PANASONIC WHUD24BE51, WHUD30BE51, WHSD30BE51, WHSD24BE51 User Manual [da, en, no, fi, sv]

0 (0)

Operating Instructions

Air-to-Water Heatpump

Model No.

 

Indoor Unit

Outdoor Unit

WH-SD24BE5-1 WH-UD24BE5-1

WH-SD30BE5-1 WH-UD30BE5-1

ENGLISH

2

~ 9

Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

 

 

Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and

 

 

precisely following the installation instructions given.

 

 

SVENSKA

10

~ 17

Innan du använder enheten, läs noga igenom denna bruksanvisning och spara den för framtida bruk.

 

 

Innan du använder enheten, se till att installationen har utförts noggrant och korrekt av auktoriserad återförsäljare som

 

 

följt de givna installationsinstruktionerna.

 

 

NORSK

18

~ 25

Les bruksanvisningen nøye før du bruker denne enheten, og oppbevar den for fremtidig bruk.

 

 

Før du bruker enheten, må du forsikre deg om at autorisert forhandler har utført korrekt og presis installasjon og har

 

 

fulgt installasjonsinstruksjonene som er gitt.

 

 

SUOMI

26

~ 33

Lue nämä käyttöohjeet huolellisesti ennen yksikön käyttämistä ja säilytä ne tulevaisuutta varten.

 

 

Varmista ennen laitteen käyttöä, että asennuksen on suorittanut valtuutettu jälleenmyyjä ja että se on tehty oikein ja

 

 

tarkasti annettuja asennusohjeita noudattaen.

 

 

DANSK

Læs brugsanvisningen grundigt igennem før du benytter anlægget og gem den til fremtidig brug.

Sørg for, at anlægget er installeret korrekt af en autoriseret forhandler i overensstemmelse med de følgende instruktioner, før anlægget tages i brug.

© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010. Unauthorized copying and distribution is a violation of law.

34 ~ 41

F567459

Thank you for purchasing

Panasonic Product

TABLE OF CONTENTS

SAFETY PRECAUTIONS

2~3

PRODUCT OVERVIEW

4

BASIC OPERATION

5

ADVANCE OPERATION

6

CARE & CLEANING

7

TROUBLESHOOTING

8

INFORMATION

9

NOTE :

The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.

OPERATION CONDITION

Water outlet

Indoor

Temperature (°C)

 

HEATING

Max.

55

Min.

25

 

 

 

Ambient

Outdoor

Temperature (°C)

 

HEATING

Max.

35

Min.

-20

 

NOTICE : When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly and outdoor unit might stop for protection control.

2

SAFETY PRECAUTIONSI

Panasonic Air-to-Water Heatpump is a split system consisting

only of an indoor unit and an outdoor unit. This system designed for combination with Panasonic Tank Unit. In case of non-Panasonic Tank Unit is being used with Panasonic Air-to-Water Heatpump System, Panasonic cannot guarantee neither good operation nor reliability of the system.

This manual describes how to operate the Heatpump system between indoor and outdoor units only.

Other operation such as water tank, radiator and underfloor system, please refer to respective manufacturer operation manuals.

To prevent personal injury, injury to others, or property damage, please comply with the following.

Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below:

WARNING This sign warns of death or serious injury.

This sign warns of injury or damage to CAUTION property.

The instructions to be followed are classified by the following symbols:

This symbol denotes an action that is

PROHIBITED.

These symbols denote an actions that is COMPULSORY.

WARNING

INDOOR UNIT AND OUTDOOR UNIT

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Please consult authorized dealer or specialist to repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire.

Do not install the unit in a potentially explosive or flammable atmosphere. Failure to do so could result in fire.

Do not insert your fingers or other objects into the indoor or outdoor unit, rotating parts may cause injury.

Do not touch the outdoor unit during lightning, it may cause electric shock.

Do not attempt to repair the unit by yourself. Otherwise, it may cause injury if it is mishandling.

Do not install the indoor unit at outdoor. This is designed for indoor installation only.

WARNING

POWER SUPPLY

Do not use modified cord,

joint cord, extension cord or unspecified cord to prevent overheating and fire.

Do not share the same power outlet with other equipment to prevent overheating and fire.

Do not operate with wet hands to prevent electric shock.

