Panasonic PT-AE1000E, PT-AE1000U Service Manual

PT-AE1000U PT-AE1000E
ORDER NO. VED0610374C0
D10
LCD Projector
© 2006 Matsushita Electric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law.
PT-AE1000U / PT-AE1000E
PT-AE1000U / PT-AE1000E
PT-AE1000U / PT-AE1000E
CONTENTS
Page Page
1 Safety Precautions 5
1.1. General Guidelines
1.2. Leakage Current Check
1.3. UV Precaution and UHM Lamp Precautions
2 Ext Option
2.1. Procedure to enter EXT OPTION
2.2. EXT OPTION Menu and Functions
2.3. Canceling EXT OPTION
3 Self-Check Mode
3.1. Procedure to enter the self-check mode
3.2. Self Check Display and Contents
3.3. Canceling the self-check mode
4 Flicker Adjustment Mode
4.1. Procedure to enter the adjustment mode
4.2. Adjustment Display and Contents
4.3. Canceling the flicker adjustment mode
5 Using the SERIAL Connector
5.1. Connection
5.2. Pin Layout and Signal Names for SERIAL Connector
5.3. Communication Settings
5.4. Basic Format
5.5. Control / Query Commands
5.6. Communication Cable Specifications
5.7. Signal Selector Connecting Cable Specifications
6 Disassembly Instructions
6.1. Printed Circuit Board and Main Parts Location
6.2. Removal of Upper Case
6.3. Removal of A-P.C.Board
6.4. Removal of J-P.C.Board
6.5. Removal of K1-P.C.Board
6.6. Removal of R-P.C.Board
6.7. Removal of S-P.C.Board
6.8. Removal of V-P.C.Board
6.9. Removal of B/Q-Module
6.10. Removal of P-Module
6.11. Removal of Lamp Unit
6.12. Removal of Analysis Block
6.13. Removal of LCD Block / Projection Lens
6.14. Replacement of Phase Difference Board
6.15. Replacement of Incidence Polarizer
6.16. Replacement of PBS Array (Analysis Block)
10
10 10 10 11 11 13 13
14
15 16 16 17 17 18 18 18 19 20 20 21 21 22 22 22
5 5 5
6
6 6 6
7
7 8 9
9
9 9 9
6.17. Removal of Iris Unit
7 Measurement and Adjustments
7.1. Adjustment Procedure Flowchart
7.2. Cautions for Adjustment
7.3. Setting Before Adjustment
7.4. Lighting Area Adjustment
7.5. Software for Adjustment
7.6. Flicker Adjustment
7.7. Input Level Adjustment (RGB)
8 Troubleshooting 9 Interconnection Block Diagram
9.1. Interconnection Block Diagram (1/2)
9.2. Interconnection Block Diagram (2/2)
10 Block Diagram
10.1. Power Supply
10.2. Signal Processing (1/3)
10.3. Signal Processing (2/3)
10.4. Signal Processing (3/3)
11 Schematic Diagram
11.1. A-P.C.Board (1/8)
11.2. A-P.C.Board (2/8)
11.3. A-P.C.Board (3/8)
11.4. A-P.C.Board (4/8)
11.5. A-P.C.Board (5/8)
11.6. A-P.C.Board (6/8)
11.7. A-P.C.Board (7/8)
11.8. A-P.C.Board (8/8)
11.9. K1-P.C.Board, K2-P.C.Board
11.10. J-P.C.Board, S-P.C.Board, R-P.C.Board
11.11. V-P.C.Board, H-P.C.Board, M1-P.C.Board, M2-P.C.Board
11.12. B-Module (1/2)
11.13. B-Module (2/2)
12 C irc uit Boards
12.1. A-P.C.Board (Foil Side)
12.2. A-P.C.Board (Component Side)
12.3. J-P.C.Board, V-P.C.Board
13 Te rm inal guide of ICs and tr ansis tors 14 Ex ploded View s 15 Replacement Parts List
23
24
24 24 24 24 26 29 30
31 41
41 42
43
43 44 45 46
47
48 49 50 51 52 53 54 55 56 57
58 59 60
61
61 62 63
65 66 70
1 Safety Precautions
1.1. General Guidelines
· For continued safety, no modification of any circuit must be
attempted.
· Unplug the power cord from the power outlet before
disassembling this projector.
· Use correctly the supplied power cord and must ground it.
· It is advisable to use an isolation transfo rmer in the AC
power line before the service.
