This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below;
refer to these descriptions when using the air conditioner.
• Microprocessor Controlled Operation
The interior compartment of the remote controller contains
several features to facilitate automatic operation, easy
logically displayed for easy use.
• Simple One-touch Remote Controller
The remote controller has several features to facilitate
automatic operation.
• 24-Hour ON or OFF Timer
This timer can be set to automatically turn the unit on or off
at any time within a 24 hour period.
• 1-Hour OFF Timer
This timer can be set to automatically turn off the unit at
any time after one hour.
• Night Setback
This function saves energy by controlling operation to
provide a quieter operating sound than normal.
3. Adjusting the Fan Speed............................................ 10
4. Night Setback Mode................................................... 10
5. HIGH POWER Mode.................................................. 10
• Air Sweep Control
This function moves a flap up and down in the air outlet,
directing air in a sweeping motion around the room and
providing comfort in every corner.
• Auto. Flap Control
This automatically sets the flap to the optimum position
during heating, cooling, and drying operation.
• Hot Start Heating System
Right from the start, the air is warm and comfortable. This
system prevents any cold blasts at the beginning while the
heat pump is warming up, or even defrosting.
• Automatic Restart Function for Power Failure
Even when power failure occurs, preset programmed
operation can be reactivated once power resumes.
• High Power Operation
If not in Auto Operation, the unit operates at maximum
output for 30 minutes, regardless of the desired
temperature.
The fan speed is 1 step above “High”.
Page
SPECIAL REMARKS ................................................................11
SETTING THE TIMER ..............................................................11
USING THE 1-HOUR OFF TIMER ...........................................13
TIPS FOR ENERGY SAVING ...................................................13
ADJUSTING THE AIRFLOW DIRECTION ...............................13
OPERATION WITHOUT THE REMOTE CONTROLLER..........14
CARE AND CLEANING ............................................................14
If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate on the bottom of
the cabinet.
Model No. __________________________________
Serial No. ___________________________________
Date of purchase _____________________________
Dealer’s address _____________________________
Phone number _______________________________
2
SAFETY PRECAUTIONS
The following symbols used in this manual, alert you
to potentially dangerous conditions to users, service
personnel or the appliance:
This symbol refers to a hazard or unsafe
practice which can result in severe
personal injury or death.
This symbol refers to a hazard or unsafe
practice which can result in personal
injury or product or property damage.
INSTALLATION LOCATION
NOTE
CAUTION
NOTICE
• We recommend that this air conditioner be installed
properly by qualified installation technicians in
accordance with the Installation Instructions
provided with the unit.
• Before installation, check that the voltage of the electric
supply in your home or office is the same as the voltage
shown on the nameplate.
• Do not install this air conditioner
where there are fumes or flammable
gases, or in an extremely humid space
such as a greenhouse.
• Do not install the air conditioner where
excessively high heat-generating
objects are placed.
Avoid:
To protect the air conditioner from heavy corrosion, avoid installing
the outdoor unit where salty sea water can splash directly onto it or
in sulphurous air near a spa.
ELECTRICAL REQUIREMENTS
1. All wiring must conform to the local electrical codes.
Consult your dealer or a qualified electrician for details.
2. Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring.
3. Wiring must be done by a qualified electrician.
Pull off the power plug from a receptacle, or switch off the breaker, or
switch off the power disconnecting mean to isolate the air conditioner
from the main power supply when not in use for a long time.
• To prevent possible hazards from insulation failure,
the unit must be grounded.
• Do not clean inside the indoor and outdoor units by users.
Engage authorized dealer or specialist for cleaning.
• In case of malfunction of this appliance, do not repair by
yourself. Contact to the sales dealer or service dealer for a
repair.
• Refrigerant gas leakage may cause fire.
• For safety, be sure to turn the air conditioner off and
also to disconnect the power before cleaning.
• Pull off the power plug from a receptacle, or switch off the
breaker, or switch off the power disconnecting mean to
isolate the air conditioner from the main power supply in
case of emergency.
