Panasonic CU-W18DKR, CS-W24DKR, CU-W24DKR, CS-W18DKE, CU-W18DKE Operating Instructions Manual

...
F564428
Operating Instructions
Air Conditioner
CS-W18DKR CU-W18DKR CS-W24DKR CU-W24DKR
ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 2 ~ 7
Manufactured by:
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
2
(GB Standard)
red black green/yellow
The appliance is not intended for use by young children or infi rm person without supervision. Young children should be supervised to ensure that they do not play with the appliance.
Replacement or installation of power plugs shall be performed by authorized/qualifi ed personnel only. The wires in this mains lead are coloured in accordance with the following code:
Safety Regulation
Different countries may have different colour coding for the wires.
Operation Condition (°C)
Use this air conditioner under the following temperature range.
DBT: Dry Bulb Temperature WBT: Wet Bulb Temperature
Indoor Outdoor
DBT WBT DBT WBT
Maximum Temperature (COOL) 32 23 43 26
Maximum Temperature (HEAT) 30 24 18
Minimum Temperature (COOL) 16 11 16 11
Minimum Temperature (HEAT) 16 -5 -6
This sign warns of death
or serious injury.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classifi ed as below:
This symbol denotes
an action that is
PROHIBITED.
These symbols denote
actions that are
COMPULSORY.
Warning
Definition
This sign warns of injury
or damage to property.
Caution
The instructions to be followed are classifi ed by the following symbols:
Thank you for purchasing Panasonic Air Conditioner
Caution
Warning
• Insert the power plug properly.
• Use specifi ed supply cord.
• If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualifi ed person in order to avoid a hazard.
• Remove the batteries if the unit is not going to be used for a long period of time.
• New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
• In case of emergency or abnormal condition (burnt, smell, etc) occurs, turn off the power supply and unplug.
• Do not share power outlet.
• Do not modify power cord.
• Do not use an extension cord.
• Do not operate with wet hands.
• Do not operate or stop the unit by inserting or pulling out the power plug.
• Do not insert fi nger or other objects into the indoor or outdoor unit.
• Do not attempt to repair the unit by yourself.
• Do not use rechargeable (Ni-Cd) batteries.
• Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries.
• Do not pull the cord to disconnect the plug.
• Do not wash the unit with water, benzene, thinner or scouring powder.
• Do not use for other purposes such as preservation of food.
• Do not use any combustible equipment at airfl ow direction.
• Do not sit or place anything on the indoor or outdoor unit.
• Do not expose directly to cold air for a long period.
• Ventilate the room regularly.
• Pay attention as to whether the installation rack is damaged after long period of usage.
• Switch off the power supply and unplug before cleaning or servicing.
• Turn off the power supply and unplug if the unit is not used for a long period of time.
SAFETY PRECAUTIONS
Operation Precautions
Operation Precautions
Warning
Installation Precautions
Installation Precautions
Do not install, remove and reinstall the unit by yourself.
• Improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.
• This equipment must be earthed and installed with ELCB. It may cause electrical shock or fi re in case of malfunction.
Caution
• This air conditioner must be earthed. Improper grounding will cause electric shock.
• Ensure that the drainage piping is connected properly. Otherwise, water will leak.
• Do not install the unit in a potentially explosive atmosphere.
3
TEMP
MODE
POWERFUL
AIR SWIN
G
FAN SP
EED
QUIET
1
23
TIMER
ON
OFF
CANCEL
SET
COOL
AUTO
AUTO
AUTO
FAN
RES
ET CLOCK
OFF/ON
LCD display
Off/On
Fan speed selection
Memory reset
Clock setting
Temperature setting
Operation mode
Quiet operation
Timer setting
Ion operation
Airflow direction adjustment
Remote Control
Remote Control
Transmitter
Powerful operation
Note: The illustrations in this manual are for explanation purposes only and may differ from the
actual unit. It is subjected to change without notice for future improvement.
Air inlet (rear)
Air outlet
Air inlet (side)
Remote Control Preparation
About
• Timer operation will be based on current time set.
• The batteries can be used for approximately 1 year.
• The batteries must be recycled or disposed of properly.
• Make sure it is not obstructed.
• Maximum distances : 10m.
• Certain fluorescent lights may interfere with signal transmission. Consult your dealer.
Remote Control Signal
• To operate the unit if the remote control is misplaced or malfunctioning.
Action
Operation
mode
Press once
Automatic Operation
Press until “beep”
sound
Cooling
Operation
• To OFF, press again the Auto OFF/ ON button.
• To switch the remote control signal receiving sound off or on.
1. Press until “beep” sound and release.
2. Press again until “beep-beep” sound and release.
3. Press to switch the sound off or on.
(Long “beep”- OFF; short “beep”
- ON)
Auto OFF/ON Button
5. Press again to confi rm
TEMP
MODE
POWERFUL
AIR
SWING
FAN
SPEED
QUIET
1
23
TIM
ER
ON
OFF
CANCEL
SET
O
AUTO
AUTO
FAN
RESET CLOCK
OFF
/ON
1
23
TIMER
ON
OFF
CANCEL
SET
RESET CLOCK
1. Pull out
2. Insert batteries (AAA or R03)
3. Press CLOCK button
4. Set current time
PRODUCT OVERVIEW
Air intake
Airflow direction louver
Air filter
Front panel
Indoor Unit
Indoor Unit
Supersonic air purifying device
Auto OFF/ON button
Receiver
Discharged air
QUIET
POWERFUL
ION
SUPER
ALLERU-BUSTER
TIMERPOWER
Indicator
Outdoor Unit
Outdoor Unit
Troubleshooting
Operation delayed for few minutes after restart.
This is a normal self protection control.
Sound like water owing during operation.
Caused by refrigerant ow inside.
Mist emerges from indoor unit.
Condensation effect due to cooling process.
Noisy during operations.
Installation work could be slanted or front panel didn’t close properly.
Remote control/display does not work.
Check whether batteries are correctly inserted or need replacement.
The unit cannot operate.
Check either circuit breaker is tripped, power plug is inserted correctly or
timer is used correctly.
Outdoor unit emits water/steam.
Condensation or evaporation happens at piping surface.
Ionizer
Do not touch during operation
Loading...
+ 5 hidden pages