Panasonic D10000, PT-DW10000 User Manual

Panasonic Projector RS-232C Control Specifications
P T- D W 1 0 0 0 0 / D 1 0 0 0 0
t
Using the Serial Terminals
1. Basic Forma
Transmission f rom the co mpute r begins wi th STX, t hen the ID , comman d, para mete r, and ETX are se nt i n this order. Add parameters ac cording to the details of control.
Basic control command (without parameter)
Start
(STX)
ID Separator
Command End
(semicolon)
(ETX)
1 byte 4 bytes 1 byte 3 bytes 1 byte
Basic control command (with parameters)
Start
(STX)
ID Separator
Command Separator
(semicolon)
Parameters End
(colon)
1 byte 4 bytes 1 byte 3 bytes 1 byte Undefined length 1 byte
ID of the basic control command
ID 4 bytes
String
ALL ADZZ ID23 AD23 ID46 AD46 Group E AD0E ID1 AD01 ID24 AD24 ID47 AD47 Group F AD0F ID2 AD02 ID25 AD25 ID48 AD48 Group-G AD0G ID3 AD03 ID26 AD26 ID49 AD49 Group H AD0H ID4 AD04 ID27 AD27 ID50 AD50 Group I AD0I ID5 AD05 ID28 AD28 ID51 AD51 Group J AD0J ID6 AD06 ID29 AD29 ID52 AD52 Group K AD0K ID7 AD07 ID30 AD30 ID53 AD53 Group L AD0L ID8 AD08 ID31 AD31 ID54 AD54 Group M AD0M ID9 AD09 ID32 AD32 ID55 AD55 Group N AD0N ID10 AD10 ID33 AD33 ID56 AD56 Group O AD0O ID11 AD11 ID34 AD34 ID57 AD57 Group P AD0P ID12 AD12 ID35 AD35 ID58 AD58 Group Q AD0Q ID13 AD13 ID36 AD36 ID59 AD59 Group R AD0R ID14 AD14 ID37 AD37 ID60 AD60 Group S AD0S ID15 AD15 ID38 AD38 ID61 AD61 Group T AD0T ID16 AD16 ID39 AD39 ID62 AD62 Group U AD0U ID17 AD17 ID40 AD40 ID63 AD63 Group V AD0V ID18 AD18 ID41 AD41 ID64 AD64 Group W AD0W ID19 AD19 ID42 AD42 Group A AD0A ID20 AD20 ID43 AD43 Group B AD0B ID21 AD21 ID44 AD44 Group C AD0C ID22 AD22 ID45 AD45 Group D AD0D
ID 4 bytes
String
ID 4 bytes
String
ID 4 bytes
Group X AD0X Group Y AD0Y Group Z AD0Z
(ETX)
String
2/62
Response (Callback) of the basic control command
In the period when commands can be accepted Differs according to each command.
In the period when commands cannot be accepted
Hexadecimal 02h 45h 52h 34h 30h 31h 03h
Character E R 4 0 1
In case of the parameter error
Hexadecimal 02h 45h 52h 34h 30h 32h 03h
Character E R 4 0 2
Notes when two or more projec tors are use d
• Make the co mm unicati on conditi o ns th e s am e b etwe en o utput /i nput. I N an d O UT c an be i nd epe nde ntly set respectivel y. (When you set RS -422 OUT of th e first projecto r to 38 400 bps, set RS- 422 IN of the second projector to 38 400 bps.)
• Make only one in VPS SYSTEM MASTER and make all of the remainder VPS SYSTEM SLAVE.
• Set ID number different in each projector.
• I/O to RS-422 OUT is not done during MAIN POWER OFF. Turn on MAIN POWER of all projectors.
• Make onl y one of the each group in GRO UP MASTER and make all the remainder-GROUP SLAVE.
Attention:
• No command may be sent or received for 1 0 to 60 sec onds after th e lamp sta rts lighting. Try sending any command after tha t period has elapsed.
