Panasonic KX-TDA0155CE Service Manual

© Panasonic System Networks Co., Ltd. 2010 Unauthorized copying and distribution is a violation of law.
ORDER NO. KMS1005777CE
2-Channel Cell Station Unit for DECT Portable Station
KX-TDA0155CE
(for Europe, Asia Oceania, Middle Near East, Russia and Africa)
2
KX-TDA0155CE
TABLE OF CONTENTS
PAG E PAG E
1 Safety Precautions -----------------------------------------------3
1.1. For Service Technicians----------------------------------3
1.2. Caution--------------------------------------------------------3
2Warning--------------------------------------------------------------3
2.1. About Lead Free Solder (PbF: Pb free) --------------3
2.2. Discarding of P. C. Board --------------------------------4
3 Specifications ------------------------------------------------------4 4 Technical Descriptions------------------------------------------5
4.1. Block Diagram ----------------------------------------------5
4.2. Hardware Description -------------------------------------6
5 Installation Instructions-----------------------------------------9
5.1. Connecting the Cell Station to the Hybrid IP­PBX ------------------------------------------------------------9
5.2. Connectiong the CS ------------------------------------- 11
6 Test Mode---------------------------------------------------------- 12
6.1. Required Equipment------------------------------------- 12
6.2. Initial Setting----------------------------------------------- 12
6.3. Command Reference ----------------------------------- 13
7 Troubleshooting Guide---------------------------------------- 19
7.1. Portable Station (PS) Cannot Register to Cell Station (CS) or PS Does not Link CS. -------------- 19
8 Disassembly and Assembly Instructions --------------- 21
8.1. Disassembly Instructions------------------------------- 21
9 Measurements and Adjustments -------------------------- 22
9.1. Version Check and CSID Writing--------------------- 22
9.2. Adjustment for Main Part ------------------------------- 24
9.3. Measurement and Adjustment for RF Part -------- 26
10 Miscellaneous ----------------------------------------------------30
10.1. Terminal guide of ICs, Transistors and Diodes ---30
10.2. How To Replace a Flat Package IC -----------------31
10.3. How to Replace the LLP (Leadless Leadframe Package) IC and IC ground plate- ---------------32
11 Schematic Diagram--------------------------------------------- 34
11.1. Main Board------------------------------------------------- 34
11.2. Waveform -------------------------------------------------- 38
12 Printed Circuit Board ------------------------------------------ 40
12.1. Component View ----------------------------------------- 40
12.2. Bottom View ----------------------------------------------- 41
13 Appendix Information of Schematic Diagram --------- 42 14 Exploded View and Replacement Parts List -----------43
14.1. IC Data------------------------------------------------------ 43
14.2. Cabinet and Electrical Parts Location--------------- 50
14.3. Accessories and Packing Material ------------------- 51
14.4. Replacement Parts List --------------------------------- 52
3
KX-TDA0155CE
1 Safety Precautions
1.1. For Service Technicians
Repair service shall be provided in accordance with repair technology information such as service manual so as to pre­vent fires, injury or electric shock, which can be caused by improper repair work.
1. When repair services are provided, neither the products nor their parts or members shall be remodeled.
2. If a lead wire assembly is supplied as a repair part, the lead wire assembly shall be replaced.
3. FASTON terminals shall be plugged straight in and unplugged straight out.
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
1. Cover plastic parts boxes with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on worktable.
4. Do not grasp IC or LSI pins with bare fingers.
1.2. Caution
When you note the serial number, write down all of the 11 digits. The serial number may be found on the label affixed to the bottom of the unit.
2Warning
2.1. About Lead Free Solder (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that con­tains lead. We will use PbF when discussing the lead free solder used in our manufacturing process which is made from Tin, (Sn), Silver, (Ag), and Copper, (Cu). This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair work we suggest using the same type of solder.
Caution
• PbF solder has a melting point that is 50° ~ 70° F, ( 3 0° ~ 40°C) higher than Pb solder. Please use a soldering iron with tempera­ture control and adjust it to 700° ± 20° F, ( 3 7 0 ° ± 10°C). Exercise care while using higher temperature soldering irons.: Do not heat the PCB for too long time in order to prevent solder splash or damage to the PCB.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100°F, ( 6 0 0 °C).
