DTA-9.4
Improvement of the sensitivity of DC detection circuit
Symptom:
When an excessive signal is inputted into amplifier, DC detection circuit operates and results No sound.
Cause:
The DC current detection circuit is too sensitive.
Procedure for service:
In NAAF-7797 R593, chip resistor is changed from 10K to 3.3K
DAT-9.4 has seven units of NAAF-7797 and do this change for all units.
Circuit No. Before change After change Description Remarks
Part No. Description Part No.
R593 435031034R1 RN72K1J-103J 435033324R1 RN72K1J-332J
Refer to the attached file---Page 2
Application: ...All seven power amplifier modules per unit.
Marking: Mark "A" after the serial number.