Panasonic CU-J18DBE5, CU-B34DBE8, CU-B18DBE5, CU-B28DBE5, CU-B43DBE8 Operating Instructions

...
QUICK GUIDE / GUÍA RÁPIDA GUIDA RAPIDA / KURZANLEITUNG GUΙA RÁPIDO / SNELLE GIDS
E
CLOS
OPEN
OPEN
SE
CLO
ENGLISH 2 ~ 11
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
ESPAÑOL 12 ~ 21
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta.
ITALIANO 22 ~ 31
Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro.
DEUTSCH 32 ~ 41
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.
PORTUGUÊS 42 ~ 51
Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.
F566077
Operating Instructions
Air Conditioner
Indoor Unit CS-F14DB4E5 CS-F34DB4E5
CS-F18DB4E5 CS-F43DB4E5 CS-F24DB4E5 CS-F50DB4E5 CS-F28DB4E5
Outdoor Unit
Inverter Model (HBE5 Series) (DBE5, DBE8 Series)
CU-YL24HBE5 CU-L24DBE5 CU-YL28HBE5 CU-L28DBE5 CU-YL34HBE5 CU-L34DBE5 CU-YL43HBE5 CU-L43DBE5
(GBE5 Series) CU-L34DBE8
CU-YL24GBE5 CU-L43DBE8 CU-YL28GBE5 CU-L50DBE8 CU-YL34GBE5 CU-YL43GBE5
Heat-pump Model
CU-B14DBE5 CU-B28DBE8 CU-B18DBE5 CU-B34DBE8 CU-B24DBE5 CU-B43DBE8 CU-B28DBE5 CU-B50DBE8 CU-B34DBE5
Cooling Model
CU-J14DBE5 CU-J24DBE8 CU-J18DBE5 CU-J28DBE8 CU-J24DBE5 CU-J34DBE8 CU-J28DBE5 CU-J43DBE8 CU-J34DBE5 CU-J50DBE8
NEDERLANDS 52 ~ 61
Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik.
QUICK GUIDE / GUÍA RÁPIDA GUIDA RAPIDA / KURZANLEITUNG GUΙA RÁPIDO / SNELLE GIDS
© 2008 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
Air outlet
Air outlet
Air inlet
Air inlet
Air inlet
DEFINITION
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is PROHIBITED.
To prevent personal injury, injury to others, or property damage, please observe the following. Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:
Warning
This sign warns of death or serious injury.
These symbols denote actions that are COMPULSORY.
This sign warns of
Caution
injury or damage to property.
Wireless Remote Control
• Do not use rechargeable (Ni-Cd) batteries.
• Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
• Remove the batteries if the unit is not going to be used for a long period of time.
• New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
Indoor Unit
• Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.
• Do not insert your fi ngers or other objects into the unit.
• Do not attempt to repair the unit by yourself.
Air outlet
Air inlet
Indoor Unit
• Do not install the unit in a potentially explosive atmosphere.
• Do not wash the unit with water, benzene, thinner or scouring powder.
• Do not use for other purposes such as preservation of food.
• Do not use any combustible equipment in front of the airfl ow outlet.
• Do not expose directly to cold air for a long period.
• Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur.
• Aerate the room regularly.
Power Supply
• Switch off the power supply before cleaning or servicing.
• Turn off the power supply if the
Power Supply
• Do not share the same power outlet with other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Use the specifi ed supply cord.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
• This equipment must be earthed and
Air inlet
Air inlet
unit is not used for a long period of time.
• This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply. Do not touch the air conditioner during lightning, it may cause electric shock.
strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock or fi re in case of malfunction.
• In case of emergency or abnormal conditions (burnt smell, etc), turn off the power supply, and consult your nearest dealer.
Air outlet
Outdoor Unit
• Do not sit or step on the unit, you may fall down accidentally.
• Do not touch the sharp aluminum n, sharp parts may cause injury.
• Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur.
Outdoor Unit
• Do not insert your fi ngers or other objects
• After long periods of use, make sure the installation rack is not damaged.
into the unit, sharp parts may cause
2
injury.
