Current Output UnitE53-C4 to 20 mA, DC; Load: 600 W max. resolution: 212
Approx. 12 VA (at 100 VAC) to 15 VA (at 240 VAC) with communication function
E5AX-MA: 0 to 100 mV, 0 to 10 mV, –10 to 10 mV
Voltage input: 1 MW min.
Key protection
Input shift
Manual output (balanceless-bumpless operation switchable)
Normal and reverse output selection
Shift set
Scaling
Watchdog timer function (Detects failures in the CPU and restores the CPU.)
(Leakage current is 1.5 mA max. at 200 VAC)
2
E5AX-LA/-MA
E5AX-LA/-MA
Characteristics
Setting accuracy+0.3% FS +1 digit max.
Indication accuracy+0.3% FS +1 digit max. (Set value coincides with the indicated value, because no relative
Indication range–10% to 110% FS
Hysteresis0.0% to 100.0% FS (in units of 0.1% FS)
Proportional band0.0% to 999.9% FS (in units of 0.1% FS)
Integral time0 to 3,999 s (in units of 1 s)
Derivative time0 to 3,999 s (in units of 1 s)
Alarm output setting range–999 to 9999 (Decimal point is displayed at set position)
Alarm output hysteresis0.0% to 100.0% FS (in units of 0.1% FS)
Scaling setting range–999 to 9999 (Decimal point is displayed at set position)
Manual output setting range0% to 100% (in units of 1%)
Control periodPulse output: 1 to 99 s (in units of 1 s)
Sampling period500 ms
Output refresh periodPulse output: 500 ms
Display refresh period500 ms
Shift set–999 to 9999 (Decimal point is displayed at set position)
Input shift–999 to 9999 (Decimal point is displayed at set position)
Insulation resistance*20 MW min. (at 500 VDC)
Dielectric strength*2,000 VAC 50/60 Hz for 1 min between terminals of different polarity
Vibration resistanceMalfunction: 2 to 55 Hz, 2G 10 min each in X, Y, and Z directions
Shock resistanceMalfunction: 200 m/s2 3 times each in 6 directions
Ambient temperatureOperating: –10% to 55%C (with no icing)
Main setting, set alarm value, proportional
band, integral time, derivative time, AT
start/stop etc.
Main setting, set alarm value, proportional
band, integral time, derivative time, output
value, scaling value, process value, error
codes, etc.
Main setting, set
alarm value
Main setting, set
alarm value,
process value, error
codes, etc.
Load: 600 W max.
Resolution: Approx. 3,200
Write disabled
Process value (see note 3),
output value
Note: 1. The maximum total cable length must not exceed the following limits.
RS-422: 500 m; RS-232C: 15 m; RS-485: 500 m
$ Recommended connectors for E5AX.
RS-485, -422, Transmission outputXM4 D-sub connector (9 pin) (OMRON)
RS-232C, BCDXM4, D-sub connector (25 pin) (OMRON)
2. A maximum of 32 Digital Controllers can be connected to one host computer using serial communications (RS-422, RS-485).
3. Outputs process value within the set limits.
Nomenclature
Process Value (PV) Display
Displays not only the process value but also indicates the character for parameter being displayed on the SV display and error messages.
Auto-tuning Indicator
Flashes on and off every
second when auto-tuning is taking place.
Shift Set Indicator
Lights when shift set function is in operation.
Manual Mode Indicator
Lights when in manual
mode.
Output Indicator
Lights when the control
output is ON. Lights off
when the current output is
ON.
Level Key
Press for 2 seconds minimum to change levels to
set different groups of parameters.
Display Key
Press to shift the display
to the next parameter.
Front Cover
Down Key
Press to decrease the set value or other parameters. Successively decreases the value when held down.
Alarm 1 Indicator
Lights when the alarm 1 output is ON.
Set Value (SV) Display
Displays set value and other
parameters.
Alarm 2 Indicator
Lights when the alarm 2 output is ON.
A/M Key (Automatic/Manual)
Press for 1 second minimum to switch
between auto output mode and manual
output mode.
Up Key
Press to increase the set value or other parameters. Successively increases the value when held down.
4
E5AX-LA/-MA
Operation
NOTICE: Always turn off power to the Digital Controller before changing any switch settings.
Settings
1. Remove the internal mechanism from the housing. Lift the
internal mechanism while pressing the hook at the bottom of
the front panel.
To remove a Control Output Unit, push it up with the tip of
a flat-blade screwdriver as shown below.
E5AX-LA/-MA
Hook
Pull out the internal mechanism
while holding down the hook with
your finger.
2. Connect a Control Output Unit to the vacant socket on the
printed circuit board as shown below.
Mount the Control Output Unit
with this mark facing the direction
indicated by the arrow.
Set the output selector to PUL (Pulse) when a Relay
(SW202, OUT), SSR, or Voltage Output Unit is mounted.
Set the output selector to CUR (current) when a Current
Output Unit is mounted.
3. Four internal switches must be set on the E5AX: the input
type selector, the operating mode selector, and the alarm
mode selectors 1 and 2.
Protection switch (SW101, PROTECT)
Flat-blade screwdriver
Output Selector (SW202)
OFFON
PULCUR
Output
CurrentON
PulseOFF
The figures show the locations of these switches and the
protection switches on the internal mechanisms. The
protection switch can be used to disable key operation.
Setting
(factory-set to OFF)
Output selector
(SW202, OUT)
Alarm mode selector 2
(SW203, ALM2)
Alarm mode selector 1
(SW205, ALM1)
Operating mode selector (SW 201,
FUNCTION)
Input type selector (SW206,
INPUT)
5
Loading...
+ 10 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.