Narrow View34 to 49 mm (variable)5 x 4.6 mm to 9 x 8.3 mm (variable)ZFV-SR10
Wide View38 to 194 mm (variable)10 x 9.2 mm to 50 x 46 mm (variable)ZFV-SR50
AppearanceTypeSetting distanceSensing areaModel
Narrow View34 to 49 mm (variable)5 x 4.6 mm to 9 x 8.3 mm (variable)ZFV-SC10
Standard View31 to 187 mm (variable)10 x 9.2 mm to 50 x 46 mm (variable)ZFV-SC50
Wide View66 to 141 mm (variable)50 x 46 mm to 90 x 83 mm (variable)ZFV-SC90
Ultra-wide View114 to 226 mm (variable)90 x 83 mm to 150 x 138 mm (variable)ZFV-SC150
AppearanceTypePower supplyOutput
type
Model
Single
Function
24 VDCNPNZFV-A10
PNPZFV-A15
StandardNPNZFV-A20
PNPZFV-A25
AppearancePower supplyOutput typeModel
24 VDC
NPNZFV-CA40
PNPZFV-CA45
AppearancePower supplyOutput typeModel
24 VDC
NPNZS-DSU11
PNPZS-DSU41
AppearanceModel
ZS-XCN
Cable lengthModel
3 m
ZFV-XC3B
*1
*1.
ZFV-XC3BR Robot Cable is also available.
8 mZFV-XC8B
Appearance
ModelZS-XOM1ZS-XPM2
First Unit
Additional Units
(for expansion)
ZFV Gray Scale/Colour Series8
Page 9
2SmartVisionSensors
Specifications ZFV Gray Scale Series
Sensor Heads
Amplifier Units
ItemZFV-SR10 (Narrow View)ZFV-SR50 (Wide View)
Setting distance (L)34 to 49 mm38 to 194 mm
Detection range (H × V)5 × 4.6 mm to 9 × 8.3 mm10 × 9.2 mm to 50 × 46 mm
Relation between setting distance and
detection range
Guide lightProvided (center, sensing area)
Built-in lensFocus: f15.65Focus: f13.47
Object lighting methodPulse lighting
Object light sourceEight red LEDs
Sensing element1/3-inch CCD, partial scan
ShutterElectronic shutter, shutter time: 1/1,000 to 1/4,000
Power supply voltage15 VDC (Supplied from Amplifier Unit.)
Current consumptionApprox. 200 mA
Vibration resistance (destruction)10 to 150 Hz, 0.35-mm single amplitude, 10 times each in X, Y, and Z directions for 8 min
Shock resistance (destruction)
150 m/s
2
, three times each in six directions (up/down, left/right, forward/backward)
Connection methodPrewired, Standard cable length: 2 m
Degree of protectionIEC60529, IP65
Characters (CHAR)
Teaching areaRectangular, one area
Teaching area size Pattern (PTRN), Brightness (BRGT): Any rectangular area (256 × 256 max.)
Area (AREA), Width (WID), Position (POSI), Count (CNT), Characters (CHAR): Any rectangular area (full
screen max.)
Sensing areaFull screen
Resolution468 432 (H V) max.
Bank selectionSupported for 8 banks.
Response timePattern (PTRN), Brightness (BRGT): High-speed: 4 ms, Standard: 8 ms, High-precision: 12 ms (not using
partial scan)
Area (AREA), Width (WID), Position (POSI), Count (CNT), Characters (CHAR): 128 128: 15 ms max.
Other functionsControl output switching: ON for OK or ON for NG
ON delay/OFF delay, One-shot output, “ECO” mode
Output signals(1) Control output (OUTPUT), (2) Enable output (ENABLE), (3) Error output (ERROR)
Input signals(1) Simultaneous measurement input (TRIG) or Continuous measurement input (TRIG), Switched by using
menu.
(2) Bank selection inputs (BANK1 to BANK3)
(3) Workpiece still teaching (TEACH) or Workpiece moving teaching (TEACH), Switched by using menu.
Sensor Head interfaceDigital interface
Image displayCompact TFT 1.8-inch LCD (Display dots: 557 234)
Indicators Judgement result indicator (OUTPUT) Inspection mode indicator (RUN)
Operation interface Cursor keys (up, down, left, right) Setting key (SET) Escape key (ESC)
Operating mode switching (slide switch) Menu switching (slide switch)
Teaching/Display switching key (TEACH/VIEW)
Power supply voltage20.4 to 26.4 VDC (including ripple)
Current consumption600 mA max. (with Sensor Head connected)
Degree of protectionIEC60529, IP20
49 mm
Setting distance (L)
34 mm
5 mm9 mm
Sensing
range(H)
10 mm
187 mm
31 mm
50 mm
Setting distance (L)
Sensing
range (H)
Smart Vision Sensors9
Page 10
3ZFVGrayScale/ColourSeries
Specifications ZFV Colour Series
Sensor Heads
Note:More colour heads are available. Please contact your OMRON dealer for the full range of ZFV-SC heads.