REGULATORY INFORMATION REGULATORY INFORMATION
TABLE OF CONTENTS
OPERATION CONDITION
NOTE :
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
OPERATION CONDITION
Use this air conditioner under the following temperature range
Model Temperature (°C) Indoor Outdoor
Inverter
(GBE5, DBE5,
DBE8 Series)
Heat-pump
Cooling COOLING
NOTICE: This unit is still able to operate as a cooler with outdoor temperature as low as
-15°C*/ -10°C** in a non-living room, such as a computer room, with a room temperature of 21°C or above, and room humidity up to 45%.
(CU-YL24HBE5, CU-YL28HBE5, CU-YL34HBE5, CU-YL43HBE5)
COOLING
HEATING
NOTICE: This unit is still able to operate as a cooler with outdoor temperature as low
as -5°C in a non-living room, such as a computer room, with a room temperature of 21°C or above, and room humidity up to 45%.
COOLING
HEATING
COOLING
HEATING
Temperature (°C) Indoor Outdoor
Maximum 32 43
Minimum 21 -15*
Maximum 27 24
Minimum 16 -20
Maximum 32 43
Minimum 21 -10**
Maximum 27 24
Minimum 16 -10
Maximum 32 43
Minimum 21 -10**
Maximum 32 43
Minimum 21 -5
Maximum 27 24
Minimum 16 -15
Thank you for purchasing
Air Conditioner
TABLE OF CONTENTS
SAFETY PRECAUTIONS
REGULATORY INFORMATION
PRODUCT OVERVIEW & OPERATIONS (WIRELESS REMOTE CONTROL)
PRODUCT OVERVIEW & OPERATIONS (WIRED REMOTE CONTROL)
CARE & CLEANING
TROUBLESHOOTING
QUICK GUIDE
NOTE :
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
BACK COVER
4~5
6~8
10~11
2
ENGLISH
3
9
Information for Users on Collection and Disposal of Old Equipment and used Batteries
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement
Pb
set by the Directive for the chemical involved.
• Do not switch ON the unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
• Do not install the unit in oily and smoky areas.
3
ADDRESS
AUTO
AUTO
TIMER ON
SETRESET ADDRES
S
MODE
MODE
AIR SW
ING
FAN SPEED
AIR SWING
TIMER
OFF/ON
SET
CANCEL
SELECT
CLOCK
FAN SPEED
FILTER RESET
MANUAL
ODOUR WASH
MODE
AUTO
ECONOMY
PRODUCT OVERVIEW & OPERATIONS
PRODUCT OVERVIEW & OPERATIONS
(WIRELESS REMOTE CONTROL)
(WIRELESS REMOTE CONTROL)
Control Panel
Airfl ow direction louver
Air fi lter
Intake grille
Remote control display
3
6
Inverter / Heat-pump Model CZ-RL513B
Cooling Model CZ-RL013B
4
1
POWER TIMER FILTER ECONOMY ODOUR WASH
AUTO
Ray receiver
Auto OFF/ON button
• To operate the unit if the wireless remote control is misplaced or malfunctioning.
Action Mode
Press once. Auto
Air is discharged evenly
Press and hold until you hear 1 beep, then release.
Cooling
1. Press and hold until you hear 2 beeps then release.
2. Press the
button for 5 seconds.
SET
Heating
Press the button to turn off.
Transmitter Maximum distances: 8m
Remote Control Preparation
Press and pull out
1
Insert AAA or R03 batteries
2
(can be used ~ 1 year)
3
Press CLOCK
OFF/ON
TO TURN ON OR OFF THE UNIT
Set time
4
Confi rm
5
Close the cover
6
POWER
TO SET TEMPERATURE
• Selection range: 16°C ~ 31°C.
4
5
MODE
TO SELECT OPERATION MODE
AUTO mode - For your convenience
2
• Unit selects operation mode according to temperature setting, outdoor and room temperature.
HEAT mode - To enjoy warm air
• Unit takes a while to warm up. (Applicable for Inverter / Heat-pump Model)
FAN mode - To enables air circulation in the room COOL mode - To enjoy cool air DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling operation.
• During soft dry operation, the indoor fan operates at a low fan speed.
• The louvers movement might not align with the remote control display.
Loading...
+ 8 hidden pages