Panasonic FR-WKZ11 User Manual

FR-WKZ11
RETROREFLECTIVE WITH POLARIZING FILTERS FIBER
Unaffected by surface reflection from transparent objects
FR-WKZ11 has a built-in polarizing filters in its tip, so that it is
unaffected by surface reflection from transparent objects and specular objects directly in front of it.
Because it’s a retroreflective type, light passes through transparent objects twice, so differences in light amount can be easily picked up and glass substrate and transparent films can be detected with good stability.
Because stable sensing is made possible at a long range, transparent objects (glass substrates and the like) can be detected through a view port.
Compact head and long sensing range
This fiber has a compact head of W9.5H5.2D15 mm W0.374H0.205
D0.591 in. Equipped with sharp bending fibers (Allowable bending radius:
R1 mm R0.039 in) making it space efficient. It is a retroreflective type with a polarizing filters that has a long sensing range of 3,200 mm 125.984 in.
Even glass substrates can be accurately detected.
Because the reflected light from the transparent object returns oscillating in the same direction as the incident light, it does not pass through polarizing filter B.
Long sensing range
Longest in the industry
Space-saving
When using RF-230 Reflector (optional) Sensing range:
3,200 mm 125.984 in
When using RF-13 Reflective tape (accesory) Sensing range:
800 mm 31.496 in
Allowable bending radius: R1 mm R0.039 in
m
Sensing range values determined with the amplifier in LONG mode. Unstable detection may result if setting the fiber to detect objects passing within 0 to 100 mm 0 to 3.937 in from the fiber head.
9.5 mm
0.374 in
5.2 mm
0.205 in
15 mm
0.591 in
Reflector
Beam-emitting fiber
Polarizing filter A
Polarizing filter B
The surface reflection light of the view port facing the fiber is not received.
Light passing through polarizing filter A is changed the direction of polarization by a reflector and polarizing filter B only lets in beam whose wavelengths run horizontally.
Transparent object (glass substrate etc.)
Stable sensing of transparent objects
Beam­receiving fiber
Beam­receiving fiber
Polarizing filter B
Beam-emitting fiber
Polarizing filter A
No. PCE-FRWKZ11 July, 2003
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631
SUNX Limited
Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591
Overseas Sales Dept.
http://www.sunx.co.jp/
All information is subject to change without prior notice.
RF-13
FR-WKZ11
SPECIFICATIONS
DIMENSIONS (Unit: mm in)
SENSING CHARACTERISTICS (TYPICAL)
Applicable amplifiers (Note 1
)
Min. sensing object (Note 6) Allowable bending radius Fiber cable length
Ambient temperature Ambient humidity (Note 7)
Weight
Sensing range
(RF-13)
(Note 2, 3) Sensing range when detecting a
glass substrate (reference)(Note 3, 5)
Fiber Fiber head
Type
Model No.
Accessories
Material
Item
Retroreflective with polarizing filters fiber
FR-WKZ11
FX-301/302/303/311 series
FX-AT3 (Fiber attachment for "2.2 mm "0.087 in fiber): 1 set FX-CT2 (Fiber cutter): 1 pc., MS-FD-2 (Fiber mounting bracket) RF-13 (Reflective tape): 1 pc.
100 to 3,200 3.937 to 125.984 (LONG), 100 to 2,000 3.937 to 78.740 (STD) 100 to 1,600 3.937 to 62.992 (FAST), 100 to 1,000 3.937 to 39.370 (S-D) 100 to 2,400 3.937 to 94.488 (LONG), 100 to 1,300 3.937 to 51.181 (STD) 100 to 1,000 3.937 to 39.370 (FAST), 100 to 600 3.937 to 23.622 (S-D) 100 to 1,100 3.937 to 43.307 (LONG), 100 to 700 3.937 to 27.559 (STD) 100 to 550 3.937 to 21.654 (FAST), 100 to 300 3.937 to 11.811 (S-D)
RF-230
RF-220
RF-210
PRECAUTIONS FOR PROPOSER USE
This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal object detection sensor.
Keep the fiber head surface intact. If it is scratched or spoiled, the detectability will deteriorate.
If the sensing surface gets dirty, wipe dirt or stains from the sensing faces with a soft cloth. (Do not use organic solvents.)
Ensure that any strong extraneous light is not incident on the receiving face of the fiber head.
Do not apply excessive tensile force to the fiber cable. (The tensile force should be 20 N or less.)
Take care that the fiber is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance.
Avoid areas prone to vapor or dust as well as corrosive gas environments. Do not expose the sensor directly to water or chemicals.