If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly

qualified persons in order to avoid a hazard.

This unit is equipped with Residue Current Circuit Breaker (RCCB). It is strongly recommended to check the operation of the RCCB after installation and periodically after servicing or maintenance by authorized dealer to ensure it is in good working order. Otherwise, it may cause electrical shock or fire in case of malfunction.

It is strongly recommended to install Residual Current Device (RCD) on-site to prevent electric shock or fire.

It is recommended to wear gloves during servicing or maintenance in order to avoid hazard.

This equipment must be earthed to prevent electrical shock or fire.

Prevent electric shock by switching off the power supply when:

- Before cleaning or servicing.

-Extended non-use.

-Abnormally strong lightning activity.

This appliance is for multiple uses. All power supply circuits must be turn off before access to any of the terminals in the indoor unit, to avoid electrical shock, burn or fatal injury.

 

Stop using the product when any abnormality/

 

failure occurs and disconnect the power plug

 

or turn off the power switch and breaker.

 

(Risk of smoke/fire/electric shock)

Examples of

• The RCCB switches off by itself.

• Burning smell, abnormal noise or vibration

abnormality/

sound is observed when the unit is in use.

failure

• Hot water keeps on coming off the unit.

 

 

Contact immediately your local dealer for

 

maintenance/repair.

CAUTION

INDOOR UNIT AND OUTDOOR UNIT

Do not wash the indoor unit with water, benzene, thinner or scouring powder.

Do not install the unit close to any combustible equipment or at bathroom. Otherwise, it may cause electric shock or fire.

Do not touch the water discharge pipe at the indoor unit during operation.

Do not place anything on top or beneath of the unit.

Do not sit or step on the unit, you may fall down accidentally.

Do not touch the sharp aluminium fin, sharp parts may cause injury.

Ensure drainage pipe is connected properly. Otherwise, leakage may occur.

Check the installation rack periodically to make sure that it is not damaged. After long periods of use, the strength of the installation rack may have deteriorated.

CONTROL PANEL

Do not let the control panel get wet. Otherwise, it may cause electric shock or fire.

Do not press the buttons on the control panel with hard, pointed objects. Otherwise, it may damage the unit.

Do not wash the control panel with water, benzene, thinner or scouring powder.

Do not inspect or service the control panel by yourself. Please consult authorized dealer. Otherwise, it may cause injury if mishandling.

Shower

Panel

Indoor Unit

 

Power Supply

Outdoor Unit

 

Floor Heating

Control Panel

Water Tank Unit

ENGLISH

3

PRODUCT OVERVIEW

Air-to-Water Heatpump

Indoor Unit

Water Pressure Gauge

 

 

• Do not press or hit the glass

 

 

cover with hard, pointed

 

0.2

objects. This may damage the

0.1

0.3

unit.

 

0

0.4

• Ensure that the water

 

MPa

pressure is between 0.05 to

 

 

0.2 MPa (0.1 MPa = 1 bar).

 

 

• In case the water pressure is

 

 

out of the above range, please

 

 

consult authorized dealer.

Control Panel

 

 

 

 

 

 

 

12

13

14

 

 

 

 

 

 

 

 

11

WATER OUTLET

OUTDOOR

 

10

Open the cover to

HEAT

 

 

 

 

 

C

 

C

 

use the buttons

 

 

 

 

 

 

 

 

SETTING

9

 

 

 

 

 

 

 

 

C

 

STATUS

 

 

 

 

 

 

 

 

 

PUMPDW

8

 

 

 

OUTD

OOR

 

1

WATER INLET

ERROR

 

 

ER OUTLET

 

 

 

WAT

 

C

SETTING

 

OFF / ON

 

 

 

 

 

 

HEAT

 

C

 

 

STATUS

 

 

 

 

 

PUMPDW

 

 

 

 

C

ERROR

 

 

 

 

 

7

WATER

INLET

 

 

 

 

 

 

 

 

OFF / ON

 

 

 

2

 

 

 

STATUS

 

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

SET

CHECK

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT

 

SEARCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

CANCEL

ERROR

PUMPDW

 

 

 

 

 

 

 

 

RESET

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

1

OFF/ON Button

8

System Pumpdown Mode Indicator

2

Operation LED

9

System Status Check Mode Indicator

3

System Setting Mode Buttons

10

System Setting Mode Indicator

4

Error Reset Button

11

Heating Operation Indicator

5

System Status Check Mode Buttons

12

Water Outlet Temperature Display

6

System Pumpdown Mode Button

13

Water Inlet Temperature Display

7

System Error Display

14

Outdoor Ambient Temperature Display

4

BASIC OPERATION

ENGLISH

Operation Start / Stop

 

 

The unit starts by pressing OFF / ON

.

