Omron BodyScan HBF-224 Instruction Manual

Compulsory
no 1
A 62.3Kg B 62.7Kg
21
16
30
no 1 no 3
30 days later・・・
Benzene Thinner
NOTE
Battery Low Indicator
Forbidden
- 1 - - 2 - - 4 - - 5 -
Thank you for purchasing the OMRON Body Composition Monitor.
Please read this Instruction Manual thoroughly before using the unit.
Please keep this Instruction Manual for future reference.
Body Composition Monitor
Model
INSTRUCTION MANUAL
9301973-8A
HBF-224-APDB
Feet (x4)
Foot Electrodes
Foot Electrodes
1. ABOUT THE BODY COMPOSITION MONITOR
2. KNOWING YOUR UNIT
5. SETTING THE AREA, DATE AND TIME
2
4
Notes
Display
Main Unit
Display and Buttons
Battery Low Indicator
 Symbol
If no buttons are touched for 3 minutes while setting the personal data and the power is automatically turned off.If the power goes off while you are configuring settings.
Notes on Installation
Do not place this unit in highly humid environment, where water may splash, under direct sunshine, in a place where the air conditioner blows directly, or near fire.
• Otherwise, it might cause malfunction.
Do not place this unit on cushioned floor surface such as on carpet or a mat to avoid incorrect measurement.
• Otherwise, when stepping on the main unit, it will
sunken and measurement will be affected.
Notes on use
Clean the monitor before using the unit with people who have a skin or foot disease.
• Otherwise, it will cause infection. If use the unit together, use a cloth moistened with water or neutral detergent to squeeze it well before wiping the unit,
then wipe dry with a dry cloth.
Do not use the unit for purpose other than measuring weight and body composition.
Do not step on the operation buttons.
• Otherwise, it might cause malfunction.
Notes on daily maintenance
Do not wash display unit or the main unit.
• Otherwise, it might cause malfunction.
Always keep the unit clean before use.
Wipe the main unit with a soft dry cloth.
• If necessary, use a cloth moistened with water or
neutral detergent and squeeze it well before wiping
the unit, then wipe dry with a dry cloth.
Do not wipe the unit with benzene or paint thinner.
Otherwise it might cause decolouration or malfunction.
When cleaning the unit, prevent from touching the buttons and change or delete the personal data.
Notes on storage
If storing the unit in a vertical position, always secure it so that it will not fall over.
Do not store the unit in the following conditions.
• Where water may get in.
• Extreme high temperature and humidity, direct sunshine, and dusty places.
• Where there will be sudden shock or vibration.
• In storage places of chemicals or where corrosive
gas is present.
Do not place objects on the unit or store it upside-down.
• Otherwise, it might cause malfunction.
Operation Buttons
Touch the buttons with your fingers.
Button
Displays the result of the last measurement.
Lights when the operation buttons are touched.
Touch the button to advance.
Touch continuously to
advance rapidly.
Button
Touch the button to return. Touch continuously to recede rapidly.
Button
Power ON … Touch Power OFF …
Touch and hold
Confirm Value and Set
Touch
Button
Your Personal Profile Number will be displayed after the measurement. Check your Personal Profile Number.
Be sure to register your personal data before using the automatic recognition function.
Refer to REGISTERING PERSONAL DATA ( Page 4).
7
The Body Composition Monitor is equipped with an automatic recognition function to recognize who is using the monitor in accordance with the registered personal data.
How does automatic recognition works?
Once the body composition is displayed, the measurement is finished.
Wrong Personal Profile Number may be displayed in the following
cases.
• Users of similar body type and body
weight are measured
.
Your body weight has changed since last
measurement.
The illustration shows all display items.
- 3 -
It recognizes who is using
it.
The user is
No.1!
Turn on its power and
step on it.
If inaccurate recognition continues, select your Personal Profile Number before
taking a measurement.
Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A MEASUREMENT ( Page 7).