· Be careful not to touch the rotation part (cooling fan, etc.) of
this projector when you service with the upper case removed and the power supply turned ON.
· Observe the original lead dress during the service. If a short
circuit is found, replace all the parts overheated or damaged by the short circuit.
· After the service, all the protective devices such as
insulation barriers, insulation papers, shields, and isolation R-C combinations must be properly installed.
· After the service, check the leakage current to prevent the
customer from getting an electric shock.
1.2. Leakage Current Check
1. Prepare the measuring circuit as shown in Fig.1. Be sure to use a voltmeter having the performance
described in Table 1.
PT-AE1000U / PT-AE1000E
Fig. 2
2. Assemble the circuit as shown in Fig. 2. Plug the power cord in a power outlet.
3. Connect M1 to T1 according to Fig. 2 and measure the voltage.
4. Change the connection of M1 from T1 to T2 and measure the voltage again.
5. The voltmeter must read 0.375 V or lower in both of steps 3 and 4. This means that the current must be 0.75 mA or less.
6. If the reading is out of the above standard, the projector must be repaired and rechecked before returning to the customer because of a possibility of an electric shock.
1.3. UV Precaution and UHM Lamp
Precautions
· Be sure to unplug the power cord from the power outlet when replacing the lamp.
· Because the lamp reaches a very high temperature during its operation, wait until it cools completely when replacing the Lamp Unit.
· The lamp emits small amounts of UV-radiation, avoid direct­eye contact with the light.
· The lamp unit has high internal pressure. If improperly handled, explosion might result.
· Because the high pressure lamp involves a risk of failure, never touch the lamp wire lead during the service. (See Fig.
3)
Fig. 1
Table 1
Fig.3
PT-AE1000U / PT-AE1000E
2 Ext Option
This projector has EXT OPTION in addition to standard on-screen menus.
· There are SELF CHECK and FLICKER ADJUST for service, etc.
2.1. Procedure to enter EXT OPTION
1. When the projector is power ON, press "POWER" button on the main unit or remote control unit to display "POWER OFF" confirmation screen.
2. Press the right-arrow "
3. On the main unit or remote control unit, press the buttons in order of up-arrow " down-arrow "
(When the "ENTER" button is pressed, "EXT OPTION" menu is displayed.)
" and "ENTER".
2.2. EXT OPTION Menu and Functions
" button to select "CANCEL" in the "POWER OFF" confirmation screen.
", down-arrow " ", up-arrow " ",
· FAN FULLMODE Setting the cooling fan motor rotation speed
Switching ON "FAN FULLMODE", the rotation level of the fan becomes high-speed rotation (fixed). Moreover, when "FAN
− −
FULLMODE" is ON, changing "ALTITUDE" in OPTION becomes impossible (setting FAN FULLMODE is given priority more than ALTITUDE).
· AUTO SETUP Setting AUTO SETUP mode
NORMAL: To set the normal mode (the dot clock is adjusted strictly)
− −
SPECIAL: To set the special mode (the dot clock is adjusted roughly)
− −
* Do not change the initial setting (NORMAL).
· SELF CHECK To enter the self-check mode
· FLICKER ADJUST To enter the flicker adjustment mode
· 525i SD When non-standard signal of 525i/625i is inputted (AV amplifier, etc.), synchronization might be disordered according to
connected equipment. In this case, set 525i SD to ON.
· 525p OS When 525p/625p signal is inputted, reflection noise (vertical striated beat) might be generated according to connected
equipment. In this case, set 525p OS to ON. However, the resolution decreases a little.
· HPLL When non-standard signal of VIDEO/S-VIDEO is inputted (VTR, VHD, etc.), horizontal synchronization might be disordered
according to connected equipment. In this case, set HPLL to OFF.
2.3. Canceling EXT OPTION
Press "MENU" button on the main unit or remote control unit.
3 Self-Check Mode
This mode is used to narrow down the location of the failure.
3.1. Procedure to enter the self-check mode
Select "SELF CHECK" on "EXT OPTION" menu and press "ENTER" button on the main unit or remote control unit.
PT-AE1000U / PT-AE1000E
PT-AE1000U / PT-AE1000E
3.2. Self Check Display and Contents
PT-AE1000U / PT-AE1000E
3.3. Canceling the self-check mode
Press "MENU" button on the main unit or remote control unit.
4 Flicker Adjustment Mode
If replacing the optical parts (LCD Panel / LCD block) or A-P.C.Board of this projector, enter the flicker adjustment mode and minimize the flicker.
