SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property damage, please comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
WARNING
WARNING
This sign warns of death or serious injury.
CAUTION
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an action that is COMPULSORY.
WARNING
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
REMOTE CONTROL
Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
Thank you for purchasing
Panasonic Air Conditioner
TABLE OF CONTENTS
TABLE OF CONTENTS
SAFETY PRECAUTIONS
2~3
INFORMATION
3
REMOTE CONTROL
4~5
INDOOR UNIT
6
TROUBLESHOOTING
7
QUICK GUIDE
BACK COVER
NOTE
NOTE
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
OPERATION CONDITION
OPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C)
Indoor
*DBT *WBT
COOLING
Max. 32 23
Min. 16 11
HEATING
Max. 30 -
Min. 16 -
Temperature (°C)
Outdoor
*DBT *WBT
COOLING
Max. 43 26
Min. 16 11
HEATING
Max. 24 18
Min. -15 -16
* DBT: Dry bulb temperature * WBT: Wet bulb temperature
NOTICE: • This model is not suitable for 24 hours non-stopping operation in heating mode below -15°C. When the outdoor temperature is below -15°C and you use this model out of above conditions, the outdoor unit might be frozen up and stop operation for protection control.
Air Inlet
Air Inlet
Air Inlet
Air Inlet
Air Inlet
Air Inlet
Air Outlet
Air Outlet
Air Outlet
Air Outlet
Remote Control
Outdoor
Unit
Indoor
Unit
Air Outlet
Air Outlet
Air
Air
Inlet
Inlet
Power
Supply
3
CAUTION
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene, thinner or scouring powder.
Do not use for other purpose such as preservation of food.
Do not use any combustible equipment in front of the airfl ow outlet to avoid propagation fi re.
Do not expose yourself directly to cold air for a long period.
Do not sit or step on the unit, you may fall down accidentally.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
Do not install the unit in oily and smoky areas. Ensure drainage pipe is connected properly.
Otherwise, leakage may occur. Aerate the room regularly. After long period of use, make sure the
installation rack is not deteriorate to prevent the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.
Remove the batteries if the unit is not going to be used for a long period of time.
New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
WARNING
WARNING
POWER SUPPLY
Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
Do not share the same power outlet with other equipment to prevent overheating and fi re.
Do not operate with wet hands to prevent electric shock.
If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re.
This equipment must be earthed to prevent electrical shock or fi re.
Prevent electric shock by switching off the power supply when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select Cooling/Heating operation, after 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: Cooling: 8°C Heating: 14°C
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
FOR EXTENDED NON-USE
• Activate Heat mode operation for 2~3 hours as an alternative to remove moisture left in the internal parts thoroughly to prevent mould growth.
• Turn off the power supply.
• Remove the remote control batteries.
INFORMATION
Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock)
Examples of abnormality/ failure
• The ELCB trips frequently.
• Burning smell is observed.
Abnormal noise or vibration of the unit is observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is switched on for operation.
• The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.