• 75ml is designed for Sleep
/ Aromatherapy Mode. Use
with distilled water.
• 45ml is designed for Face and Hair
Mode. Use with Herbal Solution plus
either Intensive Restoring Serum or
Revitalizing Hair Treatment Serum.
2 full pumps of
Intensive Restoring
Serum
2 full pumps of
Revitalizing Hair
Treatment Serum
---
5 mins / session
5 mins / session
1 min mist ON, 7mins mist OFF,
total 8 hours usage
Light Mode
Light Mode
9
Intensive Mode
Intensive Mode
Continuous mist
Continuous mist
Duty Cycle mist
Using the Device
Getting accustomed to the device
Those new to the device should start with skin treatments twice a day, or hair treatment 2-3 times a week.
If you encounter any skin problems after use, stop using the device and consult your doctor�
Check the followings before using the product:
The air inlet and
The water tank
cover must be
closed.
The drain saucer
is empty and
properly installed.
The drain switch
is at the “CLOSE”
position.
mist outlet are
not blocked or
covered.
The device is on
a sturdy, level and
dry surface.
Getting Started
1.
Make sure the device is turned off and unplugged
from the mains outlet before filling with water
solution or distilled water.
Press the button on the water tank
compartment and slide to open the cover.
10
EN
2.
3.
4.
Herbal
Solution
X2
Pull out the water container.
Turn the container cap anti-clockwise
to open the container.
Fill the container with Herbal Solution up to the
45ml mark and mix with 2 full pumps of either
Intensive Restoring Serum for Face Mode or
Revitalizing Hair Treatment Serum for Hair Mode.
Do not add other substances such as aroma oil or lotion
to the container�
Use herbal solutions and serums provided by Oregon
Scientific
OR
5.
6.
Fill the container with distilled water up to
75ml mark for Sleep / Aromatherapy Mode.
Do not add ground water, mineral water, spring water,
ionised water or saline to the container, as it may
damage the device�
Turn the container cap clockwise
to close the container.
Do not press the valve on the cap when
the container is upside down. Otherwise,
the solution inside will leak.
Insert the container back to the compartment.
The solution will drain to the water tank. Close the
cover before use.
11
Operation
A. Setup
1.
2.
3.
B. Skin Treatment
1.
2.
Place the device on a sturdy, level and dry surface.
Connect the power adapter to the device. Plug the
power adapter to a main outlet.
Press to turn on the device.
Press the key to start the skin treatment.
A LED above the key will light up.
Each treatment lasts for 5 minutes.
The appropriate distance between the mist
outlet and the face should be from 20-25cm.
3.
4.
5.
Press the key again to increase the mist
volume. Two LEDs above the key will light up.
To direct the mist to a specific area, attach the
extension hose and the nozzle during use. Hold the
nozzle approximately 15-20cm from the target area.
The extension hose has limited length. Don’t pull the
extension hose if the treatment area is too far away.
Bring the device closer if necessary.
Press the key during operation to switch the
device to standby mode. Otherwise the device will
switch to standby mode after 5 mins the session is
finished.
Close the eyes when the mist is directly sprayed on you face
12
C. Hair Treatment
EN
1.
2.
3.
4.
5.
Attach the comb, the nozzle and the
extension hose to the mist outlet.
Press the key to start the hair treatment.
One LED above the key will light up.
Each treatment lasts for 5 minutes.
Press the key again to increase the mist
volume. Two LEDs above the key will light up.
Comb your hair and start the hair treatment
Press the key during operation to switch
the device to standby mode. Otherwise
the device will switch to standby mode
after 5 mins the session is finished.
Hair treatment of 5 mins course is recommended for short or
middle length hair. One more course is needed for long and
more intensive treatment.
D. Sleep Mode
1.
2.
Attach the nozzle to the device. Rotate
the nozzle to your desired direction.
Place the device on a level surface near the bed
so the mist can reach your target area. Adjust
the nozzle angle to what is comfortable for you
that is within 30cm from the target area.