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the opposite side (See figure, below).
4
KX-TDA0155CE
2.1.1. Suggested PbF Solder
There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper, (Sn+Ag+Cu), you can also use Tin and Copper, (Sn+Cu), or Tin, Zinc, and Bismuth, (Sn+Zn+Bi). Please check the manufac turer's specific instructions for the melting points of their products and any precautions for using their product with other materials. The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3mm, 0.6mm and 1.0mm.
2.2. Discarding of P. C. Board
When discarding P. C. Board, delete all personal information such as telephone directory and caller list or scrap P. C. Board.
3 Specifications
Item Description
Radio Access Method Multi Carrier TDMA-TDD Frequency Band
1880 MHz to 1900 MHz*1 (*1 The number may vary depending on the country /area . In Taiwan, it is 1880 MHz to 1895 MHz.)
Number of Carriers
10*2 (*2 The number may vary depending on the country /area . In Taiwan, it is 8.)
Carrier Spacing 1728 kHz Bit Rate 1152 kbps Carrier Multiplex TDMA, 24 (Tx12, Rx12) slots per frame Frame Length 10 ms Modulation Scheme GFSK
Roll-off factor=0.5 50% roll-off in the transmitter
Max Number of PS Conversations
2 pieces
Data Coding for Modulator Differential Coding Voice CODEC 64 kbps PCM (CCITT G.721) Transmission Output Peak 250 mW Operating conditions 0-40°C (32°F-104°F), 20-80% relative air humidity (not condensing) Operation range Up to 300 m outdoors, Up to 50 m indoors Dimension
Cell Station 164 (L) mm × 133 (W) mm × 40 (D) mm
Weight about 260 g
5
KX-TDA0155CE
4 Technical Descriptions
4.1. Block Diagram
4.1.1. Main Board
KX-TDA0155CE
5.25V
to DLC
Card
T101
Transformer
IC100(Base Band IC/CPU)
RX
TX
Burst Mode
Controller
RF Interface
RF PCM
Ech o
Canceller
CPU
GPIO
IC101
Flash ROM
IC102
SRAM
Line i/f
DIPSW
LED
X101
16.384MHz
X100
10.368MHz
to DLC
Card
IC203
DC/ DC
IC105
Reset IC
Regulators1.8V
3.2V
1.5V PAV3.3V
RF2R5V
232C i/f
C339
C340
C341
IC103/FPGA
SYNC GEN
Framer/Deframer
Dec oder
IC104/GA
DPT i/f
PCM
I/F
6
KX-TDA0155CE
4.2. Hardware Description
4.2.1. Hardware Description
4.2.1.1. Function Description
KX-TDA0155CE is the Cell Station (CS) for TDA and TDE and NCP series. CS converts voice data from PBX to radio signal and transmits to Portable Station (PS). Conversely CS converts radio signal from PS to voice data and transmits to PBX.
4.2.1.2. CPU Circuit
The IC100(SC14429) is CPU with BBIC and DSP and is manufactured by Sitel. This CPU has 16 bits data bus and processes control command from PBX and PS. Application software is stored in 32Mbit Flash Memory (IC101). This Flash Memory is so called Dual Operation type Flash. It is possible to write data onto this Flash Memory in active status so that this Flash Memory is used as EEPROM. The FLASH mem­ory of this Dual Operation type is effective in preventing fatal destruction when remote uploading is failed. If the power failure occurs during program uploading, the FLASH memory data is lost. However, this type of memory is recoverable. Furthermore calibration data for RSSI measurement and clock is stored in the Flash Memory, too. 2Mbit SRAM(IC102) is used as the work area. CN101 is the communication port for service purpose. CN101 is connected to the serial port of the CPU. SW100 is 6bits DIP switch to set the operating modes of CS, site survey mode, program upload mode and so on.
