CHARACTERISTICS AND REQUESTS
ABOUT YOUR GAS HEAT PUMP AIR CONDITIONER
The gas heat pump air conditioner (GHP) uses gas as the fuel to drive the compressor.
As it uses gas engine, there are various characteristics.
• As the unit does not easily frost, defrosting operations are infrequent even on very cold days, allowing the unit to
provide stable and continuous heating.
• As the electric power consumption is about 1 kW, this leads to be less received power equipment.
However, as with a car engine, periodical inspections by a specialist are for efcient use needed for a comfortable
operation. Make sure you have these periodical inspections.
ENSURE YOU SIGN UP FOR A REGULAR CHECK UP CONTRACT
In order to have a comfortable operation of GHP for a long period, periodical inspections are necessary.
Conduct yearly inspections supported by a specialist.
What will happen if you do not have periodical inspections.
1. The engine oil will deteriorate, causing a malfunction.
2. The air cleaner element will be clog up, causing carbon monoxide and occasional reduction of performance.
REQUESTS
Once signed up for a periodical inspection, a specialist will call on depending on the length of time the unit has been
in use. After a xed period of in use hours, the remote controller will display “Oil Inspection”.
At this time we would appreciate you contacting your dealer or service center for a check up.
For details refer to page 4.
CHANGING ENGINE OIL
Periodically change engine oil and oil lter.
If you forget to change engine oil or use a non-specied oil, it may have a bad effect on the engine
and be the cause of trouble.
* Engine oil (Genuine oil)
CAUTION
• Filling in too much oil will have a bad effect on the engine.
• Consult with your service center or dealer when changing the oil.
NOTICE
• The English text is the original instructions. Other languages are translation of the original
instructions.
EN - 2
PERIODICAL INSPECTION
In order to have a comfortable operation of GHP for a long period, periodical inspections are necessary. When you
purchase your GHP, sign up for Panasonic’s periodical inspections contract system.
When you sign up for a periodical inspection, specialist will call on you.
For more details about the inspection contract, ask your dealer or consult with one of our service centers.
TEST OPERATION
Inspection items
(Test operation)
• Check the installation work
• Inspect the electricity wiring
• Inspect the equipment itself
• Check the engine system
• Check safety protection devices
• Operation data collection
• Gas leakage check
EN
Contact your installer for repairs if something is found to be amiss during
the test operation.
EN - 3
PERIODICAL INSPECTION
GUARANTEE PERIOD
The guarantee period is ONE year after the date of a successful test operation and the product delivery.
However, the engine itself and periodical replaced parts are guaranteed for ONE year after a successful test
operation and the product delivery or 2000 hours in operation whichever comes earlier.
PERIODICAL INSPECTIONS AFTER YOUR GUARANTEE EXPIRES
The number of inspections depends on the operating hours for a period of one year.
The table below shows a case of 2000 hours of use in one year. If you have signed up for a periodical inspection,
a GHP specialist will call on you and carry out the services mentioned below, exchange parts and make necessary
adjustment.
PERIODICAL INSPECTIONS ITEMS
Inspection timingLeave the timing of the visit upto a specialist.
Inspection Items• Checking the level of the coolant uid -replenish when necessary:
every 10,000 hours or every ve years.
• Checking the drain lter antalkali -replenish when necessary:
every 10,000 hours or every ve years.
• Inspecting and adjusting various parts: Depending on the contents of periodical inspection.
Check the engine system
Check safety protection devices
Engine oil inspection and replenishment when necessary
Operation data collection
Gas leakage check
Periodical
Replacement
parts
Replacement IntervalParts name
• Engine oil
• Oil lter
• Air cleaner element
10,000 hours or every
5 years
Note: Changing engine oil is only for engine proper and sub-oil pan. Replenish the oil into oil
tank, located at the upper portion.
Periodical
adjustment
There is a fee for periodical inspections.
Note: Parts change is calculated on the basis of 2000 hours per year over a 10 year period.
If replacement parts other than those listed above should be required an additional fee other than the periodical
inspection contract fee will be charged.
Note: Should dust or dirt collect on the n of heat exchanger of either the indoor unit or outdoor unit this will result in
loss of efciency.
After consulting with your dealer or service center remove the dirt and dust and wash the heat exchanger.
• Engine valve clearance adjustment is done every 10,000 hours or every ve years.
• Compressor belt
• Ignition plug
• Oil absorption mat
• Drain lter packing
EN - 4
SAFETYPRECAUTIONS
SAFETY PRECAUTIONS
Before operating the unit, be sure to read the SAFETY PRECAUTIONS.
Listed below are two types of precautions, one is a WARNING and the other is a CAUTION.
Be sure to obey these instructions for safety sake.
• The expressions have the following meanings.
WARNING
CAUTION
• The meaning of the symbols
“WARNING” or “CAUTION”.
