Perform replacement on a stable and at place.
l
Handle the battery carefully so that you do not drop it.
l
Not doing so could cause injury or burns due to liquid (acid) leakage.
Use a specied battery for replacement.
lNot doing so may cause a re. lProduct model:
BP100XSG: One required (Replacement battery pack for BU1002SWG) BP150XSG: Two required (Replacement battery pack for BU3002SWG)
Do not replace the battery in a place where there is ammable gas.
lSpark may occur when connecting the battery, which may cause an explosion or re.
Replacement battery pack
BP100XSG/BP150XSG Manual
This product is a replacement battery pack for uninterruptible power supply (UPS);
For BU1002SWG: Model BP100XSG For BU3002SWG: Model BP150XSG
Safety precautions
Important information for safe operation is described. Be sure to read it before installation and start of use.
: Indicates prohibition. For example,
indicates that disassembly is prohibited.
: Indicates obligation. For example, indicates that grounding is necessary.
Misuse may cause death or serious injury.
Warning
Caution
● The safety symbols and their meaning used in this manual are as follows:
* Property damage means damage to houses/household effects, livestock, and pets.
Note that events categorized as a caution required matter also may cause more
serious results under certain conditions.
Misuse may cause injury or property damage.
Caution
(for battery replacement)
Table of Contents
Safety precautions .................................................................1
Checking the contents ...........................................................3
Replacing the battery .............................................................3
2 BP100XSG/BP150XSG Instruction Manual
Pb
Caution
(for battery replacement)
If uid (dilute sulfuric acid) leaks from the battery, do not touch the uid.
lDoing so may cause blindness or burns. lIf it contacts your eyes or skin, wash it out with lots of clean water and consult your
doctor.
Do not disassemble or modify the battery.
lDoing so could cause dilute sulfuric acid leak, which could cause blindness and burns.
Do not drop the battery and do not expose it to strong impact.
lDilute sulfuric acid may leak.
Do not short the battery with metal objects.
lDoing so could cause an electric shock, re or burn. lSome electrical energy still remains inside the spent battery.
Do not put the battery into re and do not break it.
lThe battery may explode or leak dilute sulfuric acid.
Do not use a new battery and an old battery at the same time.
lDilute sulfuric acid may leak.
When replacing batteries, do not put hands in the battery compartment.
lDoing so may cause an electric shock or a short circuit. lDo not insert metal objects.
Do not insert metal objects into the battery connectors.
l Doing so may result in electric shock.
Keep plastic package bags and lms out of reach of children.
lChildren may suffocate if they place their heads into plastic bags and lms.
u
NOTE
u
Battery recycling
lThe unit uses lead acid batteries, which are a valuable recyclable resource.
Please recycle.
Storage possible period of the battery (in unused state) is about 6 months from the full charge state. (Storage temperature is 25°C or less, or every 2 months when the storage temperature is 40°C or less.
lThe battery self-discharges even when it not being used, and it goes into over-discharge
state if it is left for a long period. The backup time may become shorter or the battery may become unusable.
lDegradation progresses while the battery is being stored, and it shorten the life of the
battery. Start using it as soon as possible. lStart using the battery within 6 months after purchase. lWhen storing the battery installed on the UPS, recharge the battery for at least 8 hours
before storing and turn OFF the unit’s power switch when storing it.
lIf the storage period exceeds 6 months, connect the UPS to a commercial outlet for at least
8 hours and recharge it before the storage period exceeds 6 months. lIf storage is to be continued, recharge every 6 months when the storage temperature is
25°C or less and every 2 months when it is below 40°C.
3 BP100XSG/BP150XSG Instruction Manual
2. Remove the battery connector from the plate cover. 1 Hold the connector and pull it out.
2
90%
50%
30%
-
バッテリ  交換
バッテリ  増設
ブザー停止/テスト
電源出力
バイパス
運転
1
90%
50%
30%
-
バッテリ
 交換
バッテリ
 増設
ブザー停止/テスト
電源出力
バイパス
運転
Loosen the 2 screws
2
Hold here to disconnect
90%
50%
30%
-
バッテリ
 交換
バッテリ
 増設
ザー停止/テスト
電源出力
バイパス
運転
1
Battery connector
Plate cover
1. Checking the contents
Check whether all the package contents are included and there is no damage found on their ap­pearance. If you should notice defects or anything wrong, contact the shop of purchase.
lCompliance Information Sheet ......................1
lBattery pack xing screw (spare) ...................2
2. Replacing the battery
2-1. Procedure for replacing the battery of UPS
1. Use a screwdriver to loosen (turn counter-clockwise) the 2 screws at the top of the front panel of the unit, until they turn freely. (The screws cannot be removed from the front panel.) Pull the top of the front panel open and remove it. 1