Forbidden
Forbidden
Forbidden
Compulsory
Danger
Caution
Warning
3. SAFETY NOTES
Warning
Meanings
Meaning of danger, warning and caution
Improper use may result in possible death or serious injury.
Improper use may result in injury or property damage*.
Compulsory item (which must be observed).
Forbidden item (which is not permitted).
Improper use may cause danger resulting in death or serious injury.
Do not use without any assistance if the user has a disability.
• Otherwise, falling and injury might be caused.
Never start weight reduction or exercise therapy solely based on your own judgment. Be sure
to follow the instructions of a doctor or specialist.
• Otherwise, self-judgment might cause damage to your health.
Although tempered glass is used, please avoid imposing strong impact on the main body like
knocking it down, dropping it, dropping things on it.
• Otherwise, the impact might break the glass and cause injury. Or incorrect measurement might be caused.
Do not use the unit on tiles or other surfaces that may be slippery, such as a wet floor.
• Otherwise, slip and injury might be caused.
Do not use this unit immediately after taking a bath, or when your body, hands or feet are wet.
• Otherwise, slip and injury might be caused.
• Otherwise, water might get into this unit and cause a failure or incorrect measurement.
Do not jump or bounce on the unit.
• Otherwise, falling and injury might be caused. Or the impact might exceed its application range and
causes damage.
Do not step on the edge of the unit.
• Otherwise, falling and injury might be caused. Or incorrect measurement might be caused.
Never use this unit in combination with the following medical electronic devices.
Medical electronic implants such as pacemakers.Electronic life support systems such as an artificial heart/lung.Portable electronic medical devices such as electrocardiograph.
• This unit could cause these devices to malfunction, posing a considerable health risk to users of these devices.
Please read carefully before use.
●The following is intended to prevent personal injury or property damage of the user or other people caused by the
product.
●Symbols and definitions are as follows.
* Property damage includes damage to house, property, livestock and pet.
If you have doubt about the measured results, refer to TROUBLESHOOTING ( Page 9).
The setting range is January 1, 2016 ~ December 31, 2040. When the display reaches 2040, it will return to 2016.
Refer to Check the Measurement Results for the check method of the measurement results ( Page 6).
Now, you have completed personal data registering. Touch the button for 3 seconds or longer to turn off the power.
Your personal data have not been registered in the following cases. Please re-register the
personal data information.
1
2
Tab
1
1
2
The end with the spring is for the negative  terminal.
Close the battery cover.
3
Pull the tab of the cover upwards.
2
4. BATTERY INSTALLATION
Press the tab on the battery cover in the direction of the arrow to release the cover as illustrated.
Insert the batteries by aligning them as indicated.
NOTE
Set the date of birth.
3
Set the gender.
4
Once the gender is confirmed, (the height symbol) will blink.
6. REGISTERING PERSONAL DATA
If “0.0kg” is displayed, then that Personal Profile Number has
already been registered. Choose a different Personal Profile Number or delete
the personal data for that number. Refer to CHANGE/DELETE PERSONAL DATA ( Page 7).
2
The setting range is January 1, 1900~December 31, 2040.
Select a Personal Profile Number.
3
To use the automatic recognition function, you must register your personal data in advance.
You can register personal data of up to 4 persons.
Those whose personal data have not been registered can use a Guest mode to measure his/her body composition.
All symbols appear on the display briefly, then the display changes to “0.0kg”.
Repeat the same steps to change the month, day, hour, and minute.
Use to change and then use (SET) to confirm.
Every time the key is touched, area codes “2” and “1” will be displayed alternately. Please select area code “2”. Once area code is confirmed, the year begins to blink.
1
What is a Guest mode? Refer to For Those Who Use the Guest Mode to Take a Measurement ( Page 7).
Touch the button to turn on the power.
Touch the or button to select a Personal Profile Number, and
then touch the (SET) button.
