Omron BP742CANN Instruction Manual

FRANÇAIS
ENGLISH
INSTRUCTION MANUAL
®
5 series
Blood Pressure Monitor
Model BP742CANN
2
TABLE OF CONTENTS
Before using the monitor
INTRODUCTION..........................................................................................3
IMPORTANT SAFETY INFORMATION........................................................4
Operating Instructions
1. KNOW YOUR DEVICE ............................................................................8
1.1 Display symbols.......................................................................10
1.2 Before Taking a Measurement.................................................12
2. PREPARATION ......................................................................................13
2.1 Battery Installation ...................................................................13
2.2 Setting the Date and Time.......................................................14
3. USING THE DEVICE .............................................................................15
3.1 Applying the Arm Cuff..............................................................15
3.2 How to Sit Correctly.................................................................17
3.3 Taking a Measurement ............................................................18
3.4 Using the Memory Function.....................................................22
Care and Maintenance
4. ERROR MESSAGES AND TROUBLESHOOTING ...............................26
4.1 Error Messages .......................................................................26
4.2 Troubleshooting.......................................................................29
5. MAINTENANCE AND STORAGE..........................................................30
5.1 Maintenance ............................................................................30
5.2 Storage ....................................................................................31
5.3 Optional Medical Accessories .................................................32
6. SPECIFICATIONS..................................................................................34
7. FCC STATEMENT..................................................................................36
8. LIMITED WARRANTY............................................................................37
9. GUIDANCE AND MANUFACTURER’S DECLARATION .......................39
3
INTRODUCTION
Thank you for purchasing the OMRON® BP742CANN Blood Pressure Monitor. Your new blood pressure monitor uses the oscillometric method of blood pressure
measurement. This means the monitor detects your blood movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
Intended Use
This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population. The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with the measurement result.
Please read this instruction manual thoroughly before using the device. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR PHYSICIAN.
4
IMPORTANT SAFETY INFORMATION
Warning: Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
(General Usage)
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
This device is not intended to be a diagnostic device.
Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, pre-eclampsia, renal diseases. Note that PATIENT motion, trembling, shivering may affect the measurement reading.
Do not use the device on the injured arm or the arm under medical treatment.
Do not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion.
Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt.
Do not use the device with other medical electrical (ME) equipment simultaneously.
Do not use the device in the area the HF surgical equipment, MRI, or CT scanner exists, or in the oxygen rich environment.
The air tube or the AC adapter cable may cause accidental strangulation in infants.
Contained small parts that may cause a choking hazard if swallowed by infants.
(AC Adapter (optional) Usage)
Do not use the AC adapter if the device or the power cord is damaged. Turn off the power and unplug the power cord immediately.
Plug the AC adapter into the appropriate voltage outlet. Do not use in a multi-outlet plug.
Never plug in or unplug the power cord from the electric outlet with wet hands.
5
IMPORTANT SAFETY INFORMATION
Caution: Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
(General Usage)
Always consult your physician. Self-diagnosis of measurement results and self­treatment are dangerous.
Consult your physician before using the device for any of the following conditions:
•If you have had a mastectomy.
•People with severe blood flow problems or blood disorders as cuff inflation can
cause bruising.
Do not take measurements more than necessary. It may cause bruising due to blood flow interference.
Remove the arm cuff if it does not start deflating during the measurement.
Do not use this device on infants or persons who cannot express their intentions.
Do not use the device for any purpose other than measuring blood pressure.
Use only the approved arm cuff for this device. Use of other arm cuffs may result in incorrect measurement results.
Do not use a mobile phone or other devices that emit electromagnetic fields, near the device. This may result in incorrect operation of the device.
Do not disassemble the monitor or arm cuff. This may cause an inaccurate reading.
Do not use in a location with moisture, or a location where water may splash on the device. This may damage the device.
Do not use the device in a moving vehicle (car, airplane).
Read “If your systolic pressure is more than 210 mmHg” of this instruction manual, if your systolic pressure is known to be more than 210 mmHg. Inflating to a higher pressure than necessary may result in bruising where the arm cuff is applied.
6
IMPORTANT SAFETY INFORMATION
(AC Adapter (optional) Usage)
Fully insert the power plug into the outlet.
When disconnecting the power plug from the outlet, do not pull the power cord. Be sure to pull from the power plug safely.
When handling the power cord, take care not to do the following:
Wipe the dust off from the power plug.
