Operating
instructions
ROOM AIR CONDITIONERS
MODELS: CW-903FR, CW-1203FR
CW-973FR, CW-1273FR
When you’re looking for comfort and convenience in a room air conditioner, look to
Panasonic
F561021
Before using your air conditioner, please read this operating instructions carefully and keep it for future reference.
Operating Instructions
Room Air Conditioners
[CONTENTS]
CW-903FR, CW-1203FR (Cooling Only)
Product Component Identification............................................................................................... 2
Air Conditioner Operation............................................................................................................ 3
CW-973FR, CW-1273FR (Cooling And Heating)
Product Component Identification............................................................................................... 4
Air Conditioner Operation ........................................................................................................... 5
Operation Tips........................................................................................................................... 6
Caution......................................................................................................................................... 7
Care And Maintenance................................................................................................................ 8
Installation........................................................................................................................... Q-IO
Before Calling The Serviceman.........................................................................................11-12
Prod uc t Co mpo ne nt I den ti fi cat io n
CW-903FR, CW-1203FR
Vertical Airflow Direction Vane
(Airflow direction adjustment
Ventilation Lever
When the slide lever is at the;
Up-and-Down)
The vertical airflow
direction vane is
controlled by posi
tioning the vane to
discharge the air
upwards, downwards or
straight out.
Vertical airflow direction
adjustment louvers
Air outlet grille
CLOSE ^ VENT ►OPEN
“OPEN” position, the vent, door
opens to allow air, smoke or odours
to be expelled from the room.
CLOSED VENT ►OPEN
“CLOSE” position, the vent, door
is closed and the air inside the room
is circulated and conditioned.
Air Swing Switch
AIR SWING
OFF
OFF
Stops the operation of Air Swing.
ON
Thermostat Control Knob
When you turn the
Thermostat Control
Knob to the desired
setting, the thermo
stat will automatically
control the tempe
rature of the indoor
air. The further clockwise you turn the
knob, the cooler the indoor air will become.
ON
Air Swing is in operation.
Power supply cord
Main Control Knob
OFF
Stops all operations.
LOW FAN
Fan only operation without
cooling at low fan speed.
HIGH FAN
Fan only operation without
cooling at high fan speed.
(fan only operation recir
culates filtered room air).
LOW COOL
Cooling operation at low fan speed.
HIGH COOL
Cooling operation at high fan speed.
t (
HIGH
FAN
8 Ç
„2-
Air Co nd it ion er O pe rat io n
CW-903FR, CW-1203FR (Cooling Only)
II
2. Open the
cover.
3. Main Control Knob
Set to either LOW COOL or HIGH COOL as
required. (FAN setting operates the fan only.)
Caution: If the Main Control Knob is turned off
or changed to a fan setting from a cooling
operation setting, WAIT at least 3 minutes
before resetting to a cooling operation.
1. Power Supply
Set the Main Control Knob to the OFF
position: confirm that the Power Supply
Cord is connected to a proper AC outlet.
Recommended
Use the air conditioner
under the following
conditions:
When humidity does not exceed 90% and
room temperature is above 21 °C.
4. Thermostat Control Knob
Set the Thermostat Control Knob at the desired
setting. (Usually "6 ~ 7’ is a recommended
setting position.) If the room temperature is
unsatisfactory after a reasonable amount of
time, turn the control knob clockwise to cool the
room more. Or anti-clockwise to cool the room
less.
• When the Thermostat Control knob is set to
“10”, moisture may freeze onto the coils and
prevent effective cooling. If this happens, turn
the knob to High Fan, and the thermostat
control anti-clockwise. This will quickly defrost
the cooling coil so that normal cooling can be
resumed.
5. Air Swing Switch
(Airflow direction adjustment
Side-to-Side)
Continuous operation at over 90% humidity
may create condensation and waterdrops on
the intake and outlet vents.
For fixed side-to-side air direction, set the Air
Swing Switch to “ON” until the desired air
direction is obtained, then move it to “OFF”.
For continuous side-to-side air circulation, set
the Air Swing Switch to “ON" and leave it there.
-3-