Amplifier Units
ItemZFV-SC10 (Narrow View)ZFV-SC50 (Wide View)
Setting distance (L)
34 to 49 mm (variable)31 to 187 mm (variable)
Sensing range (H × V)
5 × 4.6 mm to 9 × 8.3 mm (variable)10 × 9.2 mm to 50 × 46 mm (variable)
Relation between setting
distance and detection range
Position (POSITION), Count (COUNT), Colour inspection (HUE)
Teaching area size• Patterns (PATTERN), Brightness (BRIGHT): Any rectangular area (256 × 256 max.)
• Area (AREA), Width (WIDTH), Position (POSITION), Count (COUNT),
Colour inspection (HUE): Any rectangular area (full screen max.)
Sensing areaFull screen
Resolution468 x 432 (H x V) max.
Bank selectionSupported for 8 banks.
Image input cycle13 ms (Standard), 8 ms (FAST mode), 5 ms (MAX mode)
Other functionsControl output switching: ON for OK or ON for NG, ON delay/OFF delay, One-shot output, "ECO" mode
Connect-
ing to
ZS-DSU
Image logging triggerStores NG images or all images.
Sampling rate
ZFV measurement cycle
*1
*1.
This is the sampling rate when logging images. To log measurement data only, use the ZS-DSU settings.
Number of logged imagesLogs up to 128 images in series
Number of connected Units 15 max. (ZFV: 5 Units max.)
External bank functionAmplifier Unit setting data can be saved to the memory card as bank data.
Reading bank data enables bank switching.
Output signals(1) Control output (OUTPUT) (2) Enable output (ENABLE) (3) Error output (ERROR)
Input signals(1) Sync measurement input (TRIG)/Continuous measurement input (TRIG); switched from menu
(2) Bank selection input (BANK1-3)
(3) Object stationary teaching (TEACH)/Object motion teaching (TEACH); switched from menu
Sensor Head interfaceDigital interface
Image displayTFT 1.8-inch LCD (Display dots: 557 x 234)
Indicators• Judgment result indicator (OUTPUT, Colour: orange) • Inspection mode indicator (RUN, Colour:
• Teaching/Display switching key (TEACH/VIEW) • Function keys (A to D, 4 inputs)
Power supply voltage
20.4 to 26.4 VDC (including ripple)
Current consumption
800 mA max. (with Sensor Head connected)
Degree of protection
IEC 60529, IP20
Sensing range
V
H
49 mm
Setting distance (L)
34 mm
5 mm9 mm
Sensing
range(H)
10 mm
187 mm
31 mm
50 mm
Setting distance (L)
Sensing
range (H)
ZFV Gray Scale/Colour Series10
Page 11
4SmartVisionSensors
Dimensions
More colour heads are available. Please contact your OMRON dealer for the full range of ZFV-SC heads.
Amplifier Units
20±0.1
Two, M4
Mounting Hole Dimensions
23.30
33.6
32
4.5 4.5
4.54.5
32
Optical axis
5.6
17.900.80
67.90
8.50
18.734
30.10
33
Connector
4
6.36
30
30
(6.36)
Focus adjustment dial
34
20
33.6
12.8 dia.
Heat-resistive vinyl-insulated cable
5.8 dia, standard length: 2 m
Two, M4
Depth: 6
1/4-20UNC
Depth: 6
Mounting Bracket can be attached to any side.
Sensor Heads
ZFV-SR10
ZFV-SC10
ZFV-SR50
5.6
9.8
8.5
6.2 dia.
Heat-resistive vinyl-insulated cable
6.2 dia, standard length: 2 m
Mounting Bracket can be attached to any side.
3
5
(
6.36
)
Mounting Hole
Dimensions
86
26.5
8
35.2
35.5
20±0.1
Two, M4
30.1
34
34
26.5
(
6.36
)
39
52.5
52.5
30.3
Two, M4
Depth: 6
1/4-UNC
Depth: 6
34
38.9
20
ZFV-SC50
3.90
4.30
4.61
10.80
1013
52.50
23.2
60
90
32.90
18
24.20
11.7 dia.
52.5
9090
3.9
4.6
60
23.4
23.2
14.8
4.2
18
Heat-resistive vinyl-insulated cable
5.2 dia., standard length: 2 m
11.7 dia.
R2
R2
R2
R2
ZFV-CA4@ZFV-A@
For full specifications and additional models please refer to www.omron-industrial.com
Vision sensors - Cat.-No. Z205-E2-02A-X (ZFC Gray Scale Series) and E373-E2-01-X (ZFV Colour Series)
• Safety units/relay units • Safety door/guard lock switches
Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant
or make any representations regarding the correctness or completeness of the information described in this document.
We reserve the right to make any changes at any time without prior notice.
Loading...