Panasonic CS-XE9WKUAW, CS-XE12WKUAW, CS-XE15WKUAW, CU-XE9WKUA, CU-XE12WKUA User Manual

...
Operating Instructions
Air Conditioner
Model No. Indoor Unit Outdoor Unit
CS-XE9WKUAW CS-XE12WKUAW CS-XE15WKUAW
CU-XE9WKUA CU-XE12WKUA CU-XE15WKUA
Operating Instructions Air Conditioner
Before operating the unit, please read these operating instructions thoroughly and keep them for future reference. The included Installation Instructions should be kept and read by the installer before installation. Remote control is packaged in the indoor unit and removed by the installer before installation.
Instructions d’utilisation Climatiseur
Avant d’utiliser l’appareil, veuillez lire ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure. Les instructions d’installation incluses doivent être conservées et lues par l’installateur avant l’installation. La télécommande est emballée dans l’unité intérieure et retirée par l’installateur avant l’installation.
2-14
15-28
ACXF55-27111
Français English
ACXF55-27111_FC1219-1.indb 1 11/21/2019 2:56:49 PM
A new built-in Network Adaptor that allows you to
MODE
AIR SWING
TEMP
MODE
RFP
RFP
AIR SWING
TEMP
POWERFUL
FAN SPEED/
QUIET
OFF/ON
AIR SWING
RFP
AIR SWING
AIR SWING
AIR SWING
POWERFUL
FAN SPEED/
QUIET
control your heatpump from everywhere.
Use remote control within 26ft/8m from the remote control receiver of the indoor unit.
Quick Guide
B
A
Inserting the batteries
1
3
Pull out the back cover
1
of remote control.
Insert AAA or R03
2
2
batteries.
Close the cover.
3
2
ACXF55-27111_FC1219-1.indb 2 11/21/2019 2:56:49 PM
A
Clock setting
Press
1
time .
and
• Press and hold for approximately
5 seconds to show time in 12-hour (am/pm) or 24 hour indication.
Confirm
2
set the
.
Thank you for purchasing Panasonic Air Conditioner.
Table of contents
Safety precautions
How to use
To learn more
Cleaning instructions
Troubleshooting
…………
………………………
…………………
…………
………
11-13
4-5
6-7
8-9
10
Information………………… 14
Accessories
• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control holder × 2
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject to change without notice for future improvement.
English
B
Basic operation
Press
1
start/stop the operation.
OFF/ON
to
Press
2
the desired mode.
MODE
MODE
to select
AUTO HEAT
DRY
COOLFAN
Select the desired
3
temperature.
TEMP
TEMP
Up
Down
Selection range (Not
POWER
• Please note that the
indication is on display to start the unit.
applicable for FAN mode): 60 °F ~ 86 °F / 16.0 °C ~ 30.0 °C.
• Press and hold for approximately 10 seconds to switch the temperature indication in °F or °C.
3
ACXF55-27111_FC1219-1.indb 3 11/21/2019 2:56:50 PM
Safety precautions
To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below: This appliances is not intended for accessibility by the general public.
This sign warns of
WARNING
CAUTION
The instructions to be followed are classified by the following symbols:
Indoor unit
Air outlet
Remote control
death or serious injury.
This sign warns of injury or damage to property.
This symbol denotes an action that is PROHIBITED.
These symbols denote actions COMPULSORY.
Power supply
Air inlet
Air inlet
WARNING
Indoor unit and outdoor unit
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove, disassemble and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire.
Confirm with authorised dealer or specialist on usage of any specified refrigerant type. Using refrigerant type other than the specified may cause product damage, burst and injury etc.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by manufacturer. Any unfit method or using incompatible material may cause product damage, burst and serious injury.
Do not install the unit in a potentially explosive or flammable atmosphere. Failure to do so could result in fire.
Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not expose yourself directly to cold air for a long period to avoid excess cooling.
Do not sit or step on the unit, you may fall down accidentally.
Outdoor unit
Air outlet
Remote control
Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
4
ACXF55-27111_FC1219-1.indb 4 11/21/2019 2:56:51 PM
Power supply
Do not use a modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.
To prevent overheating, fire or electric shock:
Do not share the same power outlet with other equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified persons in order to avoid a hazard.