• Do not turn the air conditioner on and off from the power
mains switch. Use the ON/OFF operation button.
• Do not stick anything into the air outlet of the outdoor unit.
This is dangerous because the fan is rotating at high
speed.
• Do not touch the air inlet or the sharp aluminum fins
of the outdoor unit. You may get injured.
• Keep the fire alarm and the air outlet at least 1.5m away from
the unit.
• Do not let children play with the air conditioner.
• Do not cool or heat the room too much if babies or invalids
are present.
• Do not sit or step on the unit. You may fall down
accidentally.
• Do not stick any object into the FAN CASE.
You may be injured and the unit may be damaged.
SAFETY INSTRUCTIONS
• Read this Instruction Manual carefully before using
this air conditioner. If you still have any difficulties
or problems, consult your dealer for help.
• This air conditioner is designed to give you
comfortable room conditions. Use this only for its
intended purpose as described in this Instruction
Manual.
• Confirm to authorized dealer or specialist on usage of
specified refrigerant type.
Using of refrigerant other than the specified type may cause
product damage, burst and injury etc.
• Never touch the unit with wet hands.
• Never use or store gasoline or other flammable vapor or
liquid near the air conditioner — it is very dangerous.
• Do not use this appliance in a potentially explosive
atmosphere.
• This air conditioner has no ventilator for intaking fresh air
from outdoors. You must open doors or windows frequently
when you use gas or oil heating appliances in the same
room, which consume a lot of oxygen from the air.
Otherwise there is a risk of suffocation in an extreme case.
• Do not swallow the battery.
• After removing the battery from remote controller, keep it
away from the reach of children. The battery can cause
death by suffocation if swallowed.
• When inserting the battery, make sure the polarities
(+ and -) are correct.
• This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
• This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules.
These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
• FCC Caution: To assure continued compliance, follow the
attached installation instructions. Any changes or modifications
not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment.
3
NAMES OF PARTS
INDOOR UNIT
Air Intakes
Remote Controller
Refrigerant Tubes
Drain Hose
OUTDOOR UNIT
Air Outlet
Air Outlet!
(4 locations)
NOTE
NOTE
This illustration is based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner
which you have selected.
This air conditioner consists of an indoor unit and an outdoor unit.
You can control the air conditioner with the remote controller.
UNIT DISPLAY AND OPERATION
BUTTON
INDOOR UNIT
OPERATION button
OPERATION lamp
TIMER lamp
HIGH POWER lamp
REMOTE CONTROL receiver
IMPORTANT
Avoid using radio equipment such as mobile phone near (within
4 ft. (1.2 m)) the remote control receiver. Some radio equipment
may cause malfunction of the unit.
If the trouble happens, disconnect power and restart the air
conditioner after a few minutes.
REMOTE
CONTROL
receiver
OPERATION
button
This section picks up infrared signals from the
remote controller (transmitter).
When the remote controller cannot be used,
pressing this button enables heating and
cooling operation.
Each time this button is pressed, the type of
operation conducted is indicated by the
changing color of the OPERATION lamp. Press
the button and select the lamp color that suits
your preference for operation.
Cooling
operation
(green)
Heating
operation
(red)
Stop
(lamp off)
Air Intake
Air Outlet
Remote
Controller
Refrigerant
Tubes
Drain Hose
Outdoor
(Condensing)
Unit
4
Air from the room is drawn into this section and
passes through air filters which remove dust.
Conditioned air is blown out of the air
conditioner through the air outlet.
The remote controller controls power ON/OFF,
operation mode selection, temperature, fan
speed, timer setting, and air sweeping.
The indoor and outdoor units are connected by
copper tubes through which refrigerant gas
flows.
Moisture in the room condenses and drains off
through this hose.
The outdoor unit contains the compressor, fan
motor, heat exchanger coil, and other electrical
components.
