Before using your air conditioner, please read
this operating instructions carefully and keep it
for future reference.
FEATURES
● Self-illuminating Button
For your convenience to operate in the dark.
(Refer page 4)
● Automatic Operation
Sense indoor temperature to select the optimum
mode.
(Refer page 5)
● Sleep Mode
Prevent the room from getting too hot or too cold
while you are sleeping.
(Refer page 7)
● Economy Mode
To reduce electrical power consumption.
(Refer page 7)
● Powerful Mode
Reaches the desired room temperature quickly.
(Refer page 7)
● Removable Front Panel
For quick and easy cleaning. (washable)
(Refer page 8)
● Catechin Air Purifying Filter
Filter that can trap dust, tobacco smoke and tiny
particles in the room. It can also prevent growth of
bacteria and viruses trapped in this filter.
(Refer page 8)
● Solar Refreshing Deodorizing Filter
Used to remove unpleasant odour and deodorize the
air in the room.
(Refer page 8)
● Auto Restart Control
Restart the unit automatically after power failure.
(Refer page 9)
● Blue Coated Condenser At Outdoor Unit
This is the most advanced anti-rust coating.
! Warning
1) Operate your air conditioner from a stable 208/230 volts
AC supply.
2)
Plug into a separate 15 amps (CS-C18BKP/CU-C18BKP6) or
20 amps (CS-C24BKP/CU-C24BKP6) grounded outlet only.
3) Use of extension cords.
Avoid using extension cords. If there are no alternatives,
ensure that the cord is a UL listed 3-wire grounding type,
rated 250 volt with a minimum current-carrying rating of 15
amps (CS-C18BKP/CU-C18BKP6) or 20 amps
(CS-C24BKP/CU-C24BKP6), number 14 (CS-C18BKP/
CU-C18BKP6), number 12 (CS-C24BKP/CU-C24BKP6)
or a heavier wire.
4) Use a 15 amps (CS-C18BKP/CU-C18BKP6) or 20 amps
(CS-C24BKP/CU-C24BKP6) time delay fuse or a circuit
breaker.
5) Do not switch off by unplugging the power plug while it is
operating. Turn off the air conditioner by using remote
control, before unplugging.
6) Remove power plug or disconnect from the main before
servicing this appliance.
7) Do not repair by yourself.
In case of malfunction of this appliance, do not repair by
yourself. Contact the sales dealer or service dealer for a
repair.
8) Turn off the power (Isolation from main power supply).
Pull off the power plug from the receptacle, or switch off the
breaker, or switch off the power disconnecting mean to
isolate the equipment from the main power supply in case of
an emergency.
! Caution
DISCONNECT THE MAIN PLUG FROM THE SUPPLY
SOCKET WHEN NOT IN USE, WHERE SUPPLY
CONNECTION IS VIA MAIN PLUG.
POWER SUPPLY
Time Delay Fuse:Line Cord Plug:
15 Amps (CS-C18BKP/
20 Amps (CS-C24BKP/
Rated Volts:Socket Type:
CU-C18BKP6)
CU-C24BKP6)
208/230 V
(CS-C18BKP/
CU-C18BKP6)
(CS-C24BKP/
CU-C24BKP6)
1
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
● To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
● Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
! Warning
This sign warns of death or serious injury.
■ Installation Precautions
! Warning
● Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
! Caution
ENGLISH
■ Operation Precautions
! Warning
This sign warns of death or serious injury.
● Do not share outlet.
● Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
● Do not operate with wet hands.
● Do not damage or modify the power cord.
● Do not insert finger or other objects into the
indoor or outdoor units.
● Do not expose directly to cold air for a long
period.
! Caution
This sign warns of damage to property.
● The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
FF
O
These symbols (with a black background) denote
actions that are COMPULSORY.
● This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
● Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
● Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
● Plug in properly.
● Use specified power cord.
FF
O
● If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power
supply.
! Caution
This sign warns of injury.
● Do not pull the cord to disconnect the plug.
● Do not wash the unit with water.
● Do not use for other purposes such as
preservation.
● Do not use any combustible equipment at
airflow direction.
● Do not sit or place anything on the outdoor
unit.
● Switch off the power supply before cleaning.
● Ventilate the room regularly.
● Pay attention as to whether the installation
rack is damaged after long period of usage.
OFF
● Switch off the power supply if the unit is not
used for a long period.
