Panasonic DP-100L User guide

2 PROCESS DATA(PD)
INSTRUCTION MANUAL
DP-100L Series INDEX LIST
IMJE-DPLINDEX No.0061-91V
IO-Link setting file (IODD) can be downloaded from our website ( http://panasonic.net/id/pidsx/global ).
1 PHYSICAL LAYER
Model No.
Baud rate COM3(230.4kbps)
Minimum cycle time 1ms
Process data length 4byte
Vendor ID 834
Device ID 0x060000 0x060001
3 SERVICE DATA(SD)
Index Sub index Name R/W
2 0 System-Command W UInteger 1byte
12 0 Device Access Locks R/W Record 2byte 0
16 0 Vendor Name R String 64byte
17 0 Vendor Text R String 64byte
18 0 Product Name R String 64byte
19 0 Product ID R String 64byte
20 0 Product Text R String 64byte
21 0 Serial Number R String 16byte
22 0 Hardware Version R String 8byte
23 0 Firmware Version R String 8byte
24 0 Application Specic Tag R/W String 32byte
37 0 Detailed Device Status R UInteger 12byte
40 0 Process-Data Input R UInteger 4byte
60
61
63
66 0 Response Time Setting of Output R/W UInteger 1byte 1
80 0 ECO Setting R/W UInteger 1byte 0
DP-101ZL3-M-P-□DP-102ZL3-M-P-
1 Threshold Value Setting 1 R/W Integer 2byte
2 Threshold Value Setting 2 R/W Integer 2byte
Output Operation Setting of C/Q
1
Output
Sensing Output Setting of C/Q
2
Output
3 Hysteresis Setting of C/Q Output R/W Integer 2byte 3 Hysteresis value 8-step setting : 1 to 8
Output Operation Setting of DO
1
Output
Sensing Output Setting of DO
2
Output
3 Hysteresis Setting of DO Output R Integer 2byte Linkage with Index61_3
Back up target
R/W UInteger 1byte
R/W UInteger 1byte 0x01
R UInteger 1byte Linkage with Index61_1
R UInteger 1byte Linkage with Index61_2
PD0 Upper byte of pressure data
PD1 Lower byte of pressure data
Scale
PD2
0 (1kPa)
PD3
bit
7 6 5 4 3 2 1 0
Format
Data length Default data
7 6 5 4 3 2 1 0
DP-101ZL3-M-P­DP-102ZL3-M-P-
□ : -1 (0.1kPa) □ : -3 (0.001MPa
Assignment Remarks
Control output
(DO)
Fixed
Fixed
Fixed
Fixed
Information
notication
Error level
DP-101
□:
-500 (-50.0)
DP-102
□:
0500 (0.500)
DP-101
□:
-495 (-49.5)
DP-102
□:
0505 (0.505)
DP-101□
:1
DP-102□
:0
bit
0 : OFF 1 : ON
0
0
0
0
0 : No notication 1 : Notied
0 : Normal 1 : Caution 2 : Fault
Description of settings
0x82 : Reset setting 0xA0 : Zero-adjustment setting 0xA1 : Remote zero-adjustment setting 0xA2 : Zero-adjust setting unset 0xA3 : Auto-reference setting
Local User InterFace Lock 0 : UnLock , 8 : Lock Main unit : Linked with key lock
Threshold value of EASY mode Low-side threshold value of window comparator mode / hysteresis mode
DP101
□ : -1010 to 1010 0xFC0E to 0x03F2
DP102
□ : -101 to 1010 0xFF9B to 0x03F2
High-side threshold value of window comparator mode / hysteresis mode
DP101
□ : -1010 to 1010 0xFC0E to 0x03F2
DP102
□ : -101 to 1010 0xFF9B to 0x03F2
0 : N.O. 1 : N.C.
0x01 :
EASY mode 0x02 : Hysteresis mode 0x03 : Window comparator mode
1 : 2.5ms 2 : 5ms 3 : 10ms 4 : 25ms 5 : 50ms
0 : Normal operation (ECO mode is OFF) 1 : Dimming mode (Std : The display becomes dark)
3 : O󰀨 mode (
6 : 100ms 7 : 250ms 8 : 500ms 9 : 1,000ms A : 5,000ms
FULL : The display is turned OFF
Index Sub index Name R/W
Display Color Setting of Main-
1
display Selection
Display Setting of Sub-display
2
82
83 0 Pressure Unit Set R/W UInteger 1byte
84
85 0 Zero-adjust R UInteger 1byte
163 0 Operating Time R UInteger 4byte Operating time per 1-hour unit [h]
164 0 Number of Data Save Operations R UInteger 4byte
168 0 Notication Flag Setting R/W UInteger 1byte
169 0 Notication Event Code R UInteger 2byte Newest event code readout
Selection
3 Display Speed Set R/W UInteger 1byte 0
4 Peak / Bottom Hold Set R/W UInteger 1byte 0
1 No** Display Set R/W String 2byte 01 Two half-width numeric characters : 01 to 99
2 Custom Display Set R/W String 4byte AAAA
Back up target
R/W UInteger 1byte 0
R/W UInteger 2byte 0
Format
Data length Default data
DP-101 DP-102
Description of settings
0 : Red when ON,Green when OFF 1 : Green when ON,Red when OFF 2 : Always red 3 : Always green
0 : Std (Displays threshold) 1 : OFF (Displays nothing) 2 : Unit (Presently selected pressure unit is displayed) 3 : No** (Desired No. can be shown) 4 : Cust (
Desired numbers, alphabets and signs
can be shown
0 : 250ms 1 : 500ms 2 : 1000ms
0 : OFF 1 : ON
1 : MPa (This cannot be selected in the case of
□ : 2
DP-101
□ : 1
2 : kPa
Four half-width alphanumeric characters * Error is generated if any of the following characters is entered. T , j , k , m , p , s , x
0 : Not executed 1 : In execution
Increments each time setting data is stored in the nonvolatile memory.
0 : Notify 1 : Do not notify
)
□)
4 EVENT FUNCTION
Error indication
Display of measured value 0x8D00
Display of measured value 0x8D01
)
Event code
0x7710
0x8CB0
0x8CB1
0x1811
Error level
Fault
Normal
Normal External input outside the rated pressure range
Caution
Caution
Short circuit overcurrent
Pressure applied during zero-adjustment
Fault
Pressure element abnormality
Operating time exceeded
Max. number of the nonvolatile memory save opera-tions exceeded
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head O󰀩ce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2018
State
Information notication
PRINTED IN JAPAN