OPERATION
lamp
TIMER lampThis lamp lights when the system is being
HIGH POWER
lamp
The unit’s display lamps are dimmed during operation in the NIGHT
SETBACK mode.
This lamp lights when the system is in the
continuous AUTO (red or green), HEAT (red),
DRY (orange) and COOL (green) mode.
The OPERATION lamp lights up red and orange
alternately when the system is defrosting.
controlled by the timer.
This lamp lights during operation in the HIGH
POWER mode.
REMOTE CONTROLLER (DISPLAY)
Displayed when the time
display is set to 12-hour
time.
Symbols
Displayed when transmitting data
Displayed when indoor unit sensor is
in use
Displayed when setting temperature
Displayed when temperature is shown
Displayed when setting timer
(1) Operation mode
AUTO .....................................
HEAT ......................................
MILD DRY ..............................
COOL .....................................
(2) Fan speed
Automatic operation ...............
HIGH .....................................
MEDIUM.................................
(4) Timer
24-hour clock with ON/OFF
program Timer .......................
ON Timer. ..............................
OFF Timer. ............................
1-hour OFF Timer..................
(5) NIGHT SETBACK..................
(6) Confirmation
of transmission.......................
(7) Auto. flap indication................
LOW .......................................
(3) Temperature setting
60–86°F
When set to 80 °F
temperature indication............
Flap angle indication..............
Sweep indication....................
(8) High power operation.............
5
REMOTE CONTROLLER
NOTE
NOTE
Transmitter
When you press the buttons on the remote controller, the mark
appears in the display to transmit the setting changes to the receiver
in the air conditioner.
Display
Information on the operating conditions is displayed while the remote
controller is switched on. If the unit is turned off, FLAP setting and
FAN SPEED setting are not displayed.
HIGH POWER button
: If this button is pressed during HEAT, DRY or COOL operation, the
unit operates at maximum output for 30 minutes, regardless of the
desired temperature.
The fan speed is 1step above ‘‘HIGH’’.
FAN SPEED selector button
: The air conditioner automatically decides the fan speeds.
: High fan speed
: Medium fan speed
: Low fan speed
FLAP button
Press this button either to select the setting of the airflow direction to the auto.
flap in each mode or one of the six possible positions manually or to select the
sweep function which moves the flap up and down automatically.
: Auto flap setting: If selected in a heating operation, the flap is set to
position (3) in the following chart. If selected in a cooling or dry
operation, the flap is set at position (7) in the following chart.
: The airflow direction can be set manually. (six positions)
: The flap moves up and down automatically.
When you press the FLAP button, the air flow direction will be changed one by
one as follows.
SWEEP
ON TIME/OFF TIME setting buttons
Advance button
Return button
No display: The timer does not operate.
: The air conditioner starts at the set time.
: The air conditioner stops at the set time.
: The air conditioner stops and starts, or starts and
stops, at the set times every day. For details, see
“SETTING THE TIMER”.
CANCEL button
SENSOR button
When you press this button (use a small-tipped object such as a ballpoint
pen), the mark will appear at the display. And the room temperature is
detected by the sensor which is built into the indoor unit and the air
conditioner is controlled accordingly.
If the remote controller is located near a heat source, such as a space
heater or in direct sunlight, press the SENSOR button to switch to the
sensor on the indoor unit.
ADDRESS switch
• The address switch changes to prevent mixing of signals from remote controller’s when
two air conditioners are installed next to each other. Normally, the address switch is set
to A. For more information, please contact the dealer where you made the purchase.
• Normally, the tabs on the remote controller should not be bent.
6
Temperature display selector button
This switches the temperature display
between °C and °F.
Sensor
NOTE
A temperature sensor inside the remote controller senses the room
temperature.
ON/OFF operation button
This button is for turning the air conditioner on and off.
1 HR. TIMER button (1-HOUR OFF TIMER)
: When you press this button, regardless of whether the unit is operating
or stopping, the unit operates for one hour and then shuts down.
