigheter, eller brist på erfarenhet och kunskap, ifall de inte övervakats eller instruerats om användandet av apparaten av en person som ansvarar för deras säkerhet. Barn bör övervakas för att se till att de inte leker med apparaten.
Var god rådfråga auktoriserad återförsäljare eller specialist för att reparera, installera, avlägsna och återinstallera enheten. Felaktig installation och hantering orsakar läckage, elstöt eller eldsvåda.
Installera inte enheten i en potentiellt explosiv eller lättantändlig miljö. Underlåtenhet i detta kan resultera i skada till följd av eldsvåda.
För inte in dina fi ngrar eller andra föremål i inomhus- eller utomhusenheten, eftersom roterande delar kan orsaka personskada.
Rör inte utomhusenheten under blixtoväder, då det kan orsaka elstöt.
Försök inte reparera enheten på egen hand. Detta kan i så fall orsaka personskada, om det görs på fel sätt.
Installera inte inomhusenheten utomhus. Den är endast utformad för installation inomhus.
VARNINGVARNING
VARNINGVARNING
/
/
STRÖMFÖRSÖRJNING
Använd inte modifi erad sladd, förgreningssladd, förlängningssladd eller ospecifi cerad sladd för att undvika överhettning och eldsvåda.
Dela inte samma strömuttag med annan utrustning för att undvika överhettning och eldsvåda.
Manövrera inte enheten med våta händer för att undvika elstöt.
Om elkabeln är skadad måste den bytas av tillverkaren eller auktoriserad serviceverkstad eller motsvarande behörig person för att undvika skador.
Denna enhet är utrustad med Jordfelsskydd (RCCB). Du rekommenderas starkt att kontrollera RCCB:ns drift efter installationen och med jämna mellanrum efter service eller underhåll av auktoriserad återförsäljare för att försäkra dig om att den är i gott skick. Annars kan den orsaka elstöt eller eldsvåda, ifall fel uppstår på den.
Du rekommenderas starkt att installera den med Restströmenhet (RCD) på platsen för att förhindra elstöt eller brand.
Det rekommenderas att man har på sig handskar under service och underhåll för att undvika skada.
Utrustningen måste jordas för att förhindra elstötar och brand.
Undvik elstöt genom att stänga av strömförsörjningen då:
- Före rengöring eller service.
- Längre tid utan användning.
- Onormalt starkt blixtoväder. Denna apparat är till för fl era användare. Alla
strömförsörjningskretsar måste vara avstängda innan något av uttagen på inomhusenheten används för att undvika elektrisk stöt, brand eller dödlig skada.
Sluta använda produkten om något onormalt/ fel uppträder och koppla ur strömkontakten eller stäng av med strömväxlaren och brytaren. (Risk för rök/eld/elstöt)
Exempel på vad som är onormalt/fel
• RCCB:n stängs av av sig själv.
• Bränd lukt, onormala störljud eller vibrationsljud kan observeras då enheten är i drift.
• Varmt vatten fortsätter komma från enheten.
Kontakta omedelbart din lokala återförsäljare för underhåll/reparation.
FÖRSIKTIGHETFÖRSIKTIGHET
INOMHUS- OCH UTOMHUSENHETINOMHUS- OCH UTOMHUSENHET
Tvätta inte inomhusenheten med vatten, bensen, thinner eller skurpulver.
Installera inte enheten nära någon antändbar utrustning eller i våtrum. Det fi nns i så fall risk för elstöt eller eldsvåda.
Rör inte utgående varmvattenrör vid inomhusenheten under användning.
Ställ ingenting ovanpå eller under enheten. Sitt inte och ställ dig inte på enheten,
eftersom du då kan trilla och skada dig.
Rör inte den vassa aluminiumfl änsen, eftersom vassa delar kan orsaka personskada.
Se till så att dräneringsslangen är korrekt ansluten. Annars kan läckage uppstå.
Kontrollera installationskonsollerna med jämna mellanrum för att vara säker på att inga skador uppstått. Efter längre användningsperioder, kan installationskonsollernas styrka ha försvagats.
KONTROLLPANEL
Låt inte kontrollpanelen bli våt. Det fi nns i så fall risk för elstöt eller eldsvåda.
Tryck inte på knapparna på kontrollpanelen med hårda, spetsiga föremål. Det kan i så fall orsaka skada på enheten.
Tvätta inte kontrollpanelen med vatten, bensen, thinner eller skurningspulver.
Utför inte kontroll eller service av kontrollpanelen själv. Var god rådfråga auktoriserad återförsäljare. Detta kan annars orsaka personskada, om det görs på fel sätt.
Inomhusdel
Dusch
Strömförsörjning
Utomhusdelen
SVENSKA
Panel
Kontrollpanel
Golvuppvärmning
Vattentankenhet
11
PRODUKTÖVERSIKT PRODUKTÖVERSIKT
Luft/Vatten Värmepump Luft/Vatten Värmepump InomhusdelInomhusdel
Vattentrycksmätare Vattentrycksmätare
WATER OUTLET OUTDOOR
HEAT
CC
SETTING STATUS
C
PUMPDW
WATER INLET ERROR
/ ON
OFF
0.2
0.30.1
0.40
MPa
KontrollpanelKontrollpanel
• Tryck inte och slå inte på
0.2
0.30.1
0.40
MPa
glaslocket med hårda, spetsiga föremål. Detta kan skada enheten.