4.2.1.3. Line Interface
This circuit handles data communication to extension port. CS is connected to extension port by 2 wires. The power voltage of CS is DC 40V supplied from extension port by 2 wires. The signal for data transmission is transferred via outside wires. Voice data, control data and superframe synchronisation signal for CS synchronisation is carried on this signal. The signal from extension port is provided to CN100, and provided to DPITS I/F GA (IC104) via filter and pulse transformer (T101). The data received from PBX is inputted to the comparator (pin 36) build in IC104 through Transformer T101. The threshold voltage of the comparator is determined by R238, R239 and R240, then inputted to pin 35 and 37. The data to PBX is outputted from pin 38 and 39 of IC104, drives T101 by Transistor Q200 and transmitted. The signal between DPITS I/F GA (IC104) and FPGA (IC103) is ST-BUS Format digital data which contains data channel, con­trol and voice channel. Voice channel contains 2 PCM data. And superframe synchronisation signal is carried by HK bit of control channel. 2 PCM data and superframe synchronisation signal is transferred to FPGA (IC103).
Note:
The GND of CS(KX-TDA0155CE) is not common to the GND of the PBX itself, so care must be taken when using a measuring device such as an oscilloscope.(Make sure to use the measuring device with its frame ground open.)
7
KX-TDA0155CE
4.2.1.4. FPGA
FPGA (IC103) has the following features.
(1) ST-BUS I/F, BBIC PCM I/F
Extracts voice data from ST-BUS digital data and changes format to BBIC PCM format, then provides it to BBIC(IC100).
(2) Superframe detection, delay compensation
Detects super frame synchronisation signal from HK bit in the ST-BUS digital data and compensates time difference of delay caused by the different cable length from CSIF card, then provides it to PSYNC pin of BBIC(IC100).
(3) Address decoder, internal registers
Address decoder to generate chip select signal for other ICs and internal registers to set FPGA operation.
4.2.1.5. RF Interface Circuit
Data signals for RF control and RX/TX data is connected between BBIC and RF block. The modulated signal is provided to 2 antennas via CN901 and CN900.
4.2.1.5.1. BBIC
SC14429 manufactured by Sitel.
8
KX-TDA0155CE
4.2.1.6. Power Supply Circuit
PAV3.3V, RF2.5V, 3.2V, 1.8V, RF1.8V, 1.5V and 5.25V are generated in CS.
5.5V is output of DC/DC Convertor. Other power supplies are made from 5.25V. PAV3.3V and RF2.5V are the power supply for RF block. 3.2V is the power supply for logic circuit.
1.5V is used as the power supply of FPGA internal core. 1.8V, RF1.8V is the power supply for BBIC.
4.2.1.6.1. Input Filter, Diode Bridge
Input filter for noise rejection and diode bridge for misconnection protection.
4.2.1.6.2. DC/DC Start Up Control Circuit
This circuit controls the DC/DC converter for prompt return from the power interruption start-up.
And when the power supply is low voltage, This circuit controls ON/OFF of the DC/DC converter by DIPSW(SW100)
4.2.1.6.3. DC/DC Converter Circuit
Generate 5.25V from DC40V power supply.
4.2.1.6.4. Power Back Up Circuit
All power supply is backed up by the electric double layer capacitor.
4.2.1.7. Clock Circuit
Two kinds of clock are used in CS.
4.2.1.7.1. BBIC Clock
10.368MHz crystal oscillator is used.
4.2.1.7.2. DPITS I/F GA Clock
16.384MHz crystal oscillator is used. It is used for Reference Clock of DPITS I/F GA.
4.2.1.8. Reset Circuit
It is reset by the signal from Power on Reset or CPU. The reset from Reset IC(IC105) is reset by CPU, and DPITS I/F GA and
FPGA are reset by the port output from CPU.
9
KX-TDA0155CE
5 Installation Instructions
5.1. Connecting the Cell Station to the Hybrid IP-PBX
KX-TDA0155 connecting to KX-TDA100/KX-TDA200/KX-TDA600/KX-TDE100/KX-TDE200/KX-TDE600
Note
The illustration of the PBX is based on the KX-TDE200.
Accessories and User-supplied Items for the CS
Accessories (included): Screws x 2, Washers x 2 User-supplied (not included): RJ11 connector
Note
For details about the DHLC/DLC card, refer to the Installation Manual for your PBX.
10
KX-TDA0155CE
KX-TDA0155 connecting to KX-NCP500/KX-NCP1000
Note
The illustration of the PBX is based on the KX-NCP500.
Accessories and User-supplied Items for the CS
Accessories (included): Screws x 2, Washers x 2 User-supplied (not included): RJ11 connector
Note
For details about the DHLC/DLC card, refer to the Installation Manual for your PBX.