• Keep this manual in an easy to reach place so the operator can easily refer to it.
If the operator should change, be sure to hand over this manual for him to read.
This symbol refers to a hazard or unsafe practice which can result in severe personal injury
or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or
product or property damage.
Refers to something that is
“FORBIDDEN”.
PRECAUTIONS BEFORE USE
WARNING
Do NOT install the equipment yourself.
Ask your dealer or a specialist
to install the equipment. If you
improperly install it by yourself, it
might lead to an electrical shock,
re and water leakage and so
on.
Conrm the kind of gas you use.
If you use the wrong kind of
gas, it might lead to incomplete
combustion and be the cause of
gas poisoning. Conrm the gas
kind.
Refers to advices that should
be followed.
EN
Conrm that the exhaust drain from the
outdoor unit and the drain water from the
indoor unit is not commonly connected.
If these are the common pipes,
then exhaust gas could leak into
the room and be the cause of
poisoning. Conrm the drains
are separate.
In the rare possibility of a leak of
refrigerant.
If the equipment is installed in a
small room, steps must be taken
to ensure the rare possibility that
leakage of the refrigerant does
not exceed a certain limit.
Before installation, consult with
your dealer about this certain
limit. In an emergency when
the refrigerant leaks, it may
cause an accident due to lack of
oxygen in the air.
Conrm that each unit has an exclusive
electric circuit.
If you use other electrical
equipment(s) on the same
circuit, then you may blow a fuse
or cause secondary damage to
equipment. Conrm the electric
circuit.
Be sure to buy Panasonic specied
equipment.
If you buy separate equipment
such as an air cleaner or a
humidier (in case of tting inside
the unit), be sure to buy only
Panasonic specied products. And
ask a specialist dealer to install it.
If you improperly install the
equipment by yourself, it may
lead to an electric shock, re or
water leakage and so forth. Buy
Panasonic specied equipment.
Check with a dealer or professional service provider that the specied
refrigerant is used.
Using a refrigerant other than specied may result in equipment failure, burst
or injury.
EN - 5
SAFETY PRECAUTIONS
CAUTION
Be sure to install the outdoor unit where
there is no volatile or inammable
material.
Ascertain there is no
occurrence, inux or collection
of inammable or volatile gases
in the area surrounding the
place you install your outdoor
unit. If you do not do this, it may
cause a re.
Do not use this appliance
in a potentially explosive
atmosphere.
Check you have an earth leakage circuit
breaker in place.
An earth leakage circuit breaker
is required by law. Failure to
install one may result in electric
shock or re.
Check the condition of grounding work.
Do not connect the ground wire
to any gas pipes, water pipes,
lightening rods or telephone
ground wires. If the ground
wire is faulty, it may result in an
electrical shock.
Water pipe
Some parts are made of plastic and
are no good for earthing.
Gas pipe
There is a danger of ignition and explosion.
The telephone earth, a lightning rod
When struck by lightning, there is a great danger of a
massive power surge.
Danger!
Grounding
wire
Check that you have a rated power
supply and check the capacity of the
circuit breaker.
It could lead to damage to the
equipment or cause a re.
Conrm the power supply and
breaker capacity.
Only use a fuse of the correct capacity.
Using wire and the like instead
of the correct fuse could lead to
an electric shock and re.
PRECAUTIONS DURING USE
Make sure that the exhaust gases from
the outdoor unit do not seep inside.
If exhaust gases get inside
the room, it could cause gas
poisoning.
Do not put your hand or foreign objects
in the outlet or inlet of both indoor and
outdoor units.
A high speed fan is rotating
inside and could cause injury.
Be sure to install the drain pipe of indoor
unit with same gradient to drain out
properly.
A water leakage could cause
damage to your furniture and
other property.
WARNING
Do not operate the equipment with wet
hands.
It could cause an electric shock
or damage the equipment.
Do not block the intake, discharge or the
drain of the outdoor unit.
It may lead to incomplete
combustion and cause a re or
gas poisoning.
EN - 6
SAFETY PRECAUTIONS
WARNING
Do not expose yourself directly to the
warm or cold air for a long period of time.
It could damage your health.
What to do if the refrigerant leaks.
If the refrigerant leaks, then
turn off the air conditioner and
ventilate the room. Then notify
your dealer or service center.
If the leak exceeds a certain
limit, it could cause a lack of
oxygen in the air.
What to do if the outdoor unit leaks fuel gas.
If the outdoor unit leaks fuel gas,
then turn off the air conditioner,
close the main gas valve and
contact your local gas company
or service company or dealer for
repairs. It could cause a re.
If you detect a strange smell (a burning
smell, a gas smell), or a abnormal sound
or unusual vibrations, then turn off your
air conditioner and the electric supply.
