1 INTRODUCTION
1.1. INSULATION RESISTANCE TEST
Change from original page 3 (1.2. INSULATION RESISTANCE TEST )
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part (screw
heads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
The equipment should be repaired and rechecked before it is returned to the customer.
2
KX-F206TW
1.2. SPECIFICATIONS
Change from original page 7 (1.8. SPECIFICATIONS)
Applicable Lines: Public Switched Telephone Network
Document Size: Max. 216 mm (8 1/2”) in width
Max. 600 mm (23 5/8”) in length
Effective Scanning Width: 208mm (8 3/16”)
Recording Paper Size: 216 mm max. 30 m (8 1/2”×98”) roll
Effective Printing Width: 208 mm (8 3/16”)
Transmission Time*: Approx. 15 s/page (Original mode)**
Approx. 30 s/page (G3 Normal mode)
Scanning Density: Horizontal:
8 pels/mm (203 pels/inch)
Vertical:
3.85 lines/mm (98 lines/inch)—STANDARD mode
7.7 lines/mm (196 lines/inch)—FINE/HALF TONE mode
15.4 lines/mm (392 lines/inch)—SUPER FINE mode
Halftone Level: 64-level
Scanner Type: Contact Image Sensor (CIS)
Printer Type: Thermal Printing
Data Compression System: Modified Huffman (MH), Modified READ (MR)
Modem Speed: 9,600 / 7,200 / 4,800 / 2,400 bps; Automatic Fallback
Operating Environment: 5°C—35°C (41°F—95°F), 45 %—85 % RH (Relative Humidity)
Dimensions (H×W×D): 122 mm × 338 mm × 240 mm (4 13/16” × 13 5/16” × 9 7/16”)
Mass (Weight): Approx. 2.5 kg (5.5 lb.)
Power Consumption: Standby: Approx. 6.0 W
Transmission: Approx. 16 W
Reception: Approx. 22 W (When receiving the CCITT No. 1 Test Chart)
Copy: Approx. 22 W (When copying the CCITT No. 1 Test Chart)
Maximum: Approx. 120 W (When copying a 100 % black document)
Power Supply: 110 V AC, 60 Hz
* Transmission speed depends upon the contents of the pages, resolution, telephone line conditions and capability of the other
party´s machine.
** The 15 second speed is based upon the CCITT No. 1 Test Chart.
Note:
· Any details given in these instructions are subject to change without notice.
· The pictures and illustrations in these instructions may vary slightly from the actual product.
3
KX-F206TW
1.3. LOCATION OF CONTROLS
1.3.1. CONTROL PANEL
Change from original page 9 (1.11.2. CONTROL PANEL)
4
1.4. CONNECTIONS
Change from original page 10 (1.12. CONNECTIONS)
NOTE
When you operate this products, the power outlet should be near the product and easily accessible.
KX-F206TW
5
KX-F206TW
2 TROUBLESHOOTING GUIDE
2.1. Program Mode Table
Change from original pages 52, 53 ([2. Program Mode Table] in 2.3.4.2.2. Remote Programming)
Code Function Set Value Default Remote setting
001 Set the date and time mm/dd/yy hh:mm AM/PM --------- NG
002 Your logo --------- --------- NG
003 Your fax number --------- --------- NG
004 Print transmission report 1:ERROR 2:ON 3:OFF ERROR OK
007 FAX ring count 1 to 4 rings 1 ring OK
013 Dialing mode 1:PULSE/2:TONE TONE OK
022 Journal auto print 1:ON 2:OFF ON OK
023 Overseas mode 1:ON 2:OFF OFF OK
025 Delayed send ON/OFF OFF NG
030 Silent FAX recognition ring 3 to 9 rings 3 rings OK
031 Ring detection 1:A/2:B/3:C/4:C/5:D/6:OFF OFF OK
041 FAX activation code ON/OFF ON/ID=*9 NG
046 Friendly reception 1:ON 2:OFF ON OK
049 Auto disconnect 1:ON 2:OFF ON --------058 Original setting 1:NORMAL/2:LIGHT/3:DARKER NORMAL OK
070 FAX pager call ON/OFF OFF NG
076 Connecting tone 1:ON 2:OFF ON OK
077 Auto answer mode 1:FAX ONLY/2:TEL/FAX FAX ONLY OK
078 TEL/FAX delay ring 1 to 4 rings 1 OK
080 Set default YES/NO NO NG