It is strongly recommended to install this unit using an Earth Leakage Circuit Breaker (ELCB) or Ground Fault Interrupt (GFCI) or Appliance Leakage Current Interrupt (ALCI) to prevent electric shock or fire.
Stop using the product if any abnormality/ failure occurs or turn off the power switch and breaker. (Risk of smoke/fire/electric shock) Examples of abnormality/failure
The ELCB or GFCI or ALCI trip frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is observed.
Water leaks from the indoor unit.
Power cord becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it is switched on for operation.
The fan does not stop even if the operation
is stopped. Contact your local dealer immediately for maintenance/repair.
This equipment must be earthed to prevent electrical shock or fire.
Prevent electric shock by switching off the power supply:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with water, benzene, thinner or scouring powder to avoid damage or corrosion at the unit.
Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.
Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation.
Do not expose plants or pet directly to airflow to avoid injury, etc.
Do not touch the sharp aluminium fin, sharp parts may cause injury.
Do not switch ON the indoor unit when waxing the floor. After waxing, aerate the room properly before operating the unit.
Do not install the unit in oily and smoky areas to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to avoid injury.
Do not step onto an unstable bench when cleaning the unit to avoid injury.
Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.
Do not open window or door for long time during operation, it may lead to inefficient power usage and uncomfortable temperature changes.
Prevent water leakage by ensuring drainage pipe is:
- Connected properly,
- Kept clear of gutters and containers, or
- Not immersed in water After a long period of use or use with any
combustible equipment, aerate the room regularly.
After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.
Safety precautions
English
Remote control
Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.
To prevent malfunction or damage of the remote control:
Remove the batteries if the unit is not going to be used for a long period of time.
New batteries of the same type must be inserted following the polarity stated.
5
ACXF55-27111_FC1219-1.indb 5 11/21/2019 2:56:51 PM
How to use
Indicator
RFP
OFF/ON
POWERFUL
TEMP
TEMP
RFP
MODE
MODE
To adjust airflow directionTo adjust airflow direction
Upper direction
AIR SWING
AIR SWING
Lateral direction
• Do not adjust the flap by hand.
To adjust FAN SPEED and QUIET condition
FAN SPEED/
QUIET
FAN SPEED:
• For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
QUIET:
• This operation reduces airflow noise.
To reach temperature quickly
POWERFUL
AIR SWING
FAN SPEED/
QUIET
AIR SWING
• This operation stops automatically after 20 minutes.
To enjoy freshness and cleaner environment
• This operation provides clean air, moisturises your skin and hair, deodorizes odours in the room.
• This operation can be activated when the unit is turn on or off by pressing the nanoe™X button. During nanoe™X individual operation, the fan speed will be
Not used in normal operations.
Press to restore the remote control to default setting.
based on remote control setting.
• If nanoe™X is activated before the unit is turn off, nanoe™X operation will resume once the unit is turn on, this includes to ON Timer.
Press to ON/OFF Wireless LAN features.
6
ACXF55-27111_FC1219-1.indb 6 11/21/2019 2:56:51 PM
See "To learn more..." for details.
To select Room Freeze Protection
RFP
• When selected, the unit will circulate the air in High mode for monitoring the temperature. When the sensor detects the temperature drops below 46 °F / 8 °C the compressor/heat pump operation begins, when the temperature reaches 50 °F / 10 °C, the compressor stops and repeat this cycle.
To connect network
• For Wireless LAN Module operation setup, please refer to Setup Instructions Manual.
To set the timer
2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time.
21 3
• To cancel ON or OFF timer, press or
to select respective or then
press
.
• If timer is cancelled manually or due to power failure, you can restore the timer
or to select
Select ON or OFF
1
timer
• Each time pressed:
(exit setting)
Example: OFF at 22:00
again by pressing respective
or then press .
• The nearest timer setting will be displayed and will activate in sequence.
• Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to
2 Set the time
Quick Guide.
How to useEnglish
3 Confirm
Note
POWERFUL
,
• Can be selected at the same time.
• Can be activated in all modes.
POWERFUL
• POWERFUL, QUIET and FAN SPEED cannot be selected at the same time.
FAN SPEED/
,
QUIET
• Can be cancelled by pressing the respective button again.
7
ACXF55-27111_FC1219-1.indb 7 11/21/2019 2:56:52 PM
To learn more...
Operation mode
AUTO : During operation, the POWER indicator will blinks at initial.
• Unit selects operation mode every 10 minutes according to setting temperature and room temperature.
