13 Exploded View and Replacement Parts List---------- 47
13.1. Exploded View and Mechanical Replacement
Parts List--------------------------------------------------- 47
13.2. Electrical Replacement Parts List ------------------- 51
2
1Safety Precautions
1.1.General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
5. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
6. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
1.1.1.Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading
should be 100 Mohm and over.
When the exposed metal does not have a return path to
the chassis, the reading must be .
1.1.2.Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15μF capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility
of a shock hazard, and the equipment should be repaired
and rechecked before it is returned to the customer.
Figure 1
3
2Warning
2.1.Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor [chip] components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as [anti-static (ESD protected)] can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise ham less motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient
to damage an ES device).
4
2.2.About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For service and repair work, we’d
suggest the use of Pb free solder as well, although Pb solder may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol PbF stamped on the back of PCB.
Caution
• Pb free solder has a higher melting point than standard solder. Typically the melting point is 50 ~ 70 °F (30~40 °C) higher. Please
use a high temperature soldering iron and set it to 700 ± 20 °F (37 0 ± 10 °C).
• Pb free solder will tend to splash when heated too high (about 1100 °F or 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
• After applying PbF solder to double layered boards, please check the component side for excess solder which may flow onto the
opposite side. (see figure below)
Suggested Pb free solder
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu (tin, silver, copper) solder. However, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder can also be used.
5
3Service Navigation
3.1.Important Notice
3.1.1.MANUFACTURING ID NO.
This service manual is for MANUFACTURING ID NO. TC-32LX14N as indicated in the label at side and the model name plate of
the unit.
• Signals other than above may not be displayed properly.
• The above signals are reformatted for optimal viewing on your display.
, PR), HDMI and PC
B
7
4Specifications
Power SourceAC 110-127 V, 60 Hz
Power Consumption
Maximum120 W
Standby Condition0.7 W
Display panel
Aspect Ratio16:9
Visible screen size32 inch class (31.5 inches measured diagonally)
(W × H × Diagonal)27.5 inch × 15.4 inch × 31.5 inch (698 mm × 392 mm × 800 mm)
(No. of pixels)1,049,088 (1,366 (W) × 768 (H)) [4,098 × 768 dots]
Sound
Speaker1-way 2 speakers slim under SP System
Audio Output20 W [10 W + 10 W] ( 10 % THD )
S VIDEO:Mini DIN 4-pin Y: 1.0 V [p-p] (75 Ω) C: 0.286 V [p-p] (75 Ω)
AUDIO L - R:RCA PIN Type × 2 0.5 V [rms]
PB, PR: ±0.35 V [p-p]
AUDIO L-R: RCA PIN Type × 2 0.5 V [rms]
O This TV supports [HDAVI Control 4] function.
HD, VD / 1.0 - 5.0 V [p-p] (high impedance)
SED CAPTION, V-Chip
LO
HDMI (HDAVI Control 4)
Vesa compatible, Photo viewer
Note
Design and Specifications are subject to change without notice. Mass and Dimensions shown are approximate.
8
5Service Mode
5.1.How to enter into Service Mode
While pressing [VOLUME ( - )] button of the main unit, press [INFO] button of the remote control three times within 2 seconds.
5.1.1.Key command
[1] button...Main items Selection in forward direction
[2] button...Main items Selection in reverse direction
[3] button...Sub items Selection in forward direction
[4] button...Sub items Selection in reverse direction
[VOL] button...Value of sub items change in forward direction ( + ), in reverse direction ( - )
5.1.2.Contents of adjustment mode
• Value is shown as a hexadecimal number.
• Preset value differs depending on models.
• After entering the adjustment mode, take note of the value in each item before starting adjustment.
After exchange a LCD panel or A-board, Panel and A-Board matching & Flicker adjustment are required by PANEL-ADJ.
See details at Chapter: Measurements and Adjustments.
5.1.3.How to exit
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
9
5.2.SRV-TOOL
5.2.1.How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
5.2.2.Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory shipment setting].
5.2.3.POWER ON TIME/COUNT
Note : To display TIME/COUNT menu, highlight position, then press MUTE for 3sec.
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
5.2.4.Exit
1. Disconnect the AC cord from wall outlet.
10
5.3.Hotel mode
1. Purpose
Restrict a function for hotels.
2. Access command to the Hotel mode setup menu
In order to display the Hotel mode setup menu, please
enter the following command (within 2 second).