If you continue to use the
equipment under abnormal
circumstances, it could lead to
an electric shock, re or cause a
machine breakdown.
Contact your dealer or service
center.
EN
CAUTION
Do NOT open the panel.
Inside the units are revolving
parts, high temperature parts
and high voltage parts and if
you touch them it could result in
injury or an electric shock.
Do NOT touch the exhaust outlet.
It is very hot and could cause a
burn.
DO NOT place combustion apparatus in
the direct line of the air out of indoor unit.
It could cause incomplete
combustion of Combustion
apparatus.
Do NOT remove the fan guard.
The fan revolves at high speed
and could cause injury.
Do NOT spray the units with an
inammable spray.
Do NOT place or use
combustible sprays near or on
the units.
It could lead to ignition.
Ventilate the room every so often when
you use inammable material with the air
conditioner on.
Insufcient ventilation could
cause a lack of oxygen in the air.
EN - 7
SAFETY PRECAUTIONS
CAUTION
Do NOT use the unit for a particular
cooling applications such as food
supplies, animals and plants, precision
machinery or objects of art: things that
Do NOT place animals or plants in the
direct path of the air.
It might badly affect to animals
or plants.
need a special preservation requirement.
It could cause a deterioration in
the quality of food stuffs and so
forth.
Do NOT place containers that hold water on top of the indoor unit.
Do NOT place ower vases or similar things that hold water on top of the
indoor unit.
It could cause damage to the electrical insulation of the indoor unit and electric
shock.
REQUESTS
Do NOT operate the remote
control with a pointed
object.
It could damage
the remote
control.
Make sure to use an air
lter in the indoor unit.
Dust and dirt
could get into the
unit and cause a
breakdown.
Do NOT use the air
conditioner with the doors
or windows left open.
It could cause
frosting around the
discharge portion.
Do NOT block the inlet
or the outlet of both the
indoor and outdoor unit.
It could result in a
loss both of cooling
and heating. It
could also lead
to damage to the
equipment.
Obey the following regarding the power source
installed nearby the unit:
• Do NOT operate the equipment with the at hand power
source.
Your air conditioner is a Multi-type air conditioner.
If you turn off one of the power sources installed near
by the unit, all the units with the same power source will
become inoperable.
• Turn on the power Switch at least 5 hours before
operating the air conditioner.
In order to protect the compressor, the crank case heater
is provided.
Be sure to carry out the following.
power source
At inspection
times or when
you want to use
the air
conditioner turns
the switch ON
at least 5 hours
beforehand.
Leave the switch
ON during the
seasons you use
the equipment.
switch
ON
• During maintenance, turn the power switch OFF.
• During seasons of use do NOT turn the power switch
OFF.
Turn the switch
OFF during the
seasons you
do not use the
equipment.
switch
OFF
EN - 8
SAFETY PRECAUTIONS
Pull off the power plug from a receptacle, or switch off the breaker, or
switch off the power disconnecting mean to isolate the air conditioner
from the main power supply in case of emergency.
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
RELOCATION/REPAIR
For relocation, consult with the dealer.
To relocate an indoor or
outdoor unit, expertise is
required, thus ensure you
consult with your dealer or
the service company.
Flaws in installation may result
in exhaust gas owing into
buildings leading to poisoning,
water leakage, electrication or
re.
WARNING
CAUTION
WARNING
Do not remodel or renovate.
Never remodel or renovate.
Also, for repairs, consult with
your dealer or the service
company.
Incorrectly repair may result in
water leaks, electrication or
re.
EN
When you are nished using the product
When you nishing using the product, ensure there is no risk of it dropping or falling.
For removal, consult with your dealer or the service company.
Important Information Regarding the Refrigerant Used
This product contains uorinated greenhouse gases. Do not vent gases into the atmosphere.
Refrigerant type: R410A
(1)
GWP
value: 2088
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local
dealer for more information.
EN - 9
THINGS YOU SHOULD KNOW
• All about special use.
CAUTION
This air conditioner is for use in dwellings space only.
Do not use for any other purposes.
Do not use the equipment where there are things
which require special preservation such as food
stuffs, animals, precision instruments and works of
art.
• In case of a power failure.
If a power failure occurs during operation, the unit will
stop and remain stopped.
To restart the operation after power is supplied, follow
the start operations again.
• In case of a malfunction
If, during operation, a malfunction should occur due
to lightning, radio waves, power source noise etc.,
then turn off the power source switch.
To re-start the operation, turn on the power switch
and follow the start operations again.
• A gas engine is built in and a periodical check up is
necessary. (Changing the engine oil, etc.)
Sound Pressure Level: 58 dB(A) U-16GE3E5
About the ‘Oil Check’ display on the remote controller
The oil check mark blinks to remote control when the
operating hour of the gas engine becomes prescribed
time. (Right picture) Contact sales companies or the
service agency and do the periodic inspection when
‘Oil check mark’ is displayed.