• Se till så att vattentrycket är mellan 0,05 till 0,2 MPa (0,1 MPa = 1 bar).
• Ifall vattentrycket är utanför området ovan, var god rådfråga auktoriserad återförsäljare.
Öppna locket för att använda knapparna
OOR
OUTD
ER OUTLET
WAT
ING
C
SETT
TUS
STA
T
C
HEA
PUMPDW
C
OR
ERR
ET
ER INL
ON
/
WAT
OFF
12 13
WATER OUTLET OUTDOOR
11
HEAT
WATER INLET ERROR
1
2
SETTING
3
OFF
SET
SELECT
CANCEL
14
10
CC
SETTING
CHECK
STATUS
STATUS PUMPDW
SEARCH
PUMPDW
C
/
ON
ERROR RESET
9 8
7
5
6
4
Knappen OFF/ON
1
Driftlampa
2
Lägesknappar
3
Knappen Felåterställning
4
Knappar för kontroll av systemstatus
5
Utpumpningsknapp
6
Display för Systemfel
7
12
Utpumpningsindikator
8
Systemstatusindikator
9
Lägesindikator
10
Uppvärmningsindikator
11
Display för Utgående vattentemperatur
12
Display för Inkommande vattentemperatur
13
Display för Utetemperaturen
14
GRUNDLÄGGANDE ANVÄNDNING GRUNDLÄGGANDE ANVÄNDNING
Användning Start / StoppAnvändning Start / Stopp
• Enheten startar om du trycker på
WATER INLET ERROR
OFF
SETTING
/
ON
STAT US
Användningsdetaljer (Ursprungsinställning)Användningsdetaljer (Ursprungsinställning)
• Användning med ursprungsinställningarna sker enligt följande:
--Då Utetemperaturen (Out Lo) är lägre än 0°C, är den inställda utgående vattentemperaturen (H2O Lo) 50°C. Då Utetemperaturen (Out Hi) är högre än 15°C, är den inställda utgående vattentemperaturen (H2O Hi) 32°C.
• Inom det specifi cerade temperaturområdet för utetemperaturen (Out Lo och Out Hi), justeras utgående vattentemperatur automatiskt av systemet inom det specifi cerade området (H2O Lo och H2O Hi).
• Lägre temperatur i utomhusomgivningen resulterar i högre utgående vattentemperatur och vice versa.
• Då enheten är på (ON), är driftlampan tänd och den faktiska temperaturen för utgående vattentemperatur, inkommande vattentemperatur och utetemperaturen visas på kontrollpaneldisplayen.
/
ON
• Tryck på
OFF
igen för att stoppa driften.
OFF
SVENSKA
/
ON
.
Valfria InställningarValfria Inställningar
ERROR RESET
PUMPDW
Felkodsåterställning
• Kan inte användas under normal användning.
“Pumpdown”
• Kan inte användas under normal användning.
• Om
PUMPDW
trycks in av misstag, tryck på
OFF
/
ON
för att stoppa “Pumpdown”.
13
AVANCERAD ANVÄNDNING AVANCERAD ANVÄNDNING
CANCEL
RekommendationRekommendation
• Vi rekommenderar att en auktoriserad återförsäljare ändrar vattentemperaturområdet. Temperaturområdet för utgående vattentemperatur och utetemperaturen kan ställas in på kontrollpanelen.
Utför stegen nedan för att ställa in det önskade temperaturområdet.
SETTING
SET
CHECK
STATUS
1,5
2,4
STEG 1: Tryck in
STEG 2: Tryck på
SET
i 5 sekunder för att gå till läget SETTING. “SETTING”-indikatorn är på (ON).
eller för att välja en parameter.
SELECT
CANCEL
H2O Lo: Inställd utgående vattentemperatur vid låg inställd utetemperatur
H2O Hi: Inställd utgående vattentemperatur vid hög inställd utetemperatur
Out Lo: Låg inställd utetemperatur
Out Hi: Hög inställd utetemperatur
Obs: Var god se till att Hög inställd utetemperatur (Out Hi) alltid är högre än Låg inställd utetemperatur (Out Lo).
STEG 3:
Efter att du valt önskad parameter, tryck på parameter är vald.
STEG 4: Tryck på
STEG 5: Tryck på
eller för att ställa in den önskade temperaturen.
SET
igen för att bekräfta inställningen.
• Repetera steg 2 till 5 för att ställa in andra parametrar.
SEARCH
ERROR RESET
HEAT
HEAT
HEAT
HEAT
SELECT
för att gå till parametern. “ ” -indikatorn blinkar då en
PUMPDW
C
SETTING STATUS PUMPDW
C
SETTING STATUS PUMPDW
C
SETTING STATUS PUMPDW
C
SETTING STATUS PUMPDW
3
Valområde: 25°C ~ 55°C
Valområde: 25°C ~ 55°C
Valområde:
-15°C ~ 15°C
Valområde:
-15°C ~ 15°C
• Tryck på
eller vänta i 30 sekunder för att gå ur läget SETTING.
• Inställningstemperaturen kommer att lagras i systemet efter att den bekräftats.
• Läget “SETTING” kan inte aktiveras då “PUMPDW” -och “STATUS” -indikatorn är på (ON).
14
Loading...
+ 30 hidden pages