New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with
Enhanced Functions and Performance.
Improved Indication Accuracy and
Preventive Maintenance Function.
• Indication Accuracy
Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
Pt input: ±0.2% of PV (previous models: ±0.5%)
Analog input: ±0.2% FS (previous models: ±0.5%)
• A PV/SV-status display function can be set to alternate between
displaying the PV or SV and the status of the Temperature
Controller (auto/manual, RUN/STOP and alarms).
• Preventive maintenance for relays using a Control Output
ON/OFF Counter.
• Three-level display that simultaneously displays
the PV, SV, and MV.
• One-touch operation with PF Key that can be assigned to
auto/manual, RUN/STOP, or other functions.
96 × 96 mm
E5AN
48 × 96 mm
E5EN
Refer to Safety Precautions on page 18.
Main I/O Functions
Event Inputs
• None
• Two
Sensor Inputs
• Universal thermocouple/Pt inputs
(Models with temperature inputs)
• Analog current/voltage inputs
(Models with analog inputs)
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% FS
Sampling Period and control update
• 250 ms
PF Key
(Programmab
le function key)
3auxiliary outputs
Control Output 2
• Voltage output
(for driving SSR)
Long-life relay
•
output (hybrid)
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
3-line Display ✽
Simultaneously displays set items,
such as the PV, SV, and MV.
✽ A 2-line display when shipped from the factory. A
3-line display is activated if parameters are
initialized. For details on the third display level, refer
to the User’s Manual, Basic Type (Cat. No. H156).
4 digit, 11 segments Display
• Auto/manual switching
• Temperature Controller
status display
• Simple program function
• Control output ON/OFF
count alarm
• PV change rate alarm
• Models optional available
with RS-485 or RS-232C
communications
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
Basic-type Digital Temperature Controller E5AN/E5EN1
Lineup
Temperature input
E5AN/E5EN
Basic Type
Note: all models can be used for Heating, Cooling and Heating & Cooling control.
Terminal block
Analog input
Model Number Structure
Model Number Legend
Controllers
E5AN/E5EN-@3@M@@-500-N
1 23456
1. Control Output 1
R: Relay output
Q: Voltage output (for driving SSR)
C: Current output
2. Auxiliary Outputs
3: Three outputs
3. Heater Burnout/SSR Failure, Control Output 2, or External
Power Supply for ES1B
N: Available only to models produced after January 2008
(Box marked with N6).
Note: casing color is black. White/Silver available on request.
2Basic-type Digital Temperature Controller E5AN/E5EN
Ordering Information
E5AN
Controllers with Terminal Blocks
Power
Case
Size
1/4 DIN
96 × 96 × 78
(W × H × D)
Note: Heater alarm = heater burnout + SSR short detection + SSR overcurrent
Note: Add power supply voltage to model to complete ordering code (ie. E5AN-R3MT-500-N AC100-240 or E5AN-R3MTD-500-N AC/DC24)
color
Black
supply
voltage
100 to
240 VAC
24 VAC/
DC
Input type
Thermocouple
or
Resistance
thermometer
Analog
(current/voltage)
Thermocouple
or
Resistance
thermometer
Auxilia-
ry
outputs
3
3
3
Control output
1
Relay outputE5AN-R3MT-500-N
Voltage output
(for driving SSR)
Current outputE5AN-C3MT-500-N
Relay output1-phaseE5AN-R3HMT-500-N
Voltage output
for driving SSR)
Relay output3-phaseE5AN-R3HHMT-500-N
Voltage output
for driving SSR)
Relay output
Voltage output