4.1. Procedure to enter the adjustment mode
Select "FLICKER ADJUST" on "EXT OPTION" menu and press "ENTER" button on the main unit or remote control unit.
Note:
"DESK setting (red)" is displayed when entering the adjustment mode.
4.2. Adjustment Display and Contents
· Setting value is increased and decreased with the right-arrow " " and left-arrow " " buttons.
"
": Decrease, " ": Increase
Adjust the setting value to minimize the flicker on the screen.
− −
Execute the adjustment by 6 patterns below.
− −
· The pattern (adjustment display) is switched with the up-arrow "
"
": Forward direction, " ": Reverse direction
There are 6 patterns of "DESK setting (red)", "DESK setting (blue)", "DESK setting (green)", "CEILING setting (red)",
− −
"CEILING setting (blue)" and "CEILING setting (green)".
The setting value is saved into this projector when the pattern is switched.
− −
" and down-arrow " " buttons.
4.3. Canceling the flicker adjustment mode
Press "MENU" button on the main unit or remote control unit.
Note:
When "MENU" button is pressed, the setting value at that time is saved into this projector and the adjustment mode is canceled.
PT-AE1000U / PT-AE1000E
5 Using the SERIAL Connector
The serial connector which is on the back connector panel of the projector conforms to RS-232C standard. This projector can be controlled by a PC which is connected as shown in "5.1. Connection".
For controlling this projector by a PC, requires communication software on the market, and inputs control commands according to communication settings and basic format below.
5.1. Connection
Note:
Use a proper communication cable which is suitable for the PC to connect SERIAL connector and the PC.
5.2. Pin Layout and Signal Names for SERIAL Connector
Pin No Signal Name Contents
1 --- NC 2 TXD Transmit data 3 RXD Receive data 4 --- NC 5 GND Ground 6 DSR 7 CTS Connected internally 8 RTS 9 --- NC
5.3. Communication Settings
Signal Level Contents Description
Sync. method Asynchronous Synchronizes every 1 character (8 bits)
Baud rate Conforms to 9 600 bps Data transfer speed
Parity RS-232C None Error detection method
Character length standard 8bits Number of bit composing 1 character
Stop bit 1bit Uses stop bit when asynchronous method X parameter Not used S parameter Not used
10
PT-AE1000U / PT-AE1000E
5.4. Basic Format
The data sent from the PC to the projector is transmitted in the format shown below.
Notes:
· If sending multiple commands, check that a call back has been received from the projector for 1 command before sending
the next command.
· When a command which does not require parameters is sent, the colon (:) is not required.
5.5. Control / Query Commands
Control Commands
11
PT-AE1000U / PT-AE1000E
Query Commands
Parameters
[Example]
When controls the audio volume to +30 by a PC (Sends commands as the following:)
· When a command which does not require parameters is sent, the colon (:) is not required.
12
PT-AE1000U / PT-AE1000E
5.6. Communication Cable Specifications
5.7. Signal Selector Connecting Cable Specifications
When connecting to a signal selector (ex. TW-SWS62J), use a cable with specifications below. Connecting method: Connects a video signal cable from the signal selector to "VIDEO IN", and an RGB signal cable to "PC IN".
Note:
Set VP control terminal switch of the signal selector to VP TYPE "B".
13
PT-AE1000U / PT-AE1000E
6 Disassembly Instructions
Warning:
· Be sure to unplug the power cord from the power outlet before disassembling this projector.
Caution:
· While turning over a printed circuit board, be sure to put a insulating material under it to prevent a short circuit.
· Printed circuit boards and wires must not be pulled forcibly, but be handled carefully.
· Connectors also must be handled carefully.
· When reassembling, replace used adhesive tape with new one (Do not re-use used tape).
· After repairing this projector, be sure to put back the wires and connectors to the original condition.
· After disassembling or repairing this projector, do the following confirmation work for LCD panels damage prevention.
1. Disconnect 3 flexible cables of LCD Panels (R/G/B).
2. Turn ON the power and confirm the -6V detection LED (D1031) lights. (If it does not light, check and repair the -6V circuit.)
