Oregon Scientific EW93 User manual

C8313A(DCF MSF) Size: 148 x 105(mm)
Weather Station
with Radio-Controlled Alarm Clock and Ice Alert
Model: EW93
USER MANUAL
EN
Radio-Controlled Alarm Clock and Ice Alert
Weather Station with
Model: EW93
USER MANUAL
Brief Introduction ............................................2
Overview .........................................................2
Receiver ....................................................2
LCD Display ...............................................4
Sensor .......................................................4
Reception of Sensor Signal ...........................4
Operating the Main Unit .................................4
Operating the Sensor ..................................5
Reception of Radio Controlled Time Signal ....6
Signal Reception Indicator ............................6
Time and Calendar Manual Setting ...................6
Alarm Time Setting .........................................7
Using Alarm Function ....................................7
To Silence the Alarm .......................................8
Reading Indoor & Outdoor Temperature Records ...8 Viewing the Min. & Max. Temperature Records ...8
Weather Forecast Indicator ...........................8
Using Ice Alert Function ................................9
Battery Replacement .....................................9
Placement of Main Unit and Sensor .................9
Precautions ..............................................10
Specifications ..........................................11
About Oregon Scientific ........................11
Eu-Declaration of Conformity ............12
FCC Statement .............................................12
Declaration of Conformity ............................12
1
EN
15
1
BRIEF INTRODUCTION
Thank you for your purchase of this Weather Station with Radio-Controlled Alarm Clock and Ice Alert. Please read these instructions carefully and keep the manual well for future reference.
4
2
3
5 6
7 8
9 10
11 12 13
14
The receiver unit has a clear and easy-to-read display that shows the indoor temperature, time, the maximum & minimum temperature records in the past 24 hours as well as the outdoor temperature measured and transmitted from the remote sensors. It is able to receive and display readings from up to 3 remote sensors.
The 433 MHz technology means no wire installation is required and you can place the sensors anywhere you like within 30m (100ft) from the main (indoor) unit.
This product is designed to synchronize its date and time automatically once it is within range of the signal from the atomic clock in Germany/England.
OVERVIEW
RECEIVER
1.SNOOZE/LIGHT key:
In normal time mode, press it once to turn on the backlight for 5 seconds.
Press it to silence the current alarm when it is going and enter the snooze mode for 8 minutes.
2.LCD display:
• Displays outdoor & indoor temperature, time and date.
3.Ice Alert indicator light:
Flashes when the outdoor temperature is between -2.0°C (28 °F) and 3.0°C (37 °F).
4.+/CHANNEL key:
Press it once to switch among Channel 1, 2 and 3.
2
EN
Press and hold it for 2 seconds to view the channels automatically. Press it again to exit the automatic display mode.
In time setting mode, press it to increase the setting values.
5.SET CLOCK key:
In normal time mode, press it once to enter the normal time setting mode.
In normal time setting mode, press it to step the setting items. Press and hold it to exit the setting mode in any step.
6.-/MIN.MAX. key:
Press it to show the minimum and maximum temperature records in the past 24 hours.
Press and hold it for 3 seconds to delete the minimum and maximum temperature records.
In time setting mode, press it to decrease the setting values.
7.SENSOR key:
Press it once to search a sensor.
During the reception period, press and hold it for 3 seconds to stop the reception.
8.°C/°F slide switch:
Slide it to switch between Celsius and Fahrenheit.
9.ALARM ON/OFF key:
Press it once to turn on the backlight and display the alarm time for 5 seconds.
Press it again to turn on/off the alarm.
10.SET ALARM key:
Press it once to turn on the backlight for 5 seconds, and at the same time to enter the alarm time setting mode.
In alarm time setting mode, press it to step the setting items.
11.RESET key:
Press it to return all values to default values.
In case of malfunction, the unit may be required to reset.
12.RCC key:
In normal time mode, press it once to receive the RC signal for reception testing.
During the reception period, press and hold it for 8 seconds to stop the reception.
13.UK/EU slide switch:
Slide it to select the country version between EU (Germany) and UK (England).
14.BATTERY COMPARTMENT:
3EN4
Accommodates 2 AA size batteries.
6
7
9108
1.LED indicator:
Flashes when the remote unit transmits a
15.BATTERY DOOR
LCD DISPLAY
reading.
2.Wall-mounting holder:
Supports the sensor on the wall.
1. Weather forecast icon
2. Sensor signal
3. Channel
4. Low battery indicator
5. Min. & Max. temperature
6. Time
7. Signal reception indicator
8. °C & °F
9. Outdoor temperature
10. Indoor temperature
SENSOR
1
2
1 2 3
4 5
6
3.RESET key:
Press it to restart the sensor and return all values to default values.
4.CHANNEL slide switch:
Assign the sensor to channel 1, 2 or 3.
5.BATTERY COMPARTMENT:
Accommodates 2 AAA size batteries.
6.BATTERY DOOR
RECEPTION OF SENSOR SIGNAL OPERATING THE MAIN UNIT
3
4 5
1. Remove the battery door and slide “UK/EU” switch to select the desired country version.
2. Insert 2 new AA size batteries as per the polarity information marked on the battery compartment.
3. Press “RESET” key to restart the clock.