It causes the breakdown of outdoor unit if it leaves it
as it is.
In order to use the air conditioner correctly, operate under the following conditions.
If you operate the equipment at temperature for a long period of time, the protective components will engage and
the equipment will become inoperable.
Outdoor Temperature
≥ Approx. -10°C, ≤ 43°C
Cooling ModeHeating Mode
Outdoor Temperature
≥ Approx. -20°C, ≤ 21°C
Indoor Temperature
≥ Approx. 18°C, ≤ 32°C
Indoor Temperature
≤ Approx. 26°C
Room Humidity
≤ Approx. 80%
In the rainy season or when the air
humidity is high, using the air conditioner
for a long time may result in frost on the
surface of the equipment and fog may be
discharged from the air discharge.
EN - 10
MARKINGS FOR DIRECTIVE 2014/68/EU (PED)
RATING NAMEPLATE FIGURE
Tabulation of Various date
0035
0063
Gas Hea
A
ir Condition
■ Se ria l No .N um ero d i S erie " No ."
■ Ye ar of Ma nuf ac turi ngAn no di pr odu zion eM M- YY YY
■ Pow er Sou rceA lim ent azi one
■ Ti me D ela y Fu se M ax Size Lu og o d i Ins tal laz ion e20 AT
■ Ma x. E lec tric al In put
■ Ma x. E lec tric al In put
■ Un it P rote ctio n Gra do di Pro tezi oneI P24
OU TD OOR U SE O NLYU TILI ZZ AR E S OLO AL L' E STE RN O
■ Co ol ing Ca pac ityCa pac ita in R aff redd am en to
■ He atin g C ap ac ityCa pa cit a in R is cal dam ent o
■ He at inp ut(H s) (C ool in g)Co nsu mo GA S(R af fre dd am ento )
■ He at inp ut(H s) (H ea tin g)Con sum o G AS (R isc ald am ent o)
■ De sig n P res sur e H ig h Sid e Al ta pres si one
■ De sig n P res sur e Low S ide B as sa pre ss ion e
■ Ap pli an ce Typ eTi po di A ppl ica zio neA (f or o utdo or i ns tall atio n o nl y)
■ Ap pli an ce Ca teg oryC ate go ria d i A pp lic azio neⅡ 2H 3P2H -20 mb ar3P -37 mb ar
Authorized representative in EU
Panasonic Testing Centre
Panasonic Corporation
1006 Kadoma,
Kadoma City Osaka,Japan
ump
t P
er
Mo
del No.
Modello No.
Model Name
A:
XXXXX XX XXX
B
V a r iou s
:
kW ,
A ss orbi men to m ax
(C onti nuo )
A ss orbi men to m ax in
fa se di Spu nto
C
:
( Conti nuous/C o n
30 A at 5 Se c.M ax
(S tar ting P eri od On ly )
(S ol o i n fas e d i s pun to)
Ope rat ing S pe c. Ar eaVar iou s( No t f or th e P ED )
E
:
b
F :
b
(s olo pe r u so es tern o)
,A014RetnaregirfeRtnaregirfeR■D
TI/BGenoizanitseDnoitanitseD■
℃56 rab3SMPSMP■
A
:
k g V
a r V a
a
r V ariou s
rabm02-02G-H2otatsopmIteS■
n uativ o )
t i
r ious
a r i ous
Warning
-Read the technical instructions before installing the appliance.
-Read the user instructions before using the appliance.
ATTENZIONE
-LEGGERE LE ISTRUZIONI TECNICHE PRIMA DI INSTALLARE
L' APPARECCHIATURA
-LEGGERE IL MANUALE D' USO PRIMA DI AVVIARE
L' APPARECCHIATURA
Panasonic Marketing Europe GmbH
Winsbergring 15,22525
Hamburg,Germany
Country of origin
Made in Japan
Paese di fabbricazione
Fabbricata in Giappone
Variu
)DEP(5300,)DAG(2703NC3600PIN ecidoCEDOC NIP
s
AU-16GE3E5
B220/230/240V~ 50Hz
C1.17kW, 5.35A
D11.5 kg
E41.5 bar
F25.0 bar
AU-20GE3E5
B220/230/240V~ 50Hz
C1.12kW, 5.18A
D11.5 kg
E41.5 bar
F25.0 bar
AU-25GE3E5
B220/230/240V~ 50Hz
C1.80kW, 8.39A
D11.5 kg
E41.5 bar
F25.0 bar
AU-30GE3E5
B220/230/240V~ 50Hz
C1.80kW, 8.39A
D11.5 kg
E41.5 bar
F25.0 bar
AU-16GF3E5
B220/230/240V~ 50Hz
C1.17kW, 5.35A
D11.5 kg
E41.5 bar
F25.0 bar
EN
EN - 11
AU-20GF3E5
B220/230/240V~ 50Hz
C1.40kW, 6.45A
D11.5 kg
E41.5 bar
F25.0 bar
AU-25GF3E5
B220/230/240V~ 50Hz
C1.80kW, 8.39A
D11.5 kg
E41.5 bar
F25.0 bar
Ce que vous devez savoir .........................10
Utilise un équipement correctement et économise l’énergie
82664119438000
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
CV6233338514
CARACTÉRISTIQUES ET REQUÊTES
À PROPOS DE VOTRE CLIMATISEUR À POMPE DE CHALEUR À GAZ
Le climatiseur à pompe de chaleur à gaz (GHP) utilise du gaz comme carburant pour alimenter le compresseur.
