REFERENCE
NOTE
NOTE
NOTE
- 7 - - 8 - - 9 - - 10 -
Please check whether the date, date of
birth, gender and height settings are wrong.
Refer to CHANGE/DELETE PERSONAL
DATA ( Page 8).
Even if the date, date of birth, gender and
height are correctly set, you may not take a
measurement in case that they exceed the
measurement range available or the user is
under a suitable age.
Refer to SPECIFICATIONS display
( Page 10).
The registered value or the body
composition value exceeds the
measurement range available.
Some result is displayed as
“ ”
2
“CHANGE” and “DEL” blink on the display.
Touch the (SET) button to cancel the operation.
Touch the (SET) button again.
disappear.
3
4
Stand still in the correct posture to take a
measurement.
Refer to CORRECT MEASUREMENT
METHOD (
Page 5).
Wipe the water or dirt off the buttons and
try again.
Product Name Body Composition Monitor
Model HBF-224 (HBF-224-APDB)
Display*
Body Weight:
Weight Gap:
BMI:
Body Fat percentage:
Body fat percentage classification:
Resting Metabolism:
Skeletal Muscle percentage:
Skeletal muscle percentage classification:
Visceral Fat Level:
Visceral fat level classification:
Body Age:
1 to 30 level with an increment of 1 level
0 (Normal) / + (High) / ++ (Very High) 3 levels
18 to 80 years old with an increment of 1 year
Memory: Last measurement results
Set Items
Weight Accuracy
Above 2.0 kg to 40.0 kg: ±400 g
Above 40.1 kg to 135.0 kg: ±1%
Power Supply
4 AAA manganese batteries (R03)
[You may also use 4 AAA alkaline batteries (LR03).]
Battery Life
Approximately 1 year (When AAA manganese batteries are used in accordance with the test condition)
+5°C to +35°C, 30 % to 85 % RH
-20°C to +60°C, 10 % to 95 % RH, 700 hPa - 1060 hPa
Weight Approximately 1.6 kg (including batteries)
External Dimensions
Approximately 285 (W) × 28 (H) × 280 (D) mm
Package Contents
Body Composition Monitor, trial battery (4 AAA manganese batteries) and instruction manual
Error Display Cause Correction
Cause CorrectionProblem
■ TROUBLESHOOTING TIPS
Feet are too dry.
The batteries are worn out.
Batteries are not inserted.
The buttons are wet or dirty.
12. SPECIFICATIONS
13. TECHNICAL DATA
11. TROUBLESHOOTING
Wait until “0.0 kg” is displayed before
stepping onto the unit.
Place the unit on a hard and level floor.
Warm yourself up, and then take a
measurement once you feel your circulation
is back to normal.
Slightly moisten the soles of your feet
with a damp towel and try again.
Select your personal profile number before
measurement.
Refer to Select Personal Profile Number
and Take a Measurement on HOW TO
TAKE A MEASUREMENT (
Page 7).
Replace the batteries with new ones. Refer to
BATTERY INSTALLATION ( Page 3).
Insert the batteries.
Refer to BATTERY INSTALLATION
( Page 3).
Insert the batteries in correct alignment.
Refer to BATTERY INSTALLATION
(
Page 3).
Place the unit in a warm room for a few
minutes, and then take a measurement
when you feel cold no longer by touching
the electrodes.
1
All symbols appear on the display briefly, then the display changes to “0.0kg”.
2
Select your Personal Profile Number.
Select your Personal Profile Number or GUEST
correctly before making a measurement.
Refer to Select Personal Profile Number and
Take a Measurement on HOW TO TAKE A
MEASUREMENT ( Page 7).
■ If your Personal Profile Number is incorrect…
■ If you select an incorrect Personal Profile Number…
Select your correct Personal Profile Number with the or button and touch the (SET)
button.
Then, your Personal Profile Number is confirmed and disappears.
Once you touch the (SET) button, you have to select your Personal Profile Number again.
Therefore, select a correct Personal Profile Number with the or button and touch the
(SET) button to make a confirmation.
7-2. Select Personal Profile Number and Take a
Measurement
When “ ” to “ ” blink,
Touch the buttons one by one.
You step off the unit during the
measurement.
Do not step off the unit till the measurement is completed.
