Oregon RMR500ESA, RMR500ESU, RMR500ES USER MANUAL

+ECO Clima Control
Model: RMR500ES / RMR500ESU /
RMR500ESA
USER MANUAL
CONTENTS
Earth Friendly....................................................................2
Front View.......................................................................2
LCD Display....................................................................2
Back View........................................................................3
Outdoor Sensor - THGN500.........................................3
Remote Sensor - THGR122N.......................................4
Getting Started..................................................................4
Solar Panel......................................................................4
Backup Power.................................................................5
Name Tags......................................................................5
Remote Sensors................................................................5
Clock and Calendar..........................................................6
Clock Reception..............................................................6
Manually Set Clock.........................................................7
Temperature and Humidity..............................................7
Mold Alert........................................................................7
Weather Forecast..............................................................8
Backlight............................................................................8
Reset..................................................................................8
Specications...................................................................8
Precautions.......................................................................8
About Oregon Scientic..................................................9
EU-Declaration of Conformity.........................................9
FCC Statement.................................................................10
Declaration of Conformity..............................................10
1
EN
EN
2
1
2
1 2
3 4
5
6
7 8
9
10
11
12
13
EARTH FRIENDLY
Oregon Scientic™ proudly presents +ECO Clima Control,
an environmental-friendly weather-monitoring clock that converts solar energy into its source of power via a solar
panel. Convenient and easy to use, you only need to lift the
solar panel and face it directly towards the sun for a few hours in order to receive the amount of energy necessary to power the device.
OVERVIEW
FRONT VIEW (FIG 1)
1. LCD Display
2. LED indicator
LCD DISPLAY (FIG 2)
1. AC/DC power adaptor icon
2. Weather forecast icon
3. Outdoor sensor reception icon
4. Outdoor temperature display for THGN500*
5. Temperature/humidity display for main unit environment
6. Time zone
7. Clock signal reception indicator
8. Clock display (or temperature/humidity display for optional sensor)
9. Sunlight icon
10. Calendar display (or temperature/humidity display for optional sensor)
11. Temperature/humidity display for THGR122N remote
1
6
3
7
4
5
8
2
1
2
3
4
sensor
12. Outdoor humidity display for THGN500*
13. Mold alert
* This product is designed to display the temperature and
humidity reading of THGN500 in the outdoor temperature/ humidity area only.
4. : Decrease values in setting mode; deactivate clock
signal reception
5. : Activate backlight
6. RESET: Reset unit to default settings
7. °C / °F: Select temperature unit
8. Power adaptor jack
EN
BACK VIEW (FIG 3)
1. Solar panel
2. : Toggle between clock, calendar and temperature/ humidity displays; enter setting mode
3. : Increase values in setting mode; activate clock signal reception
OUTDOOR SENSOR - THGN500 (FIG 4)
1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole
3
EN
4
2
1
3
4 5
6
600mAH rechargeable battery
REMOTE SENSOR - THGR122N (FIG 5)
1. LCD display
2. LED status indicator
3. Wall mount hole
4. RESET hole
5. CHANNEL switch
6. Battery compartment
GETTING STARTED
SOLAR PANEL
This product uses a 600mAH rechargeable battery which
should be charged via the solar panel. For the battery’s rst charge, it is strongly advised to charge it for at least 12 hours
by lifting and positioning the solar panel in such a way that it faces sunlight directly.
IMPORTANT The solar panel should be lifted and
positioned at no more than 90°.
When the rechargeable battery is nearly at, the LED indicator on the main unit and will ash. Expose the solar panel directly to sunlight for approximately 5 to 6 hours to charge the battery. Normally, the battery life will last for 2
months.
TIPS
• For best results when charging the battery, avoid placing the product behind glass windows, but expose
the solar panel directly to sunlight.
• Do not scratch the solar panel’s surface or wipe it with strong detergent.
• Do not expose the solar panel to rain, snow or
moisture.
• The duration of the rechargeable battery’s charging or
2 x CR2032
operating time is determined by either the intensity of sunlight or the positioning of the solar panel towards the sun.
