ERZC10DK471U250VSC3ATC4093BPTC4069UBPTA7555P2SC1173 - 0UN4215 - S - TAUN4215 - S - TAUN4215 - S - TAG4FN - 24VDC or G4F - 24VDCG4U - 24VDC or G4U - 1 - 24VDCG4U - 24VDC or G4U - 1 - 24VDCSSA042
(Note)●All parts are supplied from ADC / JAPAN.
– 55 –
MAICO
Printed in Malaysia
P970602400YW
CS-MC90KE
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain
warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity
should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with
in this service information by anyone else could result in serious injury or death.
Features
!
WARNING
!
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigeration circuit.
• High Efficiency
• Compact Design
• Comfort Improvement
– Wider range of horizontal discharge air
– Longer hours of sleep mode operation
• Auto Restart
– Auto restart operation after power failure
• Removable and Washable
Front Panel
• Installation Work Improvement
– Long piping up to 15 m for each unit.
– 1 –
Functions
Remote Control
CS-MC90KE
OFF / ON I
MODE
FAN SPEED
AIR SWING
Operation OFF / ON
Operation Mode Selection
• AUTOAutomatic Operation Mode
• COOLCooling Operation Mode
• DRYSoft Dry Operation Mode
• FANAir Circulation Mode
Indoor Fan Speed Selection
• h j kLow Speed
l
• h j kMedium Speed
lll
• h j kHigh Speed
lllll
• AUTOFANAutomatic Fan Speed
Airflow Direction Control
• SWINGAutomatic Airflow Direction
Control
• MANUALAirflow Direction Manual Control
TEMP.
ON-TIMER
OFF-TIMER
TIME
SET
CANCEL
CLOCK
(q)
Room Temperature Setting
• Temperature Setting (16˚C to 30˚C)
• Automatic Operation
m / n 2˚C lower than standard
n Standard
n - o 2˚C higher than standard
Timer Operation Selection
• 24-hour, OFF / ON Real Timer Setting.
Time / Timer Setting
• Hours and minutes setting.
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
Clock Setting
• Current time setting.
– 2 –
SLEEP
Sleep Mode Operation OFF / ON
CS-MC90KE
Functions
Indoor Unit
POWER I
AUTO
OFF / ON
TEST RUN
OFF / ON
Power Switch OFF / ON
Auto Operation Switch
• Used when the remote control cannot be
used.
Remote Control Signal Receiving
Sound Control
• It can be controlled by pressing Auto
Operation Switch for 10 seconds.
Operation Test Running / Pump
Down Switch
• Used when test running or servicing.
Operation Indication Lamps (LED)
• POWER (Red)......Lights up in operation,
blinks in Automatic
Operation Mode judging
• SLEEP (Orange).....Lights up in Sleep
Mode Operation
• TIMER (Orange).....Lights up in Timer
Setting
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Auto Restart Control
• Operation is restarted after power failure
at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates and stops at 4-second
intervals at low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Cooling : Fan rotates at Hi and Me
speed. Deodorizing control is
available.
– Soft Dry : Fan rotates at SLo and Lo
speed. Deodorizing control is
available.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
– 3 –
Functions
Outdoor Unit
CS-MC90KE
Compressor Reverse Rotation
Protection Control
• To protect compressor from reverse rotation
when there is a instantaneous power failure.
60 secs. Forced Operation Control
• Once the compressor is activated, it does not
stop for 60 secs. (Stops immediately with
remote control stop signal.)
Overload Protector
Restart Control
(3 minutes)
• Once the compressor stops, the compressor
and the outdoor fan motor will not start for 3
minutes.
(Fan motor is still running if the compressor is
stopped by overload protector tripping.)
Starting Current Control
(2 seconds delay)
• When both compressors are started
simultaneously, one compressor will start
immediately whereas another compressor
will start after 2 seconds.
– 4 –
CS-MC90KE
Product Specifications
Cooling Capacity
Moisture Removal
Power Source
Airflow Method
Air Volume
Noise Level
Electrical
Data
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Hose
Power Cord Length
Dimensions
Net Weight
Compressor
Air Circulation
Indoor Air (Lo)
Indoor Air (Me)
Indoor Air (Hi)
Outdoor Air