Puisqu’il utilise un moteur à gaz, il présente plusieurs caractéristiques.
• Comme l’unité ne gèle pas facilement, le dégivrage n’est pas fréquent même les jours très froids, permettant ainsi
à l’unité de fournir une chaleur stable et continue.
• Puisque sa consommation électrique est d’environ 1 kW, cela en fait l’équipement le moins alimenté en électricité.
Cependant, comme pour un moteur de voiture, des inspections périodiques effectuées par un spécialiste sont pour
des raisons d’efcacité nécessaires pour un fonctionnement satisfaisant. Veuillez vous assurer d’effectuer ces
inspections périodiques.
VEUILLEZ VOUS ASSURER D’AVOIR SIGNÉ UN CONTRAT DE
MAINTENANCE RÉGULIÈRE
An que le GHP fonctionne de manière satisfaisante pour une longue durée, des inspections périodiques sont
nécessaires.
Veuillez effectuer des inspections annuelles prises en charge par un spécialiste.
Que se passe-t-il si vous n’effectuez pas les inspections périodiques ?
1. L’huile moteur va se détériorer, provoquant des dysfonctionnements.
2. L’élément nettoyeur d’air sera obstrué, entraînant la présence de monoxyde de carbone et provoquant une
baisse occasionnelle des performances.
REQUÊTES
Une fois le contrat d’inspections périodiques signé, un spécialiste se déplacera sur site en fonction de la durée
d’utilisation de l’unité. Après une période déterminée d’heures d’utilisation, la télécommande à distance afchera
« Inspection Huile ». A ce moment, nous vous remercions de contacter votre distributeur ou le service après-vente
pour un contrôle.
Pour en savoir plus, veuillez consulter la page 4.
CHANGEMENT DE L’HUILE MOTEUR
Changez périodiquement l’huile moteur et le ltre à huile.
Si vous oubliez de changer l’huile moteur ou si vous utilisez de l’huile non conforme, cela peut avoir
un effet néfaste sur le moteur et provoquer des troubles.
* Huile moteur (Huile d’origine)
ATTENTION
• Un remplissage excessif d’huile aura un effet néfaste sur le moteur.
• Veuillez consulter votre distributeur ou le service après-vente pour le changement d’huile.
NOTIFICATION
• Le texte anglais correspond aux instructions d’origine. Les autres langues sont les
traductions des instructions d’origine.
FR - 2
INSPECTION PÉRIODIQUE
An que le GHP fonctionne de manière satisfaisante pour une longue durée, des inspections périodiques sont
nécessaires. A l’achat de votre GHP, veuillez signer le contrat d’inspections périodiques de Panasonic.
Quand vous signez le contrat d’inspections périodiques, un spécialiste se déplacera sur site.
Pour en savoir plus sur le contrat d’inspections, veuillez consulter votre distributeur ou l’un des centres de service
après-vente.
OPÉRATIONS DE TEST
Eléments d’inspection
(Opérations de test)
• Vérication du fonctionnement de l’installation
• Inspection des câblages électriques
• Inspection de l’équipement lui-même
• Vérication du bloc moteur
• Vérication des dispositifs de protection de sécurité
• Fonctionnement de la collecte des données
• Détection de fuite de gaz
Contactez votre installateur pour réparation si quelque chose
ne fonctionne pas pendant les opérations de test.
FR
FR - 3
INSPECTION PÉRIODIQUE
DURÉE DE LA GARANTIE
La période de garantie est d’UNE année après la date des opérations de test réussies et de la livraison du produit.
Cependant, le moteur lui-même et les pièces remplacées périodiquement sont garantis UNE année après des
opérations de test réussies et de la livraison du produit ou après 2 000 heures de fonctionnement, quelle que soit la
condition qui se produit la première.
INSPECTIONS PÉRIODIQUES APRÈS EXPIRATION DE LA GARANTIE
Le nombre d’inspections dépend des heures de fonctionnement pendant une durée d’une année.
