SPECIFICATIONS PRECAUTIONS FOR PROPER USE
DIMENSIONS (Unit: mm)
Item
Applicable amplifier
Sensing range
Sensing object
Allowable bending radius
Fiber cable length (Free-cut)
Protection
Ambient temperature
Ambient humidity
Accessories
FX-D1 series (Note)
1,500mm
"4mm or more opaque object
R25mm or more
Equivalent to IP67 (except for the cut ends of the fiber)
0 toⳭ60⬚C (No dew condensation or icing allowed),
Storange: 0 toⳭ60⬚C
35 to 85%RH, Storage: 35 to 85%RH
Fiber core: Acrylic, Sheath: PFA
Enclosure: PFA
FX-CT1 (Fiber cutter): 1 No.
FT-Z802Y FT-Z805Y FT-Z807Y
2m 5m 7m
2m type 5m type 7m type
• Keep the fiber head surface intact. If it is scratched or
spoiled, the detectability will deteriorate.
• If the fiber head surface is dirty, wipe the off the dirt with a
clean soft cloth moistened with water.
• Do not use the fiber head surface in places where it may
come in direct contact with water. A water drop on the
fiber head surface deteriorates the sensing. No dew or
liquid drop is present on surface of fiber head surface or
sensing object.
• Do not apply excessive tensile force of the fiber cable.
• Bending radius of the fiber cable must be R25mm or more.
If the bending radius is smaller than the specified value,
the sensing performance may deteriorate.
• Ensure that any strong extraneous light is not incident on
the receiving face of the fiber head.
• The fiber cables should be cut off at the ends with the fiber
cutter FX-CT1(accessory) before insertion into the
amplifier. Carefully cut and connect the fiber, as the
sensing performance may deteriorate depending on the
conditions of the cut part and/or of the connection to the
amplifier.
Cautions
(1)
3
(7.3)
2-"3.2
6
13
(5.8)
2,000 (FT-Z805Y: 5,000, FT-Z807Y: 7,000)
15
4 7.5
7
"2.2
M3 screws
(Please arrange separately.)
• Mount using M3 screws. The tightening torque should be
0.3N 䡠 m or less.
Mounting
Beam axis
Fiber cable
Fiber head
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
Type
Model No.
Material
Note: For further details, refer to FX-D1 series catalog or sensor general
catalog for FX-D1 series.
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-(0)568-33-7211
FAX: +81-(0)568-33-2631
SUNX Limited
Phone: +81-(0)568-33-7861
FAX: +81-(0)568-33-8591
Overseas Sales Dept.
Printed on 100% recycled paper
PRINTED IN JAPAN
http://www.sunx.co.jp/