501 Pause time 001~600 X 100 ms 050 OK
502 Flash time 01~99 X 10 ms 70 OK
503 Dial speed 1:10pps 2:20 pps 10 OK
520 CED frequency 1:2100Hz 2:1100Hz 2100 OK
521 International mode 1:ON 2:OFF ON OK
522 Auto standby 1:ON 2:OFF ON OK
523 RCV EQL. 1:ON 2:OFF OFF OK
524 SND EQL. 1:ON 2:OFF OFF OK
544 Document feed position adjustment value set 01~99 step 50 OK
550 Memory clear Press "START". --------- NG
551 ROM check Press "START". --------- NG
553 Monitor on FAX communication select 1:OFF 2:P-B 3:ALL OFF OK
554 Modem test Press "START". --------- NG
555 Scanner test Press "START". --------- NG
556 Motor test Press "START". --------- NG
557 LED test Press "START". --------- NG
558 LCD test Press "START". --------- NG
559 Document jam detection select 1:ON 2:OFF ON OK
561 Key test Press any key. --------- NG
563 CCD position adjustment value set 00~30 mm --------- OK
570 Break % select 1:61% 2:67% 67% OK
571 ITS auto redial time set 00~99 01 OK
572 ITS auto redial line disconnection time set 001~999 set 065 OK
573 Remote turn-on ring number set 01~99 15 OK
590 FAX auto redial time set 00~99 02 OK
591 FAX auto redial line disconnection time set 001~999 065 OK
592 CNG transmit select 1:OFF/2:ALL/3:AUTO ALL OK
593 Time between CED and 300 bps 1:75/2:500/3:1s 75 ms OK
594 Overseas DIS detection select 1:1st/2:2nd 1st OK
595 Receive error limit value set 001~999 100 OK
596 Transmit level set 15~00dBm -11 OK
598 Modem sesitivity 20~48 45 OK
717 Transmit speed select 1:9600/2:7200/3:4800/4:2400bps 9600bps OK
718 Receive speed select 1:9600/2:7200/3:4800/4:2 400bps 9600bps OK
719 Ringer off in TEL/FAX mode 1:ON/2:OFF ON OK
721 Pause tone detect 1:ON/2:OFF ON OK
722 Redial tone detect 1:ON/2:OFF ON OK
763 Friendly reception CNG detection select 1:10S/2:20S/3:30S 20S OK
771 T1 timer 1:35 sec/2:60 sec 35 sec OK
774 T4 Timer 00~99 (X100ms) 00 OK
815 Sensor check Press "START". --------- NG
6
KX-F206TW
Code Function Set Value Default Remote setting
844 Original setting 1:NORMAL/2:LIGHT/3:DARKER NORMAL OK
991 Transmit basic list 1: START --------- OK
992 Transmit advanced list 1: START --------- OK
994 Transmit journal report 1: START --------- OK
996 Journal 3 1: START --------- OK
999 Transmit service list 1: START --------- OK
OK : Can set the value by the remote programming feature or print a list.
NG : Cannot set the value.
Note:
Note: Refer to 2.4.4. SERVICE FUNCTION TABLE for descriptions of the individual codes.
For example, the "004 Transmission report mode" set value "1:ERROR/2:ON/3:OFF" number corresponds to the number dialled.
7
KX-F206TW
2.2. Power Supply Board Section
Change from original pages 65~67 (2.3.4.5. Power Supply Board Section)
1. Key components for troubleshooting
The following components have been known to break frequently:
F101, D101-D104, C109, Q101, PC101, ZD203, R302.
This comes from our experience with experimental tests. For example: power supply,
lightning surge voltage test, withstanding voltage test, intentional short circuit test, etc.
Caution:
If you find a melted fuse in the unit, don’t turn the power on without repairing the unit first. (Except for the fuse.)
If you do, the fuse will melt again and the unit has not been repaired. The problem exists somewhere else.
In most cases, (our experience) the symptom is that nothing is output.
There is a high possibility in the primary side more than the secondary side.
8
2. Troubleshooting Flow Chart
KX-F206TW