• When sendin g sev e ral co mm ands, be s ure to w ait f or a res pons e f rom the p rojector, and send the next command after 0.5 seco nds or more pass.
• It might take time by the time the response returns because the command is processed in the projector. Set the time-out to ten seconds or more.
Notes:
• This projector will respond to the computer only in the following cases:
If the sent ID coincides with the projector ID, VPS SYSTEM in RS232C settings of this projector is MASTER and the sent ID is ALL, or If-Group (A—Z) of the sent ID coincides with GR OUP in RS232C settings of this projector and
GROUP in RS232C settings of this projector is MASTER.
• When the command is received during STNDBY , this projector returns the receiving command as it is as a response (callback) if it is in the period when the concerned command cannot be accepted.
• Each setting/query command concerning P IN P controls to information on the user being set by current P IN P setting. Therefore, ER401 is returned as a response (callback ) when P IN P setting is OFF.
3/62
2. Basic Control Command
Explanatory not es
Yes: Enable No: Disable
2.1. Powe r ON (Lamp O N)
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 50h 4Fh 4Eh 03h
Character A D Z Z ; P O N
Response (Callback)
In the period when the command can be accepted (This command in power-on condit ion is included)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P O N
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes Yes Yes Yes Yes (Yes)
Notes:
• When you confirm whether to have succeeded in power-on, confirm it by QPW (query power condition) command after receiving the callback of PON command.
• When REMOTE2 is effective, ER401 is returned as a response (callback) .
2.2. Power OFF (Standby)
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 50h 4Fh 46h 03h
Character A D Z Z ; P O F
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes Yes Yes Yes Yes (Yes)
Notes:
• When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after receiving the callback of PO F command.
• When REMOTE2 is effective, ER401 is returned as a response (callback) .
2.3. AUTO SETUP
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 53h 03h
Character A D Z Z ; O A S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 53h 03h
Character O A S
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No No No Yes
Note:
• This command is acceptable only when RGB1 or RGB2 is selected and RGB PC signals are input. In other cases, ER401 is returned.
2.4. SHUTTER
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 48h 3Ah *1 03h
Character A D Z Z ; O S H : *2
Paramet ers (* 1, *2)
Shutter OFF Shutter ON Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 48h 3Ah *1 03h
Character O S H : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No Yes Yes Yes (Yes)
Note:
• The setting by REMOTE2 is given to priority. When a command different from the setting of REMOTE2 is sent, ER402 is returned.
4/62
2.5. Input Change
Hexadecimal
Character A D Z Z ; I I S : *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
RGB1 RGB2 Hexadecimal 52h 47h 31h 52h 47h 32h
Character R G 1 R G 2 VIDEO S-VIDEO Hexadecimal 56h 49h 44h 53h 56h 44h
Character V I D S V D DVI AUX Hexadecimal 44h 56h 49h 41h 55h 58h
Character D V I A U X
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 49h 49h 53h 3Ah *1 *3 *5 03h
Character I I S : *2 *4 *6
Acceptability
SECURITY
Yes No Yes Yes Yes (Yes)
Notes:
• REMOTE2 is given to priority . Calls back ER402 if the input select of REMOTE2 is avail able.
• When AUX is specified for the parameter with incompatibl e input modul e installed in the slot, ER401 i s ret urned.
• When AUX is specified for the parameter with no input module installed in the slot, ER402 is returned.