Touch the or button to change the date, and then touch the (SET) button.
Complete setting in the sequence of “YEAR OF BIRTH”, “MONTH OF BIRTH”
and “DAY OF BIRTH”.
Once the “Birth Date” is confirmed, (the gender symbol) will blink.
Touch the or button to change the gender, and then touch
the (SET) button.
NOTE
NOTE
NOTE
Crouching
Knees bent
Your feet are not correctly positioned on the electrodes.
CORRECT MEASUREMENT METHOD
Postures to Avoid During Measurement!
Step on the Main Unit barefoot.
Step off the main unit.
Set both feet on the electrodes.
Do not place this unit on cushioned floor surface
such as on carpet or a mat to avoid incorrect measurement.
The above scenario might
be displayed during measurement. Wait for a moment.
When all symbols are lighted, the preparation for a correct measurement has been taken. If the main unit is moved or a load is applied onto it before “0.0kg” is displayed, “Err (error)” might be displayed or incorrect
measurement might be taken.
Refer to TROUBLESHOOTING ( Page 9).
Do not touch or move the main unit or add objects on it before
“0.0kg” is displayed after the power is turned on. Otherwise, it might
cause incorrect measurement.
If you wear shoes, correct
measurement cannot be taken.
Measurement should be taken on level
and hard surface.
Incorrect posture may result in inaccurate measurement of body composition.
When the body composition is displayed, the measurement is finished.
Open the Battery Cover on the back of the unit.
Battery Life and Replacement
Replace with four new batteries at the same time.
Measurement values and personal profiles stored in the memory will not be deleted during battery replacement.
Because the supplied batteries are for trial use only, they may have a shorter life.
New batteries will last for approximately one year (when manganese batteries are used with four
measurements a day at a room temperature of 23°C).
Do not use rechargeable batteries. This could cause inaccurate operation.
When the Battery Low Indicator flashes, it indicates
running out of the battery.
Dispose of the device, batteries and components according to applicable local regulations.
Replace the batteries after turning off the main unit
power.
Set the height.
5
The setting range is 100.0~199.5cm.
Step on the main unit.
6
Use the automatic recognition function to take a measurement and record the data of body composition in the unit.
Once the height is conf irmed, “0.0kg” w ill be displayed aft er the date of
birth, gender and height ar e displayed.
Refer to CORRECT MEASUREMENT METHOD ( Page 5).
Touch the or button to change the height, and then touch
the (SET) button.
If the power has turned off before you step on the main unit, select your Personal Profile Number.
Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A
MEASUREMENT ( Page 7).
2
1
When the body composition is displayed, the measurement is finished.
2
Step off the main unit.
Take a measurement.
Step on the main unit.
1
7. HOW TO TAKE A MEASUREMENT
All symbols appear on the display briefly, then the display changes to “0.0kg”.
7-1. Use the Automatic Recognition Function to Take a Measurement
When the automatic recognition function is used to take a measurement, register your personal data in
advance.
Refer to REGISTERING PERSONAL DATA ( Page 4).
Even if you do not have personal data information stored on the unit, you can use Guest mode to measure body
composition.
Touch the button to turn on the power.
Refer to CORRECT MEASUREMENT METHOD
( Page 5).
4
Set “AREA”.
Set “DATE”.
Set “TIME”.
After the settings for year, month, day, hour and minute are displayed in that sequence, the power is
automatically turned off.
4
Check your Personal Profile Number.
3
If your Personal Profile Number is correct…
Touch the (SET) button, your Personal Profile Number is confirmed and disappears.
After making a confirmation, you can switch to a desired measured value with the or
button.
Even if you turn off the power while your Personal Profile Number or blinks, it will be
recorded as the measured value of the displayed Personal Profile Number.
Caution
Disassembly
prohibited
Do not try to disassemble, repair or remodel the unit.
Otherwise, a failure or injury might be caused.
This unit is intended for home use only. It is not intended for professional use in hospitals or
other medical facilities.
