Panasonic GXL-8FUB Installation Manual

INSTRUCTION MANUAL
Inductive Proximity Sensor
Front sensing
GXL-8FUغ
I/O CIRCUIT DIAGRAMS
1
(Brown) Output
r
T
Sensor circuit
Internal circuit Users' circuit
Symbols...ZDTr: Surge absorption zener diode
Note: The maximum load
current varies depend­ing on the ambient temperature.
Conditions for the load
(1)
The load should not be actuated by the leakage current (0.8mA) in the OFF state.
(2)
The load should be actuated by (supply voltage - 3V) in the ON state.
(3)
The current in the ON state should be between 3 to 70mA DC.
In case the current is less than 3mA, connect a bleeder resistance in parallel to the load so that a current of 3mA, or more, flows.
CAUTIONS
2
٨
If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
٨
Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction.
٨
Do not use during the initial transient time (50ms) after the power supply is switched on.
٨
Extension up to total 50m is possible with a 0.3mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible.
SENSING RANGE
3
٨ Please use it by 1.8mm or less.
However, this value is a value over a standard detection object (iron 1515t1mm). With a non-fer­rous metal, the sensing range is obtained by multiplying with the correction coefficient specified on the right.
This bag is a product made from polyethylene. Even if it burns, harmful gas is not generated.
3V in ON state
Z
D
(Blue) 0V
: PNP output transistor
Max. load
DC 2-wire Type
Top sensing
GXL-8HUغ
Bleeder resistanceColor code
Load
Load
70
35
3
current (mA)
-25 55 70
Ambient temperature ()
+
-
3 to 70mA in ON state (Note)
0.8mA in OFF state
Correction coefficient
Sensing object
Iron
Stainless steel (SUS304)
Brass
Aluminum
12 to 24V DC r10%
Correction coefficient
1
0.82 approx.
0.59 approx.
0.57 approx.
٨٨Keep in mind that detection distance becomes short when a
detection object is small. Further, the sensing range also changes if the sensing object is plated.
MOUNTING
4
٨
Do not use a washer between the sensor and the mounting screw. The tightening torque should
٨
be 0.5Nm or less. To mount the sensor with a
٨
nut, the thru-hole diameter should be Ǿ3.4mm. With the attached mounting screw and nut, take care that the thick­ness of the mounting plate should be 2.3mm or less.
٨
If a screw other than the at­tached screw to use a M3 truss head screw.
Do not use a flat head screw or a pan head screw.
٨࡮Influence of surrounding metal
When there is a metal near the sensor, keep the minimum separation distance specified below. Refer to the figures shown on the reverse side.
GXL-8FUš GXL-8HUš
7mm
٨࡮Mutual interference prevention
When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference. Refer to the figures shown on the reverse side.
Between 'I' type and non 'I' type Between two 'I' types or two non 'I' types
Note: Close mounting is possible for up to two sensors. When mount-
ing three sensors or more, at an equal spacing, in a row, the minimum value of dimension 'H' should be 2mm.
SUNX Limited
M3 (length 12mm) truss head screw (Accessory)
MS-GXL8-4
(Accessory)
M30.5mm tapped hole (Depth: 8mm or more) or Ǿ3.4mm thru-hole
11.5mm If mounting using
nut and washers (Accessories)
Ǿ2.4mm hole (Depth: 3mm or more)
A
B
C
D
E
8mm
Head office: 2431-1 Ushiyam-cho, Kasugai-shi,
Overseas Sales Dept.: Phone: +81-(0)568-33-7861
3mm
4mm
10mm
0mm (Note)
12mm
Aichi, 486-0901,Japan Phone: +81-(0)568-33-7211
F
3mm
H
PRINTED IN JAPAN
G
3mm
J 15mm 30mm