● Replacement Part List .............................36, 38
● Electronic Parts List ....................................... 39
1996 Matsushita Industrial Corp. Sdn. Bhd.
(11969-T)
All rights reserved. Unauthorized copying and distribution is a violation of law.
CS-MC120KE
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain
warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity
should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with
in this service information by anyone else could result in serious injury or death.
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigeration circuit.
Features
!
WARNING
!
PRECAUTION OF LOW TEMPERATURE
• High Efficiency
• Compact Design
• Comfort Improvement
– Wider range of horizontal discharge air
– Longer hours of sleep mode operation
• Auto Restart
– Auto restart operation after power failure
• Removable and Washable
Front Panel
• Installation Work Improvement
– Long piping up to 15 m.
• Quality Improvement
– Low voltage protection
– Gas leakage protection
– Prevent compressor reverse cycle
– 2-stage OLP to protect compressor
• Service Improvement
– Easy fan motor replacement procedure
– 1 –
Functions
Remote Control
CS-MC120KE
OFF / ON I
MODE
FAN SPEED
AIR SWING
Operation OFF / ON
Operation Mode Selection
• AUTOAutomatic Operation Mode
• COOLCooling Operation Mode
• DRYSoft Dry Operation Mode
• FANAir Circulation Mode
Indoor Fan Speed Selection
• h j kLow Speed
l
• h j kMedium Speed
lll
• h j kHigh Speed
lllll
• AUTOFANAutomatic Fan Speed
Airflow Direction Control
• SWINGAutomatic Airflow Direction
Control
• MANUALAirflow Direction Manual Control
TEMP.
ON-TIMER
OFF-TIMER
TIME
SET
CANCEL
CLOCK
(q)
Room Temperature Setting
• Temperature Setting (16˚C to 30˚C)
• Automatic Operation
m / n 2˚C lower than standard
n Standard
n - o 2˚C higher than standard
Timer Operation Selection
• 24-hour, OFF / ON Real Timer Setting.
Time / Timer Setting
• Hours and minutes setting.
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
Clock Setting
• Current time setting.
– 2 –
SLEEP
Sleep Mode Operation OFF / ON
CS-MC120KE
Functions
Indoor Unit
POWER I
AUTO
OFF / ON
TEST RUN
OFF / ON
Power Switch OFF / ON
Auto Operation Switch
• Used when the remote control cannot be
used.
Remote Control Signal Receiving
Sound Control
• It can be controlled by pressing Auto
Operation Switch for 10 seconds.
Operation Test Running / Pump
Down Switch
• Used when test running or servicing.
Operation Indication Lamps (LED)
• POWER (Red)......Lights up in operation,
blinks in Automatic
Operation Mode judging
• SLEEP (Orange).....Lights up in Sleep
Mode Operation
• TIMER (Orange).....Lights up in Timer
Setting
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Auto Restart Control
• Operation is restarted after power failure
at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates and stops at 4-second
intervals at low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Cooling : Fan rotates at Hi and Me
speed. Deodorizing control is
available.
– Soft Dry : Fan rotates at SLo and Lo
speed. Deodorizing control is
available.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
– 3 –
Functions
Outdoor Unit
CS-MC120KE
Compressor Reverse Rotation
Protection Control
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
Overload Protector
• 2-Stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases to
120°C.
– High temperature or high current flows to
compressor.
(Refer circuit diagram for OLP
characteristic)
60 Secs. Forced Operation Control
• Once the compressor is activated, it does
not stop for 60 secs. (Stops immediately
with remote control stop signal.)
Outdoor Fan Operation Control
•
Inner protector.
– 4 –
CS-MC120KE
Product Specifications
Cooling Capacity
Moisture Removal
Power Source
Airflow Method
Air Volume
Noise Level
Electrical
Data
Indoor Air (Lo)
Indoor Air (Me)
Indoor Air (Hi)
Outdoor Air
Input
Running Current
Unit
kW
Btu/h
s/h
Pint/h
Phase
V
Cycle
OUTLET
INTAKE
3
/min (cfm)
m
3
m
/min (cfm)
3
m
/min (cfm)
m3/min (cfm)
dB (A)
W
A
CS-MC120KE
3.50 × 2 - 3.45 × 2
11,900 × 2 - 11,800 × 2
240 - 220
SIDE VIEW
7.3 (260)
7.6 (270)
8.3 (290)
–
High 39 - 39, Low 36 - 35
1,260 × 2 - 1,210 × 2
5.7 × 2 - 5.7 × 2
CU-MC240KE
2.0 × 2
4.2 × 2
Single
50
TOP VIEW
–
–
–
22.0 (780)
(1 Unit) (2 Unit)
High 49 - 48, High 52 - 51
COP
Starting Current
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Hose
Power Cord Length
Dimensions
Net Weight
Compressor
Air Circulation
Inner diameter
Length
Number of core-wire
MotorType
RatedOutput
MotorType
FanLow
SpeedMedium
Height
Width
Depth
Type
Type
Material
Input
Rated Output
High
W/W
A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)
W
W
W
rpm
rpm
rpm
G ; Half Union 1/2"
L ; Half Union 1/4"
G (gas side) ; 1/2"
L (liquid side) ; 1/4"
12
0.7
2.1
2
3 (1.0 mm
11-7/16 (290)
31-15/32 (799)
6-29/32 (175)
18 (8.0)
Cross-flow Fan
AS + Glass Fiber 30%
Induction (4-poles)
)
–
–
–
27
10
1,200
1,250
1,360
2.7 - 2.8
25 × 2
G ; 3-way valve 1/2"
L ; 2-way valve 1/4"
G (gas side) ; 1/2"
L (liquid side) ; 1/4"
–
–
–
–
41-5/32 (1045)
30-23/32 (780)
9-21/32 (245)
179 (81)
Rotary (1 cylinder)
rolling piston type
Induction (2-poles)
1,100 × 2
Propeller Fan
AES + Glass Fiber 16%
Induction (6-poles)
60.7 × 2
20 × 2
–
–
730
– 5 –
Product Specifications
CS-MC120KE
Unit
Heat
Exchanger
Refrigerant Control Device
Refrigeration Oil
Refrigerant (R-22)
Thermostat
Protection Device
Capillary Tube
Air Filter
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
• Specifications are subject to change without notice for further improvement.