• This unit does not support the standards required for professional use.
Do not use a cellular phone near the unit
• Incorrect measurement might be caused.
Do not let an infant carry it.
• Otherwise, injury might be caused.
Stand on the unit bare-footed.
• Otherwise, slip and injury might be caused or incorrect measurement might be taken.
Keep this unit out of the reach of young children.
• Otherwise, injury might be caused.
Insert the batteries with the polarities in correct direction.
• Otherwise, heat generation, liquid spill or rupture might cause damage of the unit or injury.
Use the specified battery.
Do not use new and worn batteries together or use batteries of a different kind together.
• Otherwise, heat generation, liquid spill or rupture might cause damage of the unit or injury.
Remove the batteries from this unit when you are not going to use it for a long period
(approximately three months or more) of time.
Additionally, immediately remove a battery which has run out and replace all batteries with new
ones at the same time.
• Otherwise, heat generation, liquid spill or rupture might cause damage of the unit or injury.
About the Power Off Function
Touch the button for 3 seconds or longer to turn off the power.
The “OFF” symbol appears on the display when the power is turned off.
The power is automatically turned off in the following conditions:
If the unit is not used within 1 minute of “0.0 kg” appearing on the display.If no personal data information is entered within 3 minutes.If the unit is not used for 30 seconds after weight result is displayed.If the unit is not used for 3 minutes after body composition results are displayed.10 seconds after the “Err” symbol appears on the display.
In order to measure your weight accurately, the product will correct the deviation caused by gravitational acceleration. Accurate measurement cannot be conducted if the area of the usage place, date and time are not correctly set.
Please input “2” as the area code of the usage place.
When error occurs during setting…
Turn on the power. If “year” flashed, please start from step 2 of SETTING THE AREA, DATE AND TIME.
The power is automatically turned off during setting…
Turn on the power to reset. If no operation for 3 minues during setting, the power will be automatically turned
off.
When you want to modify date and time which have already been set…
Remove the batteries and insert again after 20 seconds at least, and then turn on the unit. If “AREA” flashes,
start from step 2 of SETTING THE THE AREA, DATE AND TIME.
1
Touch the button to turn on the power.
Touch or button to change the year.
Touch the (SET) button to confirm the year and then the month flashes.
INCORRECT MEASUREMENT
A target user of the unit should be above 6 years old.
Incorrect measurement might occur to the following users:
Elderly people / People with a fever / Body builders or highly trained athletes / Patients undergoing dialysis / Patients with osteoporosis who have very low bone density / Pregnant women / People with swelling / Children
in growth stage
• Because the body composition such as body water might greatly deviate from the average value.
Caution
Danger
Year
: Forward : Back
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Month
Day
Hour
Minute
REFERENCE
NOTE
NOTE
NOTE
- 7 - - 8 - - 9 - - 10 -
Please check whether the date, date of birth, gender and height settings are wrong. Refer to CHANGE/DELETE PERSONAL DATA ( Page 8). Even if the date, date of birth, gender and height are correctly set, you may not take a measurement in case that they exceed the measurement range available or the user is
under a suitable age.
Refer to SPECIFICATIONS display ( Page 10).
The registered value or the body composition value exceeds the measurement range available.
Some result is displayed as
“ ”
2
“CHANGE” and “DEL” blink on the display.
Touch the (SET) button to cancel the operation.
Touch the (SET) button again.
  disappear.
3
4
Stand still in the correct posture to take a measurement.
Refer to CORRECT MEASUREMENT METHOD (
Page 5).
Wipe the water or dirt off the buttons and try again.