11
KX-TDA0155CE
5.2. Connectiong the CS
1. Connect the cable from CSIF card to the CS.
2. Pass the cable through the groove of the CS (in any direction depending on your preference).
12
KX-TDA0155CE
6 Test Mode
6.1. Required Equipment
1. Personal Computer with serial port.
2. Servuce Jig cable (PSZZ2CA155EU)
3. TEL cord
4. Power Supply Adaptor (PSZZ1TDA0142)
5. AC Adaptor (KX-TCA1 / KX-A11 / PSLP1434)
6. Maintenance software for PC (PSZZ3TD7896M)
6.2. Initial Setting
1. Connect TDA0155CE to your PC with the RS-232C cable, and then power on TDA0155CE with a Power Supply Adaptor.
2. Set DIP switch pin 2 to 6 from OFF to ON.
3. Copy the Maintenance software (KX-TD7896BaseUnit.exe) from Floppy Disk to your PC and double click the KX-TD7896
13
KX-TDA0155CE
4. Set communication environment Click “Config” and configure as follows:
Click “OK”. Selected items will be stored.
6.3. Command Reference
6.3.1. Select From Command Menu
- Example of Operation -
1. Click [test command] tag
14
KX-TDA0155CE
2. Click [ Command menu ] button and select the command that you want execute. (in case of test command "VDD")
3. Set parameters if necessary.
15
KX-TDA0155CE
4. Click [send] button. Maintenance Window is generated, and transmitted command and parameters are displayed. Then receive data from TDA0155CE is displayed.
- Operation of each test command -
A) Test Command "VDD control (VDD)"
1. Click [ Command menu ] button.
2. Point [ battery ].
3. Click [ VDD control (VDD) ].
4. Set the value ("00"-"0F") to the first parameter.
5. Click [ Send ] button. (if returned value is "OK", It succeeded. )
B) Test Command "RF clock (RFC) "
1. Click [ Command menu ] button.
2. Point [ clock ].
3. Click [ RF clock (RFC) ].
4. Set "1" (ON) to the first parameter.
5. Click [ Send ] button. (if returned value is "OK", It succeeded. )
C) Test Command " frequency trimming (SFR)"
1. Click [ Command menu ] button.
2. Point [ clock ].
3. Click [ frequency trimming (SFR) ].
4. Set the value to the first parameter.
5. Click [ Send ] button. (if returned value is "OK", It succeeded. )
16
KX-TDA0155CE
D) Test Command "RFPI write (RFW)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ RFPI write (RFW) ].
4. Set ID (5 byte) to the first parameter
5. Click [ Send ] button. (if returned value is "OK", It succeeded. ) E) Test Command "RFPI read (RFR)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ RFPI read (RFR) ].
4. Click [ Send ] button. (Returned value is ID. ) F) Test Command "software version (VER)"
1. Click [ Command menu ] button.
2. Point [ others ].
3. Click [ software version (VER) ].
4. Click [ Send ] button. (Returned value is software Version. ) G) Test Command "get RSSI low (RSL)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ get RSSI low (RSL) ].
4. Click [ Send ] button. (Returned value is RSSI low value and that is written to flash ROM. ) H) Test Command "get RSSI high (RSH)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ get RSSI high (RSH) ].
4. Click [ Send ] button. (Returned value is RSSI high value and that is written to flash ROM. ) I) Test Command "eeprom read (EPR)"
1. Click [ Command menu ] button.
2. Point [ memory access ].
3. Click [ eeprom read (EPR) ].
4. Set parameters as follows.
•First parameter : address No. (2 byte) : 5286
•Second parameter : Length ("1"-"10"(Hex)) : 2
5. Click [ Send ] button. (Returned value is RSSI low value and RSSI high value. ) J) Test Command "set modulaton (SMR)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ set modulation (SMR) ].
4. Set the value to the first parameter.
5. Click [ Send ] button. (if returned value is "OK", It succeeded. )
*Please adjust this value until the modulation reaches a value closest to ± 375kHz.
17
KX-TDA0155CE
6.3.2. Input The Command Directly Menu
- Example of Operation -
1. Click [test command] tag.
2. Input the command and parameter (if necessary) directly to the [command] box. (Don't set paramter to the [parameter] box. )
(in case of test command "RFC")
Loading...