Le tableau ci-dessous montre le cas d’un fonctionnement de 2 000 heures annuels. Si vous avez signé un contrat
d’inspections périodiques, un spécialiste GHP se rendra sur site et effectuera les opérations mentionnées plus haut,
remplacera les pièces défectueuses et réalisera les réglages nécessaires.
ÉLÉMENTS D’INSPECTION PÉRIODIQUES
Calendrier des
inspections
Eléments
d’inspection
Remplacements
périodiques des
pièces
Veuillez laisser la gestion du calendrier des visites au spécialiste.
• Vérication du niveau du uide de refroidissement – Remise à niveau si nécessaire :
chaque 10 000 heures ou tous les cinq ans.
• Vérication du ltre d’évacuation anti-alcali – Remise à niveau si nécessaire :
chaque 10 000 heures ou tous les cinq ans.
• Inspection et réglage de différentes pièces : en fonction du contenu des inspections
périodiques.
Vérication du bloc moteur
Vérication des dispositifs de protection de sécurité
Inspection de l’huile moteur et remise à niveau si nécessaire
Fonctionnement de la collecte des données
Détecteur de fuite de gaz
Intervalle de
remplacement
10 000 heures ou tous
les 5 ans.
• Huile moteur
• Filtre à huile
• Elément nettoyeur d’air
• Prise d’allumage
• Courroie du compresseur
• Tapis d’absorption d’huile
Nom de la pièce
• Garniture du ltre d’évacuation
Remarque: le changement d’huile moteur ne concerne que le moteur lui-même et le sous-
plateau à huile. Remettre à niveau l’huile dans le réservoir d’huile, situé sur la
partie supérieure.
Réglages
périodiques
Les inspections périodiques sont facturées.
Remarque: Le remplacement des pièces est calculé sur la base de 2 000 heures annuelles sur une période de 10
ans.
S’il s’avère nécessaire de remplacer des pièces autres que celles mentionnées ci-dessus, des frais
supplémentaires autre que ceux de l’inspection périodique seront facturés.
Remarque: Si de la poussière ou de la saleté s’accumule sur les ailettes de l’échangeur de chaleur des unités
d’intérieur ou d’extérieur, cela entraînera une perte d’efcacité.
Après avoir consulté votre distributeur ou le service après-vente, veuillez enlever la poussière et laver
l’échangeur de chaleur.
• Le réglage de la vanne d’évacuation du moteur est effectué toutes les 10 000 heures ou tous
les cinq ans.
FR - 4
CONSIGNES DE SÉCURITÉ
AVERTISSEMENT
Ce symbole signale un danger ou une manœuvre périlleuse pouvant engendrer
des blessures physiques graves, voire mortelles.
ATTENTION
Ce symbole signale un danger ou une manœuvre périlleuse pouvant engendrer
des blessures physiques ou des dégâts matériels.
Avant d’utiliser l’unité, veuillez vous assurer d’avoir lu les CONSIGNES DE SÉCURITÉ.
Deux types d’alertes sont listées ci-dessous, l’une est un AVERTISSEMENT et l’autre est un ATTENTION.
Assurez-vous de respecter ces consignes pour des raisons de sécurité.
• Les alertes ont la signication suivante.
• La signication des symboles
« AVERTISSEMENT » ou
« ATTENTION ».
• Veuillez conserver ce manuel à portée de main an que l’opérateur puisse s’y référer facilement.
Si l’opérateur est remplacé, assurez-vous que le nouvel opérateur dispose du manuel pour le lire.
Indique que quelque chose
est « INTERDIT ».
Indique des conseils qui
doivent être suivis.
CONSIGNES AVANT UTILISATION
AVERTISSEMENT
N’installez PAS vous-même l’équipement.
Veuillez demander à votre distributeur ou
à un spécialiste d’installer l’équipement.
Si vous l’installez mal vous-même, cela
pourrait provoquer une décharge électrique,
un incendie ou une fuite d’eau, etc.
Vériez que le tube d’échappement de
l’unité d’extérieur et le tube d’eau de l’unité
d’intérieur ne sont pas connectés ensemble.
Si ces tubes font partie du même circuit,
les gaz d’échappement pourrait fuir dans
la pièce et provoquer un empoisonnement.
Vériez que les tubes sont séparés.
Vériez le type de gaz que vous utilisez.
Si vous utilisez le mauvais type de
gaz, cela pourrait entraîner une
combustion incomplète et provoquer un
empoisonnement par le gaz. Vériez le
type de gaz.
Vériez que chaque unité possède un
circuit électrique exclusif.
Si vous utilisez d’autre(s) équipement(s)
électrique(s) sur le même circuit, vous
pouvez griller un fusible et provoquer des
dommages secondaires à l’équipement.
Vériez le circuit électrique.
