Medium Fan Speed
High Fan Speed
Automatic Fan Speed
Vertical Airflow Direction Control
•
AUTO
Automatic Vertical Airflow
Control.
•Manual Vertical Airflow
Control (5 stages of
adjustment).
Powerful Operation Start / Stop
FAN
SPEED
AIR
SWING
OFF
TIMERONTIMER
OFF/ON
FAN SPEED
TEMP
AIR SWING
ON
123
SET
CANCEL
CANCEL
CLOCK RESET
TEMP.
ON-TIMER
OFF-TIMER
▲
▼
SET
CANCEL
CLOCK
Room Temperature Setting
Heating, Cooling, Soft Dry Operation.
• Increase or decrease set temperature
(16°C to 30°C)
Automatic Operation
Operation with 2°C higher than
•
standard temperature.
•Operation with standard temperature.
Operation with 2°C lower than
•
standard temperature.
Timer Operation Selection
• 24-hour, OFF / ON Real Timer Setting.
Time / Timer Setting
• Hours and minutes setting.
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
Clock Setting
• Current time setting.
QUIET
Quiet Operation Start / Stop
Ionizer Operation Start / Stop
4
2.2. Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode. Used when the remote control
cannot be used.
• Press for ≥ 5 second to operate Cooling
operation mode and compressor force to on
(“beep” sound will heard). Used when test
running or servicing.
• Within 20 second of Cooling operation, press
continuously for 5 second to enter various
setting mode. “beep, beep” sound will be heard.
(Used to toggle remote control signal receiving
sound or select remote control transmission
code).
Operation Indication Lamps (LED)
• POWER
• TIMER
• QUIET
• POWERFUL
• ION
• SUPER
(Green) ............. Lights up in operation,
(Orange) ............ Lights up in Timer
(Orange) ............. Lights up in Quiet
(Orange) ...... Lights up in Powerful
(Green) .................. Lights up in Ionizer
ALLERU-BUSTER
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Operation.
Powerful Operation
• Reaches the desired room temperature quickly.
blinks in Automatic
Operation judging and
Hot Start operation.
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
Overload Protector
• OLP to protect the compressor. Overload
Protector will trip when
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit diagram for OLP
characteristic)
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
Deice Control
• To prevent frosting at outdoor heat
exchanger. (Only for Heating Operation)
•
Temperature of outdoor heat exchanger
is sensed by TRS (Thermal Reed Switch).
TRS OFF temperature 4°C.
TRS ON temperature -3°C.
Overload Protection Control
• Outdoor fan stops when indoor heat
exchanger temperature rises to 51°C
and above, and restarts when the indoor
heat exchanger temperature drops to
49°C and below.
• Compressor stop when indoor heat
exchanger temperature reaches 65°C or
above. (Heating Operation Only)
Compressor Protection Control
• If the outdoor fan motor is not running
after compressor starts for 50 secs.,
compressor will stop. (Cooling and Soft
Dry Operation only).
Outdoor Fan Operation Control
• Temperature Fuse.
4-Way Valve Control
• When the unit is switched to “OFF”
during Heating Operation, 4-way valve
stays at Heating position for 5 minutes.
InputW4768
RatedOutputW1530
Fan SpeedLowrpmCooling; 780—
Heating; 840
MediumrpmCooling; 940—
Heating; 940
HighrpmCooling; 1,070815
Heating; 1,220
SuperHighrpmCooling; 1,220—
Heating; 1,220
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
Fin TypeSlit FinCorrugate Fin
Row / Stage(Plate fin configuration, forced draft)
2×152×23
FPI2117
Size (W × H × L)mm610 × 315 × 25.4597.7
RatedOutputW—700
Air CirculationDescriptionCross-flow FanPropeller Fan
MaterialASG20k1PP Resin
MotorTypeInduction (4-poles)Induction (6-poles)
InputW4768
RatedOutputW1530
Fan SpeedLowrpmCooling; 780—
Heating; 840
MediumrpmCooling; 980—
Heating; 980
HighrpmCooling; 1,160815
Heating; 1,310
SuperHighrpmCooling; 1,310—
Heating; 1,310
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
Fin TypeSlit FinCorrugate Fin
Row / Stage(Plate fin configuration, forced draft)
2 × 152 × 23
FPI2117
Size (W × H × L)mm610 × 315 × 25.4597.7
RatedOutputW—900
Air CirculationDescriptionCross-flow FanPropeller Fan
MaterialASG20k1PP Resin
MotorTypeInduction (4-poles)Induction (6-poles)
InputW4773
RatedOutputW1533
Fan SpeedLowrpmCooling; 900—
Heating; 960
MediumrpmCooling; 1,120—
Heating; 1,120
HighrpmCooling; 1,280845
Heating; 1,310
SuperHighrpmCooling; 1,310—
Heating; 1,310
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
Fin TypeSlit FinCorrugate Fin
Row / Stage(Plate fin configuration, forced draft)
2 × 152 × 24
FPI2117
Size (W × H × L)mm610 × 315 × 25.4705.8
Automatic operation can be set using remote control.