Unplug monitor when not in use.
Disconnect the power plug before cleaning.
Use only an OMRON AC adapter designed for this device. Use of unsupported adapters may damage and/or may be hazardous to the device.
(Battery Usage)
Do not insert the batteries with their polarities incorrectly aligned.
Use only 4 “AA” alkaline or manganese batteries with this device. Do not use other types of batteries. Do not use new and used batteries together.
Remove the batteries if the device will not be used for three months or more.
Do not damage. Do not break it. Do not tamper with it. Do not forcibly bend or pull. Do not twist. Do not bundle during use. Do not pinch. Do not place under heavy objects.
7
IMPORTANT SAFETY INFORMATION
General Precautions
• Do not forcibly crease the arm cuff or the air tube excessively.
• Do not press the air tube while taking a measurement.
• To unplug the air plug, pull on the air plug at the connection with the monitor, not the tube itself.
• Do not drop the monitor or subject device to strong shocks or vibrations.
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Do not use the device outside the specified environment. It may cause an inaccurate reading.
• Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
8
1. KNOW YOUR DEVICE
Contents:
Monitor, arm cuff, battery set, instruction manual, quick start guide
Monitor:
Arm cuff:
A. Display B. Up/Down buttons C. USER ID selection switch D. Date/Time setting button E. START/STOP button F. Memory button
G. Battery compartment H. Air jack I. AC adapter jack
(for optional AC adapter)
G
H
I
D
A
F E
B
C
D
D
J
L
K
J. Arm cuff
(Arm circumference 9” - 17” (22 - 42 cm)) K. Air plug L. Air tube
9
1. KNOW YOUR DEVICE
Display:
M. USER ID symbol N. Systolic blood pressure O. Diastolic blood pressure P. Low battery symbol Q. Heartbeat symbol
(Flashes during measurement.)
R. Memory symbol S. Average value symbol T. Date/Time display U. Movement error symbol V. Irregular heartbeat symbol W. Blood pressure level indicator X. Deflation symbol Y. Pulse display / Memory number
N
O
P
R
M
S
T
Q
U
V
W
X
Y
10
1. KNOW YOUR DEVICE
1.1 Display symbols
Irregular Heartbeat Symbol ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the irregular heartbeat symbol will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure. If the irregular heartbeat symbol displays with your measurement results, we recommend you consult your physician. Follow the directions of your physician.
Movement Error Symbol ( )
The movement error symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2 - 3 minutes. Take another measurement, remain still during measurement.
Average Value Symbol ( )
The average value symbol is displayed when you press and hold the memory button for more than 3 seconds. The most recent average value appears on the display screen.
Irregular Heartbeat
Normal Heartbeat
Pulse
Blood pressure
Blood pressure
Short
Long
Pulse
11
1. KNOW YOUR DEVICE
Blood Pressure Level Indicator
2013 ESH/ESC Guidelines for the management of arterial hypertension
Definitions of hypertension by office and home blood pressure levels
These are from statistical values for blood pressure.
Office Home
Systolic Blood Pressure 140 mmHg 135 mmHg
Diastolic Blood Pressure 90 mmHg 85 mmHg
12
1. KNOW YOUR DEVICE
1.2 Before Taking a Measurement
To help ensure an accurate reading, follow these directions:
1. Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the arm cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at the same time each day for consistency.
13
2. PREPARATION
2.1 Battery Installation
1. Remove the battery cover.
2. Insert 4 “AA” batteries as indicated
in the battery compartment.
3. Replace the battery cover.
Notes:
• When the low battery symbol ( ) appears on the display, turn the monitor off, then replace all batteries at the same time. Long life alkaline batteries are recommended.
• The measurement values continue to be stored in memory even after the batteries are replaced.
• The supplied batteries may have a shorter life.
• Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
14
2. PREPARATION
2.2 Setting the Date and Time
Set the monitor to the correct date and time before taking a measurement for the first time.
1. Press the button.
2. Push or to change the year.
Push button to confirm the year and then the month flashes. Repeat the same steps to change the month, day, hour, and minute.
3. Press the START/STOP button to turn the monitor off.
Notes:
• If the batteries have been replaced, the date and time setting will need to be
reset.
• If the date and time are not set, “-:--” appears during or after measurement.
Minute
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Year
Month
Day
Hour
: Forward : Back
Loading...
+ 31 hidden pages