Product Name Body Composition Monitor
Model HBF-224 (HBF-224-APDB)
Display*
Body Weight:
Weight Gap:
BMI:
Body Fat percentage: Body fat percentage classification: Resting Metabolism: Skeletal Muscle percentage: Skeletal muscle percentage classification:
Visceral Fat Level: Visceral fat level classification: Body Age:
1 to 30 level with an increment of 1 level 0 (Normal) / + (High) / ++ (Very High) 3 levels 18 to 80 years old with an increment of 1 year
Memory: Last measurement results
Set Items
Weight Accuracy
Above 2.0 kg to 40.0 kg: ±400 g Above 40.1 kg to 135.0 kg: ±1%
Power Supply
4 AAA manganese batteries (R03) [You may also use 4 AAA alkaline batteries (LR03).]
Battery Life
Approximately 1 year (When AAA manganese batteries are used in accordance with the test condition)
+5°C to +35°C, 30 % to 85 % RH
-20°C to +60°C, 10 % to 95 % RH, 700 hPa - 1060 hPa
Weight Approximately 1.6 kg (including batteries)
External Dimensions
Approximately 285 (W) × 28 (H) × 280 (D) mm
Package Contents
Body Composition Monitor, trial battery (4 AAA manganese batteries) and instruction manual
Error Display Cause Correction
Cause CorrectionProblem
TROUBLESHOOTING TIPS
Feet are too dry.
The batteries are worn out.
Batteries are not inserted.
The buttons are wet or dirty.
12. SPECIFICATIONS
13. TECHNICAL DATA
11. TROUBLESHOOTING
Wait until “0.0 kg” is displayed before
stepping onto the unit.
Place the unit on a hard and level floor.
Warm yourself up, and then take a
measurement once you feel your circulation is back to normal.
Slightly moisten the soles of your feet with a damp towel and try again.
Select your personal profile number before measurement. Refer to Select Personal Profile Number and Take a Measurement on HOW TO
TAKE A MEASUREMENT (
Page 7).
Replace the batteries with new ones. Refer to
BATTERY INSTALLATION ( Page 3).
Insert the batteries.
Refer to BATTERY INSTALLATION ( Page 3).
Insert the batteries in correct alignment.
Refer to BATTERY INSTALLATION (
Page 3).
Place the unit in a warm room for a few
minutes, and then take a measurement
when you feel cold no longer by touching the electrodes.
1
All symbols appear on the display briefly, then the display changes to “0.0kg”.
2
Select your Personal Profile Number.
Select your Personal Profile Number or GUEST
correctly before making a measurement. Refer to Select Personal Profile Number and
Take a Measurement on HOW TO TAKE A MEASUREMENT ( Page 7).
If your Personal Profile Number is incorrect…
If you select an incorrect Personal Profile Number…
Select your correct Personal Profile Number with the or button and touch the (SET)
button.
Then, your Personal Profile Number is confirmed and disappears.
Once you touch the (SET) button, you have to select your Personal Profile Number again.
Therefore, select a correct Personal Profile Number with the or button and touch the
(SET) button to make a confirmation.
7-2. Select Personal Profile Number and Take a
Measurement
When “ ” to “ ” blink,
Touch the buttons one by one.
You step off the unit during the measurement.
Do not step off the unit till the measurement is completed.
(Refer to CORRECT MEASUREMENT METHOD.Page 5
Make sure that you are standing on the unit correctly and try again.
(Refer to CORRECT MEASUREMENT METHOD.Page 5
Remain still and do not move during measurement.
Slightly moisten the soles of your feet with a damp towel and try again.
(Refer to CORRECT MEASUREMENT METHOD.Page 5
Wait until 0.0 kg is displayed before stepping onto the unit.
Do not move the unit until 0.0 kg is displayed.
Do not move till measurement is completed.
Your feet are not correctly positioned on the electrodes.
The measurement position is not stable or your feet are not placed correctly. Feet are too dry.
The unit is not set up correctly.
You step onto the unit before 0.0 kg
is displayed.
Movement during measurement.
When measuring, body weight range is exceeded.
The unit moved before 0.0 kg is
displayed.
Select your Personal Profile Number or “GUEST” with
the or button and touch the (SET) button.