WATER INLET

ERROR

• When unit is ON, operation LED is lit and the actual

OFF / ON

 

 

 

 

temperature for water outlet, water inlet and outdoor

SETTING

STATUS

 

ambient are shown on the control panel display.

 

 

 

 

SET

CHECK

Press OFF / ON

again to stop the operation.

 

 

Operation details (Default setting)

Operation takes place under default settings as follows:

-When Outdoor ambient temperature (Out Lo) is less than 0°C, water outlet set temperature (H2O Lo) is 50°C.

-When Outdoor ambient temperature (Out Hi) is more than 15°C, water outlet set temperature (H2O Hi) is 32°C.

In between the specified outdoor ambient temperature range (Out Lo and Out Hi), the system will automatically adjust the water outlet temperature between specified range (H2O Lo and H2O Hi).

Lower outdoor ambient temperature will result in higher water outlet temperature and vice versa.

Optional Settings

ERROR

Error code reset

 

RESET

• Not usable during normal operation.

 

 

 

PUMPDW

System Pump Down

 

• Not usable during normal operation.

 

 

 

 

• If accidentally pressed the PUMPDW, press OFF / ON

to stop the pump down operation.

5

PANASONIC WHUD24BE51, WHUD30BE51, WHSD30BE51, WHSD24BE51 User Manual

ADVANCE OPERATION

Recommendation

It is strongly recommended to have the authorized dealer to change the water temperature range. The temperature range for water outlet temperature and outdoor ambient temperature could be set by control panel.

Perform the steps below to set preferred temperature range.

1 , 5

 

 

SETTING

STATUS

 

 

SET

CHECK

2 , 4

 

SELECT

SEARCH

 

 

 

ERROR

 

 

 

CANCEL RESET

PUMPDW

3

STEP 1: Press SET for 5 seconds to enter SETTING mode. “SETTING” indicator is ON.

STEP 2: Pressorto choose a parameter.

H2O Lo: Water outlet set

HEAT

Selection range:

temperature at low outdoor

 

C

25°C ~ 55°C

ambient set temperature

 

SETTING

 

 

STATUS

 

 

PUMPDW

H2O Hi: Water outlet set

HEAT

Selection range:

temperature at high outdoor

 

C

25°C ~ 55°C

ambient set temperature

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Lo: Low outdoor

HEAT

Selection range:

ambient set temperature

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Hi: High outdoor

HEAT

Selection range:

ambient set temperature

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Note: Please make sure High outdoor ambient set temperature (Out Hi) is always higher than Low outdoor ambient set temperature (Out Lo).

STEP 3: After selecting the desired parameter, press

SELECT

” indicator will blink when a

to enter the parameter. “

parameter is selected.

 

 

STEP 4: Pressorto set the desired temperature.

STEP 5: Press SET again to confirm the setting.

Repeat steps 2 to 5 to set other parameters.

Press CANCEL or wait 30 seconds to exit SETTING mode.

The setting temperature will be stored in the system once confirm.

“SETTING” mode cannot be activated when the “PUMPDW” and “STATUS” indicator is ON.

6

CARE & CLEANING

• Switch off the power supply before cleaning.

CAUTION

Indoor Unit & Control Panel

Do not splash water directly.

Wipe the unit gently with a soft, dry cloth.

External Filter

Please clean the external filter at least once a year. Fail to do so might cause filter clogged, consequent system breakdown. Please consult authorized dealer.

Outdoor Unit

Do not obstruct the air inlet and air outlet vents, it may cause low performance or breakdown. Please remove obstacles to assure the ventilation.

During winter, please clean and remove the snow near outdoor unit so that the snow does no cover the air inlet and air outlet vents.

