Enclosed Switch
SHL
Subminiature Enclosed Switch (Measuring
48 x 17.5 x 45 mm) with High Sealing
Property
• Built-in coil spring type basic switch housed in rigid zinc diecast
alloy casting boasts long life and high precision.
• Requires nearly the same operating force as conventional basic
precision switches (2.35 to 3.92 N).
• Molded terminal model is available.
• Operation indicator model is also available.
Model Number Structure
■ Model Number Legend
Limit
Switches
Standard Models
SHL-@55-@
21
1. Actuator
D: Plunger
Q: Panel mount plunger
Q22: Panel mount roller plunger
Q21: Panel mount crossroller plunger
W: Short hinge lever
W1: Hinge lever
W2: Short hinge roller lever
W21: Hinge roller lever
W3: One-way action short hinge roller lever
W31: One-way action hinge roller lever
Ordering Information
■ List of Models
Actuator Standard model Micro voltage
Plunger
Panel mount plunger
2. Rated Current
None: Standard
01: Micro Load
Note: Refer to page 53 for Molded Terminal Models.
SHL-D55 SHL-D55-01
SHL-Q55 SHL-Q55-01
Panel mount roller plunger
Panel mount crossroller plunger
Short hinge lever
SHL-Q2255 SHL-Q2255-01
SHL-Q2155 SHL-Q2155-01
SHL-W55 SHL-W55-01
Enclosed Switch SHL F-45
Actuator Standard model Micro voltage
Hinge lever
Short hinge roller lever
SHL-W155 SHL-W155-01
SHL-W255 SHL-W255-01
Hinge roller lever
One-way action short hinge roller lever
One-way action hinge roller lever
SHL-W2155 SHL-W2155-01
SHL-W355 SHL-W355-01
SHL-W3155 SHL-W3155-01
Specifications
■ Approved Standards
Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No. 14 LR45746
TÜV Rheinland EN60947-5-1 R9451332
■ Approved Standard Ratings
UL/CSA
A300
Rated voltage Carry current Current Volt-amperes
Make Break Make Break
120 VAC 10 A 60 A 6 A 7,200 VA 720 VA
240 VAC 30 A 3 A
TÜV Rheinland Approved Ratings (EN60947-5-1)
Model Category and rating I the
SHL-@55 AC-15 2 A/125 V
DC-12 2 A/48 V
SHL-@55-01 AC-14 0.1 A/125 V
DC-12 0.1 A/48 V
SHL-@55-L AC-15 2 A/125 V 5 A
SHL-@55-01L AC-14 0.1 A/125 V 0.5 A
SHL-@55-01L2 DC-12 0.1 A/12 V 0.5 A
SHL-@55-L3 DC-12 2 A/24 V 4 A
SHL-@55-01L3 DC-12 0.1 A/24 V 0.5 A
SHL-@55-L4 DC-12 2 A/24 V 4 A
SHL-@55-01L4 DC-12 0.1 A/24 V 0.5 A
SHL-@55-L5 DC-12 2 A/48 V 4 A
SHL-@55-01L5 DC-12 0.1 A/48 V 0.5 A
Note: For details on the above models, refer to Model Number Legend under Molded Terminal Models.
5 A
4 A
0.5 A
0.5 A
F-46 Enclosed Switch SHL
■ Ratings
Rated voltage Non-inductive load Inductive load Inrush current
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO NC NO
125 VAC 10 A 1.5 A 3 A 2.5 A 15 A max.
250 VAC 10 A 1.5 A 2 A 1.5 A
480 VAC 2 A --- --- ---
8 VDC 10 A 2 A 5 A 2 A
14 VDC 10 A 2 A 5 A 2 A
30 VDC 5 A 1.5 A 1.5 A 1.5 A
125 VDC 0.4 A 0.4 A 0.05 A 0.05 A
250 VDC 0.2 A 0.2 A 0.03 A 0.03 A
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Micro Voltage/Current Load Model
Rated voltage Non-inductive load
Resistive load
NC NO
125 VAC 0.1 A
8 VDC 0.1 A
14 VDC 0.1 A
30 VDC 0.1 A
Limit
Switches
Enclosed Switch SHL F-47
■ Characteristics
Degree of protections (see note 3) IP67 (EN60947-5-1)
Durability (see note 4) Mechanical: 10,000,000 operations min.
Operating speed 0.1 mm to 0.5 m/s (hinge lever models)
Operating frequency Mechanical: 120 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max.(initial value)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
Rated insulation voltage (U
Switching overvoltage 1,000 VAC max., 300 VDC max. (EN60947-5-1)
Pollution degree
(operating environment)
Short-circuit protective device
(SCPD)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal cur-
rent (I
Protection against electric shock Class II (grounding not required with double insulation)
OFF reverse voltage 1,000 VAC max., 300 VDC max. (EN60947-5-1)
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Ambient temperature Operating: –10°C to 80°C (no icing)
Ambient humidity Operating: 95% max.
Weight (see note 5) Approx. 62 to 72 g
Note: 1. The above figures are for standard currents.
)
the
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3. The head section of the plunger type SHL-D(Q)@@ is excluded.
4. Durability values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
5. The values are for the plunger-type models.
) 150 V (EN60947-5-1)
i
Electrical: 500,000 operations min.
Electrical: 30 operations/min
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal part and
ground, and between each terminal and non-current-carrying metal part
3 (EN60947-5-1)
10 A fuse type gG (IEC269)
5 A (EN60947-5-1)
2
Destruction: 1,000 m/s
Malfunction: 300 m/s
2
min.
min.
■ Operating Characteristics
Model SHL-D55
SHL-D55-01
OF max. 9.81 N 9.81 N 9.81 N 9.81 N 3.14 N
RF min. 1.96 N 1.96 N 1.96 N 1.96 N 0.78 N
PT max. 1.5 mm 1.5 mm 1.5 mm 1.5 mm 8 mm
OT min. 2 mm 2 mm 2 mm 2 mm 3 mm
MD max. 0.5 mm 0.5 mm 0.5 mm 0.5 mm 2.5 mm
OP 34±0.8 mm 34±0.8 mm 43±0.8 mm 43±0.8 mm 21.5±1 mm
FP max. --- --- --- --- 29.5 mm
Model SHL-W155
SHL-W155-01
OF max. 2.35 N 3.92 N 2.55 N 3.92 N 2.55 N
RF min. 0.44 N 0.78 N 0.49 N 0.78 N 0.49 N
PT max. 13 mm 8 mm 13 mm 8 mm 13 mm
OT min. 5 mm 3 mm 5.5 mm 3 mm 5.5 mm
MD max. 4 mm 2.5 mm 4 mm 2.5 mm 4 mm
OP 21.5±1 mm 33±1 mm 33.5±1 mm 44.5±1 mm 44.5±1 mm
FP max. 34.5 mm 41 mm 46.5 mm 52.5 mm 57.5 mm
SHL-Q55
SHL-Q55-01
SHL-W255
SHL-W255-01
SHL-Q2255
SHL-Q2255-01
SHL-W2155
SHL-W2155-01
SHL-Q2155
SHL-Q2155-01
SHL-W355
SHL-W355-01
SHL-W55
SHL-W55-01
SHL-W3155
SHL-W3155-01
F-48 Enclosed Switch SHL