Temperature setting buttons (TEMP.)
Press the button to increase the set temperature.
Press the button to reduce the set temperature.
The temperature setting changes by 1 °C or 2 °F each time one of the TEMP.
buttons is pressed.
MODE selector button
Use this button to select AUTO, HEAT, DRY or COOL mode.
(AUTO): When this setting is selected, the air conditioner calculates the
difference between the thermostat setting and the room
temperature and automatically switches to the ''COOL'' or
''HEAT'' mode as appropriate.
(HEAT): The air conditioner makes the room warmer.
(DRY): The air conditioner reduces the humidity in the room.
(COOL): The air conditioner makes the room cooler.
NIGHT SETBACK button
For details, see “4. Night Setback Mode”. When you press this button in the
HEAT, DRY or COOL mode, the mark appears in the display, and the
remote controller will automatically adjust the set temperature to save energy.
CLOCK button
Time display selector button
This switches the time display between 24-hour time and 12-hour time.
ACL button (ALL CLEAR)
Puts the remote controller into pre-operation status. Always press this button
after replacing the batteries.
(Cover closed)
• The illustration above pictures the remote controller after the cover has been opened.
• The remote controller sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the
remote controller stops for more than 15 minutes due to the loss of the remote controller or other trouble, the air conditioner will
switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the
temperature around the remote controller may differ from the temperature detected at the air conditioner’s position.
• The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is
reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow.
7
USING THE REMOTE CONTROLLER
ACL button
CAUTION
Pb
NOTE
Air Conditioner
(Indoor unit)
Receiver
Remote Controller
(Transmitter
head)
HOW TO INSTALL BATTERIES
1. Slide the cover in the direction indicated by the arrow and remove
it.
2. Install two AAA alkaline batteries. Make sure the batteries point in
the direction marked in the battery compartment.
3. Use a thin object such as the tip of a pen to press the ACL button.
• The batteries last about six months,
depending on how much you use the
remote controller. Replace the
batteries when the remote controller’s
display fails to light, or when the
remote controller cannot be used to
change the air conditioner’s settings.
• Use two fresh leak-proof type-AAA
alkaline batteries.
• In replacing batteries, follow the
instructions as mentioned in the
subsection “HOW TO INSTALL
BATTERIES”.
• If you do not use the remote controller
more than 1 month, take out the
batteries.
• Dispose of the used batteries at the
designated location in compliance
with the applicable local ordinances.
Information for Users on Collection and Disposal
of Old Equipment and used Batteries
[Information on Disposal in other Countries
outside the European Union]
These symbols are only valid in the European Union.
If you wish to discard these items, please contact
your local authorities or dealer and ask for the correct
method of disposal.
HOW TO USE THE REMOTE CONTROLLER
When using the remote controller, always point the unit’s transmitter
head directly at the air conditioner’s receiver.
REMOTE CONTROLLER INSTALLATION
POSITION
The remote controller may be operated either from a non-fixed
position or from a wall-mounted position. To ensure that the air
conditioner operates correctly, do not install the remote controller in
the following places:
• In direct sunlight
• Behind a curtain or other places where it is covered
• More than 26 ft.(8 m) away from the air conditioner
• In the path of the air conditioner’s airstream
• Where it may become extremely hot or cold
• Where it may be subject to electrical or magnetic noise
• Where there is an obstacle between the remote controller and air
conditioner (since a check signal is sent from the remote controller
every 5 minutes)
MOUNTING THE REMOTE CONTROLLER
Before mounting the remote controller, press the ON/OFF operation
button at the mounting location to make sure that the air conditioner
operates from that location. The indoor unit should make a beeping
sound to indicate that it has received the signal.
Rear Side
Remote Control Holder
Press
S/M (Single/Multiple switch)
• Initially, the S/M switch is set to S (Single).
• Set this switch to M (Multiple) for multiple operation.
• Always press ACL button by a thin object such as the tip of a pen
after setting the S/M switch.
