PROFESSIONAL JOG PAD
ROM KIT
AY-PB2003
Before attempting to connect or operate this product,
please read these instructions carefully.

This Class A digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la classe A est conforme à la
norme NMB-003 du Canada.
WARNING:
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may
be of sufficient magnitude to constitute a
risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating
and maintenance (servicing) instructions
in the literature accompanying the appliance.
The information marking of this product may be found on the
bottom of the unit.
The serial number of this product may be found on the bottom of the unit.
You should note the serial number of this unit in the space
provided and retain this book as a permanent record of your
purchase to aid identification in the event of theft.
Model No.
Serial No.
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
SA 1965
SA 1966
For CANADA
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
For U.S.A

PREFACE
The ROM in this package is for exclusive use with the
professional jog pad in the non-linear workstation WJMX1000 and WJ-MX1200 series. Be sure to use the
application software version 4.2 or later version.
Before replacing the ROM, install the software of
Version 4.2 or higher.
Connect the professional jog pad after replacing the
ROM.
If you do not have the professional jog pad AY-JP2000,
it is not necessary to replace the ROM.
Important
• Before replacing the ROM, be sure to press the
power switch off and pull out the power plug
from the electrical outlet.
• Before handling the board, touch a metal part of
it with your hand to discharge static from your
body. Touching the board while you still have
static in your body may cause the board to fail.
It would be safer to wear an antistatic wrist
strap.
• When it is necessary to temporarily place the
board, put it on an antistatic mat or the like. Do
not let any metal part of the board contact the
metal parts of other boards.
-3-

U
C
1
A
O
1
4
A
Lock Lever
Pull the lever to
release the board.
Press the lever to
lock the board.
Hook Button
e Loosen the screws and remove the
protection cover. (Be careful not to lose
the screws.)
q Switch power off
and pull out the
power cable plug.
w Push the hook button
down and remove the
front panel.
r Remove the input board
(the second one from the bottom).
Protection
Board
Front Panel
BOARD REMOVAL
q Quit system operation, switch power off, and pull
out the power plug from the electrical outlet. Be
sure to read the Installation Manual for the Main Kit
(WJ-MX1000 and WJ-MX1200 series) for how to
quit system operation.
w Push down the hook button on the right and left
sides of the main unit and remove the front panel.
e Loosen the screws and remove the protective
cover. Be careful not to loose the screws.
r Remove the second board from the bottom (input
board).
Note: Some models have a fan mounted on the protec-
tion board. Exercise good care about the wires
when removing the board.

-5-
Fig. 2Fig. 1
There is the danger of damaging the ROM if the
remover is not fully inserted.
[How to Use Remover]
Insert the hooks at the ends of the remover into the two
diagonally located holes in the ROM socket as shown in
Figure 1, and grip the remover as shown in Figure 2.
* Never forcibly pull the remover upwards.
The ROM can be removed by lifting it out of the socket.
Mark the removed ROM with red ink, for example, so it
will not be mistaken for a new ROM.
Replacing the ROM
t With the shielding plate down, place the removed
input board on an antistatic mat or the like, and
remove the ROM from the input board.
Caution: Insert the hooks at the ends of the remover all
the way in, then pull out the ROM.
Hook

y Place a new ROM in the socket. Check the direc-
tion of the mark for pin 1 so that the ROM will be
inserted in the correct direction, keep the ROM
level, apply an even force on the ROM taking care
not to bend the pins, and insert it fully till it clicks.
-6-
Mark for pin 1
BOARD MOUNTING
u Pull the board tabs toward yourself and insert the
removed board into its original position. Push the
tabs to fasten the board. Be sure to push the tabs
all the way.
i Fasten the protective cover with the screws.
o Push down the hook buttons on the right and left
sides of the main unit.
!0 Hold the front panel where it should be, then mount
it back. The hook buttons come up to fasten the
front panel.
!1 Make sure that the front panel is securely fastened.
!2 Insert the power plug back into the electrical outlet,
and switch power on. Check that the system is
started.
Be sure to read the Installation Manual for the Main
Kit (WJ-MX1000 and WJ-MX1200 series) for how to
start the system.

Accessories
Remover ...................................................................... 1
Warranty ...................................................................... 1
-7-

NM0499-1069 7J1A339B Printed in Japan
PANASONIC BROADCAST & DIGITAL SYSTEMS COMPANY
DIVISION OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA
Executive Office: 3330 Cahuenga Blvd W., Los Angeles, CA 90068
(323) 436-3500
EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621
Mid-Atlantic: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621
Southeast Region: 1225 Northbrook Parkway, Ste 1-160 Suwanee, GA 30024
(770) 338-6845
Central Region: 1707 N Randall Road E1-C-1, Elgin, IL 60123 (847) 468-5200
WESTERN ZONE: 3330 Cahuenga Blvd W., Los Angeles, CA 90068 (323) 436-3500
Dallas Region: 6226 Abington Way, Houston, TX 77008 (713) 802-2726
Government Marketing Department: 52 West Gude Drive, Rockville, MD 20850 (301) 738-3840
PANASONIC CANADA INC.
5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 (905) 238-2115
PANASONIC SALES COMPANY
DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO, INC.
San Gabriel Industrial Park, 65th Infantry Ave., KM9.5 Carolina, Puerto Rico 00630 (809) 750-4300