2.6. TEST PATTERN
Hexadecimal
Character A D Z Z ; O T S : *2 *4
Paramet ers (* 1, *2, *3 , *4 )
Hexadecimal 30h 30h 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 0 0 1 0 2 0 3 0 4
Hexadecimal 30h 35h 30h 36h 30h 37h 30h 38h 31h 30h
Character 0 5 0 6 0 7 0 8 1 0
Hexadecimal 31h 31h 32h 31h 32h 32h 32 33 32h 34h
Character 1 1 2 1 2 2 2 3 2 4
Hexadecimal 32h 35h 32h 36h 32h 38h 32h 39h 33h 30h
Character 2 5 2 6 2 8 2 9 3 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 54h 53h 3Ah *1 *3 03h
Character O T S : *2 *4
Acceptability
SECURITY
Yes No Yes Yes Yes Yes
2.7. ON SCREEN
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 4Fh 53h 3Ah *1 03h
Character A D Z Z ; O O S : *2
Paramet ers (* 1, *2)
Shutter OFF Shutter ON Hexadecimal
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 4Fh 53h 3Ah *1 03h
Character O O S : *2
Acceptability
SECURITY
No No Yes No Yes Yes
Note:
• When the display setting of SECURITY is not OFF, ER401 is returned.
02h 41h 44h 5Ah 5Ah 3Bh 49h 49h 53h 3Ah *1 *3 *5 03h
STNDBY NO SIGNAL SHUTTER TEST PAT TERN REMOTE2
02h 41h 44h 5Ah 5Ah 3Bh 4Fh 54h 53h 3Ah *1 *3 03h
OFF White Black Flag Reversed flag
Window Reversed
Ramp White Red Green Blue
10% brightness
(White)
STNDBY NO SIGNAL SHUTTER TEST PAT TERN REMOTE2
30h 31h
STNDBY NO SIGNAL SHUTTER TEST PAT TERN REMOTE2
window
5% brightness
(White)
Focus Color bar Gray 1 (20%
brightness)
Cyan Magenta Yellow
5/62
2.8. MENU key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 4Dh 4Eh 03h
Character A D Z Z ; O M N
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 4Dh 4Eh 03h
Character O M N
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No Yes No Yes Yes
2.9. ENTER key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 45h 4Eh 03h
Character A D Z Z ; O E N
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 45h 4Eh 03h
Character O E N
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No Yes No Yes Yes
2.10. Up () key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 55h 03h
Character A D Z Z ; O C U
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 55h 03h
Character O C U
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No Yes No Yes Yes
2.11. Down () key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 44h 03h
Character A D Z Z ; O C D
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 44h 03h
Character O C D
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No Yes No Yes Yes
2.12. Left () key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 4Ch 03h
Character A D Z Z ; O C L
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 4Ch 03h
Character O C L
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No Yes No Yes Yes
6/62
2.13. Right () key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 52h 03h
Character A D Z Z ; O C R
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 52h 03h
Character O C R
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No Yes No Yes Yes
2.14. DEFAULT key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 54h 03h
Character A D Z Z ; O S T
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 54h 03h
Character O S T
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes
2.15. FUNC1 key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 46h 43h 31h 03h
Character A D Z Z ; F C 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 46h 43h 31h 03h
Character F C 1
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No (Yes) (Yes) (Yes) (Yes)
Note:
• The acceptability conforms to the function allocated in FUNC1.
2.16. SYSTEM SELECTOR
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 4Ch 03h
Character A D Z Z ; O S L
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 4Ch 03h
Character O S L
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Note:
• When the input signal is not swi tchable, ER401 is returned.