FR
Dans les rares cas de fuite de réfrigérant.
Si l’équipement est installé dans une petite
pièce, des mesures doivent être prises
pour garantir que dans les rares cas d’une
fuite de réfrigérant, une certaine limite ne
sera pas dépassée.
Avant l’installation, consultez votre
distributeur sur cette certaine limite. Dans
un cas d’urgence où le réfrigérant fuirait,
cela peut provoquer un accident par
manque d’oxygène dans l’air.
Vériez auprès d’un revendeur ou d’un technicien de service
professionnel que le réfrigérant spécié est utilisé.
L’utilisation d’un réfrigérant autre que celui spécié peut entraîner une défaillance de l’équipement, des
brûlures ou des blessures.
Assurez-vous d’acheter un équipement
certié Panasonic.
Si vous achetez un équipement séparé comme
un nettoyeur d’air ou un humidicateur (dans
les cas d’installation à l’intérieur de l’unité),
veuillez vous assurer d’acheter uniquement
des produits certiés Panasonic. Et demander
à un distributeur professionnel de l’installer.
Si vous l’installez mal vous-même, cela
pourrait provoquer une décharge électrique,
un incendie ou une fuite d’eau, etc. Veuillez
acheter un équipement certié Panasonic.
FR - 5
CONSIGNES DE SÉCURITÉ
Assurez-vous d’installer l’unité
d’extérieur dans un endroit libre de
matériaux volatiles ou inammables.
Veuillez vous assurer qu’il n’existe
aucune présence, aucun ux
ou ensemble de gaz volatiles
ou inammables à proximité de
l’endroit d’installation de l’unité
d’extérieur. Si vous le ne faites pas,
cela peut provoquer un incendie.
Ne pas utiliser cet appareil dans
une atmosphère potentiellement
explosive.
ATTENTION
Vériez les conditions de mise à la terre.
Ne raccordez pas le l de mise à
la terre à des tuyaux à gaz, des
conduites d’eau, un paratonnerre
ou des ls téléphoniques de mise
à la terre. Un l de mise à la terre
défectueux peut provoquer une
électrocution.
Conduite d’eau
Certaines parties sont faites de
plastique et ne sont pas bonnes
pour la mise à la terre.
Conduite de gaz
Il existe un danger d’explosion ou d’incendie.
La terre téléphonique, un paratonnerre
Quand elle est frappée par la foudre, il existe un grand
danger d’un ux électrique massif.
Danger!
Fil de mise
à la terre
Vériez qu’un disjoncteur de fuite à la
terre est en place.
Un disjoncteur de fuite à la terre
est une obligation légale. Ne
pas installer ce dispositif peut
provoquer une décharge électrique
ou un incendie.
N’utilisez qu’un fusible avec une
capacité correcte.
Utiliser un l ou un dispositif
semblable à la place d’un fusible
correct peut provoquer une
décharge électrique ou un incendie.
CONSIGNES D’UTILISATION
AVERTISSEMENT
Assurez-vous que les gaz d’échappement
en provenance de l’unité d’extérieur ne
s’inltrent pas à l’intérieur.
Si les gaz d’échappement rentrent
dans la pièce, cela peut provoquer
une empoisonnement au gaz.
Vériez que vous disposez d’une
alimentation électrique conforme et
vériez la capacité du disjoncteur.
Cela peut provoquer des dommages
à l’équipement ou un incendie.
Vériez l’alimentation électrique et
la capacité du disjoncteur.
Assurez-vous d’installer le tube d’évacuation
de l’unité d’intérieur avec une pente
sufsante pour une évacuation correcte.
Une fuite d’eau peut provoquer des
dommages à votre mobilier et vos
autres biens.
N’utilisez pas l’équipement avec les
mains mouillées.
Cela peut provoquer une décharge
électrique ou des dommages à
l’équipement.
Ne placez pas votre main ou des objets
étrangers sur la sortie ou l’entrée des
unités d’intérieur et d’extérieur.
Un ventilateur tourne à grande
vitesse à l’intérieur et peut
provoquer des blessures.
Ne bloquez pas l’embouchure et la sortie
du tube de l’unité d’extérieur.
Cela peut entraîner une combustion
incomplète et provoquer un incendie ou
une empoisonnement par le gaz.
FR - 6
CONSIGNES DE SÉCURITÉ
AVERTISSEMENT
Ne vous exposez pas vous-même
directement à l’air chaud ou froid
pendant une longue durée.
Cela peut endommager votre
santé.
Ce qu’il faut faire en cas de fuite de gaz
carburant de l’unité d’extérieur.
En cas de fuite de gaz
carburant de l’unité d’extérieur,
éteignez le climatiseur, fermez
la vanne principale de gaz et
contactez votre compagnie de
gaz locale ou le service aprèsvente ou votre distributeur
pour réparations. Cela peut
provoquer un incendie.