3. Turn OFF the power and connect the 3 flexible cables of LCD Panels.
14
6.1. Printed Circuit Board and Main Parts Location
Electrical Parts
PT-AE1000U / PT-AE1000E
Optical Parts
15
PT-AE1000U / PT-AE1000E
6.2. Removal of Upper Case
1. Lift the rear side of the top panel and disconnect the top panel Open/Close hook, then open the top panel.
6.3. Removal of A-P.C.Board
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
2. While pressing hooks of the 2 top panel fastening devices, remove the top panel.
3. Unscrew the 2 screws and remove the connector cover.
4. Unscrew the 11 screws and remove the A-P.C.Board.
3. Loosen the 3 screws until they idle.
4. Slide the lamp lock button to release, and remove the lamp unit block (with lamp unit cover).
5. Unscrew the 8 screws and remove the upper case.
16
PT-AE1000U / PT-AE1000E
6.4. Removal of J-P.C.Board
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
3. Unscrew the 2 screws and remove the connector cover.
6.5. Removal of K1-P.C.Board
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
3. Unscrew the 1 screw and release the grounding terminal.
4. Unscrew the 4 screws and remove the block of Analysis Block, LCD Block, Shift Mechanism and Projection Lens.
4. Unscrew the 3 screws and remove the J-P.C.Board.
[PT-AE1000U]
[PT-AE1000E]
5. Unscrew the 4 screws and remove the intake air duct 2.
6. Unscrew the 1 screw and remove the intake air duct 1.
17
PT-AE1000U / PT-AE1000E
7. Unscrew the 3 screws and remove the K1-P.C.Board.
6.6. Removal of R-P.C.Board
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the V-P.C.Board.
4. Unscrew the 1 screw and remove the R-P.C.Board.
6.7. Removal of S-P.C.Board
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and release the grounding terminal.
3. Unscrew the 1 screw and remove the operation button block.
3. Unscrew the 1 screw and remove the P.C.Board attachment fittings with R-P.C.Board.
Note:
· R-P.C.Board is secured. Be careful not to apply
excessive force.
4. Unscrew the 2 screws and remove the S-P.C.Board.
6.8. Removal of V-P.C.Board
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
18
2. Unscrew the 2 screws and remove the V-P.C.Board.
6.9. Removal of B/Q-Module
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
PT-AE1000U / PT-AE1000E
6. Unscrew the 3 screws and remove the power block (B/Q­Module and P-Module).
3. Unscrew the 2 screws and remove the V-P.C.Board.
4. Unscrew the 1 screw and remove the P.C.Board attachment fittings with R-P.C.Board.
Note:
· R-P.C.Board is secured. Be careful not to apply
excessive force.
5. Unscrew the 1 screw and release the grounding terminal.
7. Unscrew the 1 screw and separate the B/Q-Module block and P-Module block.
8. Unscrew the 2 screws.
9. While pressing to shut each hook of the 2 resinous stands, remove the B/Q-Module.
19
PT-AE1000U / PT-AE1000E
6.10. Removal of P-Module
1. Remove the P-Module block according to the steps 1 through 7 in the section 6.9. "Removal of B/Q-Module".
2. Unscrew the 2 screws.
3. While pressing to shut each hook of the 2 resinous stands, remove the P-Module.
2. Loosen the 3 screws until they idle.
3. Slide the lamp lock button to release, and remove the lamp unit block (with lamp unit cover).
6.11. Removal of Lamp Unit
1. Lift the rear side of the top panel and disconnect the top panel Open/Close hook, then open the top panel.
20
Note:
· When installing the lamp unit in the main unit, place
it in a specified position and press the connector side and the opposite side of the lamp unit (arrow positions shown in the figure below), and confirm the lamp unit is inserted securely. Then, tighten the 3 screws fixing the lamp unit cover.
PT-AE1000U / PT-AE1000E
Note:
· There is not enough space between the analysis
block and LCD block. Be careful not to damage nor dirty precision components (LCD panel, phase difference board, etc.) when removing.
6.12. Removal of Analysis Block
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
3. Unscrew the 1 screw and release the grounding terminal.
4. Unscrew the 4 screws and remove the block of Analysis Block, LCD Block, Shift Mechanism and Projection Lens.
6.13. Removal of LCD Block / Projection Lens
1. Remove the block of LCD Block, Shift Mechanism and
Projection Lens according to the section 6.12. "Removal of Analysis Block".
2. Unscrew the 5 screws, and separate the LCD block and
block of Shift Mechanism and Projection Lens.
3. Unscrew the 4 screws and remove the projection lens .
5. Unscrew the 2 screws and remove the block of LCD Block, Shift Mechanism and Projection Lens.
21
PT-AE1000U / PT-AE1000E
6.14. Replacement of Phase Difference Board
The procedure is described as an example of phase difference board (G).
