Note: When placing an order, specify the standard temperature range and supply voltage in addition to the model number.
(e.g., E5C2-R20K 0
■ Accessories (Order Separately)
Front Connecting SocketP2CF-08
Back Connecting Socket (for flush mounting)P3G-08
Front Connecting Socket with Finger ProtectionP2CF-08-E
Protective Cover (for finger protection)Y92A-48G
Indication
method
Control modeOutputModel
PRelayE5C2-R40K
°C to 200°C 100/110 VAC)
NameModel
ThermocouplePlatinum resistance
K (CA)
Chromel vs.
alumel
L (IC)
Iron vs.
constantan
E5C2-R20L-D
E5C2-R40L-D
thermometer
E5C2-R20P-DE5C2-R20G
E5C2-R40P-D---
Pt100
Thermistor
THE
Controller
Temperature
Analogue Temperature ControllerE5C2I-7
Specifications
■ Ratings
Supply voltage100/110/120 VAC (common), 200/220/240 VAC (common) (See note.)
Operating voltage range90% to 110% of rated supply voltage
Power consumptionApprox. 2 VA
InputThermocouple (with sensor burnout detection circuit), platinum resistance thermometer, or thermistor
Control modeON/OFF or P control
Setting methodAnalog setting
Indication methodNo indication
Control outputRelay output: SPDT, 3 A at 250 VAC, resistive load (switching capacity: 330 VA)
Note: Specify either 100/110/120 VAC or 200/220/240 VAC when ordering.
50/60 Hz (common)
■ Input Ranges
InputThermocouplePlatinum resistance
K (CA)
Chromel vs. alumel
Range°C0 to 200 (5),
°F32 to 392 (10),
Note: 1. Values in ( ) are the minimum unit.
2. Values in ( ) are the thermistor resistive value.
0 to 300 (10),
0 to 400 (10),
0 to 600 (20),
0 to 800 (20),
0 to 1,000 (25),
0 to 1,200 (25)
32 to 572 (20),
32 to 752 (20),
32 to 1,112 (40),
32 to 1,472 (50),
32 to 1,832 (50),
32 to 2,192 (50)
L (IC)
Iron vs. constantan
0 to 200 (5),
0 to 300 (10),
0 to 400 (10)
32 to 392 (10),
32 to 572 (20),
32 to 752 (20)
thermometer
Pt100THE
–50 to 50 (2),
–20 to 80 (2),
0 to 50 (1),
0 to 100 (2),
0 to 200 (5),
0 to 300 (10),
0 to 400 (10)
32 to 212 (5),
32 to 392 (10)
Thermistor (see note 2)
–50 to 50 (2) (6 kΩ at 0°C),
0 to 100 (2) (6 kΩ at 0°C),
50 to 150 (2) (30 kΩ at 0°C)
---
■ Characteristics
Setting accuracy±2% FS max.
HysteresisApprox. 0.5% FS (fixed)
Proportional band3% FS (fixed)
Control periodApprox. 20 s
Reset range (see note 1)5 ±1% FS min.
Insulation resistance20 MΩ min. (at 500 VDC)
Dielectric strength2,000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts
Vibration resistanceMalfunction: 10 to 55 Hz, 0.15-mm single amplitude for 10 min each in X, Y, and Z directions
Shock resistance
Life expectancyElectrical:100,000 operations min. (3 A at 110 VAC, resistive load)
Ambient temperatureOperating: –10°C to 55°C (with no icing or condensation)
Ambient humidityOperating: 45% to 85%
Degree of protectionFront panel: IEC standard IP40 (see note 2)
WeightApprox. 200 g (with flush-mounting adapter)
Note: 1. No reset function is incorporated by any E5C2 model with ON/OFF control.
2. The model number of the special watertight cover conforming to IP66, NEMA4 is Y92A-48B.
Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs each in X, Y, and Z directions
2
Malfunction: 147 m/s
Destruction: 294 m/s
Terminals: IEC standard IP00
, 3 times each in 6 directions
2
, 3 times each in 6 directions
I-8Analogue Temperature Controller E5C2
Nomenclature
Operation Indicator
IndicatorOutput
RedLitON
Not litOFF
Dimensions
Temperature setting knob
RESET adjustment shaft
No reset function is incorporated by any
E5C2 model with ON/OFF control.