Nothing is displayed when the power is turned on.
The polarities of batteries are not aligned correctly.
“0.0 kg” is displayed or the weight value barely increases even when
you step onto the unit.
The value of body weight is
displayed abnormally high or low.
You stepped onto the unit before
“0.0 kg” was displayed.
The measured value is
displayed abnormally high or low.
The measured values vary
widely for each measurement.
Your posture is not correct and measurement cannot be taken.
The measurement is taken on soft floor
surface such as carpet or uneven floor
surface.
The soles of your feet, or whole body are cold, causing poor blood
circulation
The electrodes are extremely cold.
You are not correctly recognized by the automatic recognition function.
Your body weight has changed a lot since last measurement.
Your body type and weight are similar to another user who has been registered.
You want to measure your body
composition, but body composition
measurement does not start after the weight measurement has been displayed.
You select “No.0” for your body weight only. (A Personal Profile Number or GUEST is not displayed)
Nothing happened when you touch the buttons.
You touch the buttons while standing on the main unit.
Step off the main unit before touching them.
You touch two or more buttons at the same time.
The power is automatically turned off.
2 to 100 kg with an increment of 0.1 kg 100 to 135 kg with an increment of 0.2 kg
-99.9 to 99.9kg
2.5 to 90.0 with an increment of 0.1
5.0 to 50.0% with an increment of 0.1%
- (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels 385 to 3999 kcal with an increment of 1 kcal
5.0 to 60.0% with an increment of 0.1%
- (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels
Operating
Temperature/Humidity
Storage Temperature/ Humidity/Air Pressure
NOTE: Subject to technical modification without prior notice.
*Below 5 years old: Body weight, Weight Gap and BMI can be measured.
Below 17 years old: Visceral fat level and body age cannot be measured. Above 81 years old: Body composition is for reference.
Gravity correction: Select “2” as the area code
Date: January 1, 2016 to December 31, 2040 Time: 0.00 to 23:59 24-hour notation
Personal data information: The following information can be stored for up to 4 people.
Date of birth: January 1, 1900 to December 31, 2040Gender: Male/femaleHeight: 100.0 to 199.5 cm with an increment of 0.5 cmRemark: You will need to set up these information each time you take a measurement as "GUEST".
Select the Personal Profile Number to be changed/deleted with the or button.
NOTE
Select the Personal Profile Number you want to register with the or
button and touch the (SET) button to make a confirmation to register the
personal data.
Refer to REGISTERING PERSONAL DATA ( Page 4).
Wrong Personal Profile Number may be displayed in the following cases.
You have a body type or body weight similar to another user.・Your body weight changes significantly.
If inaccurate recognition continues, select your Personal Profile Number before making a measurement. Refer to Select Personal Profile Number and Take a Measurement on HOW TO TAKE A MEASUREMENT ( Page 7).
When “No.1” to “No.4” blink or when “GUEST” is
displayed, your Personal Profile Number cannot be
registered.
Touch the button and turn on the power.
Your personal data are not registered in your
selected Personal Profile Number.
Register your personal data.
Refer to REGISTERING PERSONAL DATA ( Page 4).
When “ ” to “ ” blink…
Your personal data are not registered in your
selected Personal Profile Number.
Register your personal data.
Refer to REGISTERING PERSONAL DATA ( Page 4).
Touch the (SET) button to make a confirmation.
Refer to About the Power Off Function on BATTERY INSTALLATION ( Page 3).
Above 6
years old
Above 18
years old
- 6 -
When Error Messages Display
Remove the batteries. Wait 1 minute. Reinstall the batteries.
Touch the button and turn on the power. Retake the
measurement.
WEIGHT
3
Check the Measurement Results.
BODY AGE
BMI
The results display rotates automatically.
Once you confirm your Personal Profile Number, you can switch it to a measured value you
want to view with the or button.