BACKUP POWER
CR2032 batteries
In the case when the rechargeable battery is at or nearly at, the 2 pieces of CR2032 batteries can act as backup
power supply for the main unit.
1. Remove the battery compartment.
2. Insert the batteries, matching the polarities.
3. Press RESET after each battery change.
LOCATION MEAN ING Outdoo r temperat ure/ humidit y area (T HGN50 0) Main unit e nvironme nt area CR2032 batteries low Remote sensor area (THG R122N) Clock an d calenda r area (or optiona l sensor s area)
Outdoo r sensor battery l ow
Remote sensor batt eries low Optional sensor s batter ies low
Power adaptor (not included)
The power adaptor can also be used for charging the
rechargeable battery. When connected to the main unit,
will be displayed.
NAME TAGS
Name tags can be inserted in the main unit as in Fig. 1.
There are 10 name tags provided in this package, with 7 blank tags and 3 tags printed as “MAIN UNIT”, “TIME” and
“CALENDAR”. You can write in the blank tags the name of the location where THGR122N and other optional sensors are installed.
NOTE If optional sensors are installed, “CALENDAR” and
“TIME” tags will be replaced.
REMOTE SENSORS
This product can work with up to 4 sensors at any one time to capture temperature and relative humidity readings in various locations.
5
EN
EN
6
2 remote sensors (THGN500 and THGR122N) are provided
in this package, while 2 more optional wireless remote
sensors can be purchased separately.
Optional wireless remote sensors such as those listed below can be purchased separately:
- THGR122N / THGN122N
- THGN132N
- THGR228N / THGN228N
- THGR238N / THGN238N
To set up the remote sensor:
1. Open the battery compartment and insert batteries,
matching the polarity.
2. Select a channel then press RESET.
3. Close the battery door.
4. Place the remote sensor within 30 m (98 ft) from the main unit.
NOTE Use alkaline batteries for longer usage and consumer
grade lithium batteries in temperatures below freezing.
To search for a sensor:
Press and hold + at the same time.
The remote sensor reception icon will show the following status:
ICON DESCRI PTION
TIP The transmission range may vary depending on many
factors. You may need to experiment with various locations
to get the best results.
Main unit is searchin g for sensor(s). A channel has been found. The senso r cannot be found.
CLOCK AND CALENDAR
NOTE If optional sensors are installed:
• clock and calendar display will be replaced by temperature/humidity readings.
• press to toggle between clock and temperature/
humidity display, or calendar and temperature/humidity
display.
CLOCK RECEPTION
This product is designed to synchronize its clock automatically with a clock signal.
RMR500ES:
EU: DCF-77 signal: within 1 500 km (932 miles) of Frankfurt,
Germany.
RMR500ESU:
UK: MSF-60 signal: within 1 500 km (932 miles) of Anthorn,
England.
RMR500ESA:
WWVB-60 signal: within 3200 km (2000 miles) of Fort
Collins, Colorado.
To enable / disable clock signal reception:
Press and hold to enable or to disable clock signal reception.
NOTE Reception takes 2-10 minutes. If the signal is weak,
it can take up to 24 hours to get a valid signal. If signal
reception is unsuccessful, place your unit next to a window,
press and hold to force another signal search.
Clock signal reception indicator:
STRONG S IGNAL WEAK / N O SIGNA L
MANUALLY SET CLOCK
To set the clock manually, disable the clock signal reception rst.
1. Press and hold .
2. Press or to change the settings. The settings
order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (month – day / day – month), month and
day.
3. Press to conrm.
RMR500ES / RMR500ESU: Time zone sets the clock +/-
23 hours from the received clock signal time. If you have
deactivated the clock signal reception, do not set a value
for time zone.
RMR500ESA: Select the time zone: (0) Pacic, (+1) Mountain, (+2) Central or (+3) Eastern.
TEMPERATURE AND HUMIDITY
To toggle temperature unit:
Press °C / °F.
NOTE “HH.H” or “LL.L” will be displayed when the received
temperature is out of the specied temperature range.