2.17. Numeric key
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 4Eh 4Bh 3Ah *1 03h
Character A D Z Z ; O N K : *2
Paramet ers (* 1, *2)
0 key 1 key 2 key 3 key 4 key 5 key 6 key 7 key 8 key 9 key Hexadecimal 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h
Character 0 1 2 3 4 5 6 7 8 9
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 4Eh 4Bh 3Ah *1 03h
Character O N K : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes No Yes Yes
7/62
2.18. LAMP SELECT
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Ch 50h 4Dh 3Ah *1 *3 03h
Character A D Z Z ; L P M : *2 *4
Paramet ers (* 1, *2, *3 , *4 )
QUAD L1/L4 L2/L3 DUAL L1/L2/L3 Hexadecimal 30h 30h 30h 31h 30h 32h 33h 33h 30h 34h
Character 0 0 0 1 0 2 0 3 0 4 L1/L2/L4 L1/L3/L4 L2/L3/L4 TRIPLE L1 Hexadecimal 30h 35h 30h 36h 30h 37h 30h 38h 30h 39h
Character 0 5 0 6 0 7 0 8 0 9 L2 L3 L4 SINGLE Hexadecimal 31h 30h 31h 31h 31h 32h 31h 33h
Character 1 0 1 1 1 2 1 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Ch 50h 4Dh 3Ah *1 *3 03h
Character L P M : *2 *4
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No Yes Yes Yes Yes Yes
Note:
• During the lamp change processing, ER401 is returned.
2.19. INSTALLATION
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 49h 4Ch 3Ah *1 03h
Character A D Z Z ; O I L : *2
Paramet ers (* 1, *2)
FRONT-F REAR-F FRONT-C REAR-C Hexadecimal 30h 31h 32h 33h
Character 0 1 2 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 49h 4Ch 3Ah *1 03h
Character O I L : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No Yes Yes Yes Yes Yes
2.20. SUB MEM ORY CHA N GE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 53h 3Ah
Character A D Z Z ; O C S :
Hexadecimal *1 *3 03h
Character *2 *4
Paramet ers (* 1, *2, *3 , *4 )
*nn of submemory number (mm—nn)
01 02 03 04
Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 1 0 2 0 3 0 4
93 94 95 96
Hexadecimal 39h 33h 39h 34h 39h 35h 39h 36h
Character 9 3 9 4 9 5 9 6
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 53h 3Ah *1 *3 03h
Character O C S : *2 *4
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
8/62
2.21. SUB MEM ORY CHA N GE (Enhanced)
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 53h 3Ah
Character A D Z Z ; O C S :
Hexadecimal *1 *3 2Dh *5 *7 03h
Character *2 *4  *6 *8
Parameters
mm of submemory number (mm–nn) (*1,*2,*3,*4)
01 02 03 04
Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 1 0 2 0 3 0 4
92 93 94 95
Hexadecimal 39h 32h 39h 33h 39h 34h 39h 35h
Character 9 2 9 3 9 4 9 5
nn of submemory number (mm–nn) (*5, *6, *7, *8)
01 02 03 04
Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 1 0 2 0 3 0 4
93 94 95 96
Hexadecimal 39h 33h 39h 34h 39h 35h 39h 36h
Character 9 3 9 4 9 5 9 6
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 53h 3Ah *1 *3 2Dh *5 *7 03h
Character O C S : *2 *4  *6 *8
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
2.22. SUB MEMORY STORE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 45h 53h 03h
Character A D Z Z ; O E S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 45h 53h 03h
Character O E S
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
2.23. SUB MEM ORY DELE TE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 44h 53h 3Ah
Character A D Z Z ; O D S :
Hexadecimal *1 *3 2Dh *5 *7 03h
Character *2 *4  *6 *8
Parameters (*1, *2, *3, *4, *5, *6)
mm of submemory number (mm–nn) (*1,*2)
01 02 03 04
Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 1 0 2 0 3 0 4
92 93 94 95
Hexadecimal 39h 32h 39h 33h 39h 34h 39h 35h
Character 9 2 9 3 9 4 9 5
nn of submemory number (mm–nn) (*3,*4)
01 02 03 04
Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 1 0 2 0 3 0 4
93 94 95 96
Hexadecimal 39h 33h 39h 34h 39h 35h 39h 36h
Character 9 3 9 4 9 5 9 6
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 44h 53h 3Ah *1 *3 2Dh *5 *7 03h
Character O D S : *2 *4  *6 *8
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
9/62
2.24. PICTURE MODE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 50h 4Dh 3Ah
Character A D Z Z ; V P M :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
DYNAMIC GRAPHIC USER Hexadecimal 44h 59h 4Eh 47h 52h 41h 55h 53h 52h
Character D Y N G R A U S R STANDARD CINEMA NATURAL Hexadecimal 53h 54h 44h 43h 49h 4Eh 4Eh 41h 54h
Character S T D C I N N A T
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 50h 4Dh 3Ah *1 *3 *5 03h
Character V P M : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
2.25. COLOR
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 43h 4Fh 3Ah
Character A D Z Z ; V C O :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2 98 99 100 Hexadecimal 30h 39h 38h 30h 39h 39h 31h 30h 30h
Character 0 9 8 0 9 9 1 0 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 43h 4Fh 3Ah *1 *3 *5 03h
Character V C O : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
Note:
• It is displayed in the menu by the value in which 50 is subtracted fr om the specified value.