2
NAME OF EACH PART
■ Indoor Unit
1 Front Panel
2 Air Intake Vent
3 Power Supply Cord
4 Air Outlet Vent
5 Vertical Airflow Direction Louver
6 Horizontal Airflow Direction Louver
7 Indicator Panel
● Indoor Unit
(when the front panel is opened)
1 Front Panel
2 Air Filters
3 Air Purifying Filter
■ Outdoor Unit
■ Accessories
● Remote Control
● Remote Control Holder
● Two RO3 (AAA) dry-cell batteries or equivalent
● Air Purifying Filter
1 Auto Operation Button
(when the front panel is opened)
2 Economy Mode Indicator–GREEN
3 Powerful Mode Indicator–ORANGE
4 Power Indicator–GREEN
5 Sleep Mode Indicator–ORANGE
6 Timer Mode Indicator–ORANGE
3
1 Air Intake Vents
2 Ground Terminal
(Inside cover)
3 Piping
4 Connecting Cable
5 Drain Hose
6 Air Outlet Vents
(Catechin Air Purifying Filter)
(Solar Refreshing Deodorizing Filter)
NAME OF EACH PART
CHECK
TEMP
AUTO
ON
OFF
AUTODRY FANCOOL
FAN
AUTO
AUTO
RESET CLOCK
MODE
SLEEP
ECONOMY
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
OFF/ON
POWERFUL
#
!
$
%
^
$
*
&
3
5
8
7
9
0
6
4
(
AUTO
OF
AUTOHEAT
DRY
FANCOOL
FAN
AUTO
AUTO
● How to Insert the Batteries
ENGLISH
■ Remote Control
1
2
● Remote Control Signal.
● Notes for Remote Control.
• Make sure it is not obstructed.
• Maximum distance : 10 m (32.8 ft.).
• Signal received sound.
One short beep or one long beep.
• Do not throw or drop.
• Do not get it wet.
• Certain type of fluorescent lamps may affect
signal reception. Consult your dealer.
1 Signal Transmitter
2 Operation Display
3 Powerful Mode Operation Button
4 Room Temperature Setting Button
CHECK
(self-illuminating button)
5 Operation Mode Selection Button
6 Economy Mode Operation Button
7 Vertical Airflow Direction Button
8 ON-Timer Button
1 Slide down the remote control cover completely
9 OFF-Timer Button
2 Insert the batteries
0 Reset Point
(Press with fine-tipped object to clear the memory)
! OFF/ON Button
(self-illuminating button)
@ Sleep Mode Operation Button
# Fan Speed Selection Button
$ Horizontal Airflow Direction Button
% Timer Set Button
^ Timer Cancellation Button
& Time-Setting Button
* Clock Button
( Remote Control Cover
– Be sure the direction is correct
– 12.00 at display - flashing
• Set the current time (CLOCK) immediately to
prevent battery exhaustion.
● About the batteries
• Can be used for approximately one year.
● Observe the following when replacing the
batteries
• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be
used for a long period.
4
PREPARATION BEFORE OPERATION
CHECK
AUTO
AUTOHEATDRYFANCOOL
FAN
AUTO
RESET CLOCK
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
1
2
OFF
ON
HEAT
DRY
FANCOOL
CHECK
TEMP
AUTO
AU
T
UTO
FA
N
AN
AU
T
UTO
AUTUTO
R
ESET
CLO
C
K
AIR SWING
OFF
CANCEL
1
2
3
TIMER
OFF/ON
POW
ERFUL
ECONOMY
SLEEP
ON
SET
FAN SPEED
MODE
■ Indoor Unit
HOW TO OPERATE
■ Setting Temperature
• Press 3 to increase or decrease the temperature.
• The temperature can be set between 60°F ~ 86°F.
• Recommended temperature:
2
1
6
3
5
4
1 Connect the power supply cord to an independent
power supply
2 Open the front panel
3 Remove the air filters
4 Fit the air purifying filters in place
5 Insert the air filters
6 Close the front panel
■ Remote Control
– To set the current time
2
3
5
1
6
4
■ To start the operation
• Press 1.
• POWER indicator (green) on the indoor unit will light
1 Press 1.
2 Then press 2 to increase or decrease the time.
3 Press 1 again.
5
Set time at display will light up.
• Once the Automatic Operation is selected, the
indoor temperature sensor operates automatically
to select the desired operation mode with Cooling
or Soft Dry.
• After the operation mode has been selected, the
mode does not change.
■ Setting the Fan Speed
• Press 4 to select:-
FAN– Low Fan Speed
FAN– Medium Fan Speed
FAN– High Fan Speed
AUTO
FAN–Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
■ Setting the Horizontal Airflow Direction
• Press 6 to select:-
Horizontal
Airflow
Direction
Remote
Control
Indoor
Unit
● Operation Details
COOL – Cooling Operation
• To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
• Sense indoor temperature to select the optimum
mode.
• Temperature is not displayed on the remote control
during AUTO operation.
ENGLISH
■ Setting the Vertical Airflow Direction
• Press 5 to select:-
AUTO
AUTO
• Swing up/down automatically.
AUTO
AUTO
• Swing left/right automatically.
● Notes
• If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
• If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
DRY – Soft Dry Operation
• A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
• During Soft Dry operation, the indoor fan operates at
Low fan speed.
FAN – Air Circulation Operation
• When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
4°F below the set temperature.
(It is useful when using a heater).
6
Loading...
+ 15 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.