Ce qu’il faut faire en cas de fuite de
réfrigérant.
Si le réfrigérant fuit, éteignez
le climatiseur et aérez la
pièce. Puis signalez-le à votre
distributeur ou au service
après-vente. Si la fuite dépasse
une certaine limite, cela
peut provoquer un manque
d’oxygène dans l’air.
N’ouvrez PAS le capot.
A l’intérieur de l’unité, il existe des
pièces en mouvement, des pièces
très chaudes et des pièces à haute
tension, et si vous les touchez, cela
peut provoquer des blessures ou
une décharge électrique.
Si vous détectez une étrange odeur
(une odeur de brûlé, une odeur de gaz)
ou un son anormal ou des vibrations
inhabituelles, éteignez votre climatiseur
et coupez l’alimentation électrique.
ATTENTION
N’enlevez PAS la protection du
ventilateur.
Si vous continuez à utiliser
l’équipement dans ces
circonstances anormales, cela
peut provoquer une décharge
électrique, un incendie ou
une panne moteur. Veuillez
contacter votre distributeur ou
le service après-vente.
Le ventilateur tourne à grande
vitesse et peut provoquer des
blessures.
FR
NE touchez PAS la sortie
d’échappement.
Elle est très chaude et peut
provoquer une brûlure.
NE placez PAS un appareil de chauffage
directement sous la sortie d’air de l’unité
d’intérieur.
Cela peut provoquer une
combustion incomplète de
l’appareil de chauffage.
FR - 7
NE pulvérisez PAS les unités avec un
aérosol inammable.
Veuillez NE PAS stocker ou utiliser
des aérosols combustibles à
proximité des unités.
Cela peut provoquer un incendie.
Aérez la pièce aussi souvent que vous
utilisez des matériaux inammables
avec le climatiseur en marche.
Une aération insufsante peut
provoquer un manque d’oxygène
dans l’air.
CONSIGNES DE SÉCURITÉ
ATTENTION
Veuillez NE PAS utiliser l’unité pour
des applications de refroidissement
particulières comme pour l’alimentation,
les animaux et les plantes, des machines
de précision ou des objets d’art : des
choses qui nécessitent des conditions
de préservation spéciales.
Cela peut provoquer une
détérioration de la qualité des
aliments, etc.
NE placez PAS de réservoirs d’eau au sommet de l’unité d’intérieur.
Veuillez NE PAS placer de vases de eurs ou des choses similaires qui
contiennent de l’eau au sommet de l’unité d’intérieur.
Cela peut provoquer des dommages à l’isolation électrique de l’unité
d’intérieur et une décharge électrique.
Ne placez PAS d’animaux ou de plantes
directement sous la sortie d’air.
Cela peut affecter sérieusement
les animaux ou les plantes.
Veuillez NE PAS utiliser la
télécommande avec un objet
pointu.
Cela peut
Veuillez respecter les règles suivantes
concernant l’alimentation électrique installée à
proximité de l’unité :
•
endommager la
télécommande.
Assurez-vous d’utiliser un ltre
à air dans l’unité d’intérieur.
De la poussière et
de la saleté peuvent
• Veuillez mettre sous tension l’interrupteur au moins
pénétrer dans l’unité
et provoquer une
défaillance.
N’utilisez PAS le climatiseur avec
les portes ou les fenêtres ouvertes.
Cela peut provoquer
un givrage autour de
la partie de décharge.
NE bloquez PAS l’entrée ou la
sortie des unités d’intérieur et
d’extérieur.
Cela peut provoquer une
perte du refroidissement
ou du chauffage. Cela
peut aussi provoquer
• Pendant l’entretien, mettez l’unité HORS tension.
• Pendant les saisons d’utilisation, veuillez NE PAS
des dommages à
l’équipement.
REQUÊTES
Veuillez NE PAS faire fonctionner l’équipement avec
l’interrupteur du disjoncteur.
Votre climatiseur est un climatiseur multiple.
Si vous éteignez l’une des alimentations électriques
installées à proximité de l’unité, toutes les unités
avec la même alimentation électrique deviendront
inopérantes.
5 heures avant d’utiliser le climatiseur.
An de protéger le compresseur, le carter de
chauffage est fourni.
Veuillez vous assurer de respecter les règles suivantes.
Pour l’inspection
ou quand vous
voulez l’utiliser
Le climatiseur
Source
d’alimentation
est mis SOUS
tension au
moins 5 heures
à l’avance.
mettre l’unité HORS tension.
FR - 8
Laissez l’unité
SOUS tension
pendant les
saison d’utilisation
de l’équipement.
SOUS tensionHORS tension
Laissez l’unité
HORS tension
pendant les
saison de nonutilisation de
l’équipement.
Loading...
+ 44 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.