1. Remove the upper case according to the section 6.2.
"Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
3. Mark positions of the phase difference board (G).
Note:
· Mark accurately as possible because the marks will
be used for resetting the phase difference board position.
4. Unscrew the 1 screw and remove the phase difference
board (G).
5. Attach a new phase difference board and align it with the
mark.
6. Tighten the 1 screw with care not to move the phase
difference board position.
polarizer (G).
1. Remove the phase difference board according to the steps 1 through 4 in the section 6.14. "Replacement of Phase Difference Board".
2. Mark positions of the incidence polarizer (G).
Note:
· Mark accurately as possible because the marks will
be used for resetting the incidence polarizer position.
3. Unscrew the 1 screw and remove the incidence polarizer (G).
4. Attach a new incidence polarizer and align it with the mark.
5. Tighten the 1 screw with care not to move the incidence polarizer position.
6.15. Replacement of Incidence Polarizer
The procedure is described as an example of incidence
6.16. Replacement of PBS Array (Analysis Block)
1. Remove the upper case according to the section 6.2.
"Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
3. Unscrew the 4 screws and remove the analysis case
(upper).
Note:
· The incidence polarizer and phase difference board
22
PT-AE1000U / PT-AE1000E
are installed in the analysis case (upper). Be careful not to shift the installation positions nor damage them.
4. Remove the PBS array.
5. Install new PBS array.
Note:
· Be careful not to mistake the direction
(inside/outside, upper/lower).
· Be careful not to touch the surface of PBS array.
3. Unscrew the 1 screw and remove the integrator hold spring.
4. Unscrew the 2 screws and remove the iris unit .
6.17. Removal of Iris Unit
1. Remove the analysis block according to the steps 1 through 4 in the section 6.12. "Removal of Analysis Block".
2. Unscrew the 4 screws and remove the analysis case (upper).
Note:
· The incidence polarizer and phase difference board
are installed in the analysis case (upper). Be careful not to shift the installation positions nor damage them.
23
PT-AE1000U / PT-AE1000E
7 Measurement and Adjustments
7.1. Adjustment Procedure Flowchart
7.2. Cautions for Adjustment
· Never turn off the MAIN POWER switch until every fan completely stops.
· To maintain and ensure safety, always use the designated components for replacement parts.
· If removing any clamps, lead wires or connectors, always place them back in their proper locations.
· Be careful not to damage the lead wires or components when using a soldering iron or similar tool.
7.3. Setting Before Adjustment
· Set up the projector to obtain the projection distance below.
· Turn the zoom ring of the projector to obtain the largest size of the picture.
7.4. Lighting Area Adjustment
7.4.1. Tools to be used
Service Kit: This kit is composed of 3 extension flexible cables and 5 connector extension cables.
Note:
· Consult your dealer or Authorized Service Center for the service kit.
7.4.2. Preparation
1. Remove the upper case according to the section 6.2. "Removal of Upper Case".
2. Install the lamp unit block (with lamp unit cover) and tighten the 3 screws fixing the lamp unit cover.
3. Unscrew the 2 screws fixing the A-P.C.Board.
24
PT-AE1000U / PT-AE1000E
4. Connect the service kit (extension cables).
· Each flexible cable of LCD Panels (R/G/B) - Connectors (A1/A2/ A3) on A-P.C.Board
· Intake fan connector - Connector (A15) on A-P.C.Board
· Power fan connector - Connector (A16) on A-P.C.Board
· PBS fan connector - Connector (A18) on A-P.C.Board
· Thermosensor (Intake air) connector - Connector (A7) on A-P.C.Board
· S-P.C.Board connector - Connector (A8) on A-P.C.Board
5. Covering with an insulator (cloth or the like) to prevent a short circuit, set the A-P.C.Board block on the main unit.
Note:
· Handle with care not to apply external force to connecting parts which connect the main unit and A-P.C.Board.
7.4.3. Adjustment Procedure
7.4.3.1. Outline
When the lighting area is off from the adjustment and color unevenness appears, adjust the lighting area into correct position.
Symptom Measure Magenta unevenness G Reflector Adjustment Cyan unevenness R Reflector Adjustment Yellow unevenness B Reflector Adjustment
· Shifting the mirror adjusting lever horizontally, adjust color unevenness on the screen upper/lower sides.
· Twisting the mirror adjusting lever, adjust color unevenness on the screen right/left sides.
25
Loading...
+ 57 hidden pages