HEAT : The POWER indicator blinks at the initial stage of this operation. Unit takes a
COOL : Provides efficient comfort cooling to suit your needs. DRY : Unit operates at low fan speed to give a gentle cooling operation. FAN : To circulate air in the room.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT : 68 °F ~ 75 °F / 20.0 °C ~ 24.0 °C. COOL : 79 °F ~ 82 °F / 26.0 °C ~ 28.0 °C.
Air flow direction
In COOL/DRY mode:
If AUTO is set, the flap swings up/down or left/right (subject to feature applicability) automatically.
In HEAT mode:
If AUTO is set, the horizontal flap is fixed at predetermined position. The vertical flap (subject to applicability) swings left/right after temperature rises.
Auto restart control
If power is resumed after a power failure, the operation will restart automatically after a period of time with previous operation mode and airflow direction.
• This control is not applicable when TIMER is set.
while to warm up.
8
ACXF55-27111_FC1219-1.indb 8 11/21/2019 2:56:52 PM
Room Freeze Protection Function (RFP)
Room Freeze Protection function (RFP) is used in spaces that are unoccupied during the winter, for the purpose of protecting any equipment or appliances which may be destroyed as a result of freezing temperature.
ROOM FREEZE PROTECTION FUNCTION (RFP) OPERATION
When the RFP is selected, the unit will operate the fan at high speed for proper room temperature monitoring. When the sensor detects that the room temperature has dropped below 46 °F / 8 °C, the compressor/heat pump operation begins. When the room temperature reaches 50 °F / 10 °C, the unit shuts off, then will repeat continuously if the temperature drops below 46 °F / 8 °C again.
<Disclaimer> This function may not be performed if the unit is not energized, or under a certain condition that unit is unable to operate such as in protection mode. Please consult with the HVAC installers or professional for details.
The Room Freeze Protection function (RFP) cannot be used unless the unit is energized and set into the RFP mode. In the advent of a power failure this mode will not function. During the RFP mode, POWERFUL OPERATION, QUIET OPERATION and FAN SPEED selection are all disabled. Please consult with you HVAC installer or professional for more details.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature (°F/°C)
COOL
HEAT
Max. 89.6/32 73.4/23 114.8/46 78.8/26
Min. 60.8/16 51.8/11 0/-17.8 -/-
Max. 86.0/30 -/- 75.2/24 64.4/18
Min. 60.8/16 -/- -15/-26 -16/-26.7
DBT WBT DBT WBT
roodtuOroodnI
DBT: Dry bulb temperature, WBT: Wet bulb temperature
To learn more...
English
Power Supply
Models Number Time Delay Circuit Breaker Rated Volts
CS-XE9WKUAW / CU-XE9WKUA 15 Amps
208/230VCS-XE12WKUAW / CU-XE12WKUA 20 Amps
CS-XE15WKUAW / CU-XE15WKUA 25 Amps
9
ACXF55-27111_FC1219-1.indb 9 11/21/2019 2:56:52 PM
Cleaning instructions
To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may caused malfunction and you may retrieve error code “H 99”. Please consult authorised dealer.
• Switch off the power at the circuit breaker before cleaning.
• Do not touch the aluminium fin, sharp parts may cause injury.
• Do not use benzine, thinner or scouring powder.
• Use only soap ( detergent.
• Do not use water hotter than 104 °F / 40 °C.
pH 7) or neutral household
Indoor unit
Wipe the unit gently with a soft, dry cloth. Coils and fans should be cleaned periodically by authorised dealer.
Outdoor unit
Clear debris that surround the unit. Clear any blockage from drain pipe.
Air filters
Once every 2 weeks
• Wash/rinse the filters gently with water to avoid damage to the filter surface.
• Dry the filters thoroughly under shade, away from fire or direct sunlight.
• Replace any damaged filters.
Remove air filter Attach air filter
Indoor unit
Front panel
Air filters
Aluminium fin
Front panel
Wash gently and dry.
How to remove front panel
Pull upward
2
Horizontal
Raise over
1
horizontal level
How to fix front panel
Hold horizontally
1
Bend slightly and push to close.
3
2
Match
Insert into the unit
Press both ends and center of the front panel.
4
10
ACXF55-27111_FC1219-1.indb 10 11/21/2019 2:56:52 PM
Loading...
+ 22 hidden pages