*
1
If there are no results for the last measurement or the Weight Gap exceeds the display range, the “ ” symbol is displayed.
*2Use the as a guide to measurement. In the example shown in the screen, the body
fat percentage is determined as 0 (Normal), the visceral fat level is determined as 0 (Normal) and the skeletal muscle percentage is determined as ++ (Very High). Refer to UNDERSTANDING YOUR MEASUREMENT RESULTS ( Page 8) for details of index.
RESTING METABOLISM
Weight Gap*
1
(Difference From Last Measurement)
BODY FAT
PERCENTAGE
Body Fat Percentage Classification *
2
VISCERAL
FAT LEVEL
Visceral Fat Level Classification *
2
SKELETAL
MUSCLE
PERCENTAGE
Skeletal Muscle Percentage Classification*
2
Hold the button for 3 seconds or longer to turn off the power.
Turn off the power
after you check the measurement results.
4
If there are no results for the last measurement, the “ ” symbol is displayed.
VIEWING THE LAST MEASUREMENT RESULTS
If you want to display the last measurement result, touch the button after confirming your
Personal Profile Number (When is not displayed).
Touch the button again to return to the current measurement result.
If you touch the or button while the last result is displayed, the result will be switched to
another index.
You can also view the last measurement result without measuring your body composition.
Select your Personal Profile Number and touch the button after you turn on the power and
“0.0kg” is displayed.
Touch the (SET) button.
Touch the button for 3 seconds or longer to turn off the power.
Touch the button for 3 seconds or longer to turn off the power.
Step on the main unit.
Check the body weight result.
The body weight result blinks to inform confirmation.
Step off the main unit and turn off the power.
3 4
5
Turn off the power
after you check the measurement results.
4
2
Step off the main unit.
Refer to CORRECT MEASUREMENT METHOD ( Page 5).
3
Take a measurement.
Step on the main unit.
1
Even if you measure your weight only, it is necessary for you to register your personal data.
1
8. MEASURING WEIGHT ONLY
Touch the button to turn on the power.
All symbols appear on the display briefly, then the display changes to “0.0kg”.
For Those Who Use the Guest Mode to Take a Measurement
2
Select weight “no 0”.
Do not touch or move the main unit or add objects on it before
“0.0kg” is displayed. Otherwise, it might cause incorrect measurement.
What is a Guest mode?
With this mode, you can measure your body composition without registering your personal data in advance by entering your date of birth, gender and height each time. When the Guest mode is used to take a measurement, the last
measurement result cannot be checked.
Select Guest “no-”.
2
1
Do not place this unit on cushioned floor
surface such as on carpet or a mat to avoid incorrect
measurement.
When the body composition is displayed, the measurement is finished.
Select “no 0” with the or button and touch the
(SET) button to make a confirmation.
Set the date of birth, gender and height.
“YEAR OF BIRTH” blinks.
Make a setting following Step 3 through Step 5 in REGISTERING PERSONAL DATA ( Page 4).
Measurement should be taken on level and
hard surface.
9. CHANGE/DELETE PERSONAL DATA
1
All symbols appear on the display briefly, then the display changes to “0.0kg”.
If your Personal Profile Number is used by someone else, delete it and make a registration again instead
of changing it.
Touch the button to turn on the power.
7
Touch the or button to cancel the operation.
To Change Personal Data To Delete Personal Data
5
Touch the (SET) button.
The year of birth which has been registered blinks.
6
5
The “DEL” symbol blinks on the display.
Touch the (SET) button.
6
If a wrong setting is made during change,
confirm until the height and operate from the
very beginning once more to make a change.