2.26. TINT
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 54h 4Eh 3Ah
Character A D Z Z ; V T N :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2 60 61 62 Hexadecimal 30h 36h 30h 30h 36h 31h 30h 36h 32h
Character 0 6 0 0 6 1 0 6 2
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 54h 4Eh 3Ah *1 *3 *5 03h
Character V T N : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
Note:
• It is displayed in the menu by the value in which 31 is subtracted fr om the specified value.
10/62
2.27. COLOR TEMP.
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 54h 45h 3Ah
Character A D Z Z ; O T E :
Hexadecimal *1 *3 03h
Character *2 *4
Paramet ers (* 1, *2, *3 , *4 )
LOW MIDDLE HIGH USER1 USER2 DEFAULT
Hexadecimal 30h 31h 32h 34h 39h 31h 30h
Character 0 1 2 4 9 1 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 54h 45h 3Ah *1 *3 03h
Character O T E : *2 *4
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Note:
• If you specify param eters other than USER1 when COLOR MATCHING is not OFF, ER402 is returned.
2.28. W HI TE BALA NCE L OW — R
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 4Fh 52h 3Ah
Character A D Z Z ; V O R :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
1 2 3 Hexadecimal 30h 30h 31h 30h 30h 32h 30h 30h 33h
Character 0 0 1 0 0 2 0 0 3 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h
Character 2 5 3 2 5 4 2 5 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 4Fh 52h 3Ah *1 *3 *5 03h
Character V O R : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Notes:
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is ret urned.
• It is displayed in the menu by the value in which 128 is subtracted fr om the specified value.
2.29. W HI TE BALA NCE L OW — G
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 4Fh 47h 3Ah
Character A D Z Z ; V O G :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters(*1,*2,*3,*4,*5,*6)
1 2 3 Hexadecimal 30h 30h 31h 30h 30h 32h 30h 30h 33h
Character 0 0 1 0 0 2 0 0 3 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h
Character 2 5 3 2 5 4 2 5 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 4Fh 47h 3Ah *1 *3 *5 03h
Character V O G : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Notes:
•When a parameter ot her t han USER1 or USER2 is specified for COLOR TEMP., ER401 is returned.
• It is displayed in the menu by the value in which 128 is subtracted fr om the specified value.
11/62
2.30. W HI TE BALA NCE L OW — B
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 4Fh 42h 3Ah
Character A D Z Z ; V O B :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
1 2 3 Hexadecimal 30h 30h 31h 30h 30h 32h 30h 30h 33h
Character 0 0 1 0 0 2 0 0 3 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h
Character 2 5 3 2 5 4 2 5 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 4Fh 42h 3Ah *1 *3 *5 03h
Character V O B : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Notes:
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is ret urned.
• It is displayed in the menu by the value in which 128 is subtracted fr om the specified value.
2.31. W HI TE BALA NCE HI GH — R
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 48h 52h 3Ah
Character A D Z Z ; V H R :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h
Character 2 5 3 2 5 4 2 5 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 48h 52h 3Ah *1 *3 *5 03h
Character V H R : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Note:
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is ret urned.