Do not place the device on the bed as the device is
susceptible to being knocked over�
13
D. Sleep Mode - Continued
3.
4.
E. Aromatherapy
Press the key to start the sleep mode. The
device will emit mist for 1 minute and then pause
for 7 minutes. This cycle will last until the water runs
out. A full tank of water can last around 8 hours.
Press the key to switch the
device to standby mode.
1.
2.
3.
4.
5.
6.
Unscrew to open the aroma head.
Take out the sponge and place a
few drops of aroma oil on it.
Put the sponge back.
Close the aroma diffuser head.
Attach the aroma head to the mist outlet.
Press the key to start the aromatherapy.
Aromatherapy mode is for relaxation� It is not intended to be
used for skin treatment� Do not spray the aromatic mist onto
your face�
14
Cleaning and Maintenance
Turn off the device and unplug it from
the power supply before cleaning�
A. Draining the distilled water / herbal solution / serum
Slide the drain switch to the “Drain” position.
The blue LED at the base will start flashing
1.
2.
3.
and the solution inside the water tank
will be released to the drain saucer.
Place the device in a level position, then
hold and rotate the main unit to the left
to separate it from the saucer.
Lift up the main unit, remove the drain
saucer and empty the water.
EN
Put the saucer back, Place the unit on the saucer
4.
5.
•Ensure the drain saucer is empty before draining the water from the device� Otherwise, water will
leak out from the saucer and may damage the device�
•Never leave water, herbal solution or serum in the saucer� Empty the saucer after each draining�
•Do not reuse the distilled water, herbal solution or serum from previous treatments�
and rotate it until the dot ( ) on the main
unit aligns with the dot ( ) on the saucer.
Lock the device by sliding the drain
switch to the “Close” position.
15
B. Cleaning the water tank
1.
2.
3.
4.
5.
C. To pick up the device
Open the water tank compartment.
If herbal solution or serum is used, fill the
container with distilled water, insert it into
the container compartment and drain.
Turn the water tank cover anticlockwise and take it out.
Use the cleaning brush to clean the diffusing
plate and the inner surface of the water tank.
Don’t apply excessive force when cleaning the
diffusing plate�
Fill the container with distilled water,
insert it into the container compartment
and drain again for a through cleaning.
Drain the water tank and
empty the drain saucer
before picking up or
moving the device.
D. Cleaning the housingE. Storage
• Do not use abrasive powders or
solvents, such as benzene or thinner to
clean the device.
• Use a dry cloth to clean its surface.
1. Press the water tank
compartment button and
slide down the cover.
Before storing the device, drain all water or
Herbal Solution inside. Wait until the water
tank is dry and use the mist outlet stopper
to seal the mist outlet.
Don’t leave the excessive solution inside the
water tank� Drain it after every time use�
16
2. Use the handle
underneath the button
to pick up the device.
Technical Specification
EN
Power
Power consumption36W
Operating temperature5 ºC to +40 ºC
Storage temperature-20 ºC to +60 ºC
Size212mm x 210mm x 234mm
Weight1.3kg
AC 100~240V 50~60 Hz
DC 24V, 1500mA
About Oregon Scientific
Please visit our website at www.oregonscientific.com to learn
more about Oregon Scientific products.
If you would like to contact our customer care team, please email
to info@oregonscientific.com
EU - Declaration of Conformity
Hereby, Oregon Scientific, declares that this NanoActiv Skin
Restoring System FS838 is in compliance with EMC directive
2004 / 108 / EC and Low Voltage Equipment directive 2006 / 95
/ EEC. A copy of the signed and dated Declaration of Conformity
is available on request via our Oregon Scientific Customer Service.
Correct Disposal of this product:
This marking indicates that this product
should not be disposed with other household
wastes though out the EU. To prevent possible
harm to the environment or human health
from uncontrolled wasted disposal, recycle it
responsibly to promote the sustainable reuse of
material resources. To return your used systems
or contact the retailer where the systems or
contact the retailer where the product was
purchased. They can take this product for
environmental safe recycling.
17
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.