Indoor Unit
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Cooling : Fan rotates at Hi, Me and
Lo- speed. Deodorizing
control is available.
– Soft Dry: Fan rotates at Lo- speed.
Deodorizing control
is available.
• Automatic air swing and manual adjusted
by remote control for vertical and
horizontal airflow.
Airflow Direction Control
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
•
POWER
(Green) ........ Lights up in operation,
blinks in Automatic
Operation Mode
judging.
•
QUIET
(Orange) ........ Lights up in Quiet
Mode Operation.
•
TIMER
(Orange) ....... Lights up in Timer
Setting.
•
POWERFUL
(Orange) .. Lights up in Powerful
Mode Operation.
•
(Green) ........... Lights up in Ionizer
Mode Operation.
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Time Delay Safety Control
•
Restarting is inhibited for appro. 3 minutes.
Quiet Operation
• To provide quiet operation.
7 Minutes Time Save Control
• Cooling Operation only.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor
unit discharge area.
4
CS-C18CKV CU-C18CK V / CS-C24 CKV CU- C24CKV