(for driving SSR)
Current output
Relay output
Voltage output
(for driving SSR)
Current outputE5AN-C3YMT-500-N
Relay outputSensor PowerE5AN-R3PMT-500-N
Voltage output
(for driving SSR)
Relay outputE5AN-R3ML-500-N
Voltage output
(for driving SSR)
Current outputE5AN-C3ML-500-N
Relay output1-phaseE5AN-R3HML-500-N
Voltage output
(for driving SSR)
Voltage output
(for driving SSR)
Relay outputE5AN-R3MTD-500-N
Voltage output
(for driving SSR)
Current outputE5AN-C3MTD-500-N
Relay output1-phaseE5AN-R3HMTD-500-N
Voltage output
(for driving SSR)
Relay output3-phaseE5AN-R3HHMTD-500-N
Voltage output
(for driving SSR)
Heater
alarm
1-phaseE5AN-Q3HMT-500-N
3-phaseE5AN-Q3HHMT-500-N
1-phaseE5AN-Q3HML-500-N
1-phaseE5AN-Q3HMTD-500-N
3-phaseE5AN-Q3HHMTD-500-N
Functions
Power supply
for Sensor
Sensor PowerE5AN-Q3PMT-500-N
Control
output 2
Voltage
output
Voltage
output
Voltage
output
Long-life
relay
output
Long-life
relay
output
E5AN-Q3MT-500-N
E5AN-R3QMT-500-N
E5AN-Q3QMT-500-N
E5AN-C3QMT-500-N
E5AN-R3YMT-500-N
E5AN-Q3YMT-500-N
E5AN-Q3ML-500-N
E5AN-Q3YML-500-N
E5AN-Q3MTD-500-N
Model
Basic-type Digital Temperature Controller E5AN/E5EN3
E5EN
Controllers with Terminal Blocks
Power
Case
Size
1/8 DIN
48 × 96 × 78
(W × H × D)
Note: Heater alarm = heater burnout + SSR short detection + SSR overcurrent
Note: Add power supply voltage to model to complete ordering code (ie. E5EN-R3MT-500-N AC100-240 or E5EN-R3MTD-500-N AC/DC24)
color
Black
supply
voltage
100 to
240 VAC
24 VAC/
DC
Input type
Thermocouple
or
Resistance
thermometer
Analog
(current/voltage)
Thermocouple
or
Resistance
thermometer
Auxilia-
ry
outputs
3
3
3
Control output
1
Relay outputE5EN-R3MT-500-N
Voltage output
(for driving SSR)
Current outputE5EN-C3MT-500-N
Relay output1-phaseE5EN-R3HMT-500-N
Voltage output
for driving SSR)
Relay output3-phaseE5EN-R3HHMT-500-N
Voltage output
for driving SSR)
Relay output
Voltage output
(for driving SSR)
Current output
Relay output
Voltage output
(for driving SSR)
Current outputE5EN-C3YMT-500-N
Relay outputSensor PowerE5EN-R3PMT-500-N
Voltage output
(for driving SSR)
Relay outputE5EN-R3ML-500-N
Voltage output
(for driving SSR)
Current outputE5EN-C3ML-500-N
Relay output1-phaseE5EN-R3HML-500-N
Voltage output
(for driving SSR)
Voltage output
(for driving SSR)
Relay outputE5EN-R3MTD-500-N
Voltage output
(for driving SSR)
Current outputE5EN-C3MTD-500-N
Relay output1-phaseE5EN-R3HMTD-500-N
Voltage output
(for driving SSR)
Relay output3-phaseE5EN-R3HHMTD-500-N
Voltage output
(for driving SSR)
Heater
alarm
1-phaseE5EN-Q3HMT-500-N
3-phaseE5EN-Q3HHMT-500-N
1-phaseE5EN-Q3HML-500-N
1-phaseE5EN-Q3HMTD-500-N
3-phaseE5EN-Q3HHMTD-500-N
Functions
Power supply
for Sensor
Sensor PowerE5EN-Q3PMT-500-N
Control
output 2
Voltage
output
Voltage
output
Voltage
output
Long-life
relay
output
Long-life
relay
output
E5EN-Q3MT-500-N
E5EN-R3QMT-500-N
E5EN-Q3QMT-500-N
E5EN-C3QMT-500-N
E5EN-R3YMT-500-N
E5EN-Q3YMT-500-N
E5EN-Q3ML-500-N
E5EN-Q3YML-500-N
E5EN-Q3MTD-500-N
Model
4Basic-type Digital Temperature Controller E5AN/E5EN
Option Units
NameFunctionModel
Communications Unit
Event Input Unit2 event inputsE53-AKB
RS-232C communicationsE53-EN01
RS-485 communicationsE53-EN03
Accessories (Order Separately)
USB-Serial Conversion Cable
Current Transformers (CTs)
Model
E58-CIFQ1
Terminal Cover
Connectable modelsModel
E5AN
E5EN
Note: The Terminal Cover comes with the E5EN/AN-@@@-500
models.