Inspection

In order to ensure optimal performance of the unit, seasonal inspections on the unit, external filter and field wiring have to be carried out at regular intervals. This maintenance should be carried out by authorized dealer.

Clear any obstruction at the air inlet and air outlet vents of outdoor unit.

For Extended Non-Use

• Turn off the power supply.

Perform the steps below to check system status

 

 

 

1

SETTING

 

STATUS

 

SET

 

CHECK

 

SELECT

 

SEARCH

2

 

 

 

CANCEL

ERROR

PUMPDW

 

RESET

 

STEP 1:

Press

CHECK for 5 seconds to enter STATUS mode.

STEP 2:

Press

or

to check the Water Inlet Temperature, Tank Temperature, Compressor Running

Frequency or Error History.

Press CANCEL or wait 30 seconds to exit STATUS mode.

Once STATUS mode is entered, “STATUS” indicator is ON.

STATUS mode cannot be activated when the “SETTING” indicator is ON.

ENGLISH

7

 

 

 

 

TROUBLESHOOTING

 

 

 

 

The following symptoms do not indicate malfunction.

 

 

 

 

 

 

 

 

 

Symptom

Cause

 

 

 

 

 

 

Water flowing sound during operation.

• Refrigerant flow inside the unit.

 

 

Operation is delayed a few minutes after

• The delay is a protection to the unit’s compressor.

 

restart.

 

 

 

Outdoor unit emits water/steam.

• Condensation or evaporation occurs on pipes.

 

Outdoor unit emits steam during heating

• This is due to defrost operation happens at the heat exchanger.

 

mode.

 

 

Outdoor unit does not operate.

When the outdoor temperature is out of the operation condition range, the heatpump system enter protection control.

Air-to-Water Heatpump system operation will turn off.

System difficult to heat-up.

If indoor unit water inlet temperature is lower than 20°C. Please set the heater of tank more than 20°C.

When heating is operated by indoor unit together with floor heating or panel heater simultaneously, there may be case where warm water temperature is getting lower and cause floor heating or panel heater heat-up is weaken.

When outdoor air temperature is low, it may be difficult to get warm.

Is the snow pile blocking the discharge outlet or intake inlet of outdoor unit.

When water outlet set temperature is low, it may be difficult to get warm.

System cannot get warm instantly.

Due to the nature of the heatpump system, it may take some time to heat-up the water if the unit is operated from cold-start.

Operation starts after power resumes.

• Auto restart is in function and operates under.

Check the following before calling for servicing.

Symptom

Check

 

 

 

Heating operation is not working efficiently.

Set the temperature correctly.

 

Is the panel heater valve closed.

 

Clear any obstruction at the air inlet and air outlet vents of outdoor unit.

Noisy during operation.

Check if the unit has been installed at an incline or the cover is not

 

 

closed properly.

The unit does not work.

Operation LED is no lit or control panel display is blank.

Check if the circuit breaker is tripped.

Is the power supply off or power failure.

The operation LED blinks and error code appear on control panel display.

WATER INLET

ERROR

• Turn the unit off and reveal the error code to authorized dealer.

8

INFORMATION

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions:

Abnormal noise during operation.

Water/foreign particles have entered the control panel.

Water leaks from Indoor unit.

Circuit breaker switches off frequently.

Power cord becomes unnaturally warm.

Switches or buttons are not functioning properly.

Information for Users on Collection and Disposal of Old Equipment

These symbols on the products, packaging, and/or accompanying documents mean that used electrical and

electronic products should not be mixed with general household waste.

For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.

By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling.

For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items.

Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

For business users in the European Union

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.

[Information on Disposal in other Countries outside the European Union]

These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.

ENGLISH

9

Tack för ditt inköp av

Panasonic -produkt

INNEHÅLLSFÖRTECKNING

SÄKERHETSFÖRESKRIFTER

10~11

PRODUKTÖVERSIKT

12

GRUNDLÄGGANDE ANVÄNDNING 13

AVANCERAD ANVÄNDNING

14

UNDERHÅLL & RENGÖRING

15

PROBLEMLÖSNING

16

INFORMATION

17

OBS :

Bilderna i denna skötselanvisning är endast illustrativa och kan därför skilja sig från den faktiska modellen. Förändringar kan göras utan föregående meddelande angående framtida förbättringar.