MOLD ALERT
This product features moisture alert function for the
prevention of mold. If the humidity is over 60%, the mold
alert icon will ash, and will stop ashing if the humidity is less than 60%.
7
EN
EN
8
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather
within a 30-50 km (19-31 mile) radius with 75% accuracy.
Sunny
Parti ally Cloud y
Cloudy
Rainy
Snowy
BACKLIGHT
Press to activate LED backlight for 5 seconds.to activate LED backlight for 5 seconds.
RESET
Press RESET to return to the default settings.
SPECIFICATIONS
TYPE D ESCRIP TION MAIN U NIT
L x W x H
Weight 400 g (14.11 oz) without batter y Signal frequency 433 MHz
130 x 80 x 130 mm (5.1 x 3.15 x 5.1 in)
Temperature r ange -5°C to 50°C (23°F to 122 °F) Humidit y range 25% - 95%
Power
REMOT E UNIT (T HGN50 0)
L x W x H
Weight 63 g (2.2 2 oz) without b atter yg (2.22 oz) without bat tery (2.22 oz) without bat tery Signal frequency 433 MHz Number of c hannel 1 Transmission range 30 m (100 ft) uno bstruc ted Temperature r ange -20°C to 6 0°C (-4°F to 140°F) Humidit y range 25% - 95% Power 1 x UM-3 ( AA) 1.5  bat teryA) 1.5 V batter y) 1.5 V batter y
REMOT E UNIT (T HGR122N)
L x W x H
Weight 63 g (2.2 2 oz) without b atter yg (2.22 oz) without bat tery (2.22 oz) without bat tery Signal frequency 433 MHz Number of c hannel 3 Transmission range 30 m (100 ft) uno bstruc ted Temperature r ange -20°C to 6 0°C (-4°F to 140°F) Humidit y range 25% - 95% Power 2 x UM- 4 (AA A) 1.5  batteryA) 1.5 V batter y) 1.5 V batter y
600mAH rechargeable battery; 6V AC/DC adaptor (not included);
2 x CR2032 batteries (for backup)
50 x 22 x 96 m m mmmm (1.9 x 0.9 x 3.8 in)
92 x 60 x 20 mm mmmm (3.6 x 2.4 x 0.79 in)
PRECAUTIONS
• Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
• Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
• Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit’s internal components. This invalidates the warranty.
• Only use fresh batteries. Do not mix new and old
batteries.
• Images shown in this manual may differ from the actual display.
• When disposing of this product, ensure it is collected
separately for special treatment and not as normal household waste.
• Placement of this product on certain types of wood
may result in damage to its nish for which Oregon Scientic will not be responsible. Consult the furniture
manufacturer's care instructions for information.
• The contents of this manual may not be reproduced without the permission of the manufacturer.
• Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
• Please note that some units are equipped with a battery safety strip. Remove the strip from the battery
compartment before rst use.
NOTE The technical specications for this product and the
contents of the user manual are subject to change without notice.
NOTE Features and accessories will not be available in all
countries.For more information, please contact your local
retailer.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientic.com) to learn more about Oregon Scientic products.
If you’re in the US and would like to contact our Customer
Care department directly, please visit:
www2.oregonscientic.com/service/support.asp
For international inquiries, please visit:
www2.oregonscientic.com/about/international.asp
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientic, declares that this +ECO Clima
Control (model: RMR500ES / RMR500ESU / RMR500ESA) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on
request via our Oregon Scientic Customer Service.
COUNTRIES RTTE APPROVED COMPLIED
and Norway N
All EU countries, Switzerland CH
9
EN
EN
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
WARNING Changes or modications not expressly
approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio / T technician for
help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please visit our website at www2.oregonscientic.com/service for all enquiries.
We
Name: Oregon Scientic, Inc.
Address: 19861 SW 95th Ave.,Tualatin,
Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: RMR500ES / RMR500ESU / RMR500ESA
Product Name: +ECO Clima Control
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St., Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept
any interference received, including interference that may
cause undesired operation.
10
Loading...