PANASONIC CUE7MKE, CUE7MKE3, CUE9MKE, CUE9MKE3 User Manual

CU-E7MKE CU-E7MKE-3 CU-E9MKE
CU-E12MKE
CU-E15MKE CU-E18MKE CU-E21MKE
Multi Split Outdoor Unit
CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE CU-4E27CBPG
QUICK GUIDE GUIDE RAPIDE GUÍA RÁPIDA KURZANLEITUNG GUIDA RAPIDA SNELLE GIDS
QUICK GUIDE GUIDE RAPIDE GUÍA RÁPIDA KURZANLEITUNG GUIDA RAPIDA SNELLE GIDS
Operating Instructions
Air Conditioner
Indoor Unit INVERTER DELUXE XE
CS-XE7MKEW CS-XE9MKEW CS-XE12MKEW CU-E9MKE-3 CS-XE15MKEW CS-XE18MKEW CU-E12MKE-3 CS-XE21MKEW
INVERTER DELUXE E
CS-E7MKEW CS-E9MKEW CS-E12MKEW CS-E15MKEW CS-E18MKEW CS-E21MKEW
ENGLISH 2 ~ 11
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
12 ~ 21
FRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
22 ~ 31
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta.
32 ~ 41
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.
42 ~ 51
ITALIANO
Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro.
NEDERLANDS
Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik.
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010. Unauthorized copying and distribution is a violation of law.
Single Split Outdoor Unit
CU-E12MKE
CU-E15MKE CU-E18MKE CU-E21MKE
Multi Split Outdoor Unit
CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE CU-4E27CBPG
52 ~ 61
F567918
Thank you for purchasing Panasonic Air Conditioner
TABLE OF CONTENTS
Room A
Room B
Room C
Multi Split Outdoor Unit
INDOOR UNIT
TABLE OF CONTENTS
MULTI AIR CONDITIONER SYSTEM 2 OPERATION CONDITION SAFETY PRECAUTIONS REMOTE CONTROL INDOOR UNIT TROUBLESHOOTING 10 INFORMATION QUICK GUIDE
NOTE : The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is
subjected to change without notice for future improvement.
BACK COVER
MULTI AIR CONDITIONER SYSTEM
Multi Split Outdoor Unit (CU-2E15LBE, CU-2E18LBE, CU-3E18LBE, CU-4E23LBE, CU-4E27CBPG)
DEFINITION
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.
INDOOR UNIT
• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the rst unit that turned on.
• During operation, heating and cooling mode could not be activated at the same time for different indoor unit. The power indicator blinks to indicate the indoor unit is standing by for different operation mode.
3 4~5 6~8
9
11
Room C
Room A
Room B
Multi Split Outdoor Unit
* Note: For complete product combination, please refer to catalog.
Caution
PATROL/
operations could be activated even when the air-conditioner is turned off. In this condition, once e-ion indicator is ON, the unit will operate with AUTO fan speed and air swing. However, this operation could not be activated or will be deactivated if other indoor unit is activating heating mode.
2
OPERATION CONDITION
Use this air conditioner under the following temperature range
Single Split Outdoor Unit (CU-E7MKE, CU-E9MKE, CU-E12MKE, CU-E15MKE, CU-E18MKE, CU-E21MKE)
Temperature (°C)
COOLING
HEATING
NOTICE: • This model is not suitable for 24 hours non-stopping operation in heating mode below -5°C. When the outdoor temperature is below -5°C and you use this model out of above conditions, the outdoor unit might be frozen up and stop operation for protection control.
Single Split Outdoor Unit (CU-E7MKE-3, CU-E9MKE-3, CU-E12MKE-3)
Temperature (°C)
COOLING
HEATING
NOTICE: • This model is not suitable for 24 hours non-stopping operation in heating mode below -15°C. When the outdoor temperature is below -15°C and you use this model out of above conditions, the outdoor unit might be frozen up and stop operation for protection control at -18°C.
Max. 32 23 43 26
Min. 16 11 5 4
Max. 30 - 24 18
Min. 16 - -5 -6
Max. 32 23 43 26 Min. 16 11 5 4 Max. 30 - 24 18 Min. 16 - -15 -16
Indoor Outdoor
*DBT *WBT *DBT *WBT
Indoor Outdoor
*DBT *WBT *DBT *WBT
ENGLISH
Multi Split Outdoor Unit (CU-2E15LBE, CU-2E18LBE, CU-3E18LBE, CU-4E23LBE, CU-4E27CBPG)
Outdoor Outdoor
CU-2E15LBE, CU-2E18LBE,
CU-4E27CBPG
Temperature (°C)
COOLING
HEATING
* DBT: Dry bulb temperature * WBT: Wet bulb temperature
Indoor
*DBT *WBT *DBT *WBT *DBT *WBT
Max. 32 23 43 26 46 26
Min. 16 11 16 11 -10 -
Max. 30 - 24 18 24 18
Min. 16 - -10 -11 -15 -16
CU-3E18LBE, CU-4E23LBE
3
SAFETY PRECAUTIONS
WARNING
CAUTION
WARNING
Air Inlet
Air Outlet
Air Outlet
Air Inlet
To prevent personal injury, injury to others, or property damage, please comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or re.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not expose yourself directly to cold air for a long period to avoid excess cooling.
Do not sit or step on the unit, you may fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play with the remote control to prevent them from
Indoor
Unit
Air Inlet
Power
Supply
accidentally swallowing the batteries.
POWER SUPPLY
Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with other equipment.
• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or
Remote
Control
Air Outlet
Air Inlet
pulling out the power plug.
Air Outlet
Outdoor
Unit
4
CAUTION
WARNING
WARNING
POWER SUPPLY
If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re.
To prevent overheating, fi re or electric shock:
• Insert the power plug properly.
• Dust on the power plug should be periodically wiped with a dry cloth.
Stop using the product when any abnormality/ failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock)
Examples of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is switched on for operation.
• The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.
This equipment must be earthed to prevent electrical shock or fi re.
Prevent electric shock by switching off the power supply and unplug when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene, thinner or scouring powder to avoid damage or corrosion at the unit.
Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.
Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re propagation.
Do not expose plants or pet directly to airfl ow to avoid injury, etc.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
Do not install the unit in oily and smoky areas to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to avoid injury.
Do not step onto unstable bench when cleaning the unit to avoid injury.
Do not place vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.
Do not open window or door for long time during COOL/DRY mode operation.
Ensure drainage pipe is connected properly and keep drainage outlet clear of gutters, containers or does not immersed in water to prevent water leakage.
After long period of use or use with any combustible equipment, aerate the room regularly.
After long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.
ENGLISH
To prevent malfunction or damage of the remote control:
• Remove the batteries if the unit is not going to be used for a long period of time.
• New batteries of the same type must be inserted following the polarity stated.
POWER SUPPLY
Do not pull the cord to disconnect the plug to prevent electric shock.
5