TILLÅTNA

DRIFTSFÖRHÅLLANDEN

Vattenutloppstemperatur

Inomhus

 

(°C)

 

 

VÄRME

 

Max.

55

 

Min.

25

 

 

 

 

Omgivningstemperatur

Utomhus

 

(°C)

 

 

VÄRME

 

Max.

35

 

Min.

-20

 

 

MÄRK : Då utomhustemperaturen är utanför temperaturområdet ovan, sjunker uppvärmningskapaciteten avsevärt och utomhusenheten kan stoppa för skyddskontroll.

10

SÄKERHETSFÖRESKRIFTERI

Panasonics Luft-till-Vatten-Värmepump är ett split-system som består av endast en inomhusenhet och en utomhusenhet. Det här systemet är tillverkat för att användas med Panasonics ackumulatortank.

Om du använder Panasonics Luft-till-Vatten-Värmepump med en ackumulatortank från en annan tillverkare än Panasonic, kan Panasonic varken garantera god prestanda eller tillförlitlig drift.

I denna manual beskrivs hur du använder värmepumpsystemet mellan inomhusoch utomhusenheterna enbart.

För annan användning av t.ex. vattentank, värmeelement och golvvärmesystem, se bruksanvisningen från respektive tillverkare.

För att undvika skada på dig själv, skada på andra, eller skada på egendom, var god iaktta följande.

Felaktig användning orsakad av att skötselanvisningen inte följts kan leda till skador, nedan klassas deras allvar:

VARNING

Denna symbol varnar för dödsfara eller

allvarliga skador.

 

Denna symbol varnar för personskada eller FÖRSIKTIGHET skada på egendom.

Instruktioner klassificeras med följande symboler:

Denna symbol betecknar en handling som är FÖRBJUDEN.

Denna symbol betecknar ett handhavande som MÅSTE UTFÖRAS.

VARNING

INOMHUSOCH UTOMHUSENHET

Denna apparat är inte avsedd att användas av personer (inklusive barn) med reducerad fysiska, sensoriska eller mentala färdigheter, eller brist på erfarenhet och kunskap, ifall de inte övervakats eller instruerats om användandet av apparaten av en person som ansvarar för deras säkerhet. Barn bör övervakas för att se till att de inte leker med apparaten.

Var god rådfråga auktoriserad återförsäljare eller specialist för att reparera, installera, avlägsna och återinstallera enheten. Felaktig installation och hantering orsakar läckage, elstöt eller eldsvåda.

Installera inte enheten i en potentiellt explosiv eller lättantändlig miljö. Underlåtenhet i detta kan resultera i skada till följd av eldsvåda.

För inte in dina fingrar eller andra föremål i inomhuseller utomhusenheten, eftersom roterande delar kan orsaka personskada.

Rör inte utomhusenheten under blixtoväder, då det kan orsaka elstöt.

Försök inte reparera enheten på egen hand. Detta kan i så fall orsaka personskada, om det görs på fel sätt.

Installera inte inomhusenheten utomhus. Den är endast utformad för installation inomhus.

VARNING

STRÖMFÖRSÖRJNING

Använd inte modifierad sladd,

förgreningssladd, förlängningssladd eller ospecificerad sladd för att undvika

överhettning och eldsvåda.

Dela inte samma strömuttag med annan utrustning för att undvika överhettning och eldsvåda.

Manövrera inte enheten med våta händer för att undvika elstöt.

Om elkabeln är skadad måste den bytas av tillverkaren eller auktoriserad serviceverkstad eller motsvarande behörig person för att undvika skador.

Denna enhet är utrustad med Jordfelsskydd (RCCB). Du rekommenderas starkt att kontrollera RCCB:ns drift efter installationen och med jämna mellanrum efter service eller underhåll av auktoriserad återförsäljare för att försäkra dig om

att den är i gott skick. Annars kan den orsaka elstöt eller eldsvåda, ifall fel uppstår på den.

Du rekommenderas starkt att installera den med Restströmenhet (RCD) på platsen för att förhindra elstöt eller brand.

Det rekommenderas att man har på sig handskar under service och underhåll för att undvika skada.

Utrustningen måste jordas för att förhindra elstötar och brand.