E53-COV16
Waterproof Packing
Connectable modelsModel
E5ANY92S-P4
E5ENY92S-P5
Note: The Waterproof Packing is included with the Controller.
Hole diameterModel
5.8 dia.E54-CT1
12.0 dia.E54-CT3
CX-Thermo Support Software
Model
EST2-2C-MV4
Basic-type Digital Temperature Controller E5AN/E5EN5
Specifications
Ratings
Power supply voltage
Operating voltage range85% to 110% of rated supply voltage
Power
consumption
Sensor input
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.)
Control methodON/OFF control or 2-PID control (with auto-tuning)
Relay output
Voltage output
Control
output
Auxiliary
output
Event
input
External power supply for ES1B 12 VDC ±10%, 20 mA, short-circuit protection circuit provided
Setting methodDigital setting using front panel keys
Indication method
Multi SP
Bank switchingNot supported.
Other functions
Ambient operating temperature −10 to 55°C (with no condensation or icing), for 3-year warranty: −10 to 50°C
Ambient operating humidity25% to 85%
Storage temperature−25 to 65°C (with no condensation or icing)
✽ A 2-line display when shipped from the factory. A 3-line display is activated if parameters are initialized (factory default setting recall). For details
on the third display line, refer to the User’s Manual, Basic Type (Cat. No. H156).
(for driving SSR)
Current output4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000
Long-life relay output
Number of outputs3
Output specifica-
tions
Number of inputs2
External contact input specifications
No D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
100 to 240 VAC: 10 VA
24 VAC/VDC: 5.5 VA (24 VAC)/4 W (24 VDC)
Models with temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Voltage input: 0 to 50 mV
Models with analog inputs
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10
mA
Output voltage: 12 VDC ±15% (PNP), max. load current: 40 mA,
With short-circuit protection circuit: Max. load current of 21 mA for control output 2
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power supply voltage: 75
to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, 10 mA, leakage current: 5 mA
max. (250 VAC, 60 Hz)
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
load: 5 V, 10 mA
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
11-segment digital display and individual indicators (7-segments display emulation also possible)
Character height: E5AN: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN: PV: 11.8 mm, SV: 8.1 mm, MV:
5.8 mm
Content of 3-level display: PV/SV/MV, PV/SV/multi-SP, or soak time remain ✽
Number of digits: 4 for PV, SV, and MV
Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations, or serial
communications.
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic
operations, PV/SV status display, simple program, automatic cooling coefficient adjustment
6Basic-type Digital Temperature Controller E5AN/E5EN
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 751
PL II: According to Platinel II electromotive force charts from BASF (previously
Engelhard)
1700 1700
1800
100
2300
Infrared temperature
sensor
10 to
70°C
60 to
120
°C
120165
PL
II
115
165
Analog
input
140
260
260
to
°C
0 to
50 mV
Usable
in the
following
ranges
by
scaling:
−1999 to
9999 or
−199.9
to 999.9
to
°C
Models with Analog Inputs
Input typeCurrentVoltage
Input specification 4 to 20mA 0 to 20 mA1 to 5 V0 to 5 V0 to 10 V
Setting range
Setting number01234
Shaded settings are the default settings.
Usable in the following ranges by scaling:
−1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or −1.999 to 9.999