INSTRUCTION MANUAL
LED Type Optical Displacement Sensor
General Purpose Controller
Thank you very much for using SUNX sensors. Please read this
Instruction Manual carefully and thoroughly for the correct and optimum
use of this sensor. Kindly keep this manual in a convenient place for
quick reference.
This product is not a safety sensor. Its use is not intended or designed
to protect life and prevent body injury or property damage from
dangerous parts of machinery. It is a normal object detection sensor.
LH-CL6,
LH-CL6P
For details, please refer to the User’s Manual of LH-CL6(P).
z SPECIFICATIONS
Type NPN output type PNP output type
Item
Applicable sensor head (Note 2)
Supply voltage 24V DCѰ10% Ripple P-P 10% or less
Current consumption 250mA or less (including sensor head)
Sampling frequency 5kHz approx.
Gain setting AUTO (Note 3)/SELECT (settable in 11 steps)
Analog output
Analog voltage output
Analog current output
Comparative output
(OUT 1, OUT 2)
Alarm output
0-ADJ input
Ext. Sync. input
Remote interlock
input
Timer function Incorporated
Interference prevention function (Note 5)
Display 5 digit red LED display
Ambient temperature 0 to Ҥ50ѵ (No dew condensation), Storage: ҥ20 to Ҥ60ѵ
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Material Enclosure: Polycarbonate
Cable 0.22mm
Weight 160g approx.
Accessory
Notes:
Conditions which have not been specified are to be taken as: 24V DC supply voltage, Ҥ20ѵ
1)
ambient temperature, SELECT gain setting, 300ms response time setting, center measuring
distance, interference prevention function not used, and white ceramic board object.
2) For details of the applicable sensor head, please refer to the instruction manual of the sensor
head.
3) Take care that when the gain is set to AUTO, the linearity and the resolution may deteriorate.
4) The linearity of the sensor head and the controller has been adjusted at the time of
shipment. Carry out the shift adjustment and the span adjustment to suit the operating
conditions.
5) Take care that the linearity, resolution and the response time may deteriorate when the
interference prevention function is used.
Model No.
Response time
Temp. characteristics
Span adjustment
Shift adjustment
NPN open-collector transistor
ОMaximum sink current: 100mA
ОApplied voltage: 30V DC or less
ОResidual voltage: 1.5V or less
Output operation
Short-circuit protection
Output operation
Short-circuit protection
ON or OFF when threshold level is reached, selectable by jog switch
NPN open-collector transistor
ОMaximum sink current: 100mA
ОApplied voltage: 30V DC or less
ОResidual voltage: 1.5V or less
OFF when DARK, BRIGHT, NEAR, FAR, or other error is displayed.
Low (0 to 1V): 0-ADJ operation
ОApplied voltage: 30V DC or less
Low (0 to 1V):
Ext. Sync. input effective
ОApplied voltage: 30V DC or less
Low (0 to 1V): Emission
High (ҤV or open): Emission stopped
ОApplied voltage: 30V DC or less
LH-CL6 LH-CL6P
LH-54, LH-58, LH-512
Analog voltage
ОOutput voltage: ҥ5 to Ҥ5V
ОOutput impedance: 100
Analog current
ОOutput current: 4 to 20mA
ОLoad resistance: 300or less
0. 5ms/1ms/10ms/20ms/30ms/40ms/100ms/300ms
selectable by jog switch
Within Ѱ0.04% F.S./ѵ
Within Ѱ10% F.S. (Note 4)
PNP open-collector transistor
ОMaximum source current: 100mA
(between comparative output and 0V)
(at 100mA sink current)
(at 16mA sink current)
(between alarm output and 0V)
(at 100mA sink current)
(at 16mA sink current)
Incorporated (Up to two sensor heads can be connected.)
MS-DIN-3
0.4V or less
0.4V or less
2
13-core composite cabtyre cable, 2m long
(Controller mounting bracket): 1 No.