Undvik elstöt genom att stänga av strömförsörjningen då:

- Före rengöring eller service.

-Längre tid utan användning.

-Onormalt starkt blixtoväder.

Denna apparat är till för flera användare. Alla strömförsörjningskretsar måste vara avstängda innan något av uttagen på inomhusenheten används för att undvika elektrisk stöt, brand eller dödlig skada.

 

Sluta använda produkten om något onormalt/

 

fel uppträder och koppla ur strömkontakten

 

eller stäng av med strömväxlaren och

 

brytaren. (Risk för rök/eld/elstöt)

Exempel på

• RCCB:n stängs av av sig själv.

• Bränd lukt, onormala störljud eller vibrationsljud

vad som är

kan observeras då enheten är i drift.

onormalt/fel

• Varmt vatten fortsätter komma från enheten.

 

Kontakta omedelbart din lokala återförsäljare för underhåll/reparation.

FÖRSIKTIGHET

INOMHUSOCH UTOMHUSENHET

Tvätta inte inomhusenheten med vatten, bensen, thinner eller skurpulver.

Installera inte enheten nära någon antändbar utrustning eller i våtrum. Det finns i så fall risk för elstöt eller eldsvåda.

Rör inte utgående varmvattenrör vid inomhusenheten under användning.

Ställ ingenting ovanpå eller under enheten.

Sitt inte och ställ dig inte på enheten, eftersom du då kan trilla och skada dig.

Rör inte den vassa aluminiumflänsen, eftersom vassa delar kan orsaka personskada.

Se till så att dräneringsslangen är korrekt ansluten. Annars kan läckage uppstå.

Kontrollera installationskonsollerna med jämna mellanrum för att vara säker på att inga skador uppstått. Efter längre användningsperioder, kan installationskonsollernas styrka ha försvagats.

KONTROLLPANEL

Låt inte kontrollpanelen bli våt. Det finns i så fall risk för elstöt eller eldsvåda.

Tryck inte på knapparna på kontrollpanelen med hårda, spetsiga föremål. Det kan i så fall orsaka skada på enheten.

Tvätta inte kontrollpanelen med vatten, bensen, thinner eller skurningspulver.

Utför inte kontroll eller service av kontrollpanelen själv. Var god rådfråga auktoriserad återförsäljare. Detta kan annars orsaka personskada, om det görs på fel sätt.

Dusch

Panel

Inomhusdel

 

Strömförsörjning

Utomhusdelen

 

SVENSKA

Golvuppvärmning

Kontrollpanel

Vattentankenhet

11

PRODUKTÖVERSIKT

Luft/Vatten Värmepump

Inomhusdel

Vattentrycksmätare

 

 

• Tryck inte och slå inte på

 

 

glaslocket med hårda,

 

0.2

spetsiga föremål. Detta kan

0.1

0.3

skada enheten.

0

0.4

• Se till så att vattentrycket är

 

MPa

mellan 0,05 till 0,2 MPa

 

 

(0,1 MPa = 1 bar).

 

 

• Ifall vattentrycket är utanför

 

 

området ovan, var god

 

 

rådfråga auktoriserad

 

 

återförsäljare.

Kontrollpanel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

13

14

 

 

 

 

 

 

 

 

11

WATER OUTLET

OUTDOOR

 

10

Öppna locket för att

HEAT

 

 

 

 

 

C

 

C

 

använda knapparna

 

 

 

 

 

 

 

 

SETTING

9

 

 

 

 

 

 

 

 

C

 

STATUS

 

 

 

 

 

 

 

 

 

PUMPDW

8

 

 

 

OUTD

OOR

 

1

WATER INLET

ERROR

 

 

ER OUTLET

 

 

 

WAT

 

C

SETTING

 

OFF / ON

 

 

 

 

 

 

HEAT

 

C

 

 

STATUS

 

 

 

 

 

PUMPDW

 

 

 

 

C

ERROR

 

 

 

 

 

7

WATER

INLET

 

 

 

 

 

 

 

 

OFF / ON

 

 

 

2

 

 

 

STATUS

 

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

SET

CHECK

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT

 

SEARCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

CANCEL

ERROR

PUMPDW

 

 

 

 

 

 

 

 

RESET

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

1

Knappen OFF/ON

8

Utpumpningsindikator

2

Driftlampa

9

Systemstatusindikator

3

Lägesknappar

10

Lägesindikator

4

Knappen Felåterställning

11

Uppvärmningsindikator

5

Knappar för kontroll av systemstatus

12

Display för Utgående vattentemperatur

6

Utpumpningsknapp

13

Display för Inkommande vattentemperatur

7

Display för Systemfel

14

Display för Utetemperaturen

12

GRUNDLÄGGANDE ANVÄNDNING

SVENSKA

Användning Start / Stopp

 

 

• Enheten startar om du trycker på OFF / ON

.