10. UNDERSTANDING YOUR MEASUREMENT RESULTS
BMI =
weight (kg)÷height (m)÷height (m)
Body Fat Percentage
Classification
-(Low)
0 (Normal)
++ (Very High)
+(High)
<Body Age>
Visceral fat level
Level Classification
0 (Normal)
+(High)
++ (Very High)
1 to 9
10 to 14
15 to 30
<Visceral Fat Level>
<Skeletal Muscle Percentage>
Skeletal Muscle Percentage
Classification
-(Low)
Male Female
5.0 to 32.8%
32.9 to 35.7%
25.9 to 27.9%
28.0 to 29.0%
29.1 to 60.0%
35.8 to 37.3%
37.4 to 60.0%
0 (Normal)
+(High)
++ (Very High)
* Based on our data
Age
(Years old)
Male
Female
6 to 7
22.0 980 22.0 920
8 to 9
27.5 1,120 27.2 1,040
10 to 11
35.5 1,330 34.5 1,200
12 to 14
48.0 1,490 46.0 1,360
15 to 17
58.4 1,580 50.6 1,280
18 to 29
63.0 1,510 50.6 1,120
30 to 49
68.5 1,530 53.0 1,150
50 to 69
65.0 1,400 53.6 1,110
70 and above
59.7 1,280 49.0 1,010
Ministry of Health, Labor and Welfare: Dietary Reference Intakes of Japanese people (2010 version)
Energy necessary for life sustaining.
<BMI>
<Resting metabolism>
<Body Fat Percentage>
5.0 to 9.9%
5.0 to 19.9%
10.0
to
19.9%
20.0
to
29.9%
20.0
to
24.9%
30.0
to
34.9%
25.0% to
35.0% to
5.0 to 25.8%
Male Female
Select “CHANGE” symbol with the or button.
Follow Step 3 through Step 5 of
REGISTERING PERSONAL DATA
( Page 4) to make a change.
The year of birth of the selected Personal Profile Number and blink.
You can continue to measure your body composition.
If you do not take a measurement, touch the button
for 3 seconds or longer to turn off the power.
In accordance with the international index to judge obesity, an ideal body weight is at BMI “22”.
*The obesity classification standard advocated by Japan
Society for the Study of Obesity (Year 2000).
A level to reflect the size of fat area adhered around viscera based on the data of our company.
*The body fat percentage is low while the visceral fat level
is high sometimes. On the contrary, the body fat percentage is high while the visceral fat level is low.
*The visceral fat level is the standard to the last. Consult a
doctor for medical diagnosis.
Standard
Body Weight
(kg)
Resting Metabolism (kcal/day)
Standard
Body
Weight (kg)
Resting Metabolism (kcal/day)
It is the proportion of the weight of skeletal muscle to the body weight. Skeletal muscle is the muscle
that can be trained (increased) through sports.
*The basic value is a standard. The product calculates the resting
metabolism in accordance with the body composition result.
It is the proportion of the weight of body fat to the body weight.
<The obesity classification value advocated by Lohman (in 1986)
and Nagamine (in 1972) is used as a reference>
It is the age of the body calculated in accordance with resting metabolism.
A comprehensive classification is made in
accordance with the comparison between body age and actual age.
Select “DEL” symbol with the or button.
Now, you have successfully deleted your personal data.
Touch the button for 3 seconds or longer to turn off
the power.
The “CHANGE” symbol
blinks on the display.
Now, you have successfully changed your personal data.
Touch the (SET) button once more.
After “Clr” is displayed, the date of birth can
be set.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in
use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result
in incorrect operation of the may result in incorrect operation of the medical device and create a potentially unsafe
situation.
Medical devices should also not interfere with other devices. In order to regulate the requirements for EMC
(Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2:2007
standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as
well as maximum levels of electro magnetic emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2007 standard for both
immunity and emissions. Nevertheless, special precautions need to be observed:
Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic
fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe
situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case
the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at OMRON HEALTHCARE EUROPE
at the address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN
Asia Pacific HQ OMRON HEALTHCARE SINGAPORE PTE LTD.
438A Alexandra Road, #05-05/08, Alexandra Technopark, Singapore 119967 www.omronhealthcare-ap.com
Loading...