(Refer to CORRECT MEASUREMENT METHOD.) Page 5
Make sure that you are standing on the unit correctly and try again.
(Refer to CORRECT MEASUREMENT METHOD.) Page 5
Remain still and do not move during measurement.
Slightly moisten the soles of your feet with a damp towel and try
again.
(Refer to CORRECT MEASUREMENT METHOD.) Page 5
Wait until 0.0 kg is displayed before stepping onto the unit.
Do not move the unit until 0.0 kg is displayed.
Do not move till measurement is completed.
Your feet are not correctly positioned
on the electrodes.
The measurement position is not
stable or your feet are not placed
correctly.
Feet are too dry.
The unit is not set up correctly.
You step onto the unit before 0.0 kg
is displayed.
Movement during measurement.
When measuring, body weight range is exceeded.
The unit moved before 0.0 kg is
displayed.
Select your Personal Profile Number or “GUEST” with
the or button and touch the (SET) button.
Nothing is displayed when the
power is turned on.
The polarities of batteries are not
aligned correctly.
“0.0 kg” is displayed or the weight
value barely increases even when
you step onto the unit.
The value of body weight is
displayed abnormally high or low.
You stepped onto the unit before
“0.0 kg” was displayed.
The measured value is
displayed abnormally high or
low.
The measured values vary
widely for each measurement.
Your posture is not correct and
measurement cannot be taken.
The measurement is taken on soft floor
surface such as carpet or uneven floor
surface.
The soles of your feet, or whole
body are cold, causing poor blood
circulation
The electrodes are extremely cold.
You are not correctly recognized
by the automatic recognition
function.
Your body weight has changed a lot
since last measurement.
Your body type and weight are
similar to another user who has been
registered.
You want to measure your body
composition, but body composition
measurement does not start after
the weight measurement has been
displayed.
You select “No.0” for your body
weight only. (A Personal Profile
Number or GUEST is not displayed)
Nothing happened when you
touch the buttons.
You touch the buttons while standing
on the main unit.
Step off the main unit before touching
them.
You touch two or more buttons at the
same time.
The power is automatically
turned off.
2 to 100 kg with an increment of 0.1 kg
100 to 135 kg with an increment of 0.2 kg
-99.9 to 99.9kg
2.5 to 90.0 with an increment of 0.1
5.0 to 50.0% with an increment of 0.1%
- (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels
385 to 3999 kcal with an increment of 1 kcal
5.0 to 60.0% with an increment of 0.1%
- (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels
Operating
Temperature/Humidity
Storage Temperature/
Humidity/Air Pressure
NOTE: Subject to technical modification without prior notice.
*Below 5 years old: Body weight, Weight Gap and BMI can be measured.
Below 17 years old: Visceral fat level and body age cannot be measured.
Above 81 years old: Body composition is for reference.
Gravity correction: Select “2” as the area code
Date: January 1, 2016 to December 31, 2040
Time: 0.00 to 23:59 24-hour notation
Personal data information: The following information can be stored for up to 4 people.
Date of birth: January 1, 1900 to December 31, 2040
Gender: Male/female
Height: 100.0 to 199.5 cm with an increment of 0.5 cm
Remark: You will need to set up these information each time you take a measurement as "GUEST".
Select the Personal Profile Number to be
changed/deleted with the or button.
NOTE
Select the Personal Profile Number you want to register with the or
button and touch the (SET) button to make a confirmation to register the
personal data.
Refer to REGISTERING PERSONAL DATA ( Page 4).
Wrong Personal Profile Number may be displayed in the following cases.
・
You have a body type or body weight similar to another user.・Your body weight changes significantly.
If inaccurate recognition continues, select your Personal Profile Number before making a measurement.
Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A
MEASUREMENT ( Page 7).
■ When “No.1” to “No.4” blink or when “GUEST” is
displayed, your Personal Profile Number cannot be
registered.
Touch the button and turn on the
power.
Your personal data are not registered in your
selected Personal Profile Number.
Register your personal data.
Refer to REGISTERING PERSONAL DATA
( Page 4).
When “ ” to “ ” blink…
Your personal data are not registered in your
selected Personal Profile Number.
Register your personal data.
Refer to REGISTERING PERSONAL DATA
( Page 4).