WATER INLET

ERROR

• Då enheten är på (ON), är driftlampan tänd och den

OFF / ON

 

faktiska temperaturen för utgående vattentemperatur,

 

 

inkommande vattentemperatur och utetemperaturen

SETTING

STATUS

visas på kontrollpaneldisplayen.

 

SET

CHECK

• Tryck på OFF / ON

 

 

 

 

igen för att stoppa driften.

Användningsdetaljer (Ursprungsinställning)

Användning med ursprungsinställningarna sker enligt följande:

-Då Utetemperaturen (Out Lo) är lägre än 0°C, är den inställda utgående vattentemperaturen (H2O Lo) 50°C.

-Då Utetemperaturen (Out Hi) är högre än 15°C, är den inställda utgående vattentemperaturen (H2O Hi) 32°C.

Inom det specificerade temperaturområdet för utetemperaturen (Out Lo och Out Hi), justeras utgående vattentemperatur automatiskt av systemet inom det specificerade området (H2O Lo och H2O Hi).

Lägre temperatur i utomhusomgivningen resulterar i högre utgående vattentemperatur och vice versa.

Valfria Inställningar

ERROR

Felkodsåterställning

RESET

• Kan inte användas under normal användning.

 

“Pumpdown”

PUMPDW

• Kan inte användas under normal användning.

 

 

 

 

• Om PUMPDW trycks in av misstag, tryck på OFF / ON

för att stoppa “Pumpdown”.

13

AVANCERAD ANVÄNDNING

Rekommendation

Vi rekommenderar att en auktoriserad återförsäljare ändrar vattentemperaturområdet. Temperaturområdet för utgående vattentemperatur och utetemperaturen kan ställas in på kontrollpanelen.

Utför stegen nedan för att ställa in det önskade temperaturområdet.

1 , 5

 

 

 

SETTING

STATUS

 

 

 

SET

CHECK

2

, 4

 

SELECT

SEARCH

 

 

 

ERROR

 

 

 

 

CANCEL RESET

PUMPDW

 

 

 

 

3

STEG 1:

Tryck in SET

i 5 sekunder för att gå till läget SETTING. “SETTING”-indikatorn är på (ON).

STEG 2:

Tryck på

eller

för att välja en parameter.

 

H2O Lo: Inställd utgående

HEAT

Valområde:

vattentemperatur vid låg inställd

 

C

25°C ~ 55°C

utetemperatur

 

SETTING

 

 

STATUS

 

 

PUMPDW

H2O Hi: Inställd utgående

HEAT

Valområde:

vattentemperatur vid hög inställd

 

C

25°C ~ 55°C

utetemperatur

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Lo: Låg inställd

HEAT

Valområde:

utetemperatur

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Hi: Hög inställd

HEAT

Valområde:

utetemperatur

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Obs: Var god se till att Hög inställd utetemperatur (Out Hi) alltid är högre än Låg inställd utetemperatur (Out Lo).

STEG 3: Efter att du valt önskad parameter, tryck på

SELECT

” -indikatorn blinkar då en

för att gå till parametern. “

parameter är vald.

 

 

STEG 4: Tryck påellerför att ställa in den önskade temperaturen.

STEG 5: Tryck på SET igen för att bekräfta inställningen.

Repetera steg 2 till 5 för att ställa in andra parametrar.

Tryck på CANCEL eller vänta i 30 sekunder för att gå ur läget SETTING.

Inställningstemperaturen kommer att lagras i systemet efter att den bekräftats.

Läget “SETTING” kan inte aktiveras då “PUMPDW” -och “STATUS” -indikatorn är på (ON).