Take care that the fiber does not come in direct contact with organic solvents, such as, thinner, etc.
Mounting
Cautions
Use M3 or less set screws (cup point), and affix the head within 15 mm 0.591 in from the tip of the fiber head. Do not exceed a torque of 0.3 Nm when tightening.
If not using the attached mounting bracket
The head can be affixed even without using the set screws together.
If using the set screws together, use M3 set screws (cup point) to affix and do not exceed a torque of 0.05 Nm when tightening.
If using the attached mounting bracket
Notes: 1)
2)
3)
4)
5)
6)
7)
Refer to the sensor general catalog 2003-2004, catalog of each amplifier (FX-301/311 series) or dedicated homepage for fiber sensor (http://www.fiber­sensor.com) for details about the applicable amplifier.
The sensing ranges are the values for red LED type amplifier (excluding FX-303). The sensing range and sensing range when detecting a glass substrate are the possible
setting range for the reflector or the reflective tape. The fiber can detect an object less than 100 mm 3.937 in away. However, if setting the fiber to detect objects passing within 0 to 100 mm 0 to 3.937 in from the fiber head, unstable detection may result.
FX-311(P) does not have a FAST mode. The sensing range when detecting a glass substrate are the values for red
LED type amplifier (excluding FX-303) at STD mode. The sensing range is specified for t0.7 mm 0.028 in glass substrate for LCD.
The minimum sensing object value is the value for red LED type under optimum conditions. The optimum condition is the condition when the sensivity is set so that the sensing output just changes to light incident operation in the object absent condition.
If using the fiber with a reflector (RF-230/220/210), changes in the ambient humidity level may lead to fluctuations in the amount of incident light. Exercise caution when using the fiber set to low differences in light amount. If using the fiber in an area prone to significant changes in ambient humidity level, we recommend the RF-13.
1
0.039
2,000
78.740
15
0.591
(20)
(0.787)
(20)
(0.787)
5.2
0.205
4.6
0.181
9.5
0.374
"2.2 "0.087
("3.2 "0.126) Model No. tube (PVC)
("3.2 "0.126) Model No. tube (PVC)
9.5
0.374
4.6
0.181
5.2
0.205
2-M30.5 0.020
Fiber mounting bracket [Cold rolled carbon steel (SPCC) zinc chromate plated]
10
0.394
12.6
0.496
14
0.551
4
0.157
3.3
0.130
3.3 0.130
4 0.157
t 1.4
t 0.055
6.2
0.244
7 0.276
5
0.197
Glass lens (BK7)
Glass lens (BK7)
"2.2 "0.087
Enclosure (PC)
Enclosure (PC)
1
0.039
2,000
78.740
15
0.591
Mounting drawing with the fiber mounting bracket (MS-FD-2)
100 to 800 mm 3.937 to 31.496 in (LONG), 100 to 570 mm 3.937 to 22.441 in (STD) 100 to 500 mm 3.937 to 19.685 in (FAST)(Note 4), 100 to 350 mm 3.937 to 13.780 in (S-D)
35 to 85 %RH, Strage: 35 to 85 %RH
Fiber core: Acrylic, Sheath: Polyethylene
Enclosure: Polycarbonate, Lens: Crown glass (BK7)
15 g
Approx.
"0.3 mm "0.012 in opaque object
R1 mm R0.039 in or more
2 m 6.562 ft free cut
Along sensing axis: 6 mm 0.236 in or less Perpendicular to sensing axis: 1.2 mm 0.047 in or less
Sensing range when using a reflector (optional)(mm in)
Fiber
Reflective tape
30 1.181
0.5
0.020
Rear surface (pressure-sensitive adhesive)
Reflective surface (Acrylic)
30
1.181
100 to 280 mm 3.937 to 11.024 in (RF-13), 100 to 1,000 mm 3.937 to 39.370 in (RF-230)
A
A
"1 "0.039
Multi-core fiber "0.075 "0.003151
View A
50
1.969
050
1.969
100
3.937
0
500
19.685
1,000
39.370
500
19.685
1,000
39.370
S-D
FAST
STD
LONG
L
Reflective tape (RF-13)
?
Center Down Up
Operating point # (mm in)Operating point # (mm in)
Center Left Right
100
3.937501.969
050
1.969
100
3.937
100
3.937
0
Setting distance L (mm in)
Setting distance L (mm in)
S-D
FAST
STD
LONG
L
Reflective tape (RF-13)
?
Parallel deviation
Vertical directionHorizontal direction
Repeatability
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
25 to 55 C 13 to 131 F (No dew condensation or
icing allowed), Strage: 25 to 55 C 13 to 131 F