Operation indicator
Note: All units are in millimeters unless otherwise indicated.
48 x 48
Dimensions with Flush-mounting Adapter (Accessory),
and Back Connecting Socket (Sold Separately)
Panel Cutout
Side-by-side Mounting
of N Controllers
Terminal Arrangement
(Bottom View)
44.8 x 44.8
Flush-mounting
adapter
Panel
Y92F-30 Flush-mounting adapter
Tightening screw
(96) (see note)
P3G-08 Back connecting socket
Note: 109 mm for US08 Back Connecting Socket
Controller
Temperature
60 min.
N23 456
+1
+1
+1
+1
L
93
141
189
0
0
0
237
+1
285
0
0
Note: 1. Recommended panel thickness is 1 to 4 mm.
2. Close side-by-side mounting is possible (in a single direction).
P3G-08 Back Connecting Socket (for Flush Mounting)
27 dia.
Protective Cover Y92A-48
The protective cover protects the front panel, particularly the setting
section, against dust, dirt, and water drip. It also prevents the set values from being altered due to accidental contact with the setting
keys.
Note: Can also be
mounted to a
DIN track.
20 max.
Note: A finger-protection model (P2CF-08-E) is also available.
Connect a thermocouple, the E52-THE@ Thermistor or platinum
resistance thermometer to the E5C2 as shown in the following illustration.
Platinum resistance
thermometer input
Thermocouple input
Thermistor input
Relay output
Power supply
100/110, 200/220,
110/120, 220/240 VAC
50/60 Hz
Output
If the load circuit is a heating control system, be sure to connect the
load to terminals 4 and 5. If the load circuit is a cooling control system, be sure to connect the load to terminals 4 and 6. If the heating
control system is connected to terminals 4 and 6 or the cooling control system is connected to terminals 4 and 5, the temperature of the
heating control system or cooling control system will be abnormal
and a serious accident may result.
If the E5C2 is in frequent operation, such as proportional operation,
add an appropriate external relay to the E5C2 by considering the
capacity of the load and the life of the relay.
Power Supply
If a single power supply is used for the E5C2 and the load, the supply
voltage of the power supply may vary greatly when the load is open
or closed if the capacity of the power supply is not large enough.
Make sure that the capacity of the power supply is large enough so
that the supply voltage range will be always from 90% to 110% of the
rated supply voltage.
The E5C2 operates at either 50 or 60 Hz.
I-10Analogue Temperature Controller E5C2
Precautions
Mounting
Track Mounting (E5C2 with P2CF-08)
When mounting two or more E5C2 models with track-mounting sockets, leave a space of approximately 20 mm on both sides of the sockets where hooks are located.
Hook
Duct
P2CF-08
Panel
20
Flush Mounting
Insert E5C2 into the square hole of the panel and insert an adapter
from the back so that there will be no space between E5C2 and the
panel. Then, secure the E5C2 with a screw.
Tightening screw
The P3G-08 can be wired in the same way as the P2CF-08.
Dismounting
If flush mounted, loosen the screw of the adapter and disengage the
hooks for dismounting.
Controller
Temperature
Temperature Setting
Do not turn the temperature setting knob of the E5C2 with excessive
force, otherwise the stopper of the knob may break.
Others
Do not remove the housing of the E5C2, otherwise the housing may
break.
To clean the surface of the E5C2, use a soft cloth wet with neutral
detergent or alcohol. Do not use any organic solvent, such as paint
thinner or benzine, strong acid or strong alkali to clean the surface of
the E5C2, otherwise the surface of the E5C2 will become damaged.
Analogue Temperature ControllerE5C2I-11
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. H081-E1-02
In the interest of product improvement, specifications are subject to change without notice.
I-12Analogue Temperature Controller E5C2