ОApplied voltage: 30V DC or less
(between comparative output and ҤV)
ОResidual voltage: 1.5V or less
(at 100mA source current)
0.4V or less
(at 16mA source current)
Incorporated
PNP open-collector transistor
ОMaximum source current: 100mA
ОApplied voltage: 30V DC or less
(between alarm output and ҤV)
ОResidual voltage: 1.5V or less
(at 100mA source current)
0.4V or less
(at 16mA source current)
ҥ
High (ҤV): 0-ADJ operation
ОApplied voltage: 30V DC or less
High (ҤV):
Ext. Sync. input effective
ОApplied voltage: 30V DC or less
High (ҤV): Emission
Low (0 to 1V, or open): Emission stopped
ОApplied voltage: 30V DC or less
x CAUTIONS
This controller has been designed to meet the specifications when used
along with the optional exclusive sensor heads. In case it is used in a
combination that does not use the exclusive sensor heads, not only the
specifications may not be met, but it may also cause an accident, etc.
Hence, always use this controller along with the exclusive sensor
heads.
ӟ Make sure to carry out the wiring in the power supply off condition.
ӟ Take care that wrong wiring will damage the sensor.
ӟ Verify that the supply voltage variation is within the rating.
ӟ Use this product 10 min. after the power is supplied. Immediately
on supply of power, the electrical circuit is yet to stabilize, which
may cause variation in measured values.
ӟ Take care that after switching on the power supply, there is a
muting time of 5 sec.
ӟ If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
ӟ In case noise generating equipment
(switching regulator, inverter motor, etc.) is
used in the vicinity of this product, connect
the frame ground (F.G.) terminal of the
equipment to an actual ground.
ӟ Do not run the wires together with high-
voltage lines or power lines or put them in
the same raceway. This can cause
malfunction due to induction.
ӟ The controller cable can be extended up to total 50m with a
0.22mm
2
, or more, cable. However, use a 0.15mm2shield wire for
the analog output cable extension.
ӟ The analog output and the alarm output are not incorporated with a
short-circuit protection circuit. Do not connect them directly to a
power supply or a capacitive load.
ӟ Avoid dust, dirt, and steam.
ӟ Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
ӟ If the controller is used for a long time, although it becomes hot, this
does not indicate any abnormality. However, if the controller is
used by being enclosed in a control box, make sure that heat is not
trapped inside by providing for heat radiation or cooling by fan, etc.
ӟ The operation panel may get hot. However, this does not indicate
any abnormality.
ӟ This sensor is suitable for indoor use only.
c MOUNTING
How to mount the controller
Ο Fit the rear part of the mounting
section on the attached controller
mounting bracket (
MS-DIN-3
35mm width DIN rail.
Π Pushing the controller forward,
press down the front part of the
mounting section on the controller
mounting bracket (
MS-DIN-3
the DIN rail to fit it.
How to remove the controller
Ο Push the controller forward.
Lift up the front part of the controller
Π
to remove it.
Note: Take care that if the front part is lifted
without pushing the controller
forwards, the hooks on the rear
portion of the mounting section are
likely to break.
) or a
) or
Π
Π
Ο
Ο
v CONNECTION
Ҥ
ҥ
Ҥ
ҥ
Ҥ
ҥ
24VӸDC
Ѱ10ҡ
Load
Load
Load
100mA max.
100mA max.
Z
D1
T
r
1
Z
D2
Z
D3
100mA max.
T
r
2
T
r
3
D
1
Z
D4
Ұɠ
Ұɠ
Ұɠ
4.7k
4.7k
4.7k
4.7k
22k
22k
D
2
D
3
D
4
D
5
Ҥ12ɾ
Z
D5
100
Color code
(Brown)
Ҥɾ
(
Black/Gray) OUTɡ
(
Gray)
Alarm
output
(
Black/White) OUTɠ
(
Blue) 0ɾ
(
Black shield) Analog voltage output GND
(
Violet) Ext. Sync. input
(Black)
Analog voltage output ҥ5 to Ҥ5V (Note 1
)
(
Light blue) 0-ADJ input
(
White) Analog current output 4 to 20mA (Note 2
)
(
White shield) Analog current output GND
(
Pink/Black) Input COM
(
Blue/White) Input COM
Internal circuit
Users' circuit
(
Pink) Remote interlock input
(
Orange/Violet)Ӹ
Interference prevention
I/O (Note 3
)
Main circuit
ӟ Connection of sensor head to controller
Make sure to connect or disconnect the connector to the
controller in the power supply off condition.
ОHold the sensor head's connector and insert it into the connector
provided on the controller for sensor head connection. Insert till it
locks.