2.32. W HI TE BALA NCE HI GH — G
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 48h 47h 3Ah
Character A D Z Z ; V H G :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h
Character 2 5 3 2 5 4 2 5 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 48h 47h 3Ah *1 *3 *5 03h
Character V H G : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Note:
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is ret urned.
12/62
2.33. W HI TE BALA NCE HI GH — B
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 48h 42h 3Ah
Character A D Z Z ; V H B :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h
Character 2 5 3 2 5 4 2 5 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 48h 42h 3Ah *1 *3 *5 03h
Character V H B : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Note:
• When a parameter other than USER1 or USER2 is specified for COLOR TEMP., ER401 is ret urned.
2.34. CONTRAST
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 43h 4Eh 3Ah
Character A D Z Z ; V C N :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
1 2 3 Hexadecimal 30h 30h 31h 30h 30h 32h 30h 30h 33h
Character 0 0 1 0 0 2 0 0 3 61 62 63 Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h
Character 0 6 1 0 6 2 0 6 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 43h 4Eh 3Ah *1 *3 *5 03h
Character V C N : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
Note:
• It is displayed in the menu by the value in which 32 is subtracted fr om the specified value.
2.35. BRIGHTNESS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 42h 52h 3Ah
Character A D Z Z ; V B R :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
1 2 3 Hexadecimal 30h 30h 31h 30h 30h 31h 30h 30h 33h
Character 0 0 1 0 0 2 0 0 3 61 62 63 Hexadecimal 30h 36h 30h 30h 36h 31h 30h 36h 32h
Character 0 6 1 0 6 2 0 6 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 42h 52h 3Ah *1 *3 *5 03h
Character V B R : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
Note:
• It is displayed in the menu by the value in which 32 is subtracted fr om the specified value.
13/62
2.36. SHARPNESS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 53h 52h 3Ah
Character A D Z Z ; V S R :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2 13 14 15 Hexadecimal 30h 31h 33h 30h 31h 34h 30h 31h 35h
Character 0 1 3 0 1 4 0 1 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 53h 52h 3Ah *1 *3 *5 03h
Character V S R : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
2.37. NOISE REDUCTION
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 4Eh 53h 3Ah
Character A D Z Z ; V N S :
Hexadecimal *1 03h
Character *2
Paramet ers (* 1, *2)
OFF ON or 1 2 3
Hexadecimal 30h 31h 32h 33h
Character 0 1 2 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 4Eh 53h 3Ah *1 03h
Character V N S : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes Yes Yes
Notes:
• When FRAME DELAY is set to SHORT, ER401 is returned.
• During P IN P, ER401 is returned.
14/62
2.38. DYNAMIC IRIS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Paramet ers (* 1, *2)
Mode
OFF 1 2 3 USER AUTO
Hexadecimal 30h 31h 32h 33h 34h 41h 4Dh 44h
Character 0 1 2 3 4 A M D * When Mode is OFF—USER, parameters *3—*6 are not sent. Example: When you set USER into Mode
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 34h 03h
Character A D Z Z ; O A I 4 * When Mode is AUTO IRIS or DYNAMIC GAMMA, parameters *5 and *6 are not sent. Example: When Mode is AUTO IRIS and you set 3 into AUTO IR IS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 41h 33h 03h
Character A 3