When multiple indoor units are used and units in other rooms are
already operating, they will be operating with the same mode as the
operating indoor units.
8
Note for the battery symbol (bottom two symbol
examples):
This symbol might be used in combination with a
chemical symbol. In this case it complies with the
requirement set by the Directive for the chemical
involved.
Set in
place
Mounting Screws
5/32 x 5/8"
(4 x 16 mm)
(included)
To take out the remote controller, pull it forward.
• To prevent loss of the remote
controller, you can connect the
remote controller to the holder by
passing a string through the remote
controller and attachment hole.
Hole
WHEN HOLDING THE REMOTE CONTROLLER
• When using the remote controller and during air conditioner
operation, the transmitter on the remote controller should be
pointed towards the receiver on the indoor unit.
• Make sure that there are no objects between the remote controller
and receiver which could block the signal.
OPERATION WITH THE REMOTE CONTROLLER
NOTE
NOTE
NOTE
NOTE
1. Automatic Operation
The air conditioner calculates the difference between the thermostat
setting and room temperature, and automatically determines the
mode to operate under cooling or heating. Then, the air conditioner
continuously operates under the mode selected at initial operation.
STEP 2
STEP 1
2. Manual Operation
STEP 4
STEP 5
Check that the circuit breaker on the power panel is
turned on.
If the automatic operation settings of the unit do not
meet your needs, press the setting buttons as
described below and change the settings as desired.
STEP 2
STEP 3
STEP 1
Check that the circuit breaker on the power panel is
turned on.
Once mode is selected and the unit is preset by
following the steps below, you can have the air
conditioner automatically bring the room to the desired
temperature simply by pressing the ON/OFF operation
button.
STEP 1Press the MODE selector button to .
STEP 2Press the ON/OFF operation button.
To stop the air conditioner, press the ON/OFF operation
button again.
• To change the temperature setting; press the
temperature setting buttons and change the setting to
the desired temperature.
STEP 1Press the MODE selector button
STEP 2To start the air conditioner, press the ON/
STEP 3Press the TEMP. setting buttons to change
STEP 4Set the FAN SPEED selector button to the
STEP 5Press the FLAP button and set the airflow
To stop the air conditioner, press the ON/OFF
operation button again.
• When multiple indoor units are used and units in other
rooms are already operating, they will be set to the
same mode of operation as the operating indoor units.
• Choose the best position in the room for the remote
controller, which also acts as the sensor for room
comfort and transmits the operating instructions.
Once you’ve found this best position, always keep the
remote controller there.
• This appliance has a built-in 5-minute time delay
circuit to ensure reliable operation. When the
operation button is pressed, the compressor will start
running within three minutes. In the event of power
failure, the unit will stop.
and select the desired mode.
For heating operation
For dehumidifying operation
For cooling operation
OFF operation button.
the temperature setting to the desired
temperature.
Adjustable temperature range:
30 °C max.
16 °C min.
setting you want.
direction as desired.
(Refer to “ADJUSTING THE AIRFLOW
DIRECTION” on page 13.)
or86 °F max.
60 °F min.
o
o
o
9
3. Adjusting the Fan Speed
When the night setback mode is selected, the air conditioner
automatically raises the temperature setting 2 °F when 30 minutes
have passed after the selection was made, and then another 2 °F
after another 30 minutes have passed, regardless of the indoor
temperature when night setback was selected. This enables you
to save energy without sacrificing comfort. This function is
convenient when gentle cooling is needed.
Setting
temperature
Press the NIGHT
SETBACK button
30 min.
30 min.
Time
2°F
2°F
When the night setback mode is selected, the air conditioner
automatically lowers the temperature setting 4 °F when 30
minutes have passed after the selection was made, and then
another 4 °F after another 30 minutes have passed, regardless of
the indoor temperature when night setback was selected. This
enables you to save energy without sacrificing comfort. This
function is convenient when gentle heating is needed.