•
This operation starts to operate with indoor fan at SLo speed for 25 seconds to judge the intake air temperature.
•
After judged the temperature, the operation mode is determined by referring to the below standard.
•
Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting
•
temperature as shown in below table.
Operation mode will be determine again for judgement after 1 hour of operation, if the room temperature reaches to set
•
temperature and compressor off time is over 7 minutes 30 seconds continuously.
The present operation mode will be continued, if the room temperature does not reach to set temperature (Compressor keeps running)
eventhough after 1 hour from automatic operation mode started.
The operation mode judging temperature and standard setting temperature can be increased by 2°C permanently, by open the
•
circuit of JX1 at indoor electronic controller.
8.5. Operation Control
(For 8.5.1 to 8.5.7 information applies only to Cooling and Soft Dry Operation)
8.5.1. Restart Control (Time Delay Safety Control)
When the thermo-off temperature (temperature which compressor stops to operate) is reached during:-
•
Cooling operation - the compressor stops for 3 minutes (minimum) before resume operation.
−
Soft Dry operation - the compressor stops for 6 minutes (minimum) before resume operation.
−
If the operation is stopped by the remote control, the compressor will not turn on within 3 minutes from the moment operation
•
stop, although the unit is turn on again within the period.
This phenomenon is to balance the pressure inside the refrigerant cycle.
•
8.5.2. 60 Seconds Forced Operation
Once the air conditioner is turned on, the compressor will not stop within 60 seconds in a normal operation although the intake
•
air temperature has reached the thermo-off temperature. However, force stop by pressing the OFF/ON operation button at the
remote control is permitted.
The reason for the compressor to force operate at minimum 60 seconds is to allow the refrigerant oil run in a full cycle and
•
return back to the outdoor unit.
8.5.3. 7 Minutes Time Save Control
The compressor will start automatically if it has stopped for 7 minutes and the intake air temperature falls between the
•
compressor ON temperature (A) and compressor OFF temperature (B) during the period.
This phenomenon is to reduce the built up humidity inside a room.
This operation is to prevent the Cold Draft during Heating mode operation.
•
The operation will start when compressor OFF (Thermo OFF) during Heating operation.
•
For the first 30 sec. from compressor OFF (Thermo OFF), Indoor fan speed will operate accordingly to the Indoor heat
•
exchanger temperature as shown below:
After 30 sec. from compressor OFF (thermo OFF), Indoor fan will run at SSLo speed only.
•
Anti Cold Draft Control will stop when:
•
Intake temperature < set temperature. (Time Delay Safety Control 4 minutes waiting is valid)
−
30 Minutes Time Save Control activates.
−
8.5.16. Deicing Control
Deice starts to prevent frosting at outdoor heat exchanger.
Normal Deicing
•
Deice operations detection commences after 30 minutes of Heating operation starts or 60 minutes after previous deice
operation. If the TRS (Thermal Reed Switch) senses the outdoor piping temperature drops to -3°C (TRS CLOSE) or less for
50 sec. continuously during compressor is in operation, deice will start.
(There is no detection during Outdoor Fan stops.)
Overload Deicing
•
During heating operation, if the outdoor Fan OFF duration (due to overload control) is accumulated up to 60 minutes and
after compressor starts for 1 minutes, deicing starts.
Deicing ends when
•
1. 12 minutes after deicing operation starts;
2. TRS senses the outdoor piping temperature rises to 4°C (TRS OPEN).
Deicing will not end immediately as time delay (Td) is valid as shown below.
Once deicing operation starts, it will not end for 60 seconds.
•
After deicing operation, compressor stops for 30 seconds and 4-way valve stays at cooling position for 10 seconds.
•
28
Loading...