Example: When Mode is MANUAL IRIS and you set 30 into MANUAL IRIS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 4Dh 33h 30h 03h
Character M 3 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah *1 03h
Character O A I : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
2.39. DYNAMIC IRIS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah *1 03h
Character A D Z Z ; O A I : *2
Paramet ers (* 1, *2)
OFF 1 2 3 USER
Hexadecimal 30h 31h 32h 33h 34h
Character 0 1 2 3 4
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah *1 03h
Character O A I : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
2.40. DYNAMIC IRIS (AUTO IRIS)
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 41h *1 03h
Character A *2
Paramet ers (* 1, *2)
OFF 1 2 3
Hexadecimal 30h 31h 32h 33h
Character 0 1 2 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah 41h *1 03h
Character O A I : A *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
MANUAL IRIS DYNAMIC-GAMMA
IRIS
15/62
2.41. DYNAMIC IRIS (MANUAL IRIS)
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 4Dh *1 *3 03h
Character M *2 *4
Paramet ers (* 1, *2, *3 , *4 )
OFF 1 2 3
Hexadecimal 30h 30h 30h 31h 30h 32h 30h 33h
Character 0 0 0 1 0 2 0 3
60 61 62 63
Hexadecimal 36h 30h 36h 31h 36h 32h 36h 33h
Character 6 0 6 1 6 2 6 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah 4Dh *1 03h
Character O A I : M *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
2.42. DYN A MIC IRIS (DYNA M IC GAM MA )
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 44h *1 03h
Character D *2
Paramet ers (* 1, *2)
OFF 1 2 3
Hexadecimal 30h 31h 32h 33h
Character 0 1 2 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah 44h *1 03h
Character O A I : D *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
2.43. TV-SYSTEM
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 53h 47h 3Ah
Character A D Z Z ; V S G :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
AUTO 1 AUTO 2 NTSC Hexadecimal 41h 54h 31h 41h 54h 32h 4Eh 54h 53h
Character A T 1 A T 2 N T S
NTSC4.43 PAL PAL-M Hexadecimal 4Eh 34h 34h 50h 41h 4Ch 50h 41h 4Dh
Character N 4 4 P A L P A M
PAL-N SECAM PAL60 Hexadecimal 50h 41h 4Eh 53h 45h 43h 50h 36h 30h
Character P A N S E C P 6 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 53h 47h 3Ah *1 *3 *5 03h
Character V S G : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
16/62
2.44. SHIFT H
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 54h 48h 3Ah
Character A D Z Z ; V T H :
Hexadecimal *1 *3 *5 *7 03h
Character *2 *4 *6 *8
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h 30h 30h 30h 2
Character 0 0 0 0 0 0 0 1 0 0 0 2
Hexadecimal 34h 30h 39h 33h 34h 30h 39h 34h 34h 30h 39h 35h
Character 4 0 9 3 4 0 9 4 4 0 9 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 54h 48h 3Ah *1 *3 *5 03h
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Note:
The maximum value that can be actually set changes according to the input signal and the input resolution setting, etc.
2.45. SHIFT V
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 54h 56h 3Ah
Character A D Z Z ; V T V :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h 30h 30h 30h 32h
Character 0 0 0 0 0 0 0 1 0 0 0 2
Hexadecimal 34h 30h 39h 33h 34h 30h 39h 34h 34h 30h 39h 35h
Character 4 0 9 3 4 0 9 4 4 0 9 5
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 54h 56h 3Ah *1 *3 *5 03h
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Note:
The maxim um value that can be actually set changes according to the input signal and the input resolution setting, etc.