Setting
temperature
Press the NIGHT
SETBACK button
30 min.
30 min.
Time
4°F
4°F
NOTE
A. Automatic fan speed
Simply set the FAN SPEED selector button to the
position.
This automatically sets the best fan speed for the room
temperature.
B. Manual fan speed
If you want to adjust fan speed manually during operation,
just set the FAN SPEED selector button as desired. [,
, or ]
4. Night Setback Mode
B. In Heating Mode: ()
5. HIGH POWER Mode
Night Setback Mode is used for saving energy.
Press the NIGHT SETBACK button while unit is operating.
The mark appears in the display.
To release the night setback function, press the NIGHT SETBACK
button again.
A. In Cooling and DRY Mode: (and )
HIGH POWER mode can be used to increase the output of the
indoor unit for all operation modes except automatic operation.
Press the HIGH POWER button while unit is operating.
The mark appears in the display.
To cancel, press HIGH POWER button again.
• When the HIGH POWER button is pressed, the unit operates at
maximum output for 30 minutes, regardless of the desired
temperature. The fan speed is 1 step above “High”.
• HIGH POWER Mode cannot be used when the operation mode is
in Automatic Operation.
• When set to High fan speed during heating operation, the fan runs
at High fan speed even though the mark is displayed.
• Depending on the operating conditions, the fan speed may be
increased by a small amount only.
10
SPECIAL REMARKS
‘‘DRY’’ () Operation
Heating () Operation
Cooling ( ) operation
Power failure during operation
Clicking Sound
Remote Controller
NOTE
How it works?
• Once the room temperature reaches the level that was set, the
unit’s operation frequency is changed automatically.
• During DRY operation, the fan speed automatically runs at lower
speed for providing a comfortable breeze.
• ‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F
or less.
Heating performance
• Because this air conditioner heats a room by drawing in the heat of
the outside air (heat pump system), the heating efficiency will fall
off when the outdoor temperature is very low. If sufficient heat
cannot be obtained with this air conditioner, use another heating
appliance together with it.
Defrosting
• When the outdoor temperature is low, frost or ice may form on the
heat exchanger coil, reducing heating performance. When this
happens, a microcomputer defrosting system operates. At the
same time, the fan on the indoor unit stops and the OPERATION
lamp lights red and orange alternately until defrosting is completed.
Heating operation restarts after several minutes. (This interval will
vary slightly depending upon the outdoor temperature and the way
in which frost forms.)
Cold draft prevention
• For several minutes after the start of heating operation, the indoor
fan runs at a lower speed until the indoor heat exchanger coil has
warmed up sufficiently. However, the fan may remain stopped when
the room temperature is low. This is because the COLD DRAFT
PREVENTION SYSTEM is in operation.
SETTING THE TIMER
In the descriptions below, the following settings are used for the
temperature and time indicator selector button on the bottom front
section of the remote controller.
• Temperature: °F
• Time: AM, PM
1. How to set the present time
(Example) To set to 10:30 pm.
• Sometimes the indoor unit may not get to the set fan speed such as
LOW under cool operation at very low outdoor temperatures due to
the indoor unit being protected from ice or frost.
• In the event of power failure, the unit will stop. When the power is
resumed, the unit will restart automatically in approximately
15 minutes by the remote controller.
Clicking sound is heard from the air conditioner
• In heating or cooling operation, any plastic parts may expand or
shrink due to a sudden temperature change. In this event, a
clicking sound may occur. This is normal, and the sound will soon
disappear.
• The remote controller sends the setting condition to the air
conditioner regularly at five minute intervals.
OperationIndication
1. Press the CLOCK button
once if the time indicator is
not flashing.
2. Press the Advance, Return
( , ) button until PM 10:30
is displayed.
3. Press the CLOCK button
again.
The time indication alone
flashes.
The time can be set in 1-minute
increments. Holding down the
button advances the time rapidly
in 10-minute increments.
This completes the setting of the
current time.