Touch the (SET) button to make a
confirmation.
Refer to About the Power Off Function on BATTERY INSTALLATION
( Page 3).
Above 6
years old
Above 18
years old
- 6 -
■ When Error Messages Display
Remove the batteries. Wait 1 minute. Reinstall the batteries.
Touch the button and turn on the power. Retake the
measurement.
WEIGHT
3
Check the Measurement Results.
BODY AGE
BMI
The results display rotates automatically.
Once you confirm your Personal Profile Number, you can switch it to a measured value you
want to view with the or button.
*
1
If there are no results for the last measurement or the Weight Gap exceeds the display range,
the “ ” symbol is displayed.
*2Use the as a guide to measurement. In the example shown in the screen, the body
fat percentage is determined as 0 (Normal), the visceral fat level is determined as 0 (Normal)
and the skeletal muscle percentage is determined as ++ (Very High).
Refer to UNDERSTANDING YOUR MEASUREMENT RESULTS ( Page 8) for
details of index.
RESTING
METABOLISM
Weight Gap*
1
(Difference From
Last Measurement)
BODY FAT
PERCENTAGE
Body Fat Percentage
Classification *
2
VISCERAL
FAT LEVEL
Visceral Fat Level
Classification *
2
SKELETAL
MUSCLE
PERCENTAGE
Skeletal Muscle
Percentage
Classification*
2
Hold the button for 3 seconds or longer to turn off the power.
Turn off the power
after you check the measurement results.
4
If there are no results for the last measurement, the “ ” symbol is displayed.
VIEWING THE LAST MEASUREMENT RESULTS
・If you want to display the last measurement result, touch the button after confirming your
Personal Profile Number (When is not displayed).
Touch the button again to return to the current measurement result.
If you touch the or button while the last result is displayed, the result will be switched to
another index.
・You can also view the last measurement result without measuring your body composition.
Select your Personal Profile Number and touch the button after you turn on the power and
“0.0kg” is displayed.
Touch the (SET) button.
Touch the button for 3 seconds or longer to turn off the power.
Touch the button for 3 seconds or longer to turn off the power.
Step on the main unit.
Check the body weight result.
The body weight result blinks to inform confirmation.
Step off the main unit and turn off the power.
3
4
5
Turn off the power
after you check the measurement results.
4
2
Step off the main unit.
Refer to CORRECT MEASUREMENT METHOD ( Page 5).
3
Take a measurement.
Step on the main unit.
1
Even if you measure your weight only, it is necessary for you to register your personal data.
1
8. MEASURING WEIGHT ONLY
Touch the button to turn on the power.
All symbols appear on the display briefly, then the display changes to “0.0kg”.
For Those Who Use the Guest Mode to Take a Measurement
2
Select weight “no 0”.
Do not touch or move the main unit or add objects on it before
“0.0kg” is displayed. Otherwise, it might cause incorrect measurement.
What is a Guest mode?
With this mode, you can measure your body composition without registering
your personal data in advance by entering your date of birth, gender and height
each time. When the Guest mode is used to take a measurement, the last
measurement result cannot be checked.
Select Guest “no-”.
2
1
Do not place this unit on cushioned floor
surface such as on carpet or a mat to avoid incorrect
measurement.
When the body composition is displayed,
the measurement is finished.
Select “no 0” with the or button and touch the
(SET) button to make a confirmation.
Set the date of birth, gender and
height.
“YEAR OF BIRTH” blinks.
Make a setting following Step 3 through Step 5 in REGISTERING
PERSONAL DATA ( Page 4).
■ Measurement should be taken on level and
hard surface.
9. CHANGE/DELETE PERSONAL DATA
1
All symbols appear on the display briefly, then the display changes to “0.0kg”.
If your Personal Profile Number is used by someone else, delete it and make a registration again instead
of changing it.
Touch the button to turn on the
power.
7
Touch the or button to cancel the
operation.
To Change Personal Data To Delete Personal Data
5
Touch the (SET) button.
The year of birth which has been registered blinks.
6
5
The “DEL” symbol blinks on the display.
Touch the (SET) button.
6
If a wrong setting is made during change,
confirm until the height and operate from the
very beginning once more to make a change.