0 1 2
4093 4094 4095
Character V T H : *2 *4 *6
No No No Yes No Yes
0 1 2
4093 4094 4095
Character V T V : *2 *4 *6
No No No Yes No Yes
17/62
2.46. ASPECT
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 53h 45h 3Ah
Character A D Z Z ; V S E :
Hexadecimal *1 *3 03h
Character *2 *4
Paramet ers (* 1, *2, *3 , *4 )
• Input route: VIDEO
Input signal: NTSC
Hexadecimal 30h 31h 32h 33h 35h
Character 0 1 2 3 5
Hexadecimal 36h 39h
Character 6 9
• Input route: VIDEO
Input signal: Except NTSC
Hexadecimal 30h 31h 32h 33h 35h
Character 0 1 2 3 5
Hexadecimal 36h 39h
Character 6 9
• Input route: S-VIDEO
Input signal: NTSC
Hexadecimal 30h 31h 32h 33h 35h
Character 0 1 2 3 5
Hexadecimal 36h 39h 32h 30h 33h 30h
Character 6 9 2 0 3 0
• Input route: S-VIDEO
Input signal: Except NTSC
Hexadecimal 30h 31h 32h 33h 35h
Character 0 1 2 3 5
Hexadecimal 36h 39h
Character 6 9
• Input route: Except VI DEO/S-VIDEO
Input signal: SD
Hexadecimal 30h 32h 33h 35h
Character 0 2 3 5
Hexadecimal 36h 39h
Character 6 9
• Input route: Except VI DEO/S-VIDEO
Input signal: HD
Hexadecimal 30h 31h 33h 35h
Character 0 1 3 5
Hexadecimal 36h 39h
Character 6 9 *1: Because it is not able to specify it in D10000, ER402 is returned. *2: Because it is not able to specify it in DW10000, ER402 is returned.
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 53h 45h 3Ah *1 *3 03h
Character V S E : *2 *4
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes No Yes
Notes:
• When it is not able to set it according to the input signal, ER402 is ret urned.
• Parameter *3 and *4 are speci fi ed only for two digits.
VID AUTO 4:3 *1 16:9 *2 S4:3 *2 THROUGH
HV FIT H FIT *1
DEFAULT 4:3 * 1 16:9 *2 S4:3 *2 THROUGH
HV FIT H FIT *1
VID AUTO(PRI.) 4:3 *1 16:9 *2 S4:3 *2 THROUGH
HV FIT H FIT *1 S1 AUTO VID AUTO
DEFAULT 4:3 * 1 16:9 *2 S4:3 *2 THROUGH
HV FIT H FIT *1
DEFAULT 16:9 *2 S4:3 *2 THROUGH
HV FIT H FIT *1
DEFAULT 4:3 *1 S4:3 *2 THROUGH
HV FIT H FIT *1
18/62
2.47. ZOOM H
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 5Ah 48h 3Ah
Character A D Z Z ; O Z H :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
50 51 52 Hexadecimal 30h 35h 30h 30h 35h 31h 30h 35h 32h
Character 0 5 0 0 5 1 0 5 2
997 998 999 Hexadecimal 39h 39h 37h 39h 39h 38h 39h 39h 39h
Character 9 9 7 9 9 8 9 9 9
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 5Ah 48h 3Ah *1 *3 *5 03h
Character O Z H : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes No Yes
Notes:
• When ASPECT is THROUGH, ER401 is returned.
• If INTERLOCKED is ON, set it to OFF.
2.48. ZOOM V
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 5Ah 56h 3Ah *1 *3 *5 03h
Character A D Z Z ; O Z V : *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
50 51 52 Hexadecimal 30h 35h 30h 30h 35h 31h 30h 35h 32h
Character 0 5 0 0 5 1 0 5 2
997 998 999 Hexadecimal 39h 39h 37h 39h 39h 38h 39h 39h 39h
Character 9 9 7 9 9 8 9 9 9
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 5Ah 56h 3Ah *1 *3 *5 03h
Character O Z V : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes No Yes
Notes:
• When ASPECT is THROUGH, ER401 is returned.
• If INTERLOCKED is ON, set it to OFF.
2.49. CLOCK PHASE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 43h 50h 3Ah *1 *3 *5 03h
Character A D Z Z ; V C P : *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2
29 30 31 Hexadecimal 30h 32h 39h 30h 33h 30h 30h 33h 31h
Character 0 2 9 0 3 0 0 3 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 43h 50h 3Ah *1 *3 *5 03h
Character V C P : *2 *4 *6
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No No Yes No Yes
Note:
• It is able to accept only when the selected slot is RGB1 or RGB2, and ER401 is retur ned besides.
19/62
Loading...
+ 43 hidden pages