[TV] : Vol. [Down] + [REMOTE] : INPUT (3 times)
Then, the Hotel mode setup menu is displayed.
3. To exit the Hotel mode setup menu
Disconnect AC power cord from wall outlet.
4. Explain the Hotel mode setup menu
itemFunction
ModeSelect hotel mode off/on
InputSelect input signal modes.
Set the input, when each time power is
switched on.
Selection:
-/RF/Component/HDMI1/HDMI2/Video1/
Video2/PC
• Off: give priority to a last memory.
ChannelSelect channel when input signal is RF.
Set the channel, each time power is switched
on.
Selection:
Any channel number or [-].
[-] means the channel when turns off.
VolumeAdjust the volume when each time power is
switched on.
Range:
0 to 100
Vol. MaxAdjust maximum volume.
Range:
0 to 100
OSD CtrlRestrict the OSD.
Selection:
OFF/PATTERN1
• OFF: No restriction
• PATTERN1: restriction
FP CtrlSelect front key conditi ons .
Selection:
Off/Pattern1/All
• Off: altogether valid.
• Pattern1: only input key is valid.
• All: altogether invalid.
Pow CtrlSelect POW ER-ON/OFF condition when AC
power cord is disconnected and then connected.
OFF: The same condition when AC power
cord is disconnected.
ON: Forced power ON condition.
11
6Troubleshooting Guide
Use the self-check function to test the unit.
1. Checking the IIC bus lines
2. Power LED Blinking timing
6.1.Check of the IIC bus lines
6.1.1.How to access
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control
for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote con-
trol for more than 3 seconds.
6.1.2.Exit
Disconnect the AC cord from wall outlet.
6.1.3.Screen display
6.1.4.Check Point
Confirm the following parts if NG was displayed.
12
6.2.Power LED Blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
13
6.3.No Power
First check point
There are following 2 states of No Power indication by power LED.
1. No lit
2. Red is lit then turns red blinking a few seconds later. (See 6.2.)
14
7Disassembly and Assembly Instructions
Caution
Exchange printed circuit board after confirm parts number.
Parts name & DescriptionParts No.
CIRCUIT BOARD ATXN/A10PTRS
CIRCUIT BOARD VTXN/V10PTGS
MODULE PN0AB4GJ00004
7.1.Pedestal
1. Lay down the unit so that the rear cover faces upward.
2. Remove the 4 screws.
3. Remove the pedestal.
7.3.AC cord
1. Remove the screw and Remove the AC cord bracket.
2. Remove the bushing of the AC cord from the AC cord
bracket.
3. Disconnect the connector (P1) of AC cord.
7.2.Rear cover
1. Remove the 15 screws (A).
2. Remove the 2 screws (B),
3. Remove the rear cover.
7.4.P-Board
1. Remove the 3 screws.
2. Remove the Support mold A.
3. Disconnect the connectors (P1, P2, P3).
4. Remove the P-Board.
15
7.5.Side AV bracket
1. Remove the 1 screw (C).
2. Remove the 1 screw (D).
3. Remove the side AV bracket.
7.6.A-Board
1. Remove the 7 screws.
2. Disconnect the connectors (A02, A03, A10, A14, A15,
A20).
3. Remove the A-Board.
7.7.Control panel
1. Disconnect the connector (K1).
2. Remove the 2 screws.
3. Remove the control panel.
7.8.Speaker
1. Remove the 4 screws.
2. Remove the speaker.
16
7.9.P-Board Plastic frame
1. Remove the 4 screws.
2. Remove the P-Board Plastic frame.
7.11.VESA metal
1. Remove the 2 screws (E).
2. Remove the 4 screws (F).
3. Remove the VESA metal.
7.10.A-P-MTG Metal
1. Remove the 5 screws.
2. Remove the A-P-MTG metal R/L/S.
17
7.12.LCD MTG
1. Remove the 2 screws (G).
2. Remove the LCD bottom corner MTG.
7.13.LCD Panel
1. Remove the 4 screws.
2. Remove the LCD panel and LCD side MTG.
3. Remove the 4 screws (H).
4. Remove the 2 screws (J).
5. Remove the LCD BTM MTG.
7.14.V-Board
1. Remove the 1 screw.
2. Disconnect the connector (V10).
3. Remove the V-Board.
18
Loading...
+ 42 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.