Controller
Connector outer ring
Connector for
sensor head
Ұ To remove the sensor head, hold its connector by the outer ring and
pull it straight out. While removing the connector from the controller,
take care not to touch the terminals inside the connector.
Do not pull by holding the cable, as this can result in cable
disconnection.
ӟ I/O circuit diagram
ОLH-CL6/NPN output type
D
1
Z
D1
T
Z
D2
T
r
2
Z
D3
T
r
3
Ҥ
ҥ
Ҥ
ҥ
Main circuit
Z
D
2
D
3
D
4
D
5
22k
22k
Internal circuit
100
D4
Ҥ12ɾ
4.7k
4.7k
4.7k
4.7k
Notes: 1) The device connected to the analog voltage output (black) should have an
input impedance of 1M or more.
2) The device connected to the analog current output (white) should have a
load resistance of 300 or less.
3) Do not connect an interference prevention I/O wire other than that of
LH-CL6(P)
connect together two controllers which have both been set as masters
during interference prevention setting, as this will cause a fault.
Symbols ... D1: Reverse supply polarity protection diode
Ұ1
Non-voltage contact or NPN open-collector transistor
О0-ADJ input, Ext. Sync. input ОRemote interlock input
to the interference prevention I/O (orange/violet). Further, do not
D
to D5: Input protection diode
2
Z
D1
T
r1
to ZD5: Surge absorption zener diode
to Tr3: NPN output transistor
Low (0 to 1V): Effective Low (0 to 1V): Emission
High (ҤV or open): Ineffective High (ҤV or open): Emission stopped
Color code
(Brown)
Ҥɾ
Load
100mA
max.
r
1
(
Black/White
(
Black
/Gray) OUTɡ
(
Gray) Alarm output
(
Blue) 0ɾ
(Black)
(
Black shield) Analog voltage output GND
Z
D5
(
White) Analog current output 4 to 20mA (Note 2
(
White shield) Analog current output GND
(
Light blue) 0-ADJ input
(
Violet) Ext. Sync. input
(
Pink) Remote interlock input
(
Orange/Violet)Ӹ
Interference prevention
I/O (Note 3
(
Pink/Black) Input COM
(
Blue/White) Input C
Users' circuit
Load
)
OUTɠ
100mA max.
Analog voltage output ҥ5 to Ҥ5V (Note 1
)
100mA max.
Ұɠ
O
M
Load
Ұɠ
or
Ҥ
ҥ
Ұɠ
24VӸDC
Ѱ10ҡ
)
)
ОLH-CL6P/PNP output type
Notes: 1) The device connected to the analog voltage output (black) should have an
input impedance of 1M or more.
2) The device connected to the analog current output (white) should have a
load resistance of 300 or less.
3) Do not connect an interference prevention I/O wire other than that of
LH-CL6(P)
to the interference prevention I/O (orange/violet). Further, do not
connect together two controllers which have both been set as masters
during interference prevention setting, as this will cause a fault.
Symbols ... D
: Reverse supply polarity protection diode
1
to D5: Input protection diode
D
2
Z
to ZD5: Surge absorption zener diode
D1
to Tr3: PNP output transistor
T
r1
Ұ1
Non-voltage contact or PNP open-collector transistor
or
О0-ADJ input, Ext. Sync. input ОRemote interlock input
Low (0 to 1V, or open): Ineffective
Low (0 to 1V, or open): Emission stopped
High (ҤV): Effective High (ҤV): Emission
b FUNCTIONAL DESCRIPTION
Description Function
Comparative output
Ο
indicator (Orange LED)
Π
Emitting indicator (Yellow LED)
0-ADJ indicator
Ρ
(Green LED)
Analog output hold
indicator (Orange LED)
Ext. Sync. indicator
Σ
(Green LED)
Τ Jog switch Switch for setting item selection and setting
Υ Mode selection switch
Φ 5 digit red LED display
Connector for sensor
Χ
head connection
Lights up when the respective comparative output
is ON.
Lights up during emission.
Lights up on 0-ADJ operation.
Lights up when analog output hold is set.
Lights up when Ext. Sync. input is effective.
Selects the mode.
(For details, refer to
n SETTING
ϒ
Displays measurement value, and setting item/settings.
Connector for connection to sensor head