10. UNDERSTANDING YOUR MEASUREMENT RESULTS
BMI =
weight (kg)÷height (m)÷height (m)
Body Fat Percentage
Classification
-(Low)
0 (Normal)
++ (Very High)
+(High)
<Body Age>
Visceral fat level
Level Classification
0 (Normal)
+(High)
++ (Very High)
1 to 9
10 to 14
15 to 30
<Visceral Fat Level>
<Skeletal Muscle Percentage>
Skeletal Muscle Percentage
Classification
-(Low)
Male Female
5.0 to 32.8%
32.9 to 35.7%
25.9 to 27.9%
28.0 to 29.0%
29.1 to 60.0%
35.8 to 37.3%
37.4 to 60.0%
0 (Normal)
+(High)
++ (Very High)
* Based on our data
Age
(Years old)
Male
Female
6 to 7
22.0 980 22.0 920
8 to 9
27.5 1,120 27.2 1,040
10 to 11
35.5 1,330 34.5 1,200
12 to 14
48.0 1,490 46.0 1,360
15 to 17
58.4 1,580 50.6 1,280
18 to 29
63.0 1,510 50.6 1,120
30 to 49
68.5 1,530 53.0 1,150
50 to 69
65.0 1,400 53.6 1,110
70 and above
59.7 1,280 49.0 1,010
Ministry of Health, Labor and Welfare: Dietary Reference Intakes of Japanese people (2010 version)
Energy necessary for life sustaining.
<BMI>
<Resting metabolism>
<Body Fat Percentage>
5.0 to 9.9%
5.0 to 19.9%
10.0
to
19.9%
20.0
to
29.9%
20.0
to
24.9%
30.0
to
34.9%
25.0% to
35.0% to
5.0 to 25.8%
Male Female
Select “CHANGE”
symbol with the or
button.
Follow Step 3 through Step 5 of
REGISTERING PERSONAL DATA
( Page 4) to make a change.
The year of birth of the selected Personal
Profile Number and blink.
You can continue to measure your body composition.
If you do not take a measurement, touch the button
for 3 seconds or longer to turn off the power.
In accordance with the international index to judge
obesity, an ideal body weight is at BMI “22”.
*The obesity classification standard advocated by Japan
Society for the Study of Obesity (Year 2000).
A level to reflect the size of fat area adhered around
viscera based on the data of our company.
*The body fat percentage is low while the visceral fat level
is high sometimes. On the contrary, the body fat
percentage is high while the visceral fat level is low.
*The visceral fat level is the standard to the last. Consult a
doctor for medical diagnosis.
Standard
Body Weight
(kg)
Resting
Metabolism
(kcal/day)
Standard
Body
Weight (kg)
Resting
Metabolism
(kcal/day)
It is the proportion of the weight of skeletal muscle
to the body weight. Skeletal muscle is the muscle
that can be trained (increased) through sports.
*The basic value is a standard. The product calculates the resting
metabolism in accordance with the body composition result.
It is the proportion of the weight of body fat to the body
weight.
<The obesity classification value advocated by Lohman (in 1986)
and Nagamine (in 1972) is used as a reference>
It is the age of the body calculated in accordance
with resting metabolism.
A comprehensive classification is made in
accordance with the comparison between body age
and actual age.
Select “DEL” symbol
with the or button.
Now, you have successfully deleted
your personal data.
Touch the button for 3 seconds or longer to turn off
the power.
The “CHANGE” symbol
blinks on the display.
Now, you have successfully changed
your personal data.
Touch the (SET)
button once more.
After “Clr” is displayed, the date of birth can
be set.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in
use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result
in incorrect operation of the may result in incorrect operation of the medical device and create a potentially unsafe
situation.
Medical devices should also not interfere with other devices. In order to regulate the requirements for EMC
(Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2:2007
standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as
well as maximum levels of electro magnetic emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2007 standard for both
immunity and emissions. Nevertheless, special precautions need to be observed:
・
Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic
fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe
situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case
the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at OMRON HEALTHCARE EUROPE
at the address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN
Asia Pacific HQ
OMRON HEALTHCARE SINGAPORE PTE LTD.
438A Alexandra Road, #05-05/08, Alexandra